Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “helicity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Multifrequency channel microwave reflectometer with frequency hopping operation for density fluctuation measurements in Large Helical Device

In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key issue of this development. For accurate phase measurement, the system utilizes a single sideband modulation technique. Currently, a dual channel heterodyne frequency hopping reflectometer system has been constructed and applied to the Alfven eigenmode measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar{sup 16+} and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and {>=}10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous projection and detection system of four different frequencies for microwave imaging reflectometry in Large Helical Device

A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of electron cyclotron emission imaging system on Large Helical Device

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of cross-field transport into the private region of detached-divertor in Large Helical Device

The fluctuation of ion saturation currents in the attached- and detached-divertor plasmas of the Large Helical Device [Fujiwara et al., Nucl. Fusion 41, 1355 (2001)] has been measured using a Langmuir probe array embedded in a divertor plate. Analytical results indicate that these fluctuation properties differ considerably from each other; for instance, the mean value distribution expands to and positive spikes propagate toward a private region from the divertor leg in the detached-divertor. We investigated the magnetic field lines traced from probe electrodes by using the KMAG code [Nakamura et al., J. Plasma Fusion Res. 69, 41 (1993)], and it is then confirmed that the propagation direction of positive spikes corresponds to that predicted by the theory of blobby plasma transport. This phenomenon is expected to lead to the broadening of plasma particle and heat fluxes to the divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: A helical velocity selector for continuous molecular beams

We report on a modern realization of the classic helical velocity selector for gas phase particle beams. The device operates stably under high vacuum conditions at rotational frequencies limited only by commercial dc motor capabilities. Tuning the rotational frequency allows selective scanning over a broad velocity band. The width of the selected velocity distributions at full-width-half-maximum is as narrow as a few percent of the selected mean velocity and independent of the rotational speed of the selector. The selector generates low vibrational noise amplitudes comparable to mechanically damped state-of-the-art turbo-molecular pumps and is therefore compatible with vibration sensitive experiments like molecule interferometry.

43 PARTICLE ACCELERATORS↗

High-Gradient High-Energy-Gain Inverse Free Electron Laser Experiment Using a Helical Undulator

In this paper we present the design of the high-gradient, high-energy-gain IFEL accelerator proposed for construction at the ATF beamline in BNL. We plan to accelerate the ATF electron beam from 50 MeV to 120 MeV using a 60 cm long tapered permanent magnet helical undulator designed at UCLA and the existing ATF 0.5 TW CO2 laser system. The experiment will obtain a record 120 MV/m gradient and >70 MeV energy gain and will be an important step in the development of compact IFEL accelerators for the mid-high energy range (up to 1-2 GeV).

43 PARTICLE ACCELERATORS↗

Design and performance of a punch mechanism based pellet injector for alternative injection in the large helical device

A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii R{sub c}= 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.

42 ENGINEERING↗

Electron density dependence of intensity ratio for FeXXII extreme ultraviolet emission lines arising from different ground levels in electron beam ion trap and large helical device

Extreme ultraviolet (EUV) spectra of highly charged iron ions in a wavelength range of 100-300 A have been observed from two different plasma sources of the Tokyo Electron Beam Ion Trap (Tokyo-EBIT) with a monoenergetic electron beam and a Large Helical Device (LHD) with Maxwellian electron energy. The excitation process of the spectral lines is compared between the two plasmas, and it is found that the excitation process for Fe XIX - Fe XXII ions is clearly different. Namely, the EUV emission lines from the EBIT plasma are only dominated by electron impact excitation connected to the ground state, but the excitation mechanism is not so simple in the LHD plasma. The difference in the excitation process is studied by measuring the intensity ratio of EUV emission lines (114.412 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 3/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 3/2}]/117.144 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 1/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 1/2}]) arising from different ground levels in the Fe XXII ions. The line intensity ratio has an extremely small value of 0.2 in the EBIT plasma with a low beam current of 30 mA and a beam energy of 2 keV, while the ratio varies with the electron density n{sub e} in the LHD plasmas, i.e., 0.35 for n{sub e} = 1 x 10{sup 13} cm{sup -3} and 0.65 for n{sub e} = 4 x 10{sup 13} cm{sup -3}. Here, the electron density of the EBIT plasma is estimated to be smaller than 10{sup 12} cm{sup -3} and the electron temperature of the LHD plasmas is 2 keV. The dependence of the line intensity ratio on the observed electron density is analyzed for both the EBIT and the LHD plasmas using several collisional-radiative (CR) models. The present experimental data can easily be reproduced by the analysis when the thermal proton impact excitation is taken into account. The importance of the proton impact excitation is also experimentally verified by injecting an iron pellet into the LHD plasmas and changing the ratio of the proton density to the electron density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic linear model of the interaction of helical magnetic perturbations with cylindrical plasmas

The linear kinetic model of the interaction of helical rotating magnetic perturbations (resonant and nonresonant) with a tokamak plasma developed in [M. F. Heyn et al., Nucl. Fusion 46, S159 (2006)] is extended by a Galilean invariant collision operator and a different finite Larmor radius expansion scheme of particle current density. The model is applied to study the plasma screening effect on resonant magnetic perturbations and the resulting torques acting on the plasma at various orders of Larmor radius expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional axisymmetric and three-dimensional helical equilibrium in the line-tied screw pinch

The line-tying condition at a conducting anode is shown to provide a localized modification to the well-understood 1-D screw pinch equilibrium in the presence of bulk plasma diamagnetism. Diamagnetic currents cannot flow near the conducting anode and are measured to disappear in a localized boundary layer, causing a weak mirror configuration that breaks 1-D equilibrium and causes large parallel pressure gradients suggestive of significant radial outflows. For sufficiently large plasma currents, the paramagnetic nature of parallel current drives the equilibrium to paramagnetism and destroys the mirror effect. At a critical plasma current, the axisymmetric equilibrium is found to transition to a long-lived, rotating, helical 3-D equilibrium state. Internal measurements of this state via multi-point correlation analysis techniques illustrate that it preserves the flux surfaces and pressure profile of the axisymmetric equilibrium. Measurements indicate that despite the fact that the flux surfaces wander at the anode, the line-tied boundary conditions are not necessarily violated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of sheet plumes, current coils, and helical magnetic fields in a spherical magnetohydrodynamic dynamo

Aiming at understanding of magnetic field generation process in rapidly rotating stars and planets represented by the Earth, computer simulations of magnetohydrodynamic (MHD) dynamo were performed in a rotating spherical shell geometry. Thermal convection and dynamo process with Ekman number of the order of 10{sup -7} were studied. New structures of convection motion, dynamo-generated electrical current, and magnetic field are found. The flow is organized as a set of thin, sheet-like plumes. The current is made of small-scale coil structure with magnetic flux tubes within each of the coil. These flux tubes are connected each other to form a large scale helical magnetic field structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute intensity calibration of flat-field space-resolved extreme ultraviolet spectrometer using radial profiles of visible and extreme ultraviolet bremsstrahlung continuum emitted from high-density plasmas in Large Helical Device

A precise absolute intensity calibration of a flat-field space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 60-400 A is carried out using a new calibration technique based on radial profile measurement of the bremsstrahlung continuum in Large Helical Device. A peaked vertical profile of the EUV bremsstrahlung continuum has been successfully observed in high-density plasmas (n{sub e}{>=} 10{sup 14} cm{sup -3}) with hydrogen ice pellet injection. The absolute calibration can be done by comparing the EUV bremsstrahlung profile with the visible bremsstrahlung profile of which the absolute value has been already calibrated using a standard lamp. The line-integrated profile of measured visible bremsstrahlung continuum is firstly converted into the local emissivity profile by considering a magnetic surface distortion due to the plasma pressure, and the local emissivity profile of EUV bremsstrahlung is secondly calculated by taking into account the electron temperature profile and free-free gaunt factor. The line-integrated profile of the EUV bremsstrahlung continuum is finally calculated from the local emissivity profile in order to compare with measured EUV bremsstrahlung profile. The absolute intensity calibration can be done by comparing measured and calculated EUV bremsstrahlung profiles. The calibration factor is thus obtained as a function of wavelength with excellent accuracy. It is also found in the profile analysis that the grating reflectivity of EUV emissions is constant along the direction perpendicular to the wavelength dispersion. Uncertainties on the calibration factor determined with the present method are discussed including charge-coupled device operation modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional measurement of edge impurity emissions using space-resolved extreme ultraviolet spectrometer in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 50-500 A has been developed to measure two-dimensional distribution of impurity spectral lines emitted from edge plasma of Large Helical Device (LHD), in which the magnetic field is formed by stochastic magnetic field with three-dimensional structure called ergodic layer. The two-dimensional measurement of edge impurity line emissions is carried out by scanning horizontally the observation chord of the space-resolved EUV spectrometer during single LHD discharge. Images of CIV (312.4 A) and HeII (303.78 A) are presented as the first result. The results are compared with ones calculated from the edge chord length in the ergodic layer of LHD plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core density gradient fluctuation measurement by differential interferometry in the helically symmetric experiment stellarator

The interferometer system on the Helically Symmetric eXperiment (HSX) stellarator uses an expanded beam and linear detector array to realize a multichord measurement. Unlike conventional interferometry which determines the plasma phase shift with respect to a reference, directly evaluating the phase between two adjacent chords can be employed to measure the change in plasma phase with impact parameter. This approach provides a measure of the equilibrium density gradient or the density gradient fluctuations and is referred to as differential interferometry. For central chords, measurements are spatially localized due to a geometrical weighting factor and can provide information on core density gradient fluctuations. The measurement requires finite coherence between fluctuations in the two spatially offset chords. This technique is applied on the HSX stellarator to measure both broadband turbulence and coherent modes. Spatial localization is exploited to isolate core turbulence changes associated with change in magnetic configuration or heating location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of high-energy neutral particles on extreme ultraviolet spectroscopy in large helical device

Spectra measured by an extreme ultraviolet (EUV) spectrometer frequently suffer large spike noise when Large Helical Device is operated in low-density range ({<=}3 Multiplication-Sign 10{sup 13} cm{sup -3}) with neutral beam injection (NBI). The spike noise completely disappears in electron cyclotron heating discharges. In order to examine the effect of NBI, a carbon filter with thickness of 150 nm was installed in the EUV spectrometer. As a result, the spike noise was reduced by an order of magnitude. It is experimentally verified that the spike noise is caused by escaping high-energy neutral particles resulting from the circulating high-energy hydrogen ions borne from NBI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal disruptions and sawtooth like activity in Large Helical Device

Large Helical Device (LHD) inward-shifted configurations are unstable to resistive magnetohydrodynamic (MHD) pressure-gradient-driven modes. These modes drive sawtooth like events during LHD operation. In this work, we simulate sawtooth like activity and internal disruptions in order to improve the understanding of these relaxation events and their effect over the device efficiency to confine the plasma, with the aim to improve the LHD present and future operation scenarios minimizing or avoiding the disadvantageous MHD soft and hard limits. By solving a set of reduced non-linear resistive MHD equations, we have studied the evolution of perturbations to equilibria obtained before and after a sawtooth like event in LHD. The equilibrium {beta} value is gradually increased during the simulation until it reaches the experimental value. Sawtooth like events and internal disruption events take place in the simulation for {beta}{sub 0} values between 1% and 1.48%. The main driver of the sawtooth like events is the resonant and non-resonant effect of the (n = 1, m = 3) mode. The instability is stronger for resonant events, and they only appear when {beta}{sub 0} = 1.48%. Internal disruptions are mainly driven by the (n = 1, m = 2) mode, and they extend throughout the whole plasma core. Internal disruption events do not show up when resonant sawtooth like events are triggered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗