Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Development of large area, pico-second resolution photo-detectors and associated readout electronics

The Large Area Pico-second Photo-detectors described in this contribution incorporate a photo-cathode and a borosilicate glass capillary Micro-Channel Plate (MCP) pair functionalized by atomic layer deposition (ALD) of separate resistive and electron secondary emitters materials. They may be used for biomedical imaging purposes, a remarkable opportunity to apply technologies developed in HEP having the potential to make major advances in the medical world, in particular for Positron Emission Tomography (PET). If daisy-chained and coupled to fast transmission lines read at both ends, they could be implemented in very large dimensions. Initial testing with matched pairs of small glass capillary test has demonstrated gains of the order of 105 to 106. Compared to other fast imaging devices, these photo-detectors are expected to provide timing resolutions in the 10-100 ps range, and two-dimension position in the sub-millimeter range. A 6-channel readout ASIC has been designed in 130 nm CMOS technology and tested. As a result, fast analog sampling up to 17 GS/s has been obtained, the intrinsic analog bandwidth being presently under evaluation. The digitization in parallel of several cells in two microseconds allows getting off-chip digital data read at a maximum rate of 40 MHz. Digital Signal Processing of the sampled waveforms is expected achieving the timing and space resolutions obtained with digital oscilloscopes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform digitization for high resolution timing detectors with silicon photomultipliers

The results of time resolution studies with silicon photomultipliers (SiPMs) read out with high bandwidth constant fraction discrimination electronics were presented earlier [1-3]. Here we describe the application of fast waveform digitization readout based on the DRS4 chip [4], a switched capacitor array (SCA) produced by the Paul Scherrer Institute, to further our goal of developing high time resolution detectors based on SiPMs. The influence of the SiPM signal shape on the time resolution was investigated. Different algorithms to obtain the best time resolution are described, and test beam results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of energy loss of fractionally charged particles using Geant4

Over the years several rare-event search experiments have shown increasing interest to search for Fractionally Charged Particles (FCPs) within the data acquired in those experiments. This, in turn, has required the need for a framework to calculate accurately the energy loss expected from FCPs as they pass through the detector material. We have developed Monte Carlo methods within Geant4 to simulate for the first time energy loss of FCPs through different physics processes. The program can be used to calculate energy deposition distributions, a major component of any FCP search analysis, as they interact with detector material. We discuss the implementation and validation of the energy loss of FCPs using a typical detector material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IN-CORE FLUX SENSOR EVALUATIONS AT THE ATR CRITICAL FACILITY.

As part of an Idaho State University (ISU)–led Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) collaborative project that includes Idaho National Laboratory (INL) and the French Alternative Energies and Atomic Energy Commission (CEA), flux detector evaluations were completed to compare their accuracy, response time, and longduration performance. Special fixturing, developed by INL, allows real-time flux detectors to be inserted into various Advanced Test Reactor Critical Facility (ATRC) core positions to perform lobe power measurements, axial flux profile measurements, and detector crosscalibrations. Detectors initially evaluated in this program included miniature fission chambers, specialized self-powered neutron detectors (SPNDs), and specially developed commercial SPNDs. Results from this program provide important insights related to flux detector accuracy and resolution for subsequent ATR and CEA experiments and yield new flux data required for benchmarking models in the ATR Life Extension Program (LEP) Modeling Update Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Physics and Dark Matter Physics with Ultra-Low-Energy Germanium Detector

The status and plans of the TEXONO Collaboration on the development of ultra-low-energy germanium detectors with sub-keV sensitivities are reported. We survey the scientific goals which include the observation of neutrino-nucleus coherent scattering, the studies of neutrino magnetic moments, as well as the searches of WIMP dark matter. In particular, an energy threshold of 220{+-}10 eV at an efficiency of 50% were achieved with a four-channel prototype detectors each of an active mass of 5 g. New limits were set for WIMPs with mass between 3-6 GeV. The prospects of the realization of full-scale experiments are discussed. This detector technique makes the unexplored sub-keV energy window accessible for new neutrino and dark matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The exposure of the hybrid detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The 'hybrid' detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Irradiation tests of prototype self-powered gamma and neutron detectors

In the framework of the SCK.CEN-CEA Joint Instrumentation Laboratory, we are developing and optimizing a self-powered detector for selective in-core monitoring of the gamma field. Several prototypes with bismuth emitters were developed and tested in a pure gamma field (the PAGURE gamma irradiation facility at CEA) and in mixed neutron and gamma fields (in the OSIRIS reactor at CEA and in the BR2 reactor at SCK.CEN). Detailed MCNP modelling was performed to calculate the gamma and neutron sensitivities. Apart from a few failing prototypes, all detectors showed equilibrium signals proportional to the gamma field with a good long-term stability (under irradiation during several weeks). A tubular geometry design was finally selected as the most appropriate for in-core gamma detection, coupling a larger sensitivity with better response characteristics. In the same experiment in BR2 six prototype Self-Powered Neutron Detectors (SPNDs) with continuous sheaths (i.e. without any weld between the sensitive part and the cable) were extensively tested: two SPNDs with Co emitter, two with V emitter and two with Rh emitters, with varying geometries. All detector responses were verified to be proportional to the reactor power. The prompt and delayed response contributions were quantified. The signal contributions due to the impact of gamma rays were experimentally determined. The evolution of the signals was continuously followed during the full irradiation period. The signal-to-noise level was observed to be well below 1% in typical irradiation conditions. The absolute neutron and gamma responses for all SPNDs are consistent. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scintillation counter and wire chamber front end modules for high energy physics experiments

This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of {approx}20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with {approx}100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of {approx}4 {micro}s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of {approx}0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertically integrated pixel readout chip for high energy physics

We report on the development of the vertex detector pixel readout chips based on multi-tier vertically integrated electronics for the International Linear Collider. Some testing results of the VIP2a prototype are presented. The chip is the second iteration of the silicon implementation of the prototype, data-pushed concept of the readout developed at Fermilab. The device was fabricated in the 3D MIT-LL 0.15 {micro}m fully depleted SOI process. The prototype is a three-tier design, featuring 30 x 30 {micro}m{sup 2} pixels, laid out in an array of 48 x 48 pixels.

99 GENERAL AND MISCELLANEOUS↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Above-ground Antineutrino Detection for Nuclear Reactor Monitoring

Antineutrino monitoring of nuclear reactors has been demonstrated many times, however the technique has not as of yet been developed into a useful capability for treaty verification purposes. The most notable drawback is the current requirement that detectors be deployed underground, with at least several meters-water-equivalent of shielding from cosmic radiation. In addition, the deployment of liquid-based detector media presents a challenge in reactor facilities. We are currently developing a detector system that has the potential to operate above ground and circumvent deployment problems associated with a liquid detection media: the system is composed of segments of plastic scintillator surrounded by 6 LiF/ZnS:Ag. ZnS:Ag is a radio-luminescent phosphor used to detect the neutron capture products of lithium-6. Because of its long decay time compared to standard plastic scintillators, pulse-shape discrimination can be used to distinguish positron and neutron interactions resulting from the inverse beta decay (IBD) of antineutrinos within the detector volume, reducing both accidental and correlated backgrounds. Segmentation further reduces backgrounds by identifying the positron’s annihilation gammas, which are absent for most correlated and uncorrelated backgrounds. This work explores different configurations in order to maximize the size of the detector segments without reducing the intrinsic neutron detection efficiency. We believe this technology will ultimately be applicable to potential safeguards scenarios such as those recently described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of limited coverage effects on areal density measurements in inertial confinement fusion implosions

Accurate diagnosis of areal density ($\textit{ρR}$) is critical for the inference of performance metrics in inertial confinement fusion implosions. One potential source of error in this diagnosis is the existence of low mode perturbations in the imploding target, which lead to asymmetries in the inference of the $\textit{ρR}$ from different lines of sight. Here, the error accrued as a result of limited coverage of the sphere due to a finite number of detectors is quantified, and the development of a forward scatter measurement from the OMEGA neutron time-of-flight detectors is motivated. In this work, a method by which the 1D-equivalent 4 π-averaged $\langleρR\rangle$ can be reconstructed, if accurate mode information can be diagnosed by other means, is validated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and readout by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output signal. We measured a peak strain sensitivity of 1.5x10{sup -20} Hz{sup -1/2} at 2942.9 Hz. A strain sensitivity of better than 5x10{sup -20} Hz{sup -1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than 1 order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3 kHz range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Envelope Detector-Based Phase Fault Detection Method for Power System Grid Distortions

In this study, a phase fault detection algorithm is developed by employing the envelope detector method. The proposed method diagnoses faults among phases and defines fault areas in the incoming signal. The designed algorithm consists of three steps: analytical signal conversion, complex magnitude, and fault detection. Initially, an analytical signal is obtained from the incoming power signal to determine the instantaneous amplitude and phase of the signal. A complex magnitude operation is applied to analytical signals to display changes in amplitude. On the basis of the threshold values specified by the user, the last step identifies the distortion signal in terms of the type of error and size. The proposed method is tested with realistically simulated substation power signal data and real power system data from the Grid Event Signature Library. The obtained results revealed that the proposed method detects distortions accurately.

Alaca, Ozgur↗

A novel adaptive discrete cosine transform-domain filter for gap-inpainting of high resolution PET scanners

Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved CZT for Gamma Detection

The goal of the project is to advance the state of the art for spectroscopic and imaging detectors for nonproliferation uses by developing a fundamental understanding of defects limiting the performance of large-volume CZT detectors and fixing them, and increasing the detector size and electron mobility-lifetime product while reducing the cost of detector-grade crystals. Interaction points can be precisely determined in 3D for CZT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗