Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Stellar diameters and temperatures. IV. Predicting stellar angular diameters

The number of stellar angular diameter measurements has greatly increased over the past few years due to innovations and developments in the field of long baseline optical interferometry. We use a collection of high-precision angular diameter measurements for nearby, main-sequence stars to develop empirical relations that allow the prediction of stellar angular sizes as a function of observed photometric color. These relations are presented for a combination of 48 broadband color indices. We empirically show for the first time a dependence on metallicity of these relations using Johnson (B – V) and Sloan (g – r) colors. Our relations are capable of predicting diameters with a random error of less than 5% and represent the most robust and empirical determinations of stellar angular sizes to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Chandra and very large array observations of the nearby Sd galaxy NGC 45

We present an analysis of high angular resolution observations made in the X-ray and the radio with the Chandra X-ray Observatory and the Karl Jansky Very Large Array (VLA), respectively, of the nearby spiral galaxy NGC 45. This galaxy is the third that we have considered in a study of the supernova remnant (SNR) populations of nearby spiral galaxies and the present work represents the first detailed analysis of the discrete X-ray and radio source populations of this galaxy. We analyzed data sets from the three pointed observations made of this galaxy with Chandra along with a merged data set obtained from combining these data sets: the total effective exposure time of the merged data set is 63515 s. A total of 25 discrete X-ray sources are found in the entire field of view of the ACIS-S3 chip, with 16 sources found within the visual extent of the galaxy. We estimate that as many as half of the sources detected in the entire field of view of the ACIS-S3 chip and seven of the sources detected in the optical extent of NGC 45 may be background sources. We analyzed the spectral properties of the discrete X-ray sources within the galaxy and conclude that the majority of these sources are X-ray binaries. We have searched for counterparts at different wavelengths to the discrete X-ray sources and we find two associations: one with a star cluster and the other with a background galaxy. We have found one source that is clearly variable within one observation and seven that are seen to vary from one observation to another. We also conduct a photometric analysis to determine the near-infrared fluxes of the discrete X-ray sources in Spitzer Infrared Array Camera channels. We constructed a cumulative luminosity function of the discrete X-ray sources seen toward NGC 45: taking into account simultaneously the luminosity function of background sources, the fitted slope of the cumulative luminosity function Γ = –1.3{sub −1.6}{sup +0.7} (all error bounds correspond to 90% confidence intervals). The VLA observations reveal seven discrete radio sources: we find no overlaps between these sources and the X-ray detected sources. Based on their measured spectral indices and their locations with respect to the visible extent of NGC 45, we classify one source as a candidate radio SNR associated with the galaxy and the others as likely background galaxies seen in projection toward NGC 45. Finally, we discuss the properties of a background cluster of galaxies (denoted as CXOU J001354.2–231254.7) seen in projection toward NGC 45 and detected by the Chandra observations. The fit parameters to the extracted Chandra spectra of this cluster are a column density N{sub H} = 0.07(<0.14) × 10{sup 22} cm{sup −2}, a temperature kT = 4.22{sub −1.42}{sup +2.08} keV, an abundance Z = 0.30(<0.75) relative to solar and a redshift z = 0.28 ± 0.14. From the fit parameters we derive an electron number density n{sub e} = 4(±1) × 10{sup −3} cm{sup −3}, an unabsorbed X-ray luminosity L{sub 0.5−7.0 keV} ∼ 8.77(±0.96) × 10{sup 43} erg s{sup −1} for the cluster and an X-ray emitting mass M = 2.32(±1.75) × 10{sup 12} M{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

“Shoulda, Coulda, Woulda”: Conceptualizing the Differences in Trust Between Human-Human Teaming and Human-Machine Teaming

Intelligent decision support systems (IDSSs) are machine teammates designed to facilitate better human decision-making in high-consequence domains such as health care, power grid operations, and fraud detection. IDSSs identify patterns in datasets and provide intelligent decision-making recommendations to human teammates. However, previous research indicates that humans often trust IDSS recommendations less than the recommendations from their human teammates, even when the machine teammate is more accurate. To conceptualize why trust differs, we review the literature surrounding trust, error, and predictability. Then, we compile and compare participant trust ratings and decision-making in an abridged systematic review of previous studies manipulating teammate type, error rate, and error type. Finally, we conduct a content analysis of participants’ qualitative responses to trust queries from a survey on generative language models. Results suggest that humans may trust IDSS teammates less than other human teammates because of differences in (1) interaction complexity, (2) blame attribution, and (3) swift trust. We conclude that human factors practitioners should collaborate with data scientists and domain experts to build and maintain trust in IDSSs by anthropomorphizing algorithms, matching mental models, and considering individual differences.

97 MATHEMATICS AND COMPUTING↗

Computationally efficient subglacial drainage modelling using Gaussian process emulators: GlaDS-GP v1.0

Subglacial drainage models represent water flow at the ice–bed interface through coupled distributed and channelized systems to determine water pressure, discharge, and drainage system geometry. While they are used to understand processes such as the relationship between surface melt and ice flow, the number of uncertain model parameters and the computational cost of running models makes it difficult to adequately explore the high-dimensional parameter space and evaluate uncertainty in model predictions. Here, we develop Gaussian process (GP) emulators that make fast predictions with associated uncertainty of subglacial drainage model outputs. Using a truncated principal component (PC) basis representation, we construct a GP emulator for diurnally averaged subglacial water pressure. We also explore emulation of scalar variables describing drainage efficiency and configuration. We train the emulators using ensembles of up to 512 simulations varying eight parameters of the Glacier Drainage System (GlaDS) model on a synthetic domain intended to represent an ice-sheet margin. The emulators make predictions ∼ 1000 times faster than GlaDS simulations, with errors <3 % for the water pressure field and ∼ 5 %–9 % for drainage efficiency and configuration. We apply the emulators to explore the eight-dimensional parameter space by computing variance-based parameter sensitivity indices, finding that three parameters (ice flow coefficient, bed bump aspect ratio, and the subglacial cavity system conductivity) explain 90 % of the variance in modelled water pressure in response to parameter changes. The GP emulator approach described here is well suited to integrating observational data with models to make calibrated, credible predictions of subglacial drainage.

58 GEOSCIENCES↗

Mechanical properties of several Fe-Ni meteorites

The strength and elastic constants of meteorites are of increasing interest as predictions of meteorite impacts on earth come within the realm of possibility. In addition, meteorite impacts on extraterrestrial bodies provide an excellent sampling tool for evaluation of planetary compositions and properties. Fe-Ni meteorites provide a well-defined group of materials of fairly uniform composition. Iron-nickel meteorites exhibit a unique lamellar microstructure, a Widmanstatten structure, consisting of small regions with steep-iron-nickel composition gradients. This microstructure is found in the Fe-Ni system only in meteorites, and is believed to arise as a result of slow cooling in a planetary core or other large mass. Meteorites with compositions consisting of between 5 and 17% nickel in iron are termed 'octahedrite,' and further characterized according to the width of the Ni-poor kamacite bands; 'fine,' (0.2-0.5 mm) 'medium,' (0.5-1.3 mm) and 'coarse,' (1.5-3.3 mm). Many meteorites have inclusions and structures indicating that the material has been shocked at some point early in its evolution. Several Iron-nickel meteorites have been examined using Vickers and spherical indentation, x-ray fluorescence, and EBSD. Direct observation of mechanical properties in these highly structured materials provides a valuable supplement to bulk measurements, which frequently exhibit large variation in dynamic properties, even within a single sample. Previous studies of the mechanical properties of a typical iron-nickel meteorite, a Diablo Canyon specimen, indicated that the strength of the composite was higher by almost an order of magnitude than values obtained from laboratory-prepared specimens. Additional meteorite specimens have been examined to establish a range of error on the previously measured yield, to determine the extent to which deformation upon re-entry contributes to yield, and to establish the degree to which the strength varies as a function of microstructure.

36 MATERIALS SCIENCE↗

Higher-order space-charge stability in anisotropic beams: Vlasov-Poisson derivation, refined dispersion relations, and stability charts

The Hofmann stability chart is used to screen working points in space-charge-dominated linacs. We identify two errors in its published higher-order dispersion relations: missing $(1\mp2\hatη^2/α)$ factors in the third-order $S^4$ coupling residues, and a sign error in the stated isotropic reduction of the fourth-order relation. Both corrections follow from Hofmann's Vlasov-Poisson equations without fitted parameters. They reproduce coherent tune-shift coefficients in the author's later monograph that the printed forms miss by 24% and 127%. Mode-resolved figures from a published application agree with the corrected relations and reject the printed forms, indicating an inconsistency between the 1998 equations and the calculations underlying those tested figures. We quantify the effect on the non-oscillatory stability chart. Inside the adopted $S^2\le10$ comparison domain, printed and corrected forms disagree on 0.73-2.11% of cells, with no preferred direction. Among excluded cells, disagreement reaches 22%, and the printed relation over-predicts instability at every sampled anisotropy. This concentration may help explain why the errors persisted, although it does not establish their historical cause. For PIP-II, the corrected chart flags four of thirty-two evaluable periods, including one on a third-order odd branch missed by a second-order screen. This count covers non-oscillatory modes only and remains conditional on an unresolved factor-five disagreement between two codes on transverse emittance growth.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208↗

SU-E-J-267: Weekly Volumetric and Dosimetric Changes in Adaptive Conformal Radiotherapy of Non-Small-Cell-Lung Cancer Using 4D CT and Gating

Purpose: This study was to evaluate the significance of weekly imageguided patient setup and to assess the volumetric and dosimetric changes in no-small-cell-lung cancer (NSCLC) patients treated with adaptive conformal radiotherapy (CRT). Methods: 9 NSCLC patients treated with 3D CRT underwent 4D CT-on-rail every five fractions. ITV was generated from three phases of the 4DCT (the end of exhalation, 25% before and after the end of exhalation). The margin of ITV to PTV is 5mm. 6 weekly CTs were acquired for each patient. The weekly CTs were fused with the planning CT by vertebrae. The couch shift was recorded for each weekly CT to evaluate the setup error. The gross tumor volumes (GTVs) were contoured on weekly CT images by a physician. Beams from the original plans were applied to weekly CTs to calculate the delivered doses. All patients underwent replanning after 20 fractions. Results: Among the total 54 CTs, the average setup error was 2.0± 1.7, 2.6± 2.1, 2.7± 2.2 mm in X, Y, and Z direction, respectively. The average volume of the primary GTV was reduced from 42.45 cc to 22.78 cc (47.04%) after 6 weeks. The maximal volume regression occurred between 15 and 20 fractions. Adaptive radiation therapy (ART) reduced the V20 and V5 of the lung by 33.5% and 16.89%, respectively. ART also reduced Dmean and D1/3 of the heart by 31.7% and 32.32%, respectively. Dmax of the spinal cord did not vary much during the treatment course. Conclusion: 5 mm margin is sufficient for 4D weekly CTguided radiotherapy in lung cancer. Tumor regression was observed in the majority of patients. ART significantly reduced the OARs dose. Our preliminary results indicated that an off-line ART approach is appropriate in clinical practice.

60 APPLIED LIFE SCIENCES↗

Analysis of over-magnetization of elemental transition metal solids from the SCAN density functional

Current investigations have revealed that the strongly constrained and appropriately normed (SCAN) meta-generalized gradient approximation exchange-correlation functional significantly over-magnetizes elemental Fe, Co, and Ni solids. For the paradigmatic case, bcc Fe, the error relative to experiment is ≳ 20 % . A comparative analysis of magnetization results from SCAN and its deorbitalized counterpart, SCAN-L, leads to identification of the source of the discrepancy. It is not from the difference between Kohn-Sham (SCAN-L) and generalized Kohn-Sham (SCAN) procedures. The key is the iso-orbital indicator α (the ratio of the local Pauli and Thomas-Fermi kinetic energy densities). Its deorbitalized counterpart α L has more dispersion in both spin channels with respect to magnetization in an approximate region between 0.6 and 1.2 bohrs around an Fe nucleus. The overall effect is that the SCAN switching function evaluated with α L reduces the energetic disadvantage of the down channel with respect to up compared to the original α , which in turn reduces the magnetization. This identifies the origin of the SCAN magnetization error as insensitivity of the SCAN switching function to α values in the approximate range 0.5 ≲ α ≲ 0.8 and oversensitivity for α ≳ 0.8 .

36 MATERIALS SCIENCE↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Robust verification of stochastic simulation codes

We introduce a robust verification tool for computational codes, which we call Stochastic Robust Extrapolation based Error Quantification (StREEQ). Unlike the prevalent Grid Convergence Index (GCI) [1] method, our approach is suitable for both stochastic and deterministic computational codes and is generalizable to any number of discretization variables. Building on ideas introduced in the Robust Verification [2] approach, we estimate the converged solution and orders of convergence with uncertainty using multiple fits of a discretization error model. In contrast to Robust Verification, we perform these fits to many bootstrap samples yielding a larger set of predictions with smoother statistics. Here, bootstrap resampling is performed on the lack-of-fit errors for deterministic code responses, and directly on the noisy data set for stochastic responses. This approach lends a degree of robustness to the overall results, capable of yielding precise verification results for sufficiently resolved data sets, and appropriately expanding the uncertainty when the data set does not support a precise result. For stochastic responses, a credibility assessment is also performed to give the analyst an indication of the trustworthiness of the results. Furthermore, this approach is suitable for both code and solution verification, and is particularly useful for solution verification of high-consequence simulations..

97 MATHEMATICS AND COMPUTING↗

A hybrid adaptive multiresolution approach for the efficient simulation of reactive flows

Computational studies that use block-structured adaptive mesh refinement (AMR) approaches suffer from unnecessarily high mesh resolution in regions adjacent to important solution features. This deficiency limits the performance of AMR codes. In this work a novel hybrid adaptive multiresolution (HAMR) approach to AMR-based calculations is introduced to address this issue. The multiresolution (MR) smoothness indicators are used to identify regions of smoothness on the mesh where the computational cost of individual physics solvers may be decreased by replacing direct calculations with interpolation. We suggest an approach to balance the errors due to the adaptive discretization and the interpolation of physics quantities such that the overall accuracy of the HAMR solution is consistent with that of the MR-driven AMR solution. The performance of the HAMR scheme is evaluated for a range of test problems, from pure hydrodynamics to turbulent combustion.

97 MATHEMATICS AND COMPUTING↗

Enhanced CO 2 Reactive Capture and Conversion Using Aminothiolate Ligand–Metal Interface

Metallic catalyst modification by organic ligands is an emerging catalyst design in enhancing the activity and selectivity of electrocatalytic carbon dioxide (CO 2 ) reactive capture and reduction to value-added fuels. However, a lack of fundamental science on how these ligand–metal interfaces interact with CO 2 and key intermediates under working conditions has resulted in a trial-and-error approach for experimental designs. With the aid of density functional theory calculations, we provided a comprehensive mechanism study of CO 2 reduction to multicarbon products over aminothiolate-coated copper (Cu) catalysts. Our results indicate that the CO 2 reduction performance was closely related to the alkyl chain length, ligand coverage, ligand configuration, and Cu facet. The aminothiolate ligand–Cu interface significantly promoted initial CO 2 activation and lowered the activation barrier of carbon–carbon coupling through the organic (nitrogen (N)) and inorganic (Cu) interfacial active sites. Experimentally, the selectivity and partial current density of the multicarbon products over aminothiolate-coated Cu increased by 1.5-fold and 2-fold, respectively, as compared to the pristine Cu at –1.16 V RHE , consistent with our theoretical findings. Furthermore, this work highlights the promising strategy of designing the ligand–metal interface for CO 2 reactive capture and conversion to multicarbon products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalar and tensor perturbations in loop quantum cosmology: high-order corrections

Loop quantum cosmology (LQC) provides promising resolutions to the trans-Planckian issue and initial singularity arising in the inflationary models of general relativity. In general, due to different quantization approaches, LQC involves two types of quantum corrections, the holonomy and inverse-volume, to both of the cosmological background evolution and perturbations. In this paper, using the third-order uniform asymptotic approximations, we derive explicitly the observational quantities of the slow-roll inflation in the framework of LQC with these quantum corrections. We calculate the power spectra, spectral indices, and running of the spectral indices for both scalar and tensor perturbations, whereby the tensor-to-scalar ratio is obtained. We expand all the observables at the time when the inflationary mode crosses the Hubble horizon. As the upper error bounds for the uniform asymptotic approximation at the third-order are ∼< 0.15%, these results represent the most accurate results obtained so far in the literature. It is also shown that with the inverse-volume corrections, both scalar and tensor spectra exhibit a deviation from the usual shape at large scales. Then, using the Planck, BAO and SN data we obtain new constraints on quantum gravitational effects from LQC corrections, and find that such effects could be within the detection of the forthcoming experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Current data are consistent with flat spatial hypersurfaces in the Λ CDM cosmological model but favor more lensing than the model predicts

Here, we study the performance of three pairs of tilted, and a pair of untilited, ΛCDM cosmological models, with three of these four pairs allowing for non-flat spatial hypersurfaces, against cosmic microwave background (CMB) temperature and polarization power spectrum data (P18), measurements of the Planck 2018 lensing potential power spectrum (lensing), and a large compilation of non-CMB data (non-CMB). For the eight models, we measure cosmological parameters and study whether or not pairs of the data sets (as well as subsets of them) are mutually consistent in these models. Half of these models allow the lensing consistency parameter A L , which re-scales the gravitational potential power spectrum, to be an additional free parameter to be determined from data, while the other three have A L = 1 which is the theoretically expected value. The pair of untilted non-flat ΛCDM models are incompatible with P18 data. The tilted spatially-flat models assume the usual primordial spatial inhomogeneity power spectrum that is a power law in wave number. The tilted non-flat models assume either the primordial power spectrum used in the Planck group anal yses [Planck P(q)], that has recently been numerically shown to be a good approximation to what is quantum-mechanically generated from a particular choice of closed inflation model initial conditions, or a recently computed power spectrum [new P(q)] that quantum-mechanically follows from a different set of non-flat inflation model initial conditions. In the tilted non-flat models with A L = 1 we find differences between P18 data and non-CMB data cosmological parameter constraints, which are large enough to rule out the Planck P(q) model at 3σ but not the new P(q) model. No significant differences are found when cosmological parameter constraints obtained with two different data sets are compared within the standard tilted flat ΛCDM model. While both P18 data and non-CMB data separately favor a closed geometry, with spatial curvature density parameter Ω k < 0, when P18+non-CMB data are jointly analyzed the evidence in favor of non-flat hypersurfaces subsides. Differences between P18 data and non-CMB data cosmological constraints subside when A L is allowed to vary. From the most restrictive P18+lensing+non-CMB data combination we get almost model-independent constraints on the cosmological parameters and find that the A L > 1 option is preferred over the Ω k < 0 one, with the A L parameter, for all models, being larger than unity by ~ 2.5σ. According to the deviance information criterion, in the P18+lensing+non-CMB analysis, the varying A L option is on the verge of being strongly favored over the A L = 1 one, which could indicate a problem for the standard tilted flat ΛCDM model. These data are consistent with flat spatial hypersurfaces but more and better data could improve the constraints on Ω k and might alter this conclusion. Error bars on some cosmological parameters are significantly reduced when non-CMB data are used jointly with P18+lensing data. For example, in the tilted flat ΛCDM model for P18+lensing+non-CMB data the Hubble constant H 0 = 68.09 ± 0.38 km s -1 Mpc -1 , which is consistent with that from a median statistics analysis of a large compilation of H 0 measurements as well as with a number of local measurements of the cosmological expansion rate. This H 0 error bar is 31% smaller than that from P18+lensing data alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic Sparse View Selection Using the View Covariance Loss

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

Lin, Jingsong [Purdue University]↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-AB-207A-11: Anatomical and Functional Assessment of Coronary Artery Disease Using Low-Dose Whole-Organ Dynamic Computed Tomography

Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosis level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗