Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The shape of spectral lines: The importance of the far wings

Spectroscopy, the study of the interaction of radiation and matter, provides most of the information we have gleaned about the composition, structure, and evolution of the universe. As is well known, by measuring the frequencies of spectral lines in absorption or emission, one can uniquely infer the presence of atoms or molecules as well as their physical state and environment (e.g., solid or gaseous, neutral or ionized, moving or stationary, etc.). Furthermore, by studying the intensities of these lines, one can determine the abundance (i.e., number of a particular species per unit volume). Although less well known, the shape of the spectral lines, in particular, the structure of the far wings, plays a very important role in many important atmospheric phenomena such as the greenhouse effect or the absorption of harmful ultraviolet radiation. Although first measured more than 50 years ago, the anomalous absorption of radiation by water vapor in the earth's atmosphere was postulated to be due to far wings of allowed lines. However, only within the past few years has a quantitative verification of this hypothesis been possible through the development of an accurate theoretical description of the shape of self-broadened water lines. During the summer, work has been done on improving this theory and in comparing the results to other theories valid near the center of the lines. The relevance of this work to measurements of greenhouse gases, of earth-based measurements of the 3 K cosmic background radiation, of satellite-based measurements of the atmospheres of the earth and other planets, and other similar problems will be discussed briefly.

Tipping, Richard↗

Measurement and modeling of the radio frequency sheath impedance in a large magnetized plasma

The DC and RF properties of radio frequency (RF) driven sheaths were studied in the Large Plasma Device (LAPD) at the University of California, Los Angeles. The experiments diagnosed RF sheaths on field lines connected to a grounded plate at one end and an ion cyclotron range of frequencies (ICRF) antenna at the other end. The experimental setup permitted measurement of the RF sheath impedance at the plate as a function of DC sheath voltage, with the latter controlled by varying the RF current applied to the antenna. Here, the DC current-voltage characteristics of these sheaths and the RF sheath impedance measurements were compared with modeling. Hot electrons, present in the LAPD plasma, were inferred to contribute significantly to both the DC and RF currents and hence the RF impedance. It was postulated that at very low power hot electrons could not access the region of the plasma subject to RF waves, resulting in an increased RF impedance. Within some experimental limitations and significant assumptions, an RF sheath impedance model was verified by the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from milli-second pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar lightcurve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

PULSAR↗

Application of X-Ray Pulsar Navigation: A Characterization of the Earth Orbit Trade Space

The potential for pulsars as a navigation source has been studied since their discovery in 1967. X-ray pulsar navigation (XNAV) is a celestial navigation system that uses the consistent timing nature of x-ray photons from millisecond pulsars (MSP) to perform space navigation. By comparing the detected arrival of x-ray photons to a reference database of expected pulsar light-curve timing models, one can infer a range and range rate measurement based on light time delay. Much of the challenge of XNAV comes from the faint signal, availability, and distant nature of pulsars. This is a study of potential pulsar XNAV measurements to measure extended Kalman filter (EKF) tracking performance with a wide trade space of bounded Earth orbits, using a simulation of existing x-ray detector space hardware. An example of an x-ray detector for XNAV is the NASA Station Explorer for X-ray Timing and Navigation (SEXTANT) mission, a technology demonstration of XNAV set to perform on the International Space Station (ISS) in late 2016early 2017. XNAV hardware implementation is driven by trajectory and environmental influences which add noise to the x-ray pulse signal. In a closed Earth orbit, the radiation environment can exponentially increase the signal noise from x-ray pulsar sources, decreasing the quality and frequency of measurements. The SEXTANT mission in particular improves on the signal to noise ratio by focusing an array of 56 x-ray silicon drift detectors at one pulsar target at a time. This reduces timing glitches and other timing noise contributions from ambient x-ray sources to within a 100 nanosecond resolution. This study also considers the SEXTANT scheduling challenges inherent in a single target observation. Finally, as the navigation sources are now relatively inertial targets, XNAV measurements are also subject to periods of occultation from various celestial bodies. This study focuses on the characterization of these drivers in closed Earth orbits and is not a tuning analysis of the EKF. The study shows that the closed Earth orbit for XNAV performance is reliant on the orbit semi-major axis and eccentricity as well as orbit inclination. These parameters are the primary drivers of pulsar measurement availability and significantly influence the natural spacecraft orbit dynamics. Sensitivity to initial orbit determination error growth due to the scarcity of XNAV measurements within an orbital period require appropriate timing of initial XNAV measurements. The orbit angles of argument of perigee and right ascension of the ascending node, alongside the other orbit parameters, complete the initial cadence of XNAV measurements. The performance of initial XNAV measurements then propagates throughout the experimental period. The study provides a basis to missions who wish to consider XNAV as a potential navigation source in a closed Earth orbit design. It provides a family of orbit trajectories as well as other modeling considerations needed to effectively evaluate if XNAV is an effective navigation source for a potential mission. As an EKF is sensitive to a linearized estimated state, this study has a direct benefit of providing effective XNAV measurements to maintain spacecraft tracking, independent of other navigation sources. In the particular use case of the SEXTANT mission, it also provides a novel scheduling algorithm which addresses the need to prioritize and manage pulsar observations for effective navigation.

x-ray↗

Preliminary measurements of plasma fluctuations in an 8-cm mercury ion thruster

The rms magnitude, spectra, and cross correlations for the fluctuations in the beam current, the neutralizer keeper current, and the discharge current and voltage were measured for an 8-cm diameter, dished grid ion thruster for a beam current of 72 milliamps. The ratio of the rms magnitude of the fluctuations to the time-mean neutralizer keeper current was found to depend significantly on the neutralizer time-mean keeper current, the flow rate, and keeper hold diameter. The maxima of the spectra of the beam current fluctuations did not depend on the discharge fluctuations. It was found that: (1) the discharge current fluctuations do not directly contribute to the beam current fluctuations; and (2) the neutralizer contributions to the beam fluctuations are small (for good neutralizer-to-beam coupling) but not negligible and appear mostly in the higher frequency range measured.

Serafini, J. S.↗

Residue Specific Characterization of Electrostatics, Conformational Heterogeneity, and Dynamics of Electron Transfer Proteins with Linear and Nonlinear Infrared Spectroscopy. Final Report

The goal of this research project was to further our understanding of biological electron transfer through the development and application of new methods for studying proteins and their complexes with high spatial and temporal detail. The approach was based on incorporation of reporter bonds with distinct vibrational frequencies at specific locations in proteins and their characterization through the interaction of the bonds with pulses of infrared light. The project focused on the proteins plastocyanin (Pc) and cytochrome (cyt) f, two electron transfer partners in photosynthesis. The first thrust of the project was the incorporation of carbon deuterium bonds as non-perturbative probes at a ligand to the copper ion of Pc and their use to detect changes in the bonding due to the number of electrons at the metal and how the bonding changes upon association with cyt f. Toward developing more advanced approaches to characterize proteins, we incorporated a stronger reporter, the cyano group of cyanophenylalanine, at several locations in Pc and measured the frequency dynamics in the absence and presence of cyt f. The acquired data improved the current model for the protein complex. Notably, the data indicated that the majority of the population is involved in a loosely bound complex, providing insight into the nature of the ensembles formed by electron transfer protein complexes that is not available via other approaches. In addition to learning about the protein complex, we made strides toward developing and improving the new experimental approach to study highly dynamic behaviors of proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Bioelectrical impedance analysis. What does it measure?

Bioelectrical impedance analysis (BIA) has been proposed for measuring fat-free mass, total body water, percent fat, body cell mass, intracellular water, and extracellular water: a veritable laboratory in a box. Although it is unlikely that BIA is quite this versatile, correlations have been demonstrated between BIA and all of these body compartments. At the same time, it is known that all of the compartments are correlated among themselves. Because of this, it is difficult to determine whether BIA is specific for any or all of these compartments. To investigate this question, we induced acute changes in total body water and its compartments over a 3-h period. Using this approach, we demonstrated that multifrequency BIA, using the Cole-Cole model to calculate the zero frequency and infinite frequency resistance, measures extracellular and intracellular water.

NASA Discipline Regulatory Physiology↗

Atomic-scale imaging of frequency-dependent phonon anisotropy

Directly visualizing vibrational anisotropy in individual phonon modes is essential for understanding a wide range of intriguing optical, thermal and elastic phenomena in materials. Although conventional optical and diffraction techniques have been used to estimate vibrational anisotropies, they fall short in achieving the spatial and energy resolution necessary to provide detailed information. Here, we introduce a new form of momentum-selective electron energy-loss spectroscopy, which enables the element-resolved imaging of frequency- and symmetry-dependent vibrational anisotropies with atomic resolution. Vibrational anisotropies manifest in different norms of orthogonal atomic displacements, known as thermal ellipsoids. Using the centrosymmetric strontium titanate as a model system, we observed two distinct types of oxygen vibrations with contrasting anisotropies: oblate thermal ellipsoids below 60 meV and prolate ones above 60 meV. In non-centrosymmetric barium titanate, our approach can detect subtle distortions of the oxygen octahedra by observing the unexpected modulation of q-selective signals between apical and equatorial oxygen sites near 55 meV, which originates from reduced crystal symmetry and may also be linked to ferroelectric polarization. These observations are quantitatively supported by theoretical modelling, which demonstrates the reliability of our approach. The measured frequency-dependent vibrational anisotropies shed new light on the dielectric and thermal behaviours governed by acoustic and optical phonons. Furthermore, the ability to visualize phonon eigenvectors at specific crystallographic sites with unprecedented spatial and energy resolution opens new avenues for exploring dielectric, optical, thermal and superconducting properties.

Ferroelectrics and multiferroics↗

Experiment Do14: Ultrahigh and very high frequency polarization

The measurement of inhomogeneities in the electron content along the orbital paths of Gemini 8 and Gemini 9 missions was not accomplished because the tracking information was not available. The use of ultrahigh frequency radio transmission was the primary factor in the successful removal of a very high frequency Faraday rotation ambiguity; but, as was expected, this was not very useful for fine-scale polarization studies. Ionosonde data were useful in the computation of the slab thickness at the closest point of approach of the spacecraft.

Ellis, R. E.↗

Phased Array Characterization of Slat Noise Radiation from a High-Lift Common Research Model

A test campaign was conducted in the open-jet test section of the NASA Langley 14- by 22-Foot Subsonic Tunnel on a 10%-scale, semispan version of a High-Lift Common Research Model (CRM-HL) incorporating a leading-edge slat, trailing-edge flap and removable high-fidelity main landing gear. Far field acoustic measurements were obtained on baseline and acoustically treated model configurations using a traversing 97-microphone phased array that viewed the pressure side of the airframe. A modified version of the DAMAS deconvolution method incorporating corrections for shear layer acoustic wave decorrelation was employed to determine the locations and strengths of relevant noise sources along the span of the slat and in the vicinity of the flap edges and landing gear. The main goal of the test campaign was to use the array data to evaluate the effectiveness of various slat noise reduction concepts. It was found that slat-gap fillers produced significant broadband noise reduction for all Mach numbers and airfoil angles of attack that were investigated. Mach number scaling revealed an approximate velocity to the sixth power relationship for the slat noise at higher frequencies. Directivity measurements obtained from integration of DAMAS pressure-squared values over defined geometric zones around the model showed that baseline slat noise radiation approximated a dipole as a function of polar emission angle, becoming approximately omnidirectional with the introduction of the slat-gap filler. The test campaign clearly demonstrated the noise reduction benefits that can be obtained by applying appropriate treatments to leading edge slats on commercial transport-class aircraft.

William M Humphreys, Jr.↗

Improved accuracy and robustness of electron density profiles from JET’s X-mode frequency-modulated continuous-wave reflectometers

JET’s frequency-modulated continuous wave (FMCW) reflectometers have been operating well with the current design since 2005, and density profiles have been automatically calculated intershot since then. However, the calculated profiles had long suffered from several shortcomings: poor agreement with other diagnostics, sometimes inappropriately moving radially by several centimeters, elevated levels of radial jitter, and persistent wriggles (strong unphysical oscillations). Here, in this research, several techniques are applied to the reflectometry data analysis, and the shortcomings are significantly improved. Starting with improving the equilibrium reconstruction that estimates the background magnetic field, adding a ripple correction in the reconstructed magnetic field profile, and adding new inner-wall reflection positions estimated through ray-tracing, these changes not only improve the agreement of reconstructed profiles to other diagnostics but also solve density profile wriggles that were present during band transitions. Other smaller but also persistent wriggles were also suppressed by applying a localized correction to the measured beat frequency where persistent oscillations are present. Finally, the burst analysis method, as introduced by Varela et al., has been implemented to extract the beat frequency from stacked spectrograms. Due to the strong suppression of spurious reflections, the radial jitter that sometimes would span several centimeters has been strongly reduced. The stacking of spectrograms has also been shown to be very useful for stacking recurring events, like small gas puff modulations, and extracting transport coefficients that would otherwise be below the noise level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier Dynamics of Polar, Semipolar, and Nonpolar InGaN/GaN LEDs Measured by Small-Signal Electroluminescence

The carrier dynamics in InGaN/GaN light-emitting diodes (LEDs) are directly tied to their efficiency and maximum modulation speed, which are important metrics for solid-state lighting, displays, and optical communication. In this work, we measure the carrier dynamics of a variety of InGaN/GaN LEDs using small-signal electroluminescence methods [1]. A rate equation approach and associated small-signal circuit are used to model carrier injection, recombination in the active region, recombination in the cladding regions, and carrier escape. The model is fit to the measured optical frequency response (S21) and input impedance (S11) of the LEDs to extract the various carrier lifetimes, the carrier density, and the radiative and non-radiative recombination rates. We specifically study planar nonpolar and semipolar LEDs, which show record-high modulation speeds for III-nitride LEDs and present the modulation characteristics of core-shell nanowire-based LEDs. The planar nonpolar m-plane ($101\bar{0}$) micro-LEDs achieve a record-high -3dB modulation bandwidth for a III-nitride LED of 1.5 GHz [2]. The -3dB response of an electrically injected nanowire-based micro-LED with nonpolar facets is also reported, showing a -3dB bandwidth of 1.2 GHz [3]. The high speed is attributed to the shorter carrier lifetime associated with the nonpolar orientation. We also study the carrier dynamics in semipolar ($20\bar{2}\bar{1}$) LEDs for various temperatures [4]. Finally, we present carrier dynamics measurements on commercial-grade c-plane epitaxy for various active region designs, including a wavelength series and a growth quality series. The wavelength series offers insight into the contributions of the quantum confined Stark effect (QCSE) and InGaN material quality on the green gap [5]. The growth quality series investigates the role of non-radiative centers on the LED performance. Extraction of the carrier dynamics using small-signal electroluminescence offers insight into the factors limiting the efficiency and high-speed performance of III-nitride emitters and can be leveraged to ultimately improve the devices.

LEDs, InGaN, electroluminescence, bandwidth, modul↗

Measurement System and Method

System and methods are disclosed for fluid measurements which may be utilized to determine mass flow rates such as instantaneous mass flow of a fluid stream. In a preferred embodiment, the present invention may be utilized to compare an input mass flow to an output mass flow of a drilling fluid circulation stream. In one embodiment, a fluid flow rate is determined by utilizing a microwave detector in combination with an acoustic sensor. The acoustic signal is utilized to eliminate 2pi phase ambiguities in a reflected microwave signal. In another embodiment, a fluid flow rate may be determined by detecting a phase shift of an acoustic signal across two different predetermined transmission paths. A fluid density may be determined by detecting a calibrated phase shift of an acoustic signal through the fluid. In another embodiment, a second acoustic signal may be transmitted through the fluid to define a particular 2pi phase range which defines the phase shift. The present invention may comprise multiple transmitters/receivers operating at different frequencies to measure instantaneous fuel levels of cryogenic fuels within containers positioned in zero or near zero gravity environments. In one embodiment, a moveable flexible collar of transmitter/receivers may be utilized to determine inhomogenuities within solid rocket fuel tubes.

G Dickey Arndt↗

Automating the interpretation of PM 2.5 time–resolved measurements using a data–driven approach

The rapid development of automated measurement equipment enables researchers to collect greater quantities of time-resolved data from indoor and outdoor environments. While significant, the interpretation of the resulting data can be a time-consuming effort. This paper introduces an automated process of interpreting PM 2.5 time-resolved data and differentiating PM 2.5 emissions resulting from indoor and outdoor sources. Here, we use Random Forest (RF), a machine learning approach, to study a dataset of 836 indoor emission events that occurred over a 2-week period in 18 apartments in California. In this paper, we show model development and evaluate its performance as the sample size and source vary. We discuss the characteristics of the dataset that tended to help the source identification and why. For example, we show that data from many events and from different apartments are essential for the model to be suitable for analyzing a new separate dataset. We also show that longitudinal data appear to be more helpful than the time frequency of measurements within a given apartment. We use the resulting RF model to analyze PM 2.5 data of an entirely separate dataset collected from 65 new homes in California. The RF model identifies 442 indoor emission events, with only a few misidentifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The development of a stepped frequency microwave radiometer and its application to remote sensing of the Earth

The design, development, application, and capabilities of a variable frequency microwave radiometer are described. This radiometer demonstrated the versatility, accuracy, and stability required to provide contributions to the geophysical understanding of ocean and ice processes. A closed-loop feedback method was used, whereby noise pulses were added to the received electromagnetic radiation to achieve a null balance in a Dicke switched radiometer. Stability was achieved through the use of a constant temperature enclosure around the low loss microwave front end. The Dicke reference temperature was maintained to an absolute accuracy of 0.1 K using a closed-loop proportional temperature controller. A microprocessor based digital controller operates the radiometer and records the data on computer compatible tapes. This radiometer exhibits an absolute accuracy of better than 0.5 K when the sensitivity is 0.1 K. The sensitivity varies between 0.0125 K and 1.25 K depending upon the bandwidth and integration time selected by the digital controller. Remote sensing experiments were conducted from an aircraft platform and the first radiometeric mapping of an ocean polar front; exploratory experiments to measure the thickness of lake ice; first discrimination between first year and multiyear ice below 10 GHz; and the first known measurements of frequency sensitive characteristics of sea ice.

Harrington, R. F.↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

cadmium compounds↗

Measurement of the muon anomalous precession frequency $\omega_a$ in the Fermilab $g-2$ experiment

The Fermilab Muon $g-2$ Experiment was designed to measure the muon's anomalous magnetic moment $a_{\mu} = (g-2)/2$ to 140 parts per billion. The value of $a_{\mu}$ is proportional to the difference frequency $\omega_a=\omega_s-\omega_c$ between the muon's cyclotron frequency and spin precession frequency in the uniform magnetic field of the $g-2$ storage ring. The frequency $\omega_a$ is extracted from the time distribution of the mu-decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. We will discuss the various approaches to the frequency determination including the reconstruction, fitting of time distributions, and procedures for handling the effects of gain changes, positron pileup and beam dynamics. We also discuss the data consistency checks and the strategy for the averaging of $\omega_a$ across the different analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On-wafer vector network analyzer measurements in the 220-325 Ghz frequency band

We report on a full two-port on-wafer vector network analyzer test set for the 220-325 GHz (WR3) frequency band. The test set utilizes Oleson Microwave Labs frequency extenders with the Agilent 8510C network analyzer. Two port on-wafer measurements are made with GGB Industries coplanar waveguide (CPW) probes. With this test set we have measured the WR3 band S-parameters of amplifiers on-wafer, and the characteristics of the CPW wafer probes. Results for a three stage InP HEMT amplifier show 10 dB gain at 235 GHz [1], and that of a single stage amplifier, 2.9 dB gain at 231 GHz. The approximate upper limit of loss per CPW probe range from 3.0 to 4.8 dB across the WR3 frequency band.

coplanar waveguides↗