Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Calibration and Characterization of the NASA EOS Terra and Aqua MODIS Instruments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is operating on both of the Terra and Aqua missions within the NASA Earth Observing System (EOS). The Terra MODIS instrument began taking observations in February 2000 and the Aqua MODIS instrument began taking observations in June of 2002 and both continue to operate successfully up to the present time. The MODIS instrument scans the entire Earth every 24 hours at nominal spatial resolutions between 250 and 1000 meters. It has 36 spectral bands spanning the electromagnetic spectrum from the visible wavelengths mar 400 micrometers to the emissive thermal infrared wavelengths at 15 micrometers. The MODIS instruments produce approximately 40 geophysical products devoted to observing land, ocean, and atmospheric processes and trends. To meet the scientific objectives associated with the NASA Earth sciences efforts the MODIS instruments must be and have been carefully calibrated and the performance characterized to meet specifications and goals such as five percent radiance and two percent relative to the sun accuracy in the twenty bands providing reflected solar radiation observations and one percent radiance accuracy in the sixteen bands observing in the thermal infrared. Over the time spanning instrument development and the pre-launch calibration and characterization of the instrument through the years of operation in space, the performance of the MODIS instruments have changed in multiple ways and appropriate adjustments made in relevant algorithms and look-up tables necessary to produce observations that meet the scientific objectives and requirements. The changes have been quantified and accounted for through careful use of on-board calibration devices such as the Spectro-Radiometric Calibration Assembly (SRCA), the Solar Diffuser (SD) and its companion Solar Diffuser Stability Monitor (SDSM), deep-space and lunar observations, and calibration targets on the Earth's surface. The strictest and most difficult challenges have come in trying to meet the requirements for observing Ocean color and related ocean biology processes over time and space. Overall the MODIS observations have been very successful in providing valuable scientific and applications results. The essential capabilities of MODIS are to be provided in the future by the Visible and Infrared Imaging Radiometer Suite (VIIRS) on the National Polar Orbiting Environmental Satellite Series (NPOESS).

Salomonson, Vincent V.↗

High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

Siegmund, Oswald↗

Challenging Issues for On-orbit Calibration in the VIS and NIR

On-orbit calibration of Earth-observing sensors in the VIS and NIR spectral regions is usually performed using the sensors on-board devices such as internal lamp(s) or solar diffuser plate(s) to provide calibration parameters. For sensors with no (or with less reliable) on-board calibrators, lunar calibration or ground validation approaches are often used. Each of these has its own set of problems that need to be fully addressed in order to support high quality on-orbit calibration and characterization. Some science products, such as Ocean color, may impose more stringent requirements that demand greater calibration precision. This paper uses MODIS as an example to illustrate challenging issues involved in VIS and NIR on-orbit calibration. It focuses on the solar diffuser (SD) calibration approach, including the effects due to SD BRF, SD attenuation screen(s), and earthshine. The impact of optics (solar diffuser and scan mirror) on-orbit degradation, including changes in the sensor s response versus scan angle (RVS), on the calibration and subsequent data quality is also discussed.

Xiong, X.↗

Mercury Conditions for the MESSENGER Mission Simulated in High- Solar-Radiation Vacuum Tests

The MESSENGER (Mercury Surface, Space Environment, Geochemistry, and Ranging) spacecraft, planned for launch in March 2004, will perform two flybys of Mercury before entering a year-long orbit of the planet in September 2009. The mission will provide opportunities for detailed characterization of the surface, interior, atmosphere, and magnetosphere of the closest planet to the Sun. The NASA Glenn Research Center and the MESSENGER spacecraft integrator, the Johns Hopkins University Applied Physics Laboratory, have partnered under a Space Act Agreement to characterize a variety of critical components and materials under simulated conditions expected near Mercury. Glenn's Vacuum Facility 6, which is equipped with a solar simulator, can simulate the vacuum and high solar radiation anticipated in Mercury orbit. The MESSENGER test hardware includes a variety of materials and components that are being characterized during the Tank 6 vacuum tests, where the hardware will be exposed to up to 11 suns insolation, simulating conditions expected in Mercury orbit. In 2002, ten solar vacuum tests were conducted, including beginning of life, end of life, backside exposure, and solar panel thermal shock cycling tests. Components tested include candidate solar array panels, sensors, thermal shielding materials, and communication devices. As an example, for the solar panel thermal shock cycling test, two candidate solar array panels were suspended on a lift mechanism that lowered the panels into a liquid-nitrogen-cooled box. After reaching -140 C, the panels were then lifted out of the box and exposed to the equivalent of 6 suns (8.1 kilowatts per square meters). After five cold soak/heating cycles were completed successfully, there was no apparent degradation in panel performance. An anticipated 100-hr thermal shield life test is planned for autumn, followed by solar panel flight qualification tests in winter. Glenn's ongoing support to the MESSENGER program has been instrumental in identifying design solutions and validating thermal performance models under a very aggressive development schedule. The test data have assisted Johns Hopkins engineers in selecting a flight solar array vendor and a thermal shield design. MESSENGER is one in a series of missions in NASA's Discovery Program. Infrared thermography provides data on the thermal gradients in the MESSENGER components during high solar insolation vacuum testing.

Wong, Wayne A.↗

NASA Tech Briefs, June 2005

Topics covered include: Apparatus Characterizes Transient Voltages in Real Time; Measuring Humidity in Sealed Glass Encasements; Adaptable System for Vehicle Health and Usage Monitoring; Miniature Focusing Time-of-Flight Mass Spectrometer; Cryogenic High-Sensitivity Magnetometer; Wheel Electrometer System; Carbon-Nanotube Conductive Layers for Thin-Film Solar Cells; Patch Antenna Fed via Unequal-Crossed-Arm Aperture; LC Circuits for Diagnosing Embedded Piezoelectric Devices; Nanowire Thermoelectric Devices; Code for Analyzing and Designing Spacecraft Power System Radiators; Decision Support for Emergency Operations Centers; NASA Records Database; Real-Time Principal- Component Analysis; Fuzzy/Neural Software Estimates Costs of Rocket- Engine Tests; Multicomponent, Rare-Earth-Doped Thermal-Barrier Coatings; Reactive Additives for Phenylethynyl-Containing Resins; Improved Gear Shapes for Face Worm Gear Drives; Alternative Way of Shifting Mass to Move a Spherical Robot; Parylene C as a Sacrificial Material for Microfabrication; In Situ Electrochemical Deposition of Microscopic Wires; Improved Method of Manufacturing SiC Devices; Microwave Treatment of Prostate Cancer and Hyperplasia; Ferroelectric Devices Emit Charged Particles and Radiation; Dusty-Plasma Particle Accelerator; Frozen-Plug Technique for Liquid-Oxygen Plumbing; Shock Waves in a Bose-Einstein Condensate; Progress on a Multichannel, Dual-Mixer Stability Analyzer; Development of Carbon- Nanotube/Polymer Composites; Thermal Imaging of Earth for Accurate Pointing of Deep-Space Antennas; Modifications of a Composite-Material Combustion Chamber; Modeling and Diagnostic Software for Liquefying- Fuel Rockets; and Spacecraft Antenna Clusters for High EIRP.

Source record↗

NASA Tech Briefs, December 2012

The topics include: Pattern Generator for Bench Test of Digital Boards; 670-GHz Down- and Up-Converting HEMT-Based Mixers; Lidar Electro-Optic Beam Switch with a Liquid Crystal Variable Retarder; Feedback Augmented Sub-Ranging (FASR) Quantizer; Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring; Software Modules for the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol; Description and User Instructions for the Quaternion to Orbit v3 Software; AdapChem; Mars Relay Lander and Orbiter Overflight Profile Estimation; Extended Testability Analysis Tool; Interactive 3D Mars Visualization; Rapid Diagnostics of Onboard Sequences; MER Telemetry Processor; pyam: Python Implementation of YaM; Process for Patterning Indium for Bump Bonding; Archway for Radiation and Micrometeorite Occurrence Resistance; 4D Light Field Imaging System Using Programmable Aperture; Device and Container for Reheating and Sterilization; Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources; Membrane Shell Reflector Segment Antenna; High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves; Compact Autonomous Hemispheric Vision System; A Distributive, Non-Destructive, Real-Time Approach to Snowpack Monitoring; Wideband Single-Crystal Transducer for Bone Characterization; Numerical Simulation of Rocket Exhaust Interaction With Lunar Soil; Motion Imagery and Robotics Application (MIRA): Standards-Based Robotics; Particle Filtering for Model-Based Anomaly Detection in Sensor Networks; Ka-band Digitally Beamformed Airborne Radar Using SweepSAR Technique; Composite With In Situ Plenums; Multi-Beam Approach for Accelerating Alignment and Calibration of HyspIRI-Like Imaging Spectrometers; JWST Lifting System; Next-Generation Tumbleweed Rover; Pneumatic System for Concentration of Micrometer-Size Lunar Soil.

Source record↗

Atomic oxygen beam source for erosion simulation

A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

Cuthbertson, J. W.↗

Development of advanced diagnostics for characterization of burning droplets in microgravity

Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel droplet diameter, droplet regression rate, and the droplet internal temperature profiles or gradients at very high data rates in microgravity experiments.

Sankar, Subramanian↗

Characterization of an Autonomous Non-Volatile Ferroelectric Memory Latch

We present the electrical characterization of an autonomous non-volatile ferroelectric memory latch using the principle that when an electric field is applied to a ferroelectriccapacitor,the positive and negative remnant polarization charge states of the capacitor are denoted as either data 0 or data 1. The properties of the ferroelectric material to store an electric polarization in the absence of an electric field make the device non-volatile. Further the memory latch is autonomous as it operates with the ground, power and output node connections, without any externally clocked control line. The unique quality of this latch circuit is that it can be written when powered off. The advantages of this latch over flash memories are: a) It offers unlimited reads/writes b) works on symmetrical read/write cycles. c) The latch is asynchronous. The circuit was initially developed by Radiant Technologies Inc., Albuquerque, New Mexico.

John, Caroline S.↗

The fluorescence of chlorophyll and yellow substances in natural waters: A note on the problems of measurement and the importance of their remote sensing

There are two chromophylls which, if sensed remotely from high altitude, would revolutionize the ability to survey large areas of the world's oceans. The chromophylls of importance are: the photosynthetic pigments of plankton algae and a group of organic materials frequently termed dissolved yellow substances. These are derived from plants and carried into the ocean by fresh water inflow. The attenuation of light by phytoplankton is characterized by two distinctive bands (450, 675 nm) which represent absorption by chloroplastic pigments. Yellow substances are characterized by a strong ultraviolet absorption which tails over into the visible region. It is emphasized that chlorophyll determination could be a unique technique for estimating the extent of eutrophication in coastal waters, and that a high altitude observer equipped with temperature, chlorophyll and yellow substance sensors has the possibility of detecting the magnitude of eutrophication and its sources by using laser induced fluorescent devices.

Yentsch, C. S.↗

High-Voltage Clock Driver for Photon-Counting CCD Characterization

A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

Baker, Robert↗

NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

Automotive↗

Automating Microbial Directed Evolution For Bioengineering Applications

From a micro-biology perspective, directed evolution is a technique that uses controlled environmental pressures to select for a desired phenotype. Directed evolution has the distinct advantage over rational design of not needing extensive knowledge of the genome or pathways associated with a microorganism to induce phenotypes. However, there are currently limitations to the applicability of this technique including being time-consuming, error-prone, and dependent on existing assays that may lack selectivity for the given phenotype. The AADEC (Autonomous Adaptive Directed Evolution Chamber) system is a proof-of-concept instrument to automate and improve the technique such that directed evolution can be used more effectively as a general bioengineering tool. A series of tests using the automated system and comparable by-hand survival assay measurements have been carried out using UV-C radiation and Escherichia coli cultures in order to demonstrate the advantages of the AADEC versus traditional implementations of directed evolution such as random mutagenesis. AADEC uses UV-C exposure as both a source of environmental stress and mutagenesis, so in order to evaluate the UV-C tolerance obtained from the cultures, a manual UV-C exposure survival assay was developed alongside the device to compare the survival fractions at a fixed dosage. This survival assay involves exposing E. coli to UV-C radiation using a custom-designed exposure hood to control the flux and dose. Surviving cells are counted then transferred to the next iteration and so on for several iterations to calculate the survival fractions for each exposure iteration.This survival assay primarily serves as a baseline for the AADEC device, allowing quantification of the differences between the AADEC system over the manual approach. The primary data of comparison is survival fractions; this is obtained by optical density and plate counts in the manual assay and by optical density growth curve fits pre- and post-exposure in the automated case. This data can then be compiled to calculate trends over the iterations to characterize increasing UV-C resistance of the E.coli strains. The observed trends are statistically indistinguishable through several iterations from both sources.

Bioengineering↗

Volatile Organic Compounds Emitted from Air Fresheners: Plug-Ins at Home and Little Trees in Cars

Air fresheners contain volatile organic compounds (VOCs), some of which are possible hazardous air pollutants, carcinogens, or chemicals associated with adverse health effects such as asthma. This screening study identifies VOCs emitted from two types of air fresheners. Plug-in air fresheners are household products that release scents from a heated liquid. Little Tree air fresheners are commonly used solid devices designed to hang in from the rear view mirror in cars. VOCs that were released from heated samples of air fresheners were identified by gas chromatography mass spectroscopy (GCMS). Amongst VOCs commonly known to have scent properties, this screening also revealed the presence of compounds that are not associated with fragrances and that may have adverse health effects. In a pilot study to characterize how air fresheners affect air quality in real settings, air samples were collected on solid-phase microextraction (SPME) field samplers in a home setting and inside a vehicle, before and during air-freshener use. This pilot demonstrated some limited potential for SPME field samplers to track changes in VOC levels in real-life settings.

Adriana Pino-Delgado↗

A new characterization of the icing environment below 10,000 feet AGL from 7,000 miles of measurements in supercooled clouds

A growing requirement over the past decade for a new assessment of aircraft icing conditions in wintertime clouds at altitudes up to about 10,000 feet is discussed. The requirement was documented in past workshops and comes primarily from the helicopter community which wants ice-protected rotorcraft to meet increasing demands for all-weather operations. Currently, only a few of the larger helicopters are equipped with certification of ice-protection devices. This is because the current FAA criteria for design and certification of ice-protection equipment results in power and payload penalties that smaller rotorcraft cannot tolerate. The FAA criteria were actually designed for large, transport-category aircraft capable of flying to 20,000 feet or more. For this reason, there have been concerns that the current criteria may be too severe for low-performance aircraft, such as helicopters, which generally operate at altitudes below 10,000 feet.

Jeck, R. K.↗

Thermal Remote Anemometer Device

Thermal Remote Anemometer Device developed for remote, noncontacting, passive measurement of thermal properties of sample. Model heated locally by scanning laser beam and cooled by wind in tunnel. Thermal image of model analyzed to deduce pattern of airflow around model. For materials applications, system used for evaluation of thin films and determination of thermal diffusivity and adhesive-layer contact. For medical applications, measures perfusion through skin to characterize blood flow and used to determine viabilities of grafts and to characterize tissues.

Heyman, Joseph S.↗

Crystal regularity with high-resolution synchrotron X-radiation diffraction imaging

New, high-resolution sources of X-radiation such as monochromatic synchrotron radiation beams with subarcsec divergence allow observation of regularities in a range of crystals with sufficient clarity for comprehensive analyses, whose results can deepen understanding of the nature of various crystal irregularities, their sources, and their effects on device performance. An account is presented of the results thus achievable with irregularities encountered in lattice orientation and strain, grain and subgrain boundaries, dislocations, domain boundaries, additional phases, and surface scratches. Significant achievements to date encompass the observation of critical anomalies in lead tin telluride, the reconciliation of disparate observations of GaAs, the determination of the performance effects of irregularities in mercuric iodide, and the characterization of the origins of crystal growth in bismuth silicon oxide.

Steiner, Bruce↗