Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Comparison of Instantaneous Frequency Scaling from Rain Attenuation and Optical Disdrometer Measurements at K/Q bands

Rain attenuation is strongly dependent on the rain rate, but also on the rain drop size distribution (DSD). Typically, models utilize an average drop size distribution, such as those developed by Laws and Parsons, or Marshall and Palmer. However, individual rain events may possess drop size distributions which could be significantly different from the average and will impact, for example, fade mitigation techniques which utilize channel performance estimates from a signal at a different frequency. Therefore, a good understanding of the characteristics and variability of the raindrop size distribution is extremely important in predicting rain attenuation and instantaneous frequency scaling parameters on an event-toevent basis. Since June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have measured the attenuation due to rain in Milan, Italy, on the 20/40 GHz beacon signal broadcast from the Alphasat TDP#5 Aldo Paraboni Q/V-band Payload. Concomitant with these measurements are the measurements of drop size distribution and rain rate utilizing a Thies Clima laser precipitation monitor (disdrometer). In this paper, we discuss the comparison of the predicted rain attenuation at 20 and 40 GHz derived from the drop size distribution data with the measured rain attenuation. The results are compared on statistical and real-time bases. We will investigate the performance of the rain attenuation model, instantaneous frequency scaling, and the distribution of the scaling factor. Further, seasonal rain characteristics will be analysed.

millimeter wave↗

Statistical Analysis of Instantaneous Frequency Scaling Factor as Derived From Optical Disdrometer Measurements At KQ Bands

The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer [1]). However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link [2]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.

Radio Attenuation↗

Statistical Analysis of Instantaneous Frequency Scaling Factor as Derived From Optical Disdrometer Measurements At KQ Bands

The rain rate data and statistics of a location are often used in conjunction with models to predict rain attenuation. However, the true attenuation is a function not only of rain rate, but also of the drop size distribution (DSD). Generally, models utilize an average drop size distribution (Laws and Parsons or Marshall and Palmer. However, individual rain events may deviate from these models significantly if their DSD is not well approximated by the average. Therefore, characterizing the relationship between the DSD and attenuation is valuable in improving modeled predictions of rain attenuation statistics. The DSD may also be used to derive the instantaneous frequency scaling factor and thus validate frequency scaling models. Since June of 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have jointly conducted a propagation study in Milan, Italy utilizing the 20 and 40 GHz beacon signals of the Alphasat TDP#5 Aldo Paraboni payload. The Ka- and Q-band beacon receivers provide a direct measurement of the signal attenuation while concurrent weather instrumentation provides measurements of the atmospheric conditions at the receiver. Among these instruments is a Thies Clima Laser Precipitation Monitor (optical disdrometer) which yields droplet size distributions (DSD); this DSD information can be used to derive a scaling factor that scales the measured 20 GHz data to expected 40 GHz attenuation. Given the capability to both predict and directly observe 40 GHz attenuation, this site is uniquely situated to assess and characterize such predictions. Previous work using this data has examined the relationship between the measured drop-size distribution and the measured attenuation of the link]. The focus of this paper now turns to a deeper analysis of the scaling factor, including the prediction error as a function of attenuation level, correlation between the scaling factor and the rain rate, and the temporal variability of the drop size distribution both within a given rain event and across different varieties of rain events. Index Terms-drop size distribution, frequency scaling, propagation losses, radiowave propagation.

Statistics↗

Variability of Disk Emission in Pre-main Sequence and Related Stars. V. OccultationEvents from the Innermost Disk Region of the Herbig Ae Star HD 163296

HD 163296 is a Herbig Ae star that underwent a dramatic∼0.8 magnitude drop in brightness in the V photometric band in 2001 and a brightening in the near-IR in 2002. Because the star possesses Herbig–Haro objects traveling in out flowing bipolar jets, it was suggested that the drop in brightness was due to a clump of dust entrained in a disk wind, blocking the line of sight toward the star. In order to quantify this hypothesis, we investigated the brightness drop at visible wavelengths and the brightening at near-IR wavelengths of HD 163296 using the Monte Carlo Radiative Transfer Code,HOCHUNK3D. We created three models to understand the events. Model 1 describes the quiescent state of the system. Model 2 describes the change in structure that led to the drop in brightness in 2001.Model 3 describes the structure needed to produce the observed 2002 brightening of the near-IR wavelengths. Models 2 and 3 utilize a combination of a disk wind and central bipolar flow. By introducing a filled bipolar cavity in Models 2 and 3, we were able to successfully simulate a jet-like structure for the star with a disk wind and created the drop and subsequent increase in brightness of the system. On the other hand, when the bipolar cavity is not filled, Model 1 replicates the quiescent state of the system

Monika Pikhartova↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models.

Icing↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models

Icing , Simulation, Validation↗

Comparison of Bimodal Ice Shapes on Full-Chord and Hybrid CRM Midspan Models

An ice shape database has been created to document ice accretions on a full-chord length and hybrid versions of a 65 percent scale size of the mid-span section of the Common Research Model resulting from an exposure to a Super-cooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each ice accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from monomodal distributions of identical cloud droplet Median Volume Diameter (MVD) were obtained and compared. Results indicated that the ice shapes resulting from the monomodal and bimodal drop size distributions have similar 2D Maximum Combined Cross Section, or MCCS, ice shape around the model leading edge region and equivalent ice mass measurement per unit span to within the IRT SLD cloud calibration uncertainty, as expected with this approach, but the bimodal distributions have distinctly larger ice feathers that extended further back on the chord of the model. For most test conditions, the overall size and shape of the main ice accretions compared well between the full-chord and hybrid models.

Icing↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Experimental Investigation of Entrance-region Heat-transfer Coefficients

Experimental results of tests made at the Langley Memorial Aeronautical Laboratory are presented to show how heat-transfer coefficients can he increased by a method utilizing the high rate of heat transfer known to exist on any heat-transfer surface in the region adjacent to the edge on which the cooling or heating fluid impinges. The results show that, for the same pressure drop, the average surface heat-transfer.coefficient can be increased 50 to 100 percent when a cooling surface having a length of four inches in the direction of fluid flow is cut to form twenty fins with a length of 0.2 inch in the direction of fluid flow and the fins are sharpened and staggered in the air stream. The percentage of increase in the surface heat-transfer coefficient obtained as a result of shortening the length of the cooling surface varies with the pressure drop of the cooling fluid in passing the surface, the increase being largest when small pressure drop is used and smallest when high pressure drop is used.

HEAT EXCHANGERS - PRESSURE DROP↗

D.R.O.P: The Durable Reconnaissance and Observation Platform

Robots can provide a remote presence in areas that are either inaccessible or too dangerous for humans. However, robots are often limited by their ability to adapt to the terrain or resist environmental factors. The Durable Reconnaissance and Observation Platform (DROP) is a lightweight robot that addresses these challenges with the capability to survive falls from significant heights, carry a useable payload, and traverse a variety of surfaces, including climbing vertical surfaces like wood, stone, and concrete. DROP is manufactured using a combination of rapid prototyping and shape deposition manufacturing. It uses microspine technology to create a new wheel-like design for vertical climbing. To date, DROP has successfully engaged several vertical surfaces, hanging statically without assistance, and traversed horizontal surfaces at approximately 30 cm/s. Unassisted vertical climbing is capable on surfaces up to 85deg at a rate of approximately 25cm*s(sup -1). DROP can also survive falls from up to 3 meters and has the ability to be thrown off of and onto rooftops. Future efforts will focus on improving the microspine wheels, selecting more resilient materials, customizing the controls, and performing more rigorous and quantifiable testing.

Durable Reconnaissance and Observation Platform (D↗

NASA Glenn Icing Research Tunnel: 2014 and 2015 Cloud Calibration Procedures and Results

This report summarizes the current status of the NASA Glenn Research Center (GRC) Icing Research Tunnel cloud calibration: specifically, the cloud uniformity, liquid water content, and drop-size calibration results from both the January-February 2014 full cloud calibration and the January 2015 interim cloud calibration. Some aspects of the cloud have remained the same as what was reported for the 2014 full calibration, including the cloud uniformity from the Standard nozzles, the drop-size equations for Standard and Mod1 nozzles, and the liquid water content for large-drop conditions. Overall, the tests performed in January 2015 showed good repeatability to 2014, but there is new information to report as well. There have been minor updates to the Mod1 cloud uniformity on the north side of the test section. Also, successful testing with the OAP-230Y has allowed the IRT to re-expand its operating envelopes for large-drop conditions to a maximum median volumetric diameter of 270 microns. Lastly, improvements to the collection-efficiency correction for the SEA multi-wire have resulted in new calibration equations for Standard- and Mod1-nozzle liquid water content.

aircraft icing↗

Gas-Liquid Flows Through Porous Media in Microgravity: The International Space Station Packed Bed Reactor Experiment

Experimental results on pressure drop and flow patterns for gas-liquid flow through packed beds obtained in the International Space Station with two types of packing are presented and analyzed. It is found that the pressure drop depends on the packing wettability in the viscous-capillary (V-C) regime and this dependence is compared with previously published results developed using short duration low-gravity aircraft tests. Within the V-C regime, the capillary contribution is the dominant force contributing to the pressure drop for the wetting case (glass) versus the viscous contribution dominating for the non-wetting case (Teflon). Outside of the V-C regime, it is also found that hysteresis effects that are often strong in normal gravity gas-liquid flows are greatly diminished in microgravity and pressure drop is nearly independent of packing wettability. A flow pattern transition map from bubble to pulse flow is also compared with the earlier aircraft data.

Viscous-capiliary regime↗

Correlation of spray dropsize distribution and injector variables

The atomization characteristics of impinging stream rocket engine injection elements are studied to determine the effects of hydraulic and geometric parameters on the mass median drop size. The major conclusions are: (1) the velocity profile of impinging jets affects mean drop size, this effect is greater when the jets are laminar than when they are turbulent; (2) the drop size/injection velocity dependence for turbulent jet impingement differs from that obtained with non-turbulent jets; (3) the level of turbulence intensity does not affect mean drop size; (4) the impingement of disintegrated or nearly disintegrated jets substantially decreases atomization; and (5) even though an emulsion is formed when immiscible jets impinge, the level of emulsification is small.

Zajac, L. J.↗

Transfer of thermal microwaves in the atmosphere, volume 2

Figures and tabular information that are supplemental to a study on transfer of thermal microwaves in the atmosphere are presented. The numerical values for the absorption and scattering cross sections of a pure, liquid, water drop are given for drop diameters ranging up to 6 mm, and for various drop temperatures. These values were obtained through the Mie theory. For a Marshall-Palmer distribution of drop sizes, the volume absorption and scattering coefficients of rain are given for the same temperatures and microwave frequencies shown above and for contents of liquid water in the rain mass. Also, scattergrams are given of the katabatic and upwelling brightness temperatures of up to 582 model atmospheres over a calm ocean versus the equivalent depths of liquid water in cloud form, rain form, or combined cloud and rain form.

Paris, J. F.↗

Velocity measurement of particles in sprays

The approach described makes use of high-speed photography employing short-duration light sources. Drops are photographed in flight as they pass through a narrow slice of the spray on which the optical system is focussed. Two sparks fired at intervals of a few microseconds give double image photographs of drops. Drop velocity is calculated by measuring the distance between the two images of the drop and the time interval between sparks. Details regarding the optical and photographic system are described along with the design of the electronics system.

Chigier, N. A.↗

Experimental and analytical determination of characteristics affecting light aircraft landing-gear dynamics

An experimental and analytical investigation was conducted to determine which characteristics of a light aircraft landing gear influence gear dynamic behavior significantly. The investigation focused particularly on possible modification for load control. Pseudostatic tests were conducted to determine the gear fore-and-aft spring constant, axial friction as a function of drag load, brake pressure-torque characteristics, and tire force-deflection characteristics. To study dynamic tire response, vertical drops were conducted at impact velocities of 1.2, 1.5, and 1.8 m/s onto a level surface; to determine axial-friction effects, a second series of vertical drops were made at 1.5 m/s onto surfaces inclined 5 deg and 10 deg to the horizontal. An average dynamic axial-friction coefficient of 0.15 was obtained by comparing analytical data with inclined surface drop test data. Dynamic strut bending and associated axial friction were found to be severe for the drop tests on the 10 deg surface.

Fasanella, E. L.↗

Comparison of two different raindrop disdrometers

Different types of impact sensors, used for the measurement of drop size distribution, are described and compared. All of them generate an electrical output which is to a first order a function of the velocity and mass of impacting drops within the size range of 0.25 to 5.0 mm. The disdrometers discussed include an active styrofoam disdrometer, a passive plexiglass sensor, and a cast epoxy disdrometer sensor. The sensors are calibrated by dropping water drops of known size on the sensor, and using an oscilloscope to measure peak amplitude. Similar response characteristics are observed for the active styrofoam disdrometer and the passive plexiglass and brass sensors. The cast epoxy impact sensor is noted to have a faster response and to be more sturdy than the styrofoam or plexiglass sensors.

Rowland, J. R.↗

Atomizing characteristics of swirl can combustor modules with swirl blast fuel injectors

Cold flow atomization tests of several different designs of swirl can combustor modules were conducted in a 7.6 cm diameter duct at airflow rates (per unit area) of 7.3 to 25.7 g/sq cm sec and water flow rates of 6.3 to 18.9 g/sec. The effect of air and water flow rates on the mean drop size of water sprays produced with the swirl blast fuel injectors were determined. Also, from these data it was possible to determine the effect of design modifications on the atomizing performance of various fuel injector and air swirler configurations. The trend in atomizing performance, as based on the mean drop size, was then compared with the trends in the production of nitrogen oxides obtained in combustion studues with the same swirl can combustors. It was found that the fuel injector design that gave the best combustor performance in terms of a low NOx emission index also gave the best atomizing performance as characterized by a spray of relatively small mean drop diameter. It was also demonstrated that at constant inlet air stream momentum the nitrogen oxides emission index was found to vary inversely with the square of the mean drop diameter of the spray produced by the different swirl blast fuel injectors. Test conditions were inlet air static pressures of 100,000 to 200,000 N/sq m at an inlet air temperature of 293 K.

Ingebo, R. D.↗