Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A Novel Fault Diagnosis Approach for Rolling Bearing Based on CWT and Adaptive Sparse Representation

Extraction and enhancement of weak impulse signature is the key of rolling bearing fault prognostics in which case the features are often weak and covered by noise. Tunable Q-factor wavelet transform (TQWT), as an emerging wavelet construction theory developed in a frequency domain explicitly, has the advantages of matching with the specific oscillation behavior of signal components. In this article, an adaptive sparse representation (ASR) method is proposed, which integrates the sparse code shrinkage (SCS) and parameter optimization into TQWT. However, direct application of ASR is difficult to extract fault signatures at the early stage or low-speed operation due to weak fault symptoms and background noise. A novel fault diagnosis strategy based on continuous wavelet transform (CWT) and ASR is investigated. CWT owns significant advantages on multiscale subdivision and weak signal detection. The results of simulated and experimental vibration signal analyses verify the effectiveness of the proposed method in accurately extracting weak impulse features from the noise environment.

Yuan, Xing↗

SAFIRE : Scalable and Accurate Fault Injection for Parallel Multi-threaded Applications

The software SAFIRE implements a fault injection tool to evaluate the impact of soft errors on parallel, multi-threaded applications. It implements instruction-level fault models that emulate soft errors by flipping bits in the register operands of executed machine instructions. SAFIRE is based on the LLVM compiler and utilizes novel techniques to optimize instruction instrumentation and fault injection. By detailed measurements, SAFIRE is multiple times faster than other state-of-the-art fault injection techniques, while having the same accuracy.

Georgakoudis, Giorgis↗

TFDA (Transient Fault Detection Algorithm) [SWR-24-23]

The Transient Fault Detection Algorithm (TFDA) is an algorithm to detect the non-fault and transient fault conditions, and classify the fault types. This is part of OEDI-SI project (https://data.openei.org/search?q=oedi%20si).

Hao, Jun↗

Multivariate Time Series Intermittent Fault Detectionin Controller Area Network CAN

Fault detection in Controller Area Network (CAN) systems is crucial for ensuring the reliability and safety of automotive and industrial applications. This study investigates and compares the effectiveness of time series classification models for supervised fault detection in CAN data. This repository contains the code and data for our benchmarking experiment aimed at detecting intermittent faults in automotive Controller Area Network (CAN) data. The goal of this project is to compare various machine learning (ML) and deep learning (DL) models using different Time Series Cross-Validation (TSCV) techniques to evaluate their effectiveness in a streaming environment for fault detection.

Hespeler, Steven [Oak Ridge National Laboratory (O↗

Coupling of regional geophysics and local soil-structure models in the EQSIM fault-to-structure earthquake simulation framework

Accurate understanding and quantification of the risk to critical infrastructure posed by future large earthquakes continues to be a very challenging problem. Earthquake phenomena are quite complex and traditional approaches to predicting ground motions for future earthquake events have historically been empirically based whereby measured ground motion data from historical earthquakes are homogenized into a common data set and the ground motions for future postulated earthquakes are probabilistically derived based on the historical observations. This procedure has recognized significant limitations, principally due to the fact that earthquake ground motions tend to be dictated by the particular earthquake fault rupture and geologic conditions at a given site and are thus very site-specific. Historical earthquakes recorded at different locations are often only marginally representative. There has been strong and increasing interest in utilizing large-scale, physics-based regional simulations to advance the ability to accurately predict ground motions and associated infrastructure response. However, the computational requirements for simulations at frequencies of engineering interest have proven a major barrier to employing regional scale simulations. In a U.S. Department of Energy Exascale Computing Initiative project, the EQSIM application development is underway to create a framework for fault-to-structure simulations. This framework is being prepared to exploit emerging exascale platforms in order to overcome computational limitations. This article presents the essential methodology and computational workflow employed in EQSIM to couple regional-scale geophysics models with local soil-structure models to achieve a fully integrated, complete fault-to-structure simulation framework. Here, the computational workflow, accuracy and performance of the coupling methodology are illustrated through example fault-to-structure simulations.

97 MATHEMATICS AND COMPUTING↗

Temporal and spatial characterization of a thermogenic, fault-controlled gas hydrate system, Woolsey Mound, Gulf of Mexico

Woolsey Mound, located at Mississippi Canyon Lease Block 118 (MC118), is the site of the Gulf of Mexico hydrate research consortium’s seafloor observatory, where gas hydrates outcrop at the seafloor. The presence of gas hydrates in the mound is confirmed directly by coring and indirectly by 3D seismic reflection data. Craters, pockmarks, chemosynthetic communities, and authigenic carbonates populate the seafloor at Woolsey Mound. Each crater is characterized by a network of shallow crestal faults that connect the hydrate mound to the underlying allochthonous salt body. We characterize the temporal and spatial evolution of gas hydrates at Woolsey Mound under natural perturbations using four collocated 3D seismic reflection data sets that span over 14 years. Data acquisition differences embedded in the data sets arising from variation in geometry, sample rate, and phase are minimized using the “cross-equalization” method. Our results indicate that hydrate formation and dissociation vary temporally and spatially in close connection to the shallow crestal faults. Evidence of gas hydrate dissociation is observed over a period of three years (2000–2003), where major dissociation occurred along the southern portion of the crestal fault in the southeast crater. The dissociation is less prominent in the southwest crater. Evidence of methane venting is observed between 2000 and 2010, which is mostly concentrated in the southeast crater. The residual amplitude anomalies observed between 2000 and 2014 in the mound are mostly positive, implying that the methane venting had increased significantly. The positive anomalies are correlated with the methane seepage recorded in 2011. Our results indicate the evolution of a fault-controlled gas hydrate system in the northern Gulf of Mexico, which would aid in assessing its impact on the seafloor.

Geochemistry & Geophysics↗

Coupled Geomechanical Modeling to Assess Cap Rock Integrity and Mechanical Fault Stability: Application to Farnsworth Field Unit Project

Abstract The SWP project is located in a mature waterflood undergoing conversion to CO2-WAG operations in the Farnsworth, Texas, USA. Anthropogenic CO2 is sourced from a fertilizer and an ethanol plant. This work utilizes Farnsworth’s full-field, history-matched, compositional hydrodynamic coupled geomechanical model for assessing the impact of stress changes observed through the history matched field life. Production and injection induced stress changes, fault stability and caprock integrity investigations are performed to project the potential for fault reactivation and the loss of caprock integrity under shear failure. A static mechanical earth model (MEM) was constructed for use in transient coupled geomechanical model based on the existing Southwest Regional Partnership (SWP) geological model. The static MEM inherits the stratigraphic and structural features of the geologic model and incorporates additional overburden, underburden, and sideburden formations required to impose mechanical boundary conditions. Mechanical properties were distributed in the 3D MEM through integration of geophysical logs and 3-dimensional seismic elastic inversion properties using a combination of Bayesian and stochastic interpolation methods. These data are further enhanced by lab derived strength and failure criteria for the caprock interval. Additionally, interpreted faults and other geological features were included as part of the static structural framework to fully represent subsurface hydraulic and mechanical systems and appropriately integrate heterogeneity. Two-way coupling of hydrodynamic flow and geomechanical simulations incorporates the Kozeny-Carman relationship for updating permeability and is history matched through primary, secondary (waterflooding) and tertiary (CO2 WAG) recovery periods before performing a twenty year forecast. Two-way simulations are performed to understand the effective stress perturbations imposed by field operations: water injection and the more recent implementation of WAG. Evaluation of Mohr circles with liquid production and field pressure charts as well as slip tendency and distance to failure metrics indicate that neither our faults or cap rock are critically stressed. This paper presents the results of the Farnsworth initial attempts to integrate the seismic driven 3D MEM into coupled hydrodynamic geomechanical history match simulation workflow.

02 PETROLEUM↗

Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters

Zenergy Power has successfully designed, built, tested, and installed in the US electrical grid a saturable reactor Fault Current Limiter. Beginning in 2007, first as SC Power Systems and from 2008 as Zenergy Power, Inc., ZP used DOE matching grant and ARRA funds to help refine the design of the saturated reactor fault current limiter. ZP ultimately perfected the design of the saturated reactor FCL to the point that ZP could reliably design a suitable FCL for most utility applications. Beginning with a very basic FCL design using 1G HTS for a coil housed in a LN2 cryostat for the DC bias magnet, the technology progressed to a commercial system that was offered for sale internationally. Substantial progress was made in two areas. First, the cryogenics cooling system progressed from a sub-cooled liquid nitrogen container housing the HTS coils to cryostats utilizing dry conduction cooling and reaching temperatures down to less than 20 degrees K. Large, round cryostats with warm bore diameters of 1.7 meters enabled the design of large tanks to hold the AC components. Second, the design of the AC part of the FCL was refined from a six legged spider design to a more compact and lighter design with better fault current limiting capability. Further refinement of the flux path and core shape led to an efficient saturated reactor design requiring less Ampere-turns to saturate the core. In conclusion, the development of the saturable reactor FCL led to a more efficient design not requiring HTS magnets and their associated peripheral equipment, which yielded a more economical product in line with the electric utility industry expectations. The original goal for the DOE funding of the ZP project Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters was to stimulate the HTS wire industry with, first 1G, then 2G, HTS wire applications. Over the approximately 5 years of ZP's product development program, the amount of HTS wire employed per FCL and its cost as a percentage of the total FCL product content had not dropped substantially from an unsustainable level of more than 50% of the total cost of the FCL, nor had the availability increased (today the availability of 2G wire for commercial applications outside of specific partnerships with the leading 2G wire manufacturers is extremely limited). ZP had projected a very significant commercial potential for FCLs with higher performance and lower costs compared to the initial models built with 1G wire, which would come about from the widespread availability of low-cost, high-performance 2G HTS wire. The potential for 2G wires at greatly reduced performance-based prices compared to 1G HTS conductor held out the potential for the commercial production of FCLs at price and performance levels attractive to the utility industry. However, the price of HTS wire did not drop as expected and today the available quantities of 2G wire are limited, and the price is higher than the currently available supplies of 1G wire. The commercial option for ZP to provide a reliable and reasonably priced FCL to the utility industry is to employ conventional resistive conductor DC electromagnets to bias the FCL. Since the premise of the original funding was to stimulate the HTS wire industry and ZP concluded that copper-based magnets were more economical for the foreseeable future, DOE and ZP decided to mutually terminate the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary photovoltaic arc-fault prognostic tests using sacrificial fiber optic cabling.

Through the New Mexico Small Business Assistance Program, Sandia National Laboratories worked with Sentient Business Systems, Inc. to develop and test a novel photovoltaic (PV) arc-fault detection system. The system operates by pairing translucent polymeric fiber optic sensors with electrical circuitry so that any external abrasion to the system or internal heating causes the fiber optic connection to fail or detectably degrade. A periodic pulse of light is sent through the optical path using a transmitter-receiver pair. If the receiver does not detect the pulse, an alarm is sounded and the PV system can be de-energized. This technology has the unique ability to prognostically determine impending failures to the electrical system in two ways: (a) the optical connection is severed prior to physical abrasion or cutting of PV DC electrical conductors, and (b) the polymeric fiber optic cable melts via Joule heating before an arc-fault is established through corrosion. Three arc-faults were created in different configurations found in PV systems with the integrated fiber optic system to determine the feasibility of the technology. In each case, the fiber optic cable was broken and the system annunciated the fault.

Johnson, Jay Dean↗

PV Systems Reliability Final Technical Report: Ground Fault Detection

We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Tolerance Assistant (FTA): An Exception Handling Programming Model for MPI Applications

Future high-performance computing systems may face frequent failures with their rapid increase in scale and complexity. Resilience to faults has become a major challenge for large-scale applications running on supercomputers, which demands fault tolerance support for prevalent MPI applications. Among failure scenarios, process failures are one of the most severe issues as they usually lead to termination of applications. However, the widely used MPI implementations do not provide mechanisms for fault tolerance. We propose FTA-MPI (Fault Tolerance Assistant MPI), a programming model that provides support for failure detection, failure notification and recovery. Specifically, FTA-MPI exploits a try/catch model that enables failure localization and transparent recovery of process failures in MPI applications. We demonstrate FTA-MPI with synthetic applications and a molecular dynamics code CoMD, and show that FTA-MPI provides high programmability for users and enables convenient and flexible recovery of process failures.

97 MATHEMATICS AND COMPUTING↗

Model-Based Sensor Placement for Component Condition Monitoring and Fault Diagnosis in Fossil Energy Systems

Design and operation of energy producing, near “zero-emission” coal plants has become a national imperative. This report on model-based sensor placement describes a transformative two-tier approach to identify the optimum placement, number, and type of sensors for condition monitoring and fault diagnosis in fossil energy system operations. The algorithms are tested on a high fidelity model of the integrated gasification combined cycle (IGCC) plant. For a condition monitoring network, whether equipment should be considered at a unit level or a systems level depends upon the criticality of the process equipment, its likeliness to fail, and the level of resolution desired for any specific failure. Because of the presence of a high fidelity model at the unit level, a sensor network can be designed to monitor the spatial profile of the states and estimate fault severity levels. In an IGCC plant, besides the gasifier, the sour water gas shift (WGS) reactor plays an important role. In view of this, condition monitoring of the sour WGS reactor is considered at the unit level, while a detailed plant-wide model of gasification island, including sour WGS reactor and the Selexol process, is considered for fault diagnosis at the system-level. Finally, the developed algorithms unify the two levels and identifies an optimal sensor network that maximizes the effectiveness of the overall system-level fault diagnosis and component-level condition monitoring. This work could have a major impact on the design and operation of future fossil energy plants, particularly at the grassroots level where the sensor network is yet to be identified. In addition, the same algorithms developed in this report can be further enhanced to be used in retrofits, where the objectives could be upgrade (addition of more sensors) and relocation of existing sensors.

20 FOSSIL-FUELED POWER PLANTS↗

Fault Resilient Domain Decomposition Preconditioner for PDEs

The move towards extreme-scale computing platforms challenges scientific simulations in many ways. Given the recent tendencies in computer architecture development, one needs to reformulate legacy codes in order to cope with large amounts of communication, system faults and requirements of low-memory usage per core. In this work, we develop a novel framework for solving partial differential equations (PDEs) via domain decomposition that reformulates the solution as a state-of-knowledge with a probabilistic interpretation. Such reformulation allows resiliency with respect to potential faults without having to apply fault detection, avoids unnecessary communication and is generally well-positioned for rigorous uncertainty quantification studies that target improvements of predictive fidelity of scientific models. We demonstrate our algorithm for one-dimensional PDE examples where artificial faults have been implemented as bit-flips in the binary representation of subdomain solutions.

97 MATHEMATICS AND COMPUTING↗

Electrical Arc Fault Particle Size Characterization

In this investigation a series of small-scale tests were conducted, which were sponsored by the Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) and performed at Sandia National Laboratories (SNL). These tests were designed to better understand localized particle dispersion phenomena resulting from electrical arcing faults. The purpose of these tests was to better characterize aluminum particle size distribution, rates of production, and morphology (agglomeration) of electrical arc faults. More specifically, this effort characterized ejected particles and high-energy dispersion, where this work characterized HEAF electrical characteristics, particle movement/distributions, and morphology near the arc. The results and measurements techniques from this investigation will be used to inform an energy balance model to predict additional energy from aluminum involvement in the arc fault. The experimental setup was developed based on prior work by KEMA and SNL for phase-to-ground and phase-to-phase electrical circuit faults. The small-scale tests results should not be expected to be scale-able to the hazards associated with full-scale HEAF events. Here, the test voltages will consist of four different levels: 480V, 4160V, 6900V and 10kV, based on those realized in nuclear power plant (NPP) HEAF events.

36 MATERIALS SCIENCE↗

A software package for modeling and simulating fault graphs

This report describes a novel fault graph modeling language and a simulation tool for executing models specified in the language. The modeling language has three primary features that distinguish it from similar reliability analysis tools. These are (1) a random variable modeling several distinct outcomes of a single fault; (2) chains of faults in which one fault triggers another; and (3) time to fail sampled from probability distributions including positive normal, exponential, Weibull with a minimum, or immediate. These features are motivated by their use in a historical analysis of centrifuge reliability.

97 MATHEMATICS AND COMPUTING↗

Beam Spill in Downstream Transport due to Injector Faults [PowerPoint]

We have investigated injector faults with numerical experiments. For this investigation we used the nominal tune that is also being used to assess beam stability. Beam spill in the DST due to a serious injector fault was evaluated using the LSP slice algorithm. Only the most serious fault investigated (-350 keV) caused beam spill in the DST. DST transport focusing solenoids limit the beam spill. Beam spill in the DST is the result of large halo caused by betatron oscillations of the mismatched beam. Bremsstrahlung radiation from the DST beam spill was estimated from Tom Martin scaling normalized to DARHT-I. In conclusion, Scorpius is reasonably safe from beam spill radiation in the DST due to injector faults.

43 PARTICLE ACCELERATORS↗

New Geomechanical Computation Analysis Evaluating Behavior of the Fault nearby BC-4

BC-4 is an abandoned brining cavern situated in the middle of the site. Its presence poses a concern for several reasons: 1) the cavern was leached up into the caprock; 2) it is similar to BC-7, a brining cavern on the northwest corner of the dome that collapsed in 1954 and now is the home to Cavern Lake; 3) a similar collapse of BC-4 would have catastrophic consequences for the future operation of the site. There exists a previously mapped fault feature in the caprock and thought to extend into the salt dome than runs in close proximity to BC-4. There are uncertainties about the true extent of the fault, and no explicit analysis has been performed to predict the effects of the fault on BC-4 stability. Additional knowledge of the fault and its effects is becoming more crucial as an enhanced monitoring program is developed and installed.

54 ENVIRONMENTAL SCIENCES↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗