Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Post-Calibration Uncertainty Analysis for Travel Times at a Naval Weapons Industrial Reserve Plant

The Naval Weapons Industrial Reserve Plant (NWIRP) in McGregor, Texas began manufacturing explosives in 1980 and several hazardous chemicals were discovered in lakes and streams surrounding the site in 1998. Contaminants traveled to local lakes and streams much faster than initially predicted. This research estimated contaminant travel times and identified locations where monitoring wells should be installed to yield the greatest reductions in uncertainties in travel-time predictions. To this end, groundwater and particle-tracking models for NWIRP site were built to predict hydraulic heads and contaminant travel times. Next, parameter (hydraulic conductivities) uncertainties, parameter identifiabilities, observation (hydraulic heads) worth, and predictive (contaminant travel times) uncertainties were quantified. Parameter uncertainties were reduced by up to 92%; a total of 19 of 158 parameters were at least moderately identifiable; travel-time uncertainties were reduced up to 92%. Additionally, travel-time predictions and post-calibration parameter distributions were generated using the null-space Monte Carlo (NSMC) technique. NSMC predicted that conservative tracers exited the flow system within a year, which matches with field data. Finally, an observations-worth analysis found that additional 11 more measurements would reduce travel-time uncertainties by factors from 1.04 to 4.3 over existing data if monitoring wells were installed at the suggested locations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geochemical and microbial characteristics of seepage water and mineral precipitates in a radwaste disposal facility impacted by seawater intrusion and high alkalinity

The construction of an underground facility can dramatically change the quality, flow direction, and level of groundwater. It may also impact subsurface microbial composition and activity. Groundwater quality was monitored over eight years in two observational wells near an underground disposal facility on the east coast of South Korea. The results showed dramatic increases in dissolved ions such as O 2 , Na, Ca, Mg, and SO 4 during facility construction. Seepage water samples downgradient from the silos and tunnels, and precipitates deposited along the seepage water flow path were collected to determine the impact inside the disposal facility. X-ray analysis (powder X-ray diffraction (pXRD) and X-ray absorption fine structure (XAFS)) were used to characterize the mineral precipitates. Microbial community composition was determined by 16S rRNA gene sequencing. The seepage water composition was of two types: Ca-Cl and Ca-Na-HCO 3 . The ratio of Cl and δ 18 O showed that the Ca-Cl type seepage water was influenced by groundwater mixed with seawater ranging from 2.7% to 15.1%. Various sulfate-reducing bacteria were identified in the Ca-Cl type seepage water, exhibiting relatively high sulfate content from seawater intrusion. Samples from the Ca-Na-HCO 3 type seepage water had an extremely high pH (>10) and abundance of Hydrogenophaga. The precipitates observed along the flow path of the seepage water included calcite, ferrihydrite, green rust, and siderite, depending on seepage water chemistry and microbial activity. This study suggests that the construction of underground structures creates distinct, localized geochemical conditions (e.g., high alkalinity, high salinity, and oxic conditions), which may impact microbial communities. These biogeochemical changes may have undesirable large-scale impacts such as water pump clogging. Overall, an understanding of the process and long-term monitoring are essential to assess the safety of underground facilities.

54 ENVIRONMENTAL SCIENCES↗

Oil in Alaska North Slope Gas Hydrate Reservoir: Micro-CT and Flow Simulation Insights into Permeability

Gas hydrate-bearing sands on the Alaska North Slope (ANS) host minor volumes of crude oil whose impact on formation permeability has never been quantified relative to a gas hydrate reservoir system. Here, we combine in situ pressure-core microcomputed-tomography (μ-CT), thermogravimetric analysis (TGA), gas-chromatography–mass-spectrometry (GC–MS), scanning-electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), and Stokes-flow simulation to (i) quantify oil saturation, (ii) infer its source, and (iii) evaluate its influence on permeability after gas-hydrate dissociation. μ-CT and SEM-EDS imaging identify the host sediment as silty, with some grain-coating clay present. Eight representative 3003-voxel subvolumes extracted from a preserved pressure core (Core 15P-3c, from the B1 sand (unit B), HYDRATE 02 Geo Data Well (GDW), 886.96–887.29 m measured depth, MD) exhibit porosities of 0.34–0.37 and an average oil saturation of 0.09 ± 0.03, in comparison to an independent TGA-based estimate of 0.16. GC-MS fingerprints obtained from an adjacent depressurized core (Core 17P-1, 891.37–891.44 m MD), together with oil pore habit revealed by μ-CT, suggest that the oil is partly native but also includes contributions from mineral oil-based drilling fluid contamination. Further analysis of oil–porewater interactions and flushing tests confirms that native oil saturation in the analyzed samples ranges from 0.04 to 0.08 with an average of approximately 0.06, and the oil is highly immobile. Flow simulations demonstrate that the native oil saturation of ≈0.06 reduces permeability by approximately 50% due to both pore blockage and increased flow-path tortuosity. These findings reveal the potential presence of native oil within the ANS gas hydrate reservoir and suggest that future simulation models may need to account for its impact on permeability to improve long-term performance predictions of gas and water production.

02 PETROLEUM↗

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Counter-Current Flow Limitation Studies in Complex Geometries Utilizing Interface Capturing Simulations Coupled with PID Flow Rate Controller

In nuclear thermal-hydraulic studies, counter-current flow limitation (CCFL) typically refers to steam rising at a fast rate such that it prevents coolant from draining down within a confined channel. CCFL is a crucial issue in nuclear reactor safety analysis. This study investigates CCFL in debris bed channels using high-resolution interface-capturing simulations. A novel proportional-integral-derivative flow rate controller is developed to efficiently achieve the CCFL conditions. Verification studies confirm that CCFL occurs under the same conditions with or without the controller, demonstrating that PID control ensures accurate prediction. Three debris bed channel geometries were examined: a cylindrical channel, a channel with small obstacles, and a channel with large obstacles. Results show that obstacles significantly impact flow behavior, interfacial shear, wall shear, and pressure gradients required for CCFL. Furthermore, the comparison with experimental data confirmed that simulations incorporating geometric complexities align more closely with experimental CCFL conditions. A pressure gradient correlation was also developed for CCFL prediction.

Counter-current flow limitation↗

Preliminary Pilot-scale Study and Techno-economic Analysis of Chemical Heat Pump with Conventional Nuclear Reactors

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear source is clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. A pilot-scale study was conducted for Chemical Heat Pump (ChHP) system at three different scales (25-, 100-, and 1000-kW thermal outputs) using steady state thermal model. To establish the viability of selling heat rather than electricity alone, techno-economic analysis was undertaken for advanced Small Modular Reactor (SMR), and SMR paired with varied thermal output ChHP systems was referred to as the nuclear hybrid energy system (NHES) in this study. Using the U.S. Energy Information Administration statistics, pricing for electricity and natural gas were anticipated for U.S. regions (California, Northwest, Midwest, Southwest, New England, and PJM). Based on thermal output from ChHP, advanced SMR with 100 MWth and four alternative NHES scenarios were explored, namely 50-, 10-, 5-, and 1-MWth. Net present value, payback period, discounted cash flow return, and levelized cost of energy were evaluated for all scenarios. Based on the economic analysis, selling heat to high-temperature industrial processes is more profitable compared to selling electricity only. Higher carbon taxes showed significant improvement in economic parameters for NHESs. Providing heat to high-temperature industries could be beneficial, helping to reduce the greenhouse gas emissions by slashing the fossil fuel consumption.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Formulation and Performance Evaluation of Epoxy Sealant Systems for Double-Shell Tank Bottom Refurbishment

The performance of epoxy sealants used in the refurbishment of double-shell tank (DST) systems requires balancing processability, thermomechanical stability, and adhesion to cementitious substrates. This study incorporates Heloxy 8 as a reactive diluent into Westlake 862 epoxy to tailor workability and cured-state properties. Rheological time-sweep analysis demonstrates that increasing the diluent content significantly reduces complex viscosity and extends workability, thereby improving pumpability and flow for large-area applications. However, the targeted 2-hour processing window is not fully achieved. Differential scanning calorimetry (DSC) confirms that all formulations cure at room temperature to glass transition temperatures ( T g ) at least 20 °C above the maximum DST operating temperature (27 °C), thereby ensuring service in the glassy regime. Dynamic mechanical analysis (DMA) reveals formulation-dependent reductions in tan delta and increases in storage modulus, indicating increasingly elastic and mechanically stable networks with diluent incorporation. Pull-off adhesion testing shows that modified formulations (70–90% Westlake epoxy) exhibit significantly higher adhesion strengths than the unmodified system. Grout cohesive failure indicates that interfacial bonding exceeds substrate strength. Collectively, these results demonstrate that controlled reactive diluent incorporation enables optimization of processing behavior, interfacial adhesion, and thermomechanical performance, supporting the suitability of the modified epoxy systems as durable sealant layers for cementitious barrier applications in hazardous waste containment infrastructure.

Differential scanning calorimetry↗

Computing water flow through complex landscapes – Part 2: Finding hierarchies in depressions and morphological segmentations

Depressions – inwardly draining regions of digital elevation models – present difficulties for terrain analysis and hydrological modeling. Analogous “depressions” also arise in image processing and morphological segmentation, where they may represent noise, features of interest, or both. Here we provide a new data structure – the depression hierarchy – that captures the full topologic and topographic complexity of depressions in a region. We treat depressions as networks in a way that is analogous to surface-water flow paths, in which individual sub-depressions merge together to form meta-depressions in a process that continues until they begin to drain externally. This hierarchy can be used to selectively fill or breach depressions or to accelerate dynamic models of hydrological flow. Complete, well-commented, open-source code and correctness tests are available on GitHub and Zenodo.

54 ENVIRONMENTAL SCIENCES↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Computational and Experimental Study of Film-Cooling Effectiveness With and Without Downstream Vortex Generators

Downstream vortex generators that involve a pair of rectangular plates arranged in an open V-shape placed just downstream of each film-cooling hole were shown to create flow and vortical structures that entrain lifted film-cooling flow back to the surface and increase its lateral spreading on the surface (GT2020–14317). In this study, computations and measurements were performed to examine the flow mechanisms this vortex generator induces to improve film-cooling effectiveness of a flat plate with the cooling flow emanating from one row of inclined holes. Parameters studied include blowing ratio (BR = 0.75 and 1.0) and temperature ratio (TR = 1.07 and 1.9). Here, the computational study is based on steady Reynolds-averaged Navier–Stokes (RANS) closed by the shear-stress transport (SST) turbulence model with and without conjugate analysis. The experimental study was conducted by using a conjugate heat transfer test rig with a plenum, where cooling flow is introduced. Measurements made include velocity and temperature profiles upstream and downstream of the film-cooling holes as well as the temperature at several locations on the hot and cold sides of the film-cooled flat plate. The computational study was validated by comparing computed results with those from measurements at BR = 0.75 and 1.0 and TR = 1.9. Computational and experimental results are presented to show the effects of BR and TR on the flow structures and how those structures improve the effectiveness of film cooling with and without the downstream vortex generators and with and without conjugate heat transfer.

42 ENGINEERING↗

EWTN: Quantifying Mass Transport to Enable Water Electrolyzer Architectures with Low Flow-Rate Sensitivity

To develop cost-effective and high-performing polymer electrolyte water electrolyzers (PEWEs) for gigawatt-scale applications, researchers have focused on reducing precious metal catalyst loadings and optimizing porous transport layers. However, the performance of PEWEs is also affected by system architecture. Mass transport losses are dependent on localized architecture and material interactions. In-situ measurements, such as current density distribution maps have demonstrated advantages in understanding the intricate characteristics and influence of two-phase flow within PEWEs. This study proposes the parameter of effective water transport number (EWTN) as a quantitative tool to investigate such current density distribution (CDD) measurements for PEWEs. Results show that higher flow-rates have EWTN values of 0.95 and above, indicating no mass transport limitations; while lower flow-rates with large gradients CDD have EWTN values between 0.6-0.8, indicating mass transport limited conditions. The new analysis also identified a correlation between mass transport losses due to bubble accumulation, membrane hydration, and ohmic overpotentials. To address these limitations, an unitized pin-type LGDL/flow-field design was developed, which effectively prevents local gas phase accumulation, resulting in improved mass transport characteristics. The results of this work show reduced flow-rate sensitivity with the pin-type architecture and ∼13% increased performance at 0.24 ml / min / cm 2 .

Electrochemistry↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Thermodynamic Analysis of Nano-Electrospray Induced Gas Jets

Nano-electrospray (nES) produces a plume of charged liquid droplets which have drag interactions with the surrounding gas after they are emitted from a source capillary. The resulting induced gas flow has often been considered unimportant, but we have demonstrated that a gas microjet of significant velocity up to 10s of m/s can be produced. In this work we present a thermodynamic framework that enables analysis of gas jet generation from electrosprays and introduce the important metrics for such analysis, effectiveness (a measure of momentum transfer from the electrosprayed aerosol to gas) and efficiency (a measure of energy conversion from electrical energy generating the electrospray to gas kinetic energy). This analytical framework is applicable to any two-phase flows consisting of discrete conservative-force-driven particles which exchange momentum with an inert, otherwise quiescent fluid medium to yield a co-flowing two-phase jet. Here, we apply this framework to sprays of water from nano-electrospray emitters to demonstrate that increasing the applied electrical potential difference, increasing liquid mass flowrate, and decreasing droplet size all can increase electrospray induced gas jet strength, but only the latter two do so while also increasing the momentum transfer effectiveness and energy conversion efficiency.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assessment of small mechanical wastewater treatment plants: Relative life cycle environmental impacts of construction and operations

Many slow growing and shrinking rural communities struggle with aging or inadequate wastewater treatment plants (WWTPs), and face challenges in constructing and operating such facilities. Although existing literature has provided insight into the environmental sustainability of large facilities, including both the construction and operational phases, these studies have not examined small, rural facilities treating less than 7,000 m 3 /d (1.8 MGD) of wastewater in adequate depth and breadth. In this study, a detailed inventory of the construction and operational data for 16 case studies of small WWTPs was developed to elucidate their environmental life cycle impacts. Conventional LCA framework was followed. The results show that the environmental impacts of both the construction and operational phases are considerable. Operational impacts are highly related to energy usage. Improving energy efficiency of a plant may reduce the environmental impacts related to operations. Construction impacts can vary considerably between facilities. Process-related factors (e.g., concrete and reinforcing steel used in basins) are typically sized using the design flow; thus much of the variability in construction impacts among plants stems from the non-process related infrastructure. Multiple regression analysis was used as an exploratory tool to identify which non-process related plant aspects contribute to the variable environmental impact of small WWTPs. These factors include aluminum, cast iron, and the capacity utilization ratio (defined as the ratio of average flow to design flow). Furthermore, industry practitioners should consider these factors when aiming to reduce the environmental impacts of a small WWTP related to construction. Scenario sensitivity analyses found that the environmental impact of construction became smaller with longer design life, and the end-of-life consideration does not heavily influence the environmental sustainability of a WWTP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of iPSCs derived pancreatic β-like cells using pancreatic bio-scaffold

This study aimed toengineer a pancreatic tissue. Intact rat pancreases were successfully decellularized, and were reseeded with human-induced pluripotent stem cells using different 2D and 3D culture growth factors. The differentiation process was assessed for the presence of a pancreas-like tissue. The histology and SEM analysis revealed cell attachment in all samples, except for the Exp4, and the Flow-cytometry provided 87% viability for the differentiated cells. In Exp1, PDX1 with the positive expression of 2.87±0.06 was dramatically higher than Exp2 with a 2.44±0.06 reaction. NGN3-reactions were 8±0.1 and 6.6±0.2 in Exp1 and Exp2 at P < 0.05, respectively. C-peptide with the expression of 7.5±0.7 in Exp3 was almost equal to that in Exp1 and Exp2. Glucagon (5.1±1) and PDX1 (3.2±0.82) in Exp3 indicated no significant difference. The significant upregulations of pancreatic endocrine markers (PDX1 and NGN3), and the cell-specific glucose transporter (GLUT2) were observed in the differentiated IPCs in the 3D culture of Exp2 after 21 days. The highest insulin and C-peptide concentrations were observed in Exp2. In Exp3, insulin secretion in response to high glucose and 10 mM arginine was 42.43 ±6.34 μU/ml. A decellularized pancreas in the presence of hiPSCs and growth factors could be efficiently used as a natural scaffold.

60 APPLIED LIFE SCIENCES↗

Impact of the electron density and temperature gradient on drift-wave turbulence in the Large Plasma Device

In this paper we present an experimental study of edge turbulence in the Large Plasma Device at UCLA. We utilize a scan of discharge power and prefill pressure (neutral density) to show experimentally that turbulent density fluctuations decrease with decreasing density gradient, as predicted for resistive drift-wave turbulence (RDWT). As expected for RDWT, we observe that the cross-phase between the density and potential fluctuations is close to 0. Moreover, the addition of an electron temperature gradient leads to a reduction in the amplitude of the density fluctuations, as expected for RDWT. However, counter to theoretical expectations, we find that the potential fluctuations do not follow the same trends as the density fluctuations for changes either in density gradients or the addition of a temperature gradient. The disconnect between the density and potential fluctuations is connected to changes in the parallel flows as a result of differences in the prefill pressure, i.e. neutral density. Further analysis of the density and potential fluctuation spectra show that the electron temperature gradient reduces the low frequency fluctuations up to $10 \,{\rm kHz}$ and the introduction of a temperature gradient leads to an unexpected ${\sim }{\rm \pi}$ shift of the density–potential cross-phase at ${\sim }10\,{\rm kHz}$ , while maintaining the typical resistive drift-wave cross-phase at lower frequencies. These experiments partly confirm existing knowledge on resistive drift-wave turbulence, but also introduce new observations that indicate a need for dedicated nonlinear three-dimensional turbulence simulations that include neutrals.

Physics↗