Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure cause”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Failure Analysis and Recovery of a 50mm Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

The ISS Distillation Assembly centrifuge is the pathfinder application for 50mm bore, deep-groove ball bearings made from the highly elastic intermetallic material 60NiTi. Superior corrosion and shock resistance are required to withstand the acidic wastewater exposure and heavy spacecraft launch related loads that challenge conventional steel bearings. During early ground testing one bearing unexpectedly and catastrophically failed after operating for only 200 hours of run time. A second bearing running on the same shaft was completely unaffected. A thorough investigation into the root cause of the failure determined that an excessively tight press-fit of the bearing outer race coupled with NiTis relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully duplicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

intermetallics↗

Thermal barrier coating life modeling in aircraft gas turbine engines

Analytical models useful for predicting ceramic thermal barrier coating (TBC) spalling life in aircraft gas turbine engines are presented. Electron beam-physical vapor deposited (EB-PVD) and plasma sprayed TBC systems are discussed. TBC spalling was attributed to a combination of mechanisms such as metal oxidation at the ceramic-metal interface, ceramic-metal interface stress concentrations at free surfaces due to dissimilar materials, ceramic-metal interface stresses caused by local radius of curvature and interface roughness, material properties and mechanical behavior, transient temperature gradients across the ceramic layer and component design features. TBC spalling life analytical models were developed based on observations of TBC failure modes and plausible failure theories. TBC failure was assumed to occur when the imposed stresses exceeded the material strength (at or near the ceramic-metal interface). TBC failure knowledge gaps caused by lack of experimental evidence and analytical understanding are noted. The analytical models are considered initial engineering approaches that capture observed TBC failure trends.

Nissley, D. M.↗

Thermal barrier coating life modeling in aircraft gas turbine engines

Analytical models for predicting ceramic thermal barrier coating (TBC) spalling life in aircraft gas turbine engines are presented. Electron beam-physical vapor deposited (EB-PVD) and plasma sprayed TBC systems are discussed. An overview of the following TBC spalling mechanisms is presented: metal oxidation at the ceramic-metal interface, ceramic-metal interface stress singularities at edges and corners, ceramic-metal interface stresses caused by radius of curvature and interface roughness, material properties and mechanical behavior, temperature gradients, component design features and object impact damage. TBC spalling life analytical models are proposed based on observations of TBC spalling and plausible failure theories. TBC spalling was assumed to occur when the imposed stresses exceed the material strength (at or near the ceramic-metal interface). TBC failure knowledge gaps caused by lack of experimental evidence and analytical understanding are noted. The analytical models are considered initial engineering approaches that capture observed TBC failure trends.

Nissley, David M.↗

The Voyager 2 scan platform anomaly

The two Voyager spacecraft were launched in the summer of 1977, flew past Jupiter in 1979, and reached Saturn in 1980 and 1981. The Voyager Attitude and Articulation Control Subsystem (AACS) controls the positioning of a scan platform on which scientific instruments are mounted. On August 26, 1981, it was discovered that the azimuth axis of the scan platform of Voyager 2 had not completed the commanded slew. The profile of the failed slew command resembled a similar scan failure on Voyager 1 on February 23, 1979. In that case, contamination of the output gear mesh in the azimuth actuator was identified as the most probable cause of the failure. The problem was solved by cycling the azimuth actuator until the contaminant broke down and smooth operation was restored. A similar treatment applied to the Voyager 2 problem failed. Details of the Voyager 2 anomaly investigation are discussed.

Marchetto, C. A.↗

A Thermal Runaway Failure Model for Low-Voltage BME Ceramic Capacitors with Defects

Reliability of base metal electrode (BME) multilayer ceramic capacitors (MLCCs) that until recently were used mostly in commercial applications, have been improved substantially by using new materials and processes. Currently, the inception of intrinsic wear-out failures in high quality capacitors became much greater than the mission duration in most high-reliability applications. However, in capacitors with defects degradation processes might accelerate substantially and cause infant mortality failures. In this work, a physical model that relates the presence of defects to reduction of breakdown voltages and decreasing times to failure has been suggested. The effect of the defect size has been analyzed using a thermal runaway model of failures. Adequacy of highly accelerated life testing (HALT) to predict reliability at normal operating conditions and limitations of voltage acceleration are considered. The applicability of the model to BME capacitors with cracks is discussed and validated experimentally.

reliability↗

Failure Analysis and Recovery of a 50-mm Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

Ball bearings used inside the ISS Distillation Assembly centrifuge require superior corrosion and shock resistance to withstand acidic wastewater exposure and heavy spacecraft launch related loads. These requirements challenge conventional steel bearings and provide an ideal pathfinder application for 50-mm bore, deep-groove ball bearings made from the corrosion immune and highly elastic intermetallic material 60NiTi. During early ground testing in 2014 one 60NiTi bearing unexpectedly and catastrophically failed after operating for only 200 hr. A second bearing running on the same shaft was completely unaffected. An investigation into the root cause of the failure determined that an excessively tight press fit of the bearing outer race coupled with NiTi's relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully replicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

DellaCorte, Christopher↗

High-Pressure Hot-Gas Self-Acting Floating Ring Shaft Seal for Liquid Rocket Turbopumps

Design analysis, detail design, fabrication, and experimental evaluation was performed on two self acting floating ring shaft seals for a rocket engine turbopump high pressure 24132500 n/sq m (3500 psig) hot gas 533 K 9500 F) high speed 3142 rad/sec (30000 rmp) turbine. The initial design used Rayleigh step hydrodynamic lift pads to assist in centering the seal ring with minimum rubbing contact. The final design used a convergent tapered bore to provide hydrostatic centering force. The Rayleigh step design was tested for 107 starts and 4.52 hours total. The leakage was satisfactory; however, the design was not acceptable due to excessive wear caused by inadequate centering force and failure of the sealing dam caused by erosion damage. The tapered bore design was tested for 370 starts and 15.93 hours total. Satisfactory performance for the required life of 7.5 hours per seal was successfully demonstrated.

Burcham, R. E.↗

Metallographic Preparation of Space Shuttle Reaction Control System Thruster Electron Beam Welds for Electron Backscatter Diffraction

A Space Shuttle Reaction Control System (RCS) thruster failed during a firing test at the NASA White Sands Test Facility (WSTF), Las Cruces, New Mexico. The firing test was being conducted to investigate a previous electrical malfunction. A number of cracks were found associated with the fuel closure plate/injector assembly (Fig 1). The firing test failure generated a flight constraint to the launch of STS-133. A team comprised of several NASA centers and other research institutes was assembled to investigate and determine the root cause of the failure. The JSC Materials Evaluation Laboratory was asked to compare and characterize the outboard circumferential electron beam (EB) weld between the fuel closure plate (Titanium 6Al-4V) and the injector (Niobium C-103 alloy) of four different RCS thrusters, including the failed RCS thruster. Several metallographic challenges in grinding/polishing, and particularly in etching were encountered because of the differences in hardness, ductility, and chemical resistance between the two alloys and the bimetallic weld. Segments from each thruster were sectioned from the outboard weld. The segments were hot-compression mounted using a conductive, carbon-filled epoxy. A grinding/polishing procedure for titanium alloys was used [1]. This procedure worked well on the titanium; but a thin, disturbed layer was visible on the niobium surface by means of polarized light. Once polished, each sample was micrographed using bright field, differential interference contrast optical microscopy, and scanning electron microscopy (SEM) using a backscatter electron (BSE) detector. No typical weld anomalies were observed in any of the cross sections. However, areas of large atomic contrast were clearly visible in the weld nugget, particularly along fusion line interfaces between the titanium and the niobium. This prompted the need to better understand the chemistry and microstructure of the weld (Fig 2). Energy Dispersive X-Ray Spectroscopy (EDS) was used to confirm the chemical composition of the variations in contrast in these areas. Niobium alloys generally require exposure to more aggressive chemical reagents than titanium alloys for etching because of niobium s chemical resistance; therefore, the titanium portion of the sample was etched first. A five second immersion in Kroll s reagent revealed a general microstructure on the titanium portion of the sample; however, the titanium heat affected zone closest to the weld, was over-etched due to higher concentrations of refined grains and an increase in eta-phase. The Kroll s etchant also revealed some microstructure in the weld nugget itself; the niobium portion of the sample remained unetched.

Martinez, James↗

Space Shuttle Stiffener Ring Foam Failure, a Non-Conventional Approach

The Space Shuttle makes use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications debond, classical methods of analysis do not always provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis. Thin sectioning in two directions, both horizontal and vertical to the application, was chosen to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.

Howard, Philip M.↗

Evaluation of Data Retention Characteristics for Ferroelectric Random Access Memories (FRAMs)

Data retention and fatigue characteristics of 64 Kb lead zirconate titanate (PZT)-based Ferroelectric Random Access Memories (FRAMs) microcircuits manufactured by Ramtron were examined over temperature range from -85 C to +310 C for ceramic packaged parts and from -85 C to +175 C for plastic parts, during retention periods up to several thousand hours. Intrinsic failures, which were caused by a thermal degradation of the ferroelectric cells, occurred in ceramic parts after tens or hundreds hours of aging at temperatures above 200 C. The activation energy of the retention test failures was 1.05 eV and the extrapolated mean-time-to-failure (MTTF) at room temperature was estimated to be more than 280 years. Multiple write-read cycling (up to 3x10(exp 7)) during the fatigue testing of plastic and ceramic parts did not result in any parametric or functional failures. However, operational currents linearly decreased with the logarithm of number of cycles thus indicating fatigue process in PZT films. Plastic parts, that had more recent date code as compared to ceramic parts, appeared to be using die with improved process technology and showed significantly smaller changes in operational currents and data access times.

Sharma, Ashok K.↗

Degradation of ILW Drums Due to Internal Metallic Corrosion - 18036

Within the British nuclear inventory, metallic Intermediate Level Waste (ILW) is encapsulated in grout and stored in stainless steel drums. Based on recent inspections held in the relevant storage facilities (Sellafield, Cumbria), a proportion of these drums have exhibited considerable distortion, raising concerns about the long-term safety of the packages. Distortion may be caused by the generation of voluminous and potentially flammable substances resulting from metallic corrosion occurring within the drums' core. Potential oxygen influx in the event of steel fracture and consequently drum's failure could potentially cause release or even ignition of the encapsulated radioactive material. The mechanical degradation of the encapsulants (stainless steel and grout) induced from the progressive corrosion of the encapsulated metallic components (and the associated volume expansion) was investigated using both Finite Element Modelling (FEM) techniques as well as experimental trials. A parametric study using simplified 3D FE models was performed to determine their structural integrity under different scenarios. Synchrotron X-Ray tomography (XRT) was used to monitor the behaviour of miniaturized ILW drum-simulants, whilst the latter were subjected to controlled accelerated corrosion in situ. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualizing Lithium Dendrite Formation within Solid-State Electrolytes

Solid-state electrolyte (SSE) is promising for application in allsolid-state lithium metal batteries because of its reliable safety and longevity. The failure of SSE to suppress dendrite formation of Li metal anodes has been conventionally explained by uneven Li deposition at Li/SSE interfaces and its subsequent dendritic growth. While Li deposition within SSE has been recently proposed as another key cause for SSE failure, little is known regarding the Li growth details inside the SSE itself. In this work, we performed in situ microscopic observation of Li deposition inside the SSE and obtained visualized evidence regarding the dynamic process of Li dendrite formation and growth. Here, Li is seen to directly nucleate and propagate within the SSE, leading to its structural cracking. Such behavior should be caused by the presence of P- and S-based crystalline defects in Li 3 PS 4 SSE, which is consistent with the cryo-transmission electron microscopy observations and theoretical calculations. This observation provides important insights into the growth mechanisms of Li dendrites within a working lithium battery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accommodating Actuator Failures in Flight Control Systems

A technique for the design of flight control systems that can accommodate a set of actuator failures is presented. As employed herein, an actuator failure is defined as any change in the parametric model of the actuator which can adversely affect actuator performance. The technique is based upon the formulation of a fixed feedback topology which ensures at least stability in the presence of the failures in the set. The fixed compensation is obtained from a loop-shaping design procedure similar to Quantitative Feedback Theory and provides stability robustness in the presence of uncertainty in the vehicle dynamics caused by the failures. System adaptation to improve performance after actuator failure(s) occurs through a static gain adjustment in the compensator followed by modification of the system prefilter. Precise identification of the vehicle dynamics is unnecessary. Application to a single-input, single-output design using a simplified model of the longitudinal dynamics of the NASA High Angle of Attack Research Vehicle is discussed. Non-real time simulations of the system including a model of the pilot demonstrate the effectiveness and limitations of the approach.

Hess, R. A.↗

Extravehicular Mobility Unit (EMU) / International Space Station (ISS) Coolant Loop Failure and Recovery

Following the Colombia accident, the Extravehicular Mobility Units (EMU) onboard ISS were unused for several months. Upon startup, the units experienced a failure in the coolant system. This failure resulted in the loss of Extravehicular Activity (EVA) capability from the US segment of ISS. With limited on-orbit evidence, a team of chemists, engineers, metallurgists, and microbiologists were able to identify the cause of the failure and develop recovery hardware and procedures. As a result of this work, the ISS crew regained the capability to perform EVAs from the US segment of the ISS.

Lewis, John F.↗

Systematic Destruction of Electronic Parts for Aid in Electronic Failure Analysis

NASA analyzes electrical, electronic, and electromechanical (EEE) parts used in space vehicles to understand failure modes of these components. Operational amplifiers and transistors are two examples of EEE parts critical to NASA missions that can fail due to electrical overstress (EOS). EOS is the result of voltage or current over time conditions that exceeds a component s specification limit. The objective of this study was to provide known voltage pulses over well-defined time intervals to determine the type and extent of damage imparted to the device. The amount of current was not controlled but measured so that pulse energy was determined. The damage was ascertained electrically using curve trace plots and optically using various metallographic techniques. The resulting data can be used to build a database of physical evidence to compare to damaged components removed from flight avionics. The comparison will provide the avionics failure analyst necessary information about voltage and times that caused flight or test failures when no other electrical data is available.

Decker, S. E.↗

OH-58 helicopter transmission failure analysis

The OH-58 main transmission gearbox was run at varying output torques, speeds, and oil cooling rates. The gearbox was subsequently run to destruction by draining the oil from the gearbox while operating at a speed of 6200 revs per minute and 36,000 inch-pounds output torque. Primary cause of gearbox failure was overheating and melting of the planet bearing aluminum cages. Complete failure of the gearbox occurred in 28 1/2 minutes after the oil pressure dropped to zero. The alternating and maximum stresses in the gearbox top case were approximately 10 percent of the endurance limit for the material. Deflection of the bevel gear at 67000 inch-pounds output torque indicate a marginal stiffness for the bevel gear supporting system.

Townsend, D. P.↗

X-33 Tank Failure During Autoclave Fabrication

During a repair cure cycle on tank #1 of the X-33 liquid hydrogen tanks, a skin to core disbond occurred. Both the inner skin and outer skin of the lobe #1 sandwich panel was noted to have been disbonded and cracked- An investigation was undertaken to determine the cause of this failure. The investigation consisted of reviewing all of the processing data and performing testing on the failed lobe #1, as well as the other lobes, which did not fail during the cure cycle. The tests consisted of residual stress measurements in one of the intact lobes and "plug-pulls" to assess skin to core strength on all of the remaining lobes. Results showed an extremely low bondline strength due to lack of proper filleting of the adhesive, in addition, tests showed a very rapid decrease in strength with increasing temperature, as well as a further decrease in strength with a larger number of cycles. Also, the honeycomb used was not vented so pressure could build up within the cells. All of these factors appeared to be contributors to the failure.

Nettles, Alan T.↗