Study of comets at wavelengths between 0.5 and 18 microns

Since 1969 every bright comet was measured which has reached a distance of one astronomical unit from the sun. Observing techniques were developed which make it possible to observe as close as elongation 3 deg., and to find, track and measure comets at all wavelengths in full daylight. Comet Halley was measured on twenty four occasions between December 12, 1985 and March 25, 1986. Clear weather seems to come on holidays, and days on which are observed including Winter Solstice, Christmas, New Years, Valentines day, Super Bowl Sunday and the Vernal Equinox. Halley is observed within hours of perihelion passage.

Net, E. P.↗

Correlation of Space Shuttle Landing Performance with Post-Flight Cardiovascular Dysfunction

Introduction: Microgravity induces cardiovascular adaptations resulting in orthostatic intolerance on re-exposure to normal gravity. Orthostasis could interfere with performance of complex tasks during the re-entry phase of Shuttle landings. This study correlated measures of Shuttle landing performance with post-flight indicators of orthostatic intolerance. Methods: Relevant Shuttle landing performance parameters routinely recorded at touchdown by NASA included downrange and crossrange distances, airspeed, and vertical speed. Measures of cardiovascular changes were calculated from operational stand tests performed in the immediate post-flight period on mission commanders from STS-41 to STS-66. Stand test data analyzed included maximum standing heart rate, mean increase in maximum heart rate, minimum standing systolic blood pressure, and mean decrease in standing systolic blood pressure. Pearson correlation coefficients were calculated with the null hypothesis that there was no statistically significant linear correlation between stand test results and Shuttle landing performance. A correlation coefficient? 0.5 with a p<0.05 was considered significant. Results: There were no significant linear correlations between landing performance and measures of post-flight cardiovascular dysfunction. Discussion: There was no evidence that post-flight cardiovascular stand test data correlated with Shuttle landing performance. This implies that variations in landing performance were not due to space flight-induced orthostatic intolerance.

McCluskey, R.↗

Deep-Focusing Time-Distance Helioseismology

Much progress has been made by measuring the travel times of solar acoustic waves from a central surface location to points at equal arc distance away. Depth information is obtained from the range of arc distances examined, with the larger distances revealing the deeper layers. This method we will call surface-focusing, as the common point, or focus, is at the surface. To obtain a clearer picture of the subsurface region, it would, no doubt, be better to focus on points below the surface. Our first attempt to do this used the ray theory to pick surface location pairs that would focus on a particular subsurface point. This is not the ideal procedure, as Born approximation kernels suggest that this focus should have zero sensitivity to sound speed inhomogeneities. However, the sensitivity is concentrated below the surface in a much better way than the old surface-focusing method, and so we expect the deep-focusing method to be more sensitive. A large sunspot group was studied by both methods. Inversions based on both methods will be compared.

Duvall, T. L., Jr.↗

Evaluating generative networks using Gaussian mixtures of image features

We develop a measure for evaluating the performance of generative networks given two sets of images. A popular performance measure currently used to do this is the Fréchet Inception Distance (FID). However, FID assumes that images featurized using the penultimate layer of Inception follow a Gaussian distribution. This assumption allows FID to be easily computed, since FID uses the 2-Wasserstein distance of two Gaussian distributions fitted to the featurized images. However, we show that Inception features of the ImageNet dataset are not Gaussian; in particular, each marginal is not Gaussian. To remedy this problem, we model the featurized images using Gaussian mixture models (GMMs) and compute the 2-Wasserstein distance restricted to GMMs. We define a performance measure, which we call WaM, on two sets of images by using inception (or another classifier) to featurize the images, estimate two GMMs, and use the restricted 2-Wasserstein distance to compare the GMMs. We experimentally show the advantages of WaM over FID, including how FID is more sensitive than WaM to image perturbations. By modelling the non-Gaussian features obtained from inception as GMMs and using a GMM metric, we can more accurately evaluate generative network performance.

machine learning, genrative adversarial networks↗

Prediction of a measurable sign change in the Casimir force using a magnetic fluid

Here, we demonstrate quantum levitation controlled by Casimir forces acting between a polystyrene surface and a Teflon-coated metallic substrate immersed in a mixture of toluene and magnetite particles. This system experiences repulsion-attraction transitions in the Casimir interaction for distances where the effect is measurable. This Casimir trapping can be controlled by clever choices of metallic and ferrofluid materials, which are directly linked to the emergence of the trapping effect. Thermal and quantum contributions are investigated in detail, showing how the optical and magnetic properties of the ferrofluid and other materials affect the magnitude of the trapping and its distance range of observability.

Ma, Long [University of South Florida, Tampa, FL (↗

MAPS of Cancer

Our goal was to produce an interactive visualization from a mathematical model that successfully predicts metastases from head and neck cancer. We met this goal early in the project. The visualization is available for the public to view. Our work appears to fill a need for more information about this deadly disease. The idea of this project was to make an easily interpretable visualization based on what we call "functional maps" of disease. A functional map is a graphic summary of medical data, where distances between parts of the body are determined by the probability of disease, not by anatomical distances. Functional maps often beat little resemblance to anatomical maps, but they can be used to predict the spread of disease. The idea of modeling the spread of disease in an abstract multidimensional space is difficult for many people. Our goal was to make the important predictions easy to see. NASA must face this problem frequently: how to help laypersons and professionals see important trends in abstract, complex data. We took advantage of concepts perfected in NASA's graphics libraries. As an analogy, consider a functional map of early America. Suppose we choose travel times, rather than miles, as our measures of inter-city distances. For Abraham Lincoln, travel times would have been the more meaningful measure of separation between cities. In such a map New Orleans would be close to Memphis because of the Mississippi River. St. Louis would be close to Portland because of the Oregon Trail. Oklahoma City would be far from Little Rock because of the Cheyenne. Such a map would look puzzling to those of us who have always seen physical maps, but the functional map would be more useful in predicting the probabilities of inter-site transit. Continuing the analogy, we could predict the spread of social diseases such as gambling along the rivers and cattle rustling along the trails. We could simply print the functional map of America, but it would be more interesting to show meaningful patterns of dispersal. We had previously published the functional map of the head and neck, but it was difficult to explain to either patients or surgeons because that view of our body did not resemble anatomy. This discrepancy between functional and physical maps is just a mathematical restatement of the well-known fact that some diseases, such as head and neck cancer, spread in complex patterns, not always to the next nearest site. We had discovered that a computer could re-arrange anatomy so that this particular disease spreads to the next nearest site. The functional map explains over 95% of the metastases in 1400 patients. In a sense, we had graphed what our body "looks like" to a tumor. The tumor readily travels between adjacent areas in the functional map. The functional map is a succinct visual display of trends that are not easily appreciated in tables of probabilities.

Gray, Lincoln↗

New Method for the Astrometric Direct Detection of Ultralight Dark Matter

Ultralight dark matter induces time-dependent perturbations in the spacetime metric, enabling its . In this Letter, we propose using astrometry to detect dark matter. After reviewing the calculation of the metric in the presence of scalar dark matter, we study the influence of the perturbations on the apparent motion of astrophysical bodies. We apply our results to angular position measurements of quasars, whose vast distances from Earth present an opportunity to discover subcomponent dark matter with a mass as low as 10 − 33 eV . We explore the prospects of very long baseline interferometry and optical astrometric survey measurements for detecting ultralight relics, finding that for the smallest masses, current astrometric surveys can detect dark matter moving locally with a velocity of 10 − 3 with energy density as low as 3 × 10 − 11 GeV / cm 3 . Published by the American Physical Society 2025

Dror, Jeff A. (ORCID:0000000301106184)↗

Modification of Mach 6 Freestream Flow by Pitot Probe Bow Shock as Measured by Line FLDI and SAFS

Measurements of the flow in front of flat-face Pitot probes in NASA Langley ResearchCenter’s 20-Inch Mach 6 Air Tunnel were made using a 35-point line focused laser differentialinterferometer (FLDI), a two-point FLDI, and a self-aligned focusing schlieren system. Thesesystems were used to make measurements of flow unsteadiness between the bow shock andPitot probe face, while also probing the freestream region just upstream of the bow shock.Shock standoff distances from the non-intrusive measurements match closely with analyticalsolutions using the probe face diameter. Acoustic wave angles and velocities in the freestreamcompare favorably with DNS simulations of a Mach 6 freestream flow, and wave velocities in thepost-shock region slow as they approach the probe face. Peak frequencies in the post-shockregion as measured by FLDI compare favorably to the estimates computed from the shockstandoff distance for most probe diameters. With increasing unit Reynolds number, fluctuationintensities in the post-shock region were attenuated below the intensities of the freestream, witha spectral, spatial, and probe size dependence. Pitot probe power spectral density estimatesare presented from the test campaign, which can be compared with FLDI and SAFS data toevaluate the applicability of the transfer functions derived from computational simulations.

Joshua M Weisberger↗

Regression Convolutional Neural Network for Energy Estimation in NOvA

Regression Convolutional Neural Network for Energy Estimation in NOvA" Abstract: "NOvA (NuMI Off-Axis $\nu_e$ Appearance) is a long baseline neutrino experiment designed to measure neutrino oscillations over a distance of 810 km. NOvA employs a near and far detector to observe $\nu_\mu$ disappearance and $\nu_e$ appearance of neutrinos produced by the NuMI beam at Fermilab. Energy reconstruction is critical for precise measurements of neutrino oscillation parameters and cross sections, which are functions of neutrino energy. Energy estimation remains difficult due to the complexity of detector response and final state particle kinematics. We present a regression-based convolutional neural network (CNN) method that reconstructs neutrino and lepton energies based on raw pixel inputs for NOvA. The trained model is able to reconstruct event energy for different interaction modes and complex final states containing leptons and hadrons. Studies of regression CNN networks show improved energy resolution and reduced sensitivity to calibration scale uncertainties relative to traditional kinematics-based energy reconstruction techniques. The results demonstrate the potential of the regression CNN method for neutrino physics analyses by improving on standard kinematics-based reconstruction.

Zhao, Larry [UC, Irvine (main)]↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Sympathetic discharge and vascular resistance after bed rest

The effect of -6 degrees head-down-tilt bed rest (HDBR) for 14 days on supine sympathetic discharge and cardiovascular hemodynamics at rest was assessed. Mean arterial pressure, heart rate (n = 25), muscle sympathetic nerve activity (MSNA; n = 16) burst frequency, and forearm blood flow (n = 14) were measured, and forearm vascular resistance (FVR) was calculated. Stroke distance, our index of stroke volume, was derived from measurements of aortic mean blood velocity (Doppler) and R-R interval (n = 7). With these data, an index of total peripheral resistance was determined. Heart rate at rest was greater in the post (71 +/- 2 beats/min)- compared with the pre-HDBR test (66 +/- 2 beats/min; P < 0.003), but mean arterial pressure was unchanged. Aortic stroke distance during post-HDBR (15.5 +/- 1.1 cm/beat) was reduced from pre-HDBR levels (20.0 +/- 1.5 cm/beat) (P < 0.03). Also, MSNA burst frequency was reduced in the post (16.7 +/- 2.8 beats/min)- compared with the pre (25.2 +/- 2.6 beats/min)-HDBR condition (P < 0.01). Bed rest did not alter forearm blood flow, FVR, or total peripheral resistance. Thus reductions in MSNA with HDBR were not associated with a decrease in FVR.

NASA Discipline Musculoskeletal↗

Afterglows from gamma-ray bursters - A way to estimate the burster distance scale?

We calculate the strength of secondary gamma-ray signals that could be produced by positron annihilation in a medium surrounding a gamma-ray burster. We predict that such signals should be observable for a fairly wide range of conditions of this medium for bursts at both Galactic and cosmological distances. Furthermore, the time behavior of such signals together with the redshift measurement could be used to determine the distance scale to bursters.

Fencl, H. S.↗

Lidar for Guidance of a Spacecraft or Exploratory Robot

A report describes the Laser Mapper (LAMP) -- a lightweight, compact, low-power lidar system under development for guidance of a spacecraft or exploratory robotic vehicle (rover) at Mars or another planet. The LAMP is intended especially for use during rendezvous of two spacecraft in orbit, for mapping terrain during descent and landing of a spacecraft, for capturing a sample that has been launched into orbit, or navigation and avoidance of obstacles by a rover traversing terrain. The LAMP includes a laser that emits high-power, short light pulses. The laser beam is aimed in azimuth and elevation by use of a mirror on a two-axis gimbal, which scans the beam across a field of regard. Light reflected by a target is collected by a telescope, and the distance to the target is determined by measuring the round-trip travel time for reflected light pulses. The distance information is combined with directional information to construct a three-dimensional map of targets in the field of regard.

Liebe, Carl Christian↗

Measurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array

Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O 2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 10 16 cm -3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O 2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DESI 2024 VI: cosmological constraints from the measurements of baryon acoustic oscillations

We present cosmological results from the measurement of baryon acoustic oscillations (BAO) in galaxy, quasar and Lyman-α forest tracers from the first year of observations from the Dark Energy Spectroscopic Instrument (DESI), to be released in the DESI Data Release 1. DESI BAO provide robust measurements of the transverse comoving distance and Hubble rate, or their combination, relative to the sound horizon, in seven redshift bins from over 6 million extragalactic objects in the redshift range 0.1 < z < 4.2. To mitigate confirmation bias, a blind analysis was implemented to measure the BAO scales. DESI BAO data alone are consistent with the standard flat ΛCDM cosmological model with a matter density Ω m =0.295±0.015. Paired with a baryon density prior from Big Bang Nucleosynthesis and the robustly measured acoustic angular scale from the cosmic microwave background (CMB), DESI requires H 0 =(68.52±0.62) km s -1 Mpc -1 . In conjunction with CMB anisotropies from Planck and CMB lensing data from Planck and ACT, we find Ω m =0.307± 0.005 and H 0 =(67.97±0.38) km s -1 Mpc -1 . Extending the baseline model with a constant dark energy equation of state parameter w, DESI BAO alone requirew=-0.99 +0.15 -0.13 . In models with a time-varying dark energy equation of state parametrised by w 0 and w a , combinations of DESI with CMB or with type Ia supernovae (SN Ia) individually prefer w 0 > -1 and w a < 0. This preference is 2.6σ for the DESI+CMB combination, and persists or grows when SN Ia are added in, giving results discrepant with the ΛCDM model at the 2.5σ, 3.5σ or 3.9σ levels for the addition of the Pantheon+, Union3, or DES-SN5YR supernova datasets respectively. For the flat ΛCDM model with the sum of neutrino mass ∑ m ν free, combining the DESI and CMB data yields an upper limit ∑ m ν < 0.072 (0.113) eV at 95% confidence for a ∑ m ν > 0 (∑ m ν > 0.059) eV prior. These neutrino-mass constraints are substantially relaxed if the background dynamics are allowed to deviate from flat ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Postural Effects on Intracranial Pressure as Assessed Noninvasively

This study was designed to investigate effects of whole body tilting on intracranial compliance and pressure in six healthy volunteers by using a noninvasive ultrasonic device. Subjects were randomly tilted up or down sequentially at 60 degree, 30 degree head-up, supine, and 15 degree head-down position for one minute at each angle. We measured arterial blood pressure with a finger pressure cuff and changes in intracranial distance with an ultrasonic device. The device measures skull movement on the order of micro-meter. Our ultrasound technique demonstrates that skull movement is highly correlated (r$(circumflex){2}$=0.77) with intracranial pressure variations due to cerebral arterial pulsation. The amplitudes of arterial pressure (r$(circumflex){2}$=0.99 and those of intracranial distance changes (r$(circumflex){2}$=0.87) associated with one cardiac cycle were inversely correlated with the angle of tilt. The ratio of pulsation amplitudes for intracranial distance over arterial pressure also showed a significant increase as the angle of tilt was lowered (p=0.003). Thus, postural changes alter intracranial compliance in healthy volunteers and intracranial volume-buffering capacity is reduced in head-down position.

Ueno, Toshiaki↗

Measurement of vortex velocities over a wide range of vortex age, downstream distance and free stream velocity

A wind tunnel test was conducted to obtain vortex velocity signatures over a wide parameter range encompassing the data conditions of several previous researchers while maintaining a common instrumentation and test facility. The generating wing panel was configured with both a revolved airfoil tip shape and a square tip shape and had a semispan aspect of 4.05/1.0 with a 121.9 cm span. Free stream velocity was varied from 6.1 m/sec to 76.2 m/sec and the vortex core velocities were measured at locations 3, 6, 12, 24 and 48 chordlengths downstream of the wing trailing edge, yielding vortex ages up to 2.0 seconds. Wing pitch angles of 6, 8, 9 and 12 deg were investigated. Detailed surface pressure distributions and wing force measurements were obtained for each wing tip configuration. Correlation with vortex velocity data taken in previous experiments is good. During the rollup process, vortex core parameters appear to be dependent primarily on vortex age. Trending in the plateau and decay regions is more complex and the machanisms appear to be more unstable.

Rorke, J. B.↗

Multi-parameter distributed fiber optic sensing using double-Brillouin peak fiber in Brillouin optical time domain analysis

In this paper, we demonstrate a multi-parameter fiber sensing system based on stimulated Brillouin scattering in a double-Brillouin peak specialty fiber with enhanced Brillouin gain response. The amplitude level of the second Brillouin gain peak, which originated from the higher-order acoustic modes, has been improved with an approximately similar amplitude level to the first Brillouin gain peak from the fundamental acoustic mode. Compared to other multi-Brillouin peak fibers presented in the literature, the proposed fiber significantly reduces the measured Brillouin frequency shift error, thus improving strain and temperature accuracies. By utilizing the sensitivity values of the strain and temperature associated with each Brillouin gain spectrum (BGS) peak, a successful discriminative measurement of strain and temperature is performed with an accuracy of ±13 μɛ, and ±0.5 °C, respectively. The proposed double-Brillouin peak fiber appears to be a possible alternative to other multi-BGS peak fibers, for instance, large effective area fiber and dispersion compensating fibers, which are inherently accompanied by large measurement errors due to the weak Brillouin gain values originating from the higher-order acoustic modes. The demonstrated results show different strain and temperature coefficients of 47 kHz/µɛ, 1.15 MHz/°C for peak 1 and 51 kHz/µɛ, 1.37 MHz/°C for peak 2. Moreover, the enhanced BGS peak gains having nearly the same amplitude levels enable the discriminative measurement of strain and temperature. Such fibers in Brillouin interrogation eliminate the need for complex monitoring setups and reduce measurement errors. We recommend that for long-distance natural gas pipeline monitoring, where discriminative strain and temperature measurement is crucial, the proposed double-Brillouin peak fiber can be highly beneficial.

47 OTHER INSTRUMENTATION↗