Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “finite element method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Validating corrosion models: Influence of physical properties

In chloride containing environments, two metals in physical contact can undergo galvanic corrosion limiting the lifetime of components. Being able to accurately predict galvanic corrosion damage distributions over time has not been widely presented in literature. Therefore, Finite Element Method (FEM) corrosion models were experimentally validated for two galvanic couples as a function of governing equations, environment, anode material, anode:cathode ratio, and time. Carbon steel/stainless steel (CS/SS) and zinc/stainless steel (Zn/SS) galvanic couples were exposed to NaCl solutions at room temperatures for up to 14 days. For the galvanic couples and environments, the Laplace equation with variable conductivity and reactions was sufficient to model the experimental corrosion damage. Increasing the chloride concentration for the CS/SS galvanic couple, regardless of the anode:cathode ratio, decreased the observed and modeled corrosion damage. Decreasing the anode:cathode ratio (i.e., increasing the cathode length), increased the experimentally observed and modeled corrosion damage. For small anode:cathode ratios, the governing equations deviate over long time periods with the Nernst-Plank equation being conservative. For the Zn/SS galvanic couple, the cathode length controls the dominant cathodic reduction reaction. For small cathode lengths, the hydrogen evolution reaction is dominant. For larger cathode lengths, the oxygen reduction reaction is dominant. The results are discussed with regard to the influence of solution chemistry, ohmic drop, and governing reactions. Overall, validated FEM models were presented, and the resultant models, physics, and mechanisms can be applied to other corrosion scenarios with confidence.

Carbon steel↗

Study, Development, and Design of Replaceable Shear Yielding Steel Panel Damper

For middle-high rise buildings, vibration controlled structures to reduce the damage of main frames are recently becoming general in Japan. A steel material damper is low price and excellent in the energy absorption efficiency at a large earthquake. Though the exchange of the dampers are necessary when an excessive accumulation of plasticity deformation occurs, a steel material damping system, which received an excessive accumulation of plasticity deformation after a large earthquake, can recover a seismic-proof performance and property value of the building after the replacement. In the paper, shear yielding steel panel dampers installed in the web of a beam connected with high tension bolt joint is introduced. This damper is made of low-yield point steel, and the advantages of this system are low cost, easy-production and easy-replacement. For this steel panel damper, the finite element method (FEM) analysis using the shell element model adjusted to 1/2 of 6.4 m beam span is executed to make the design most effective. Yielding property of the beam installing this damper, shape of the splice plate and the bolt orientation for the connecting are examined in this analysis. As a result, we found that the plastic strain extends uniformly to the entire damping panel when making the splice plate a trapezoidal shape. The basic performance confirmation examination was also done using the real scale examination model besides the FEM analysis, and the performance of the system was confirmed. In addition, design of a high rise building in which the steel shear-yielding panel dampers and oil dampers were adopted without disturbing an architectural plan is also introduced.

58 GEOSCIENCES↗

Validating corrosion models: A comparison of governing equations

Experimental validation of Finite Element Method (FEM) models varying electrochemical governing equations, inclusion of chemical reactions, and time on the resultant damage profile for two galvanic couples is explored. Two anode materials (Magnesium AZ31 and Carbon Steel) in contact with a cathode (Stainless Steel 304 L) were modeled in/exposed to NaCl (1 and 0.1 M respectively for the anode materials) for up to one week. The physics approach, inclusion of chemical reactions, and the boundary conditions required to accurately represent the damage profile in FEM models depended on the galvanic couple materials and, ultimately, the corrosion rate. For high rates of corrosion (i.e., magnesium anode), the Nernst-Planck equation with Electroneutrality was sufficient to describe the damage, while, for low rates of corrosion (i.e., carbon steel anode), the Laplace equation was sufficient. In all cases, the most complete governing equation (Nernst-Planck-Poisson Equation) was not necessary to accurately describe the damage. Precipitation reactions in solution also played a critical role in the predicted damage profile, especially for high corrosion rate systems. Finally, for short time periods (< 6 h), the choice of governing equations does not significantly influence damage profile results. Overall, the choice of physics to reduce error in simulations relies on the boundary conditions, geometry, conductivity of the solution, electrochemical potential differences, and time of exposure. The above results are discussed with regard to accuracy and computational savings.

Carbon steel↗

A modified moment-fitted integration scheme for X-FEM applications with history-dependent material data

Here, we present a strategy for the numerical integration of partial elements with the eXtended finite element method (X-FEM). The new strategy is specifically designed for problems with propagating cracks through a bulk material that exhibits inelasticity. Following a standard approach with the X-FEM, as the crack propagates into new regions of the domain, elements are split into several copies that contain pieces of the domain on either side of the crack. We examine quadrature rules that have sufficient accuracy to calculate stiffness matrices regardless of the orientation of the crack with respect to the element. This permits the number of integration points within elements to remain constant as a crack propagates, and for state data to be easily transferred between successive discretizations. In order to maintain weights that are strictly positive, we propose an approach that blends moment-fitted weights with volume-fraction based weights. To demonstrate the efficacy of this simple approach, we present results from numerical tests and examples with both elastic and plastic material response.

42 ENGINEERING↗

Development of a graphite probe calorimeter for absolute clinical dosimetry

The aim of this work is to present the numerical design optimization, construction, and experimental proof of concept of a graphite probe calorimeter (GPC) conceived for dose measurement in the clinical environment (U.S. provisional patent 61/652,540). A finite element method (FEM) based numerical heat transfer study was conducted using a commercial software package to explore the feasibility of the GPC and to optimize the shape, dimensions, and materials used in its design. A functioning prototype was constructed inhouse and used to perform dose to water measurements under a 6 MV photon beam at 400 and 1000 MU/min, in a thermally insulated water phantom. Heat loss correction factors were determined using FEM analysis while the radiation field perturbation and the graphite to water absorbed dose conversion factors were calculated using Monte Carlo simulations. The difference in the average measured dose to water for the 400 and 1000 MU/min runs using the TG-51 protocol and the GPC was 0.2% and 1.2%, respectively. Heat loss correction factors ranged from 1.001 to 1.002, while the product of the perturbation and dose conversion factors was calculated to be 1.130. The combined relative uncertainty was estimated to be 1.4%, with the largest contributors being the specific heat capacity of the graphite (type B, 0.8%) and the reproducibility, defined as the standard deviation of the mean measured dose (type A, 0.6%). By establishing the feasibility of using the GPC as a practical clinical absolute photon dosimeter, this work lays the foundation for further device enhancements, including the development of an isothermal mode of operation and an overall miniaturization, making it potentially suitable for use in small and composite radiation fields. It is anticipated that, through the incorporation of isothermal stabilization provided by temperature controllers, a subpercent overall uncertainty will be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U-10Mo/Zr Interface Modeling using a Microstructure-Based FEM Approach

The U-10Mo in low enrichments (LEU) has been identified as the most promising alternative to the current highly enriched uranium (HEU) used in the United States’ fleet of high performance research reactors (USHPRRs). The nominal configuration of the new LEU U-10Mo plate fuel comprises a U-10Mo fuel foil enriched to slightly less than 20% U-235 (0.08” to 0.02” thick), a thin Zr interlayer/diffusion barrier (25 m thick) and a relatively thick outer can of 6061 aluminum. Currently, the Zr interlayer is clad by hot roll bonding. Previous studies and observations revealed a thinning of the zirconium (Zr) layer during this fuel fabrication process, which is not desirable from the fuel performance perspective. Coarse UMo grains, dendritic structures, Mo concentration segregation, carbides, and porosity are present in the as-cast material and can lead to a nonuniform UMo/Zr interface. The purpose of the current work is to investigate the effects of these microstructural parameters on the Zr coating variation. A microstructure-based finite-element method model was used in this work, and a study on the effect of homogenization on the interface between U-10Mo and Zr was conducted. The model uses actual backscattered electron–scanning electron microscopy microstructures, Mo concentrations, and mechanical properties to predict the behavior of a representative volume element under compressive loading during the rolling process. The model successfully predicted the experimentally observed thinning of the Zr layer in the as-cast material. The model also uses results from a homogenization model as an input, and a study on the effect of different levels of homogenization on the interface indicated that homogenization helps decrease this thinning. This model can be considered a predictive tool representing a first step for model integration and an input into a larger fuel fabrication performance model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility of producing a short, high energy s-band linear accelerator using a klystron power source

Purpose: To use a finite-element method (FEM) model to study the feasibility of producing a short s-band (2.9985 GHz) waveguide capable of producing x-rays energies up to 10 MV, for applications in a linac-MR, as well as conventional radiotherapy. Methods: An existing waveguide FEM model developed by the authors' group is used to simulate replacing the magnetron power source with a klystron. Peak fields within the waveguide are compared with a published experimental threshold for electric breakdown. The RF fields in the first accelerating cavity are scaled, approximating the effect of modifications to the first coupling cavity. Electron trajectories are calculated within the RF fields, and the energy spectrum, beam current, and focal spot of the electron beam are analyzed. One electron spectrum is selected for Monte Carlo simulations and the resulting PDD compared to measurement. Results: When the first cavity fields are scaled by a factor of 0.475, the peak magnitude of the electric fields within the waveguide are calculated to be 223.1 MV/m, 29% lower than the published threshold for breakdown at this operating frequency. Maximum electron energy increased from 6.2 to 10.4 MeV, and beam current increased from 134 to 170 mA. The focal spot FWHM is decreased slightly from 0.07 to 0.05 mm, and the width of the energy spectrum increased slightly from 0.44 to 0.70 MeV. Monte Carlo results show d{sub max} is at 2.15 cm for a 10 Multiplication-Sign 10 cm{sup 2} field, compared with 2.3 cm for a Varian 10 MV linac, while the penumbral widths are 4.8 and 5.6 mm, respectively. Conclusions: The authors' simulation results show that a short, high-energy, s-band accelerator is feasible and electric breakdown is not expected to interfere with operation at these field strengths. With minor modifications to the first coupling cavity, all electron beam parameters are improved.

60 APPLIED LIFE SCIENCES↗

Simulated effects of sample size and grain neighborhood on the modeling of extreme value fatigue response

Assessing the size of representative volume elements (RVEs) for fatigue-related applications is challenging. A RVE relevant to random microstructure requires a volume of material that is sufficiently large to capture the grain/phase heterogeneity that captures all statistical moments of the distribution of the driving force for fatigue crack formation at “hot spot” grains. Consequently, the large size of a microstructure RVE required to study fatigue phenomena is largely computationally intractable and difficult to explore. A more realistic objective in this work is to systematically study, as a function of the size of a statistical sample of microstructure, trends towards convergence of the simulated distribution of driving force for fatigue crack formation. Our present work accordingly leverages the recently developed open-source PRISMS-Fatigue framework to examine the trends in convergence of extreme value distributions (EVD) of Fatigue Indicator Parameters (FIPs) in progressively larger polycrystalline microstructure realizations of FCC Al alloy 7075-T6 using crystal plasticity finite element method simulations. The results are compared to the traditional method in which ensembles of statistical volume elements (SVEs) are simulated to build up statistics intended to approximate those associated with a larger volume of material. The convergence of EVDs with increase of size of a SVE of microstructure is closely related to the extent of grain nearest neighbor (NN) interactions. Accordingly, the sensitivity of the local micromechanical response at hot spot grains is quantitatively investigated by systematically varying the orientations of NN grains. Results indicate that SVEs with cubic crystallographic texture tend towards convergence of the EVD of FIPs with tens of thousands of grains while the random and rolled textures require larger volumes. Simple relationships based on microstructure parameters (e.g., Schmid Factor, grain size, NN misorientation) do not completely correlate to fatigue hot spot grains. Finally, the sensitivity of the extreme value fatigue response at hot spot grains extends to the 3rd NN when a single neighborhood grain orientation is altered.

36 MATERIALS SCIENCE↗

Two-Dimensional Computational Fluid Dynamics and Conduction Simulations of Heat Transfer in Horizontal Window Frames with Internal Cavities

This paper assesses the accuracy of the simplified frame cavity conduction/convection and radiation models presented in ISO 15099 and used in software for rating and labeling window products. Temperatures and U-factors for typical horizontal window frames with internal cavities are compared; results from Computational Fluid Dynamics (CFD) simulations with detailed radiation modeling are used as a reference. Four different frames were studied. Two were made of polyvinyl chloride (PVC) and two of aluminum. For each frame, six different simulations were performed, two with a CFD code and four with a building-component thermal-simulation tool using the Finite Element Method (FEM). This FEM tool addresses convection using correlations from ISO 15099; it addressed radiation with either correlations from ISO 15099 or with a detailed, view-factor-based radiation model. Calculations were performed using the CFD code with and without fluid flow in the window frame cavities; the calculations without fluid flow were performed to verify that the CFD code and the building-component thermal-simulation tool produced consistent results. With the FEM-code, the practice of subdividing small frame cavities was examined, in some cases not subdividing, in some cases subdividing cavities with interconnections smaller than five millimeters (mm) (ISO 15099) and in some cases subdividing cavities with interconnections smaller than seven mm (a breakpoint that has been suggested in other studies). For the various frames, the calculated U-factors were found to be quite comparable (the maximum difference between the reference CFD simulation and the other simulations was found to be 13.2 percent). A maximum difference of 8.5 percent was found between the CFD simulation and the FEM simulation using ISO 15099 procedures. The ISO 15099 correlation works best for frames with high U-factors. For more efficient frames, the relative differences among various simulations are larger. Temperature was also compared, at selected locations on the frames. Small differences was found in the results from model to model. Finally, the effectiveness of the ISO cavity radiation algorithms was examined by comparing results from these algorithms to detailed radiation calculations (from both programs). Our results suggest that improvements in cavity heat transfer calculations can be obtained by using detailed radiation modeling (i.e. view-factor or ray-tracing models), and that incorporation of these strategies may be more important for improving the accuracy of results than the use of CFD modeling for horizontal cavities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling quasi-static poroelastic propagation using an asymptotic approach

Since the formulation of poroelasticity (Biot(1941)) and its reformulation (Rice & Cleary(1976)), there have been many efforts to solve the coupled system of equations. Perhaps because of the complexity of the governing equations, most of the work has been directed towards finding numerical solutions. For example, Lewis and co-workers published early papers (Lewis & Schrefler(1978); Lewis et al.(1991)Lewis, Schrefler, & Simoni) concerned with finite-element methods for computing consolidation, subsidence, and examining the importance of coupling. Other early work dealt with flow in a deformable fractured medium (Narasimhan & Witherspoon 1976); Noorishad et al.(1984)Noorishad, Tsang, & Witherspoon. This effort eventually evolved into a general numerical approach for modeling fluid flow and deformation (Rutqvist et al.(2002)Rutqvist, Wu, Tsang, & Bodvarsson). As a result of this and other work, numerous coupled, computer-based algorithms have emerged, typically falling into one of three categories: one-way coupling, loose coupling, and full coupling (Minkoff et al.(2003)Minkoff, Stone, Bryant, Peszynska, & Wheeler). In one-way coupling the fluid flow is modeled using a conventional numerical simulator and the resulting change in fluid pressures simply drives the deformation. In loosely coupled modeling distinct geomechanical and fluid flow simulators are run for a sequence of time steps and at the conclusion of each step information is passed between the simulators. In full coupling, the fluid flow and geomechanics equations are solved simultaneously at each time step (Lewis & Sukirman(1993); Lewis & Ghafouri(1997); Gutierrez & Lewis(2002)). One disadvantage of a purely numerical approach to solving the governing equations of poroelasticity is that it is not clear how the various parameters interact and influence the solution. Analytic solutions have an advantage in that respect; the relationship between the medium and fluid properties is clear from the form of the solution. Unfortunately, analytic solutions are only available for highly idealized conditions, such as a uniform (Rudnicki(1986)) or one-dimensional (Simon et al.(1984)Simon, Zienkiewicz, & Paul; Gajo & Mongiovi(1995); Wang & Kumpel(2003)) medium. In this paper I derive an asymptotic, semi-analytic solution for coupled deformation and flow. The approach is similar to trajectory- or ray-based methods used to model elastic and electromagnetic wave propagation (Aki & Richards(1980); Kline & Kay(1979); Kravtsov & Orlov(1990); Keller & Lewis(1995)) and, more recently, diffusive propagation (Virieux et al.(1994)Virieux, Flores-Luna, & Gibert; Vasco et al.(2000)Vasco, Karasaki, & Keers; Shapiro et al.(2002)Shapiro, Rothert, Rath, & Rindschwentner; Vasco(2007)). The asymptotic solution is valid in the presence of smoothly-varying, heterogeneous flow properties. The situation I am modeling is that of a formation with heterogeneous flow properties and uniform mechanical properties. The boundaries of the layer may vary arbitrary and can define discontinuities in both flow and mechanical properties. Thus, using the techniques presented here, it is possible to model a stack of irregular layers with differing mechanical properties. Within each layer the hydraulic conductivity and porosity can vary smoothly but with an arbitrarily large magnitude. The advantages of this approach are that it produces explicit, semi-analytic expressions for the arrival time and amplitude of the Biot slow and fast waves, expressions which are valid in a medium with heterogeneous properties. As shown here, the semi-analytic expressions provide insight into the nature of pressure and deformation signals recorded at an observation point. Finally, the technique requires considerably fewer computer resources than does a fully numerical treatment.

54 ENVIRONMENTAL SCIENCES↗

Computer Aided Multi-scale Design of SiC-Si3N4 Nanoceramic Composites for High-Temperature Structural Applications

It is estimated that by using better and improved high temperature structural materials, the power generation efficiency of the power plants can be increased by 15% resulting in significant cost savings. One such promising material system for future high-temperature structural applications in power plants is Silicon Carbide-Silicon Nitride (SiC-Si{sub 3}N{sub 4}) nanoceramic matrix composites. The described research work focuses on multiscale simulation-based design of these SiC-Si{sub 3}N{sub 4} nanoceramic matrix composites. There were two primary objectives of the research: (1) Development of a multiscale simulation tool and corresponding multiscale analyses of the high-temperature creep and fracture resistance properties of the SiC-Si{sub 3}N{sub 4} nanocomposites at nano-, meso- and continuum length- and timescales; and (2) Development of a simulation-based robust design optimization methodology for application to the multiscale simulations to predict the range of the most suitable phase morphologies for the desired high-temperature properties of the SiC-Si{sub 3}N{sub 4} nanocomposites. The multiscale simulation tool is based on a combination of molecular dynamics (MD), cohesive finite element method (CFEM), and continuum level modeling for characterizing time-dependent material deformation behavior. The material simulation tool is incorporated in a variable fidelity model management based design optimization framework. Material modeling includes development of an experimental verification framework. Using material models based on multiscaling, it was found using molecular simulations that clustering of the SiC particles near Si{sub 3}N{sub 4} grain boundaries leads to significant nanocomposite strengthening and significant rise in fracture resistance. It was found that a control of grain boundary thicknesses by dispersing non-stoichiometric carbide or nitride phases can lead to reduction in strength however significant rise in fracture strength. The temperature dependent strength and microstructural stability was also significantly depended upon the dispersion of new phases at grain boundaries. The material design framework incorporates high temperature creep and mechanical strength data in order to develop a collaborative multiscale framework of morphology optimization. The work also incorporates a computer aided material design dataset development procedure where a systematic dataset on material properties and morphology correlation could be obtained depending upon a material processing scientist's requirements. Two different aspects covered under this requirement are: (1) performing morphology related analyses at the nanoscale and at the microscale to develop a multiscale material design and analyses capability; (2) linking material behavior analyses with the developed design tool to form a set of material design problems that illustrate the range of material design dataset development that could be performed. Overall, a software based methodology to design microstructure of particle based ceramic nanocomposites has been developed. This methodology has been shown to predict changes in phase morphologies required for achieving optimal balance of conflicting properties such as minimal creep strain rate and high fracture strength at high temperatures. The methodology incorporates complex material models including atomistic approaches. The methodology will be useful to design materials for high temperature applications including those of interest to DoE while significantly reducing cost of expensive experiments.

36 MATERIALS SCIENCE↗

Analysis of breathing cracks using vibrations

The influence of half-ellipse-shaped fatigue cracks and machined through-thickness cuts on the impact response of cantilever beam samples were analysed using the Finite Element Method and compared to experimental data for different crack depths. The effect of sample width was analysed for geometries with fatigue cracks (aspect ratio a/c = 0.45) and through-thickness cuts (rectangular cracks). The differences between both types of damage were analysed numerically and experimentally. The effect of sample width was studied and it was found that the behaviour of the cantilever with a fatigue-crack approaches that of the saw cut sample when the fatigue crack reaches the edges of the test piece. Acceleration data were analysed using the Fast Fourier Transform algorithm and Power Density Spectra (PSD) were obtained. For fatigue-cracked samples, harmonics of the frequencies of natural modes of oscillation were found. Analytical modelling was done using a mass-spring-damper system for studying the bilinear behaviour of the stiffness element. Harmonics found were assigned to the breathing behaviour of the crack. The detection threshold using frequency shifts inspection was twice as high as using spectral analysis. This would allow crack detection at half of the fatigue life of the specimen.

42 ENGINEERING↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

Superconvergence analysis for nonlinear parabolic equation with EQ{sub 1}{sup rot} nonconforming finite element

EQ{sub 1}{sup rot} nonconforming finite element method (FEM) applied to a class of nonlinear parabolic equation is discussed. First, by use of two typical characters of this element (one is that the associated FE interpolation operator is identical to its traditional Ritz projection operator; the other is that the consistency error is of order O(h{sup 2}), one order higher than the interpolation error, when the exact solution of the problems belongs to H{sup 3}(Ω)), the supercloseness of order O(h{sup 2}) in broken H{sup 1}-norm for semi-discrete scheme is obtained without the boundedness of numerical solution in L{sup ∞}-norm through splitting the numerical solution into several parts. Moreover, we get the desired result with requirement of u,u{sub t}∈H{sup 3}(Ω) only. Secondly, a linearized Crank–Nicolson fully discrete scheme is proposed and the superclose property of order O(h{sup 2}+τ{sup 2}) is derived by constructing a suitable auxiliary problem. Finally, a numerical example is carried out to confirm our theoretical analysis. Here, h is the subdivision parameter and τ is the time step.

97 MATHEMATICS AND COMPUTING↗

Nonnegative methods for bilinear discontinuous differencing of the S N equations on quadrilaterals

Historically, matrix lumping and ad hoc flux fixups have been the only methods used to eliminate or suppress negative angular flux solutions associated with the unlumped bilinear discontinuous (UBLD) finite element spatial discretization of the two-dimensional S N equations. Though matrix lumping inhibits negative angular flux solutions of the S N equations, it does not guarantee strictly positive solutions. In this paper, we develop and define a strictly nonnegative, nonlinear, Petrov-Galerkin finite element method that fully preserves the bilinear discontinuous spatial moments of the transport equation. Additionally, we define two ad hoc fixups that maintain particle balance and explicitly set negative nodes of the UBLD finite element solution to zero but use different auxiliary equations to fully define their respective solutions. We assess the ability to inhibit negative angular flux solutions and the accuracy of every spatial discretization that we consider using a glancing void test problem with a discontinuous solution known to stress numerical methods. Though significantly more computationally intense, the nonlinear Petrov-Galerkin scheme results in a strictly nonnegative solution and is a more accurate solution than all the other methods considered. One fixup, based on shape preserving, results in a strictly nonnegative final solution but has increased numerical diffusion relative to the Petrov-Galerkin scheme and is less accurate than the UBLD solution. The second fixup, which preserves as many spatial moments as possible while setting negative values of the unlumped solution to zero, is less accurate than the Petrov-Galerkin scheme but is more accurate than the other fixup. However, it fails to guarantee a strictly nonnegative final solution. As a result, the fully lumped bilinear discontinuous finite element solution is the least accurate method, with significantly more numerical diffusion than the Petrov-Galerkin scheme and both fixups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Effect of Data Transformations on Scalar Field Topological Analysis of High-Order FEM Solutions

High-order finite element methods (HO-FEM) are gaining popularity in the simulation community due to their success in solving complex flow dynamics. There is an increasing need to analyze the data produced as output by these simulations. Simultaneously, topological analysis tools are emerging as powerful methods for investigating simulation data. Yet, most of the current approaches to topological analysis have had limited application to HO-FEM simulation data for two reasons. First, the current topological tools are designed for linear data (polynomial degree one), but the polynomial degree of the data output by these simulations is typically higher (routinely up to polynomial degree six). Second, the simulation data and derived quantities of the simulation data have discontinuities at element boundaries, and these discontinuities do not match the input requirements for the topological tools. One solution to both issues is to transform the high-order data to achieve low-order, continuous inputs for topological analysis. Nevertheless, there has been little work evaluating the possible transformation choices and their downstream effect on the topological analysis. We perform an empirical study to evaluate two commonly used data transformation methodologies along with the recently introduced L-SIAC filter for processing high-order simulation data. Our findings indicate diverse behaviors are possible. We offer some guidance about how best to consider a pipeline of topological analysis of HO-FEM simulations with the currently available implementations of topological analysis.

97 MATHEMATICS AND COMPUTING↗

Exact sub-grid interface correction schemes for elliptic interface problems

We introduce a non-conforming finite element method for second order elliptic interface problems. Our approach applies to problems in which discontinuous coefficients and singular sources on the interface may give rise to jump discontinuities in either the solution or its normal derivative. Given a standard background mesh and an interface that passes between elements, the key idea is to construct a singular correction function which satisfies the prescribed jump conditions, providing accurate sub-grid resolution of the discontinuities. Utilizing the closest point extension and an implicit interface representation by the signed distance function, an algorithm is established to construct the correction function. The result is a function which is supported only on the interface elements, represented by the regular basis functions, and bounded independently of the interface location with respect to the background mesh. In the particular case of a constant second order coefficient, our regularization by singular function is straightforward, and the resulting left-hand-side is identical to that of a regular problem without introducing any instability. The influence of the regularization appears solely on the right-hand-side, which simplifies the implementation. In the more general case of discontinuous second order coefficients, a normalization is invoked which introduces a constraint equation on the interface. This results in a problem statement similar to that of a saddle-point problem. We employ two-level-iteration as the solution strategy, which exhibits aspects similar to those of iterative preconditioning strategies.

97 MATHEMATICS AND COMPUTING↗

Impact of the MLC on the MRI field distortion of a prototype MRI-linac

Purpose: To cope with intrafraction tumor motion, integrated MRI-linac systems for real-time image guidance are currently under development. The multileaf collimator (MLC) is a key component in every state-of-the-art radiotherapy treatment system, allowing for accurate field shaping and tumor tracking. This work quantifies the magnetic impact of a widely used MLC on the MRI field homogeneity for such a modality.Methods: The finite element method was employed to model a MRI-linac assembly comprised of a 1.0 T split-bore MRI magnet and the key ferromagnetic components of a Varian Millennium 120 MLC, namely, the leaves and motors. Full 3D magnetic field maps of the system were generated. From these field maps, the peak-to-peak distortion within the MRI imaging volume was evaluated over a 30 cm diameter sphere volume (DSV) around the isocenter and compared to a maximum preshim inhomogeneity of 300 μT. Five parametric studies were performed: (1) The source-to-isocenter distance (SID) was varied from 100 to 200 cm, to span the range of a compact system to that with lower magnetic coupling. (2) The MLC model was changed from leaves only to leaves with motors, to determine the contribution to the total distortion caused by MLC leaves and motors separately. (3) The system was configured in the inline or perpendicular orientation, i.e., the linac treatment beam was oriented parallel or perpendicular to the magnetic field direction. (4) The treatment field size was varied from 0 × 0 to 20×20 cm{sup 2}, to span the range of clinical treatment fields. (5) The coil currents were scaled linearly to produce magnetic field strengths B{sub 0} of 0.5, 1.0, and 1.5 T, to estimate how the MLC impact changes with B{sub 0}.Results: (1) The MLC-induced MRI field distortion fell continuously with increasing SID. (2) MLC leaves and motors were found to contribute to the distortion in approximately equal measure. (3) Due to faster falloff of the fringe field, the field distortion was generally smaller in the perpendicular beam orientation. The peak-to-peak DSV distortion was below 300 μT at SID≥130 cm (perpendicular) and SID≥140 cm (inline) for the 1.0 T design. (4) The simulation of different treatment fields was identified to cause dynamic changes in the field distribution. However, the estimated residual distortion was below 1.2 mm geometric distortion at SID≥120 cm (perpendicular) and SID≥130 cm (inline) for a 10 mT/m frequency-encoding gradient. (5) Due to magnetic saturation of the MLC materials, the field distortion remained constant at B{sub 0}>1.0 T.Conclusions: This work shows that the MRI field distortions caused by the MLC cannot be ignored and must be thoroughly investigated for any MRI-linac system. The numeric distortion values obtained for our 1.0 T magnet may vary for other magnet designs with substantially different fringe fields, however the concept of modest increases in the SID to reduce the distortion to a shimmable level is generally applicable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗