Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Clean Cities 2016 Vehicle Buyer's Guide

Drivers and fleets are increasingly turning to the hundreds of light-duty, alternative fuel, and advanced technology vehicle models that reduce petroleum use, save on fuel costs, and cut emissions. This guide provides a comprehensive list of the 2016 light-duty models that use alternative fuels or advanced fuel-saving technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Terahertz Chiral Metamaterials Enabling Broadband Polarization Conversion Using Polarization Guiding Effect

Polarization control plays a vital role in terahertz (THz) photonics, enabling a wide range of applications from imaging and spectroscopy to sensing and wireless communication. However, conventional polarization control methods at THz frequencies are limited by narrow operational bandwidths and excessive absorption losses. In this work, we present a broadband THz polarization control based on the polarization guiding effect. We design and fabricate a THz polarization rotator capable of rotating incident linear polarization by 90°. The device consists of 24 twistingly stacked silicon–air metagrating layers that introduce a large degree of form birefringence, with each metagrating layer being 280 µm thick and sequentially twisted by 3.75°. Numerical simulations using the Berreman 4 × 4 method predict broadband operation of the device. Experimental validation using THz time-domain spectroscopy confirms efficient and broadband 90° polarization rotation from 0.2 to 1.25 THz. Based on this concept, we further propose THz Q-plates for the generation of broadband structured vector beams with radial and azimuthal polarization states. This work offers a scalable, material-agnostic platform for advanced THz polarization manipulation and vector beam engineering, opening new pathways for next-generation THz photonic devices.

36 MATERIALS SCIENCE↗

Hazard analysis for identifying common cause failures of digital safety systems using a redundancy-guided systems-theoretic approach

Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection, digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. Here, this paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the causal factors of potential single points of failure in the design of digital safety systems in advanced plant designs.

42 ENGINEERING↗

Acute Toxicity in Definitive Versus Postprostatectomy Image-Guided Radiotherapy for Prostate Cancer

Purpose: To assess the incidence of acute gastrointestinal (GI) and genitourinary (GU) injury and the dose-volume response in patients with clinically localized prostate cancer treated with image-guided radiotherapy using helical tomotherapy. Methods and Materials: Between November 2004 and March 2007, 146 consecutive patients with localized prostate cancer were treated with helical tomotherapy at the City of Hope Medical Center. Of the 146 patients, 70 had undergone prostatectomy. Acute GI and GU toxicities were evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Cancer of Medical scoring system. Events were scored for patients developing Grade 2 or greater morbidity within 90 days after the end of radiotherapy (RT). The dosimetric parameters included the minimal dose received by the highest 10%, 20%, 50%, 80%, and 90% of the target volume, the mean rectal dose, minimal rectal dose, maximal rectal dose, and the volume receiving {>=}45, {>=}65, and {>=}70 Gy. These variables, plus the status of radical prostatectomy, hormonal therapy, RT techniques, and medical conditions, were included in a multivariate logistic regression analysis. A goodness-of-fit evaluation was done using the Hosmer-Lemeshow statistic. Results: A dose-response function for acute GI toxicity was elicited. The acute GI Grade 2 or greater toxicity was lower in the definitive RT group than in the postoperative RT group (25% vs. 41%, p <0.05). Acute GU Grade 2 or greater toxicity was comparable between the two groups. No grade 3 or greater complications were observed. No dosimetric variable was significant for GU toxicity. For acute GI toxicity, the significant dosimetric parameters were the minimal dose received by 10%, 20%, and 50% of the target volume and the mean rectal dose; the most predictive parameter was the minimal dose received by 10% of the target volume. The dose-modifying factor was 1.2 for radical prostatectomy. Conclusion: The results of our study have shown that acute rectal symptoms are dose-volume related. Postprostatectomy RT resulted in a greater incidence of acute GI toxicity than did definitive RT. For postoperative RT, it would be prudent to use different dose-volume limits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Alignment Results of In-Room Computed Tomography-Guided Stereotactic Body Radiation Therapy for Lung Cancer

Purpose: To determine the extent of interfractional setup errors and day-to-day organ motion errors by assessing daily bone alignment results and changes in soft tissue tumor position during hypofractionated, in-room computed tomography (CT)-guided stereotactic body radiation therapy (SBRT) of lung cancer. Methods and Materials: Daily alignment results during SBRT were analyzed for 117 tumors in 112 patients. Patients received 40-50 Gy of SBRT in four to five fractions using an integrated CT-LINAC system. The free-breathing CT scans acquired during treatment setup were retrospectively realigned to match with each of the bony references and the gross tumor volume (GTV) defined on the reference CT by rigid-body registration, and the daily deviations were calculated. Results: The mean magnitude ({+-} SD) three-dimensional shift from the initial skin marks to the final bone-aligned positions was 9.4 {+-} 5.7 mm. The mean daily GTV deviation from the bone position was 0.1 {+-} 3.8 mm in the anterior-posterior direction, -0.01 {+-} 4.2 mm in the superior-inferior direction, and 0.2 {+-} 2.5 mm in the lateral direction. A clinically noteworthy trend (net change >5 mm in any direction) in GTV position relative to the bone was observed in 23 cases (20%). Conclusions: Soft tissue target position can change significantly beyond the motion envelope defined in the original internal target volume in four-dimensional CT-based treatment planning for SBRT of lung cancer. Additional margin should be considered for adequate coverage of interfractional changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Encouraging Early Clinical Outcomes With Helical Tomotherapy-Based Image-Guided Intensity-Modulated Radiation Therapy for Residual, Recurrent, and/or Progressive Benign/Low-Grade Intracranial Tumors: A Comprehensive Evaluation

Purpose: To report early clinical outcomes of helical tomotherapy (HT)-based image-guided intensity-modulated radiation therapy (IMRT) in brain tumors of varying shape, size, and location. Materials and Methods: Patients with residual, recurrent, and/or progressive low-grade intracranial and skull-base tumors were treated on a prospective protocol of HT-based IMRT and followed clinicoradiologically. Standardized metrics were used for plan evaluation and outcome analysis. Results: Twenty-seven patients with 30 lesions were treated to a median radiotherapy dose of 54 Gy in 30 fractions. All HT plans resulted in excellent target volume coverage with steep dose-gradients. The mean (standard deviation) dose homogeneity index and conformity index was 0.07 (0.05) and 0.71 (0.08) respectively. At first response assessment, 20 of 30 lesions were stable, whereas 9 showed partial regression. One patient with a recurrent clival chordoma though neurologically stable showed imaging-defined progression, whereas another patient with stable disease on serial imaging had sustained neurologic worsening. With a median follow-up of 19 months (interquartile range, 11-26 months), the 2-year clinicoradiological progression-free survival and overall survival was 93.3% and 100% respectively. Conclusions: Careful selection of radiotherapy technique is warranted for benign/low-grade brain tumors to achieve durable local control with minimum long-term morbidity. Large or complex-shaped tumors benefit most from IMRT. Our early clinical experience of HT-based IMRT for brain tumors has been encouraging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Variations in Radiotherapy of Anal Cancer: Advantages of Target Volume Reduction Using Image-Guided Radiation Treatment

Purpose: To define setup variations in the radiation treatment (RT) of anal cancer and to report the advantages of image-guided RT (IGRT) in terms of reduction of target volume and treatment-related side effects. Methods and Materials: Twelve consecutive patients with anal cancer treated by combined chemoradiation by use of helical tomotherapy from March 2007 to November 2008 were selected. With patients immobilized and positioned in place, megavoltage computed tomography (MVCT) scans were performed before each treatment and were automatically registered to planning CT scans. Patients were shifted per the registration data and treated. A total of 365 MVCT scans were analyzed. The primary site received a median dose of 55 Gy. To evaluate the potential dosimetric advantage(s) of IGRT, cases were replanned according to Radiation Therapy Oncology Group 0529, with and without adding recommended setup variations from the current study. Results: Significant setup variations were observed throughout the course of RT. The standard deviations for systematic setup correction in the anterior-posterior (AP), lateral, and superior-inferior (SI) directions and roll rotation were 1.1, 3.6, and 3.2 mm, and 0.3 Degree-Sign , respectively. The average random setup variations were 3.8, 5.5, and 2.9 mm, and 0.5 Degree-Sign , respectively. Without daily IGRT, margins of 4.9, 11.1, and 8.5 mm in the AP, lateral, and SI directions would have been needed to ensure that the planning target volume (PTV) received {>=}95% of the prescribed dose. Conversely, daily IGRT required no extra margins on PTV and resulted in a significant reduction of V15 and V45 of intestine and V10 of pelvic bone marrow. Favorable toxicities were observed, except for acute hematologic toxicity. Conclusions: Daily MVCT scans before each treatment can effectively detect setup variations and thereby reduce PTV margins in the treatment of anal cancer. The use of concurrent chemotherapy and IGRT provided favorable toxicities, except for acute hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating a ponderomotive guiding center algorithm into a quasi-static particle-in-cell code based on azimuthal mode decomposition

High fidelity modeling of plasma based acceleration (PBA) requires the use of three dimensional, fully nonlinear, and kinetic descriptions based on the particle-in-cell (PIC) method. In PBA an intense particle beam or laser (driver) propagates through a tenuous plasma whereby it excites a plasma wave wake. Three-dimensional PIC algorithms based on the quasi-static approximation (QSA) have been successfully applied to efficiently model the interaction between relativistic charged particle beams and plasma. In a QSA PIC algorithm, the plasma response to a charged particle beam or laser driver is calculated based on forces from the driver and self-consistent forces from the QSA form of Maxwell's equations. These fields are then used to advance the charged particle beam or laser forward by a large time step. Since the time step is not limited by the regular Courant-Friedrichs-Lewy (CFL) condition that constrains a standard 3D fully electromagnetic PIC code, a 3D QSA PIC code can achieve orders of magnitude speedup in performance. Recently, a new hybrid QSA PIC algorithm that combines another speedup technique known as an azimuthal Fourier decomposition has been proposed and implemented. This hybrid algorithm decomposes the electromagnetic fields, charge and current density into azimuthal harmonics and only the Fourier coefficients need to be updated, which can reduce the algorithmic complexity of a 3D code to that of a 2D code. Modeling the laser-plasma interaction in a full 3D electromagnetic PIC algorithm is very computationally expensive due the enormous disparity of physical scales to be resolved. In the QSA the laser is modeled using the ponderomotive guiding center (PGC) approach. We describe how to implement a PGC algorithm compatible for the QSA PIC algorithms based on the azimuthal mode expansion. Here this algorithm permits time steps orders of magnitude larger than the cell size and it can be asynchronously parallelized. Details on how this is implemented into the QSA PIC code that utilizes an azimuthal mode expansion, QPAD, are also described. Benchmarks and comparisons between a fully 3D explicit PIC code (OSIRIS), as well as a few examples related to laser wakefield acceleration, are presented.

97 MATHEMATICS AND COMPUTING↗

Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Stereotactic Body Radiotherapy for Lung Tumors Using BodyLoc With Tomotherapy: Clinical Implementation and Set-Up Accuracy

We investigated the use of a BodyLoc immobilization and stereotactic localization device combined with TomoTherapy megavoltage CT (MVCT) in lung stereotactic body radiotherapy (SBRT) to reduce set-up uncertainty and treatment time. Eight patients treated with 3-5 fractions of SBRT were retrospectively analyzed. A BodyLoc localizer was used in both CT simulation for localization and the initial patient treatment set-up. Patients were immobilized with a vacuum cushion on the back and a thermoplastic body cast on the anterior body. Pretreatment MVCT from the TomoTherapy unit was fused with the planning kilovoltage CT (KVCT) before each fraction of treatment to determine interfractional set-up error. The comparison of two MVCTs during a fraction of treatment resulted in the intrafractional uncertainty of the treatment. A total of 224 target isocenter shifts were analyzed to assess these inter- and intrafractional tumor motions. We found that for interfractional shifts, the mean set-up errors and standard deviations were -1.1 {+-} 2.8 mm, -2.5 {+-} 8.7 mm, and 4.1 {+-} 2.6 mm, for lateral, longitudinal, and vertical variation, respectively; the mean setup rotational variation was -0.3 {+-} 0.7 deg.; and the maximum motion was 13.5 mm in the longitudinal direction. For intrafractional shifts, the mean set-up errors and standard deviations were -0.1 {+-} 0.7 mm, -0.3 {+-} 2.0 mm, and 0.5 {+-} 1.1 mm for the lateral, longitudinal, and vertical shifts, respectively; the mean rotational variation was 0.1 {+-} 0.2 deg.; and the maximum motion was 3.8 mm in the longitudinal direction. There was no correlation among patient characteristics, set-up uncertainties, and isocenter shifts, and the interfractional set-up uncertainties were larger than the intrafractional isocenter shift. The results of this study suggested that image-guided stereotactic body radiotherapy using the BodyLoc immobilization system with TomoTherapy can improve treatment accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conditional guide RNA deactivation by mRNA and small molecule triggers in Saccharomyces cerevisiae

CRISPR interference (CRISPRi) technologies have revolutionized bioengineering by providing precise tools for gene expression modulation, enabling targeted gene perturbation and metabolic pathway optimization. Despite these advances, achieving dynamic control over gene expression by CRISPR-based regulation remains a challenge due to its inherently static nature. Utilizing toehold-mediated strand displacement and ligand-responsive ribozymes (aptazymes), this study introduces switchable guide RNAs (gRNAs) that facilitate tunable gene expression mediated by mRNA or small molecule signals. We demonstrate complete silencing of gRNA via strategically designed 5’ or 3’ extensions that impede the gRNA spacer or the dCas9 handle, with subsequent restoration of function through sequestration or cleavage of the obstructive sequence. The resulting toehold-embedded or aptazyme-embedded gRNAs can be deactivated by specific signals, including two full-length translatable mRNAs and two small molecule triggers, thereby lifting CRISPRi repression on targeted genes. This modular approach allows for gRNA-based biocomputing through multi-layer or multi-input genetic logic gates in Saccharomyces cerevisiae . Offering a versatile strategy for post-CRISPR regulation in response to environmental signals or cellular states, this methodology expands the toolkit in eukaryotic systems for reversible control of gene expression.

Aptazyme↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Updating the MCNP neutron guide extension for supermirror absorption, gamma production, and neutron polarization

As supermirror technology has developed, there is a trend towards higher m-values for supermirrors which propagate more neutrons with higher divergence to experimental areas. These supermirrors have thousands of alternating layers of typically nickel and titanium with varying thicknesses deposited on the surface. Neutrons of grazing incidence are reflected from these layers with a probability dependent on the angle of incidence and the wavelength of the neutron. Those neutrons that are not reflected may be captured in the supermirror layers and produce high energy gamma rays that require shielding. The supermirror extension for MCNP has been updated to estimate the capture of neutrons in the supermirror layers of a neutron guide through the banking of photons in a virtual supermirror layer and the reduction of the weight of the neutrons transmitted into the substrate. A new functionality has been added to simulate neutron polarization specifically in the context of a supermirror polarizer for neutron beamlines. In conclusion, the underlying theory, code implementation in MCNP, and examples of gamma production and a V-cavity polarizer will be discussed.

Gamma production↗

Airborne hyperspectral imaging of cover crops through radiative transfer process-guided machine learning

Cover cropping between cash crop growing seasons is a multifunctional conservation practice. Timely and accurate monitoring of cover crop traits, notably aboveground biomass and nutrient content, is beneficial to agricultural stakeholders to improve management and understand outcomes. Currently, there is a scarcity of spatially and temporally resolved information for assessing cover crop growth. Remote sensing has a high potential to fill this need, but conventional empirical regression operated with coarse-resolution multispectral data has large uncertainties. Therefore, this study utilized airborne hyperspectral imaging techniques and developed new process-guided machine learning approaches (PGML) for cover crop monitoring. Specifically, we deployed an airborne hyperspectral system covering visible to shortwave-infrared wavelengths (400–2400 nm) to acquire high spatial (0.5 m) and spectral (3–5 nm) resolution reflectance over 23 cover crop fields across Central Illinois in March and April of 2021. Airborne hyperspectral surface reflectance with high spectral and spatial resolution can be well matched with field data to quantify cover crop traits. Furthermore, the PGML models were pre-trained by synthetic data from soil-vegetation radiative transfer modeling (one million records), and then fine-tuned with field data of cover crop biomass and nutrient content. Results show that airborne hyperspectral data with PGML can achieve high accuracy to predict cover crop aboveground biomass (R 2 = 0.72, relative RMSE = 15.16%) and nitrogen content (R 2 = 0.69, relative RMSE = 16.59%) through leave-one-field-out cross-validation. Unlike the pure data-driven approach (e.g., partial least-squares regression), PGML incorporated radiative transfer knowledge and obtained higher predictive performance with fewer field data. Meanwhile, with field data for model fine-tuning, PGML predicted biomass more accurately than the inversion of radiative transfer models. Here we also found that the red edge has a high contribution in quantifying aboveground biomass and nitrogen content, followed by green and shortwave spectra. This study demonstrated the first attempt of utilizing hyperspectral remote sensing to accurately quantify cover crop traits. We highlight the strength of PGML in exploiting sensing data to quantify ecosystem variables to advance agroecosystem monitoring for sustainable agricultural management.

60 APPLIED LIFE SCIENCES↗

Theoretical solution for light transmission of a bended hollow light guide

Hollow light guides with very high reflective inner surfaces are novel daylight systems that collect sunlight and skylight available on the roof of buildings transporting it into deep or windowless interiors in building cores. Thus the better utilization of daylight can result in energy savings and wellbeing in these enclosed indoor spaces. An analytical complex solution of a straight tube system was solved in the HOLIGILM method with a user-friendly tool available on the http://www.holigilm.info. An even more difficult light flow transport is to be determined in bended tubes usually placed on sloped roofs where a bend is necessary to adjust the vertical pass through the ceilings. This paper presents the theoretical derivation of the model with its graphical representation and coordinate system respecting backward ray-tracing bend distortions. To imagine the resulting illuminance on the horizontal plane element in the interior, the virtual ray (i.e. luminance in an elementary solid angle) has to pass the ceiling diffuser interface, the inner mirror like tube with a bend, through a roof cupola attachment to the element of the sky and sun light source. Due to this complexity and the lengthy derivation and explanations more practical applications will be published later in a separate contribution. (author)

14 SOLAR ENERGY↗

Physics-guided machine learning for improved accuracy of the National Solar Radiation Database

The National Solar Radiation Database (NSRDB) provides high-resolution spatiotemporal solar irradiance data for the entire globe. The NSRDB uses a two-step Physical Solar Model (PSM) to compute the effects of clouds and other atmospheric variables on the solar radiation reaching the surface of the Earth. Physical and optical cloud properties are fundamental inputs to the PSM and are derived from the National Oceanic and Atmospheric Administration's Geostationary Operational Environmental Satellites. This paper describes recent improvements to the NSRDB driven by physics-guided machine learning methods for cloud property retrieval. The impacts of these new methods on the NSRDB irradiance data are validated using an extensive set of ground measurement sites, showing significant improvement for all sites. We report on average, the mean absolute percentage error for global horizontal irradiance and direct normal irradiance show reductions of 2.16 and 3.95 percentage points respectively for all daylight conditions, 5.92 and 17.39 percentage points respectively for cloudy conditions, and 9.00 and 22.59 percentage points respectively for gap-filled cloudy conditions. These new methods will help improve the quality and accuracy of the irradiance and cloud data in the NSRDB.

14 SOLAR ENERGY↗