Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

1st- and 2nd-order motion and texture resolution in central and peripheral vision

STIMULI. The 1st-order stimuli are moving sine gratings. The 2nd-order stimuli are fields of static visual texture, whose contrasts are modulated by moving sine gratings. Neither the spatial slant (orientation) nor the direction of motion of these 2nd-order (microbalanced) stimuli can be detected by a Fourier analysis; they are invisible to Reichardt and motion-energy detectors. METHOD. For these dynamic stimuli, when presented both centrally and in an annular window extending from 8 to 10 deg in eccentricity, we measured the highest spatial frequency for which discrimination between +/- 45 deg texture slants and discrimination between opposite directions of motion were each possible. RESULTS. For sufficiently low spatial frequencies, slant and direction can be discriminated in both central and peripheral vision, for both 1st- and for 2nd-order stimuli. For both 1st- and 2nd-order stimuli, at both retinal locations, slant discrimination is possible at higher spatial frequencies than direction discrimination. For both 1st- and 2nd-order stimuli, motion resolution decreases 2-3 times more rapidly with eccentricity than does texture resolution. CONCLUSIONS. (1) 1st- and 2nd-order motion scale similarly with eccentricity. (2) 1st- and 2nd-order texture scale similarly with eccentricity. (3) The central/peripheral resolution fall-off is 2-3 times greater for motion than for texture.

Pattern Recognition, Visual/physiology↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification of A Transition Edge Sensor Based Anti-Coincidence Detector for A Probe Class Mission

The Line Emission Mapper (or LEM) is an X-ray probe class mission aimed to study the physics of galaxy formation, with a large field-of-view, high-resolution transition-edge sensor (TES) microcalorimeter. Because of the diffuse and faint nature of LEM’s targets, a high-fidelity anticoincidence detector (anti-co) is essential to reduce instrument background below the level of sky background. Lying directly behind the LEM sensor, the anti-co will detect ~3 counts per second per square centimeter from background galactic cosmic rays and the secondary particles they induce to detect and flag any events that could be confused with a science photon in the 0.3-2 keV signal band of LEM. Our design spans an active region 4-cm in diameter. It consists of 12 quasiparticle-trap-assisted electrothermal-feedback (QET) channels, each with 100 parallel TESes with common bias lines. The TES is a narrow strip of Mo/Au bilayer. We present fabrication processes that maintain the transition temperature (T c ) in Mo/Au bilayer structures across the active region. We further present a new design based on a a-Si/W TES layer that has previously achieved reasonable uniformity in lab testing.

x-ray↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Skipper-CCDs: Current applications and future

This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments with these sensors is given, in the context of the Oscura experiment. First results from the characterization of Oscura sensors from the first 200 mm wafer-fabrication run with a new vendor are presented. The overall yield of the electron counting capability of these sensors is 71%. In conclusion, a noise of 0.087 e - RMS, with 1225 samples/pix, and a dark current of (0.031±0.013) e - /pix/day at 140 K were measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-lived axionlike particles from tau decays

Axionlike particles (ALPs) are well-motivated examples of light, weakly coupled particles in theories beyond the Standard Model. In this work, we study long-lived ALPs coupled exclusively to leptons in the mass range between 2⁢𝑚 𝑒 and 𝑚 𝜏 − 𝑚 𝑒 . For anarchic flavor structure the leptophilic ALP production in tau decays or from ALP-tau bremsstrahlung is enhanced thanks to derivative couplings of the ALP and can surpass production from electron and muon channels, especially for ALPs heavier than 𝑚 𝜇 . Using past data from high-energy fixed-target experiments such as CHARM and BEBC we place new constraints on the ALP decay constant 𝑓 𝑎 , reaching scales as high as 𝒪⁡(10 8 ) GeV in lepton-flavor-violating channels and 𝑓 𝑎 ∼ 𝒪⁡(10 2 ) GeV in lepton-flavor-conserving ones. We also present projections for the event-rate sensitivity of current and future detectors to ALPs produced at the Fermilab Main Injector, the CERN SPS, and in the forward direction of the LHC. We show that SHiP will be sensitive to 𝑓 𝑎 values that are over an order of magnitude above the existing constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the 136 Xe two-neutrino double-β-decay half-life via direct background subtraction in NEXT

Here, we report a measurement of the half-life of the 136 Xe two-neutrino double-β decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136 Xe-enriched and 136 Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34$_{-0.46}^{+0.80}$(stat)$_{-0.17}^{+0.30}$(sys)×10 21 yr is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-β-decay searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-section measurement of the 82 Kr ($p,γ$) 83 Rb reaction in inverse kinematics

The total cross section of the 82 Kr(p,γ) 83 Rb reaction was measured for the first time at effective center-of-mass energies between 2.4 and 3.0 MeV, within the relevant Gamow window for the astrophysical γ process. The experiment took place at the National Superconducting Cyclotron Laboratory at Michigan State University using the ReA facility. A 82 Kr beam was directed onto a hydrogen gas cell located at the center of the Summing NaI(Tl) (SuN) detector. Here, the obtained spectra were analyzed using the γ-summing technique and the extracted cross section was compared to standard statistical model calculations using the non-smoker and talys codes. The comparison indicates that standard statistical model calculations tend to overproduce the cross section of the 82 Kr(p,γ) 83 Rb reaction relative to the experimentally measured values. Furthermore, the experimental data were used to provide additional constraints on the nuclear level density and the γ-ray strength function used in the statistical model calculations.

59 ≤ A ≤ 89↗

resbos2 and the CDF W mass measurement

The recent collider detector at fermilab (CDF) W mass measurement of 80 , 433 ± 9 MeV is the most precise direct measurement. However, this result deviates from the Standard Model predicted mass of 80 , 359.1 ± 5.2 MeV by 7 σ . The CDF experiment used an older version of the esos code that was only accurate at NNLL + NLO , while the esos2 code is able to make predictions at N 3 LL + NNLO accuracy. We determine that the data-driven techniques used by CDF capture most of the higher order corrections, and using higher order corrections would have an impact on the CDF result in total at the 10 MeV level. Additionally, we investigate the effects from handling the width of the W boson on the mass, PDF correlations, and scale uncertainties. We find that these contributions are consistent with those obtained by CDF. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a muon collider

A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work.

43 PARTICLE ACCELERATORS↗

Fundamental physics studies in time domain and multi-messenger astronomy

The era of ime domain and multi-messenger astronomy is not only leading to the development of a much broader set of detectors and instruments for astrophysical observations, but is also providing the means for astronomy to tie directly to cutting-edge studies in physics. In this manner, fundamental physics (theory and experiment) coupled with a strong theoretical understanding of astrophysical phenomena (guided by high-performance computing simulations) can tie directly to the amazing new observations in astronomy. This paper discusses how physics, astrophysical models, and observations can not only help astronomy probe fundamental physics but guide the needs for next-generation astrophysical missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor Tracks the Sun From Any Angle

Sensor system locates Sun from any angle and generates error signals to point object toward Sun and follow its motion. Sun-sensor system includes three photodetectors, each with separate field of view defined by set of apertures. As equipment rotates about axis, detectors put out time-varying signals processed by external electronics to determine rotation rate and direction to Sun.

Birnbaum, M., M.↗

Development of optimized detector/spectrophotometer technology for low background space astronomy missions

This program was directed towards a better understanding of some of the important factors in the performance of infrared detector arrays at low background conditions appropriate for space astronomy. The arrays were manufactured by Aerojet Electrosystems Corporation, Azusa. Two arrays, both bismuth doped silicon, were investigated: an AMCID 32x32 Engineering mosiac Si:Bi accumulation mode charge injection device detector array and a metal oxide semiconductor/field effect transistor (MOS-FET) switched array of 16x32 pixels.

Jones, B.↗

BATSE's sky sensitivity map

The Burst and Transient Source Experiment (BATSE) detects any gamma-ray burst not obscured by the earth and intense enough to produce a sufficiently strong signal in at least two of its eight large area NaI detectors (LADs). For a given intensity, a LAD records a stronger signal from a source which directly faces it than from a source to its side. Thus, BATSE's detection of a gamma-ray burst may depend upon the burst's direction. We discuss the effect of this uneven exposure to the sky on the instrument's measurement of the distribution of gamma-ray burst directions and intensities, and we describe our method of accounting for the effect.

Brock, M. N.↗

The ALEXIS data processing package: An IDL based system

The Array of Low Energy X-ray Imaging Sensors (ALEXIS) experiment consists of a mini-satellite containing six wide angle EUV/ultrasoft x-ray telescopes. Its purpose is to map out the sky in three narrow (approximately 5 percent) bandpasses around 66, 71, and 93 eV. The 66 and 71 eV bandpasses are centered on intense Fe emission lines which are characteristic of million degree plasmas such as the one thought to produce the soft x-ray background. The 93 eV bandpass is not near any strong emission lines and is more sensitive to continuum sources. The mission will be launched on the Pegasus Air Launched Vehicle in the second half of 1992 into a 400-nautical-mile, high inclination orbit and will be controlled entirely from a small ground station located at Los Alamos. The project is a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratory, and the University of California-Berkeley Space Sciences Laboratory. The six telescopes are arranged in three pairs. As the satellite spins twice a minute they scan the entire anti-solar hemisphere. Each f/1 telescope consists of a spherical, multilayer-coated mirror with a curved, microchannel plate detector located at the prime focus. The multilayer coatings determine the bandpasses of the telescopes. The field of view of each telescope is 30 degrees with a spatial resolution of 0.5 degree, limited by spherical aberration. The data processing requirements for ALEXIS are large. Each event is one of the six telescopes is telemetered to the ground with its time of arrival and position on the detector. This information must be folded with the aspect solution for the satellite to reconstruct the direction on the sky from which the photon came. Because of the way the six telescopes scan the sky, the effective exposure calculation is also very computationally intensive. ALEXIS may generate up to 100 megabytes of raw data per day, which are converted into a gigabyte per day of processed data. While the processing job for ALEXIS is sizable, the programming staff is small. To maximize programming efficiency, and to make the best use of tools available in the public domain, we chose IDL as our software development platform. IDL was used from the start of instrument development through flight. We use IDL as a top-level executive for the processing tasks (replacing Unix shell scripts), as a device independent graphics engine, as a database manager, and as a final data manipulator. IDL routines spawn special purpose C programs to perform detailed telemetry deconvolution and other specialized functions. We discuss the use of IDL and C within the processing and archiving strategy for the ALEXIS data anlaysis system as implemented on a SPARCstation platform. We also show results from our End-to-End software simulation capability as processed by our analysis codes.

Bloch, J. J.↗

The Relationship of Ion Beams and Fast Flows in the Plasma Sheet Boundary Layer

We report new findings on the behavior of plasmas in the vicinity of the plasma sheet boundary layer (PSBL). A large geometrical factor detector on WIND (3D plasma experiment) has discovered a unidirectional ion beam streaming in the tailward direction missed by previous observations. This tailward beam is as intense as the earthward streaming beam and it is found just inside the outer edge of the PSBL where earthward streaming beams are observed. The region where this tailward beam is observed includes an isotropic plasma component which is absent in the outer edge where earthward streaming beams are found. When these different distributions are convolved to calculate the velocity moments, fast flows (greater than 400 km/s) result in the earthward direction and much slower flows (less than 200 km/s) in the tailward direction. These new findings are substantially different from previous observations. Thus, the interpretation of fast flows and earthward and counterstreaming ion beams in terms of a neutral line model must be reexamined.

Parks, G. K.↗