At least 991 records · Page 55

Generation of localized lower-hybrid current drive by temperature perturbations

Despite high demonstrated efficiency, lower-hybrid current drive (LHCD) has not been considered localized enough for neoclassical tearing mode (NTM) stabilization in tokamaks. This assessment must be reconsidered in view of the radiofrequency current condensation effect. Here we show that an island with a central hot spot induces significant localization of LHCD. Furthermore, in steady state tokamaks where a significant amount of current is provided by LHCD, passive stabilization of NTMs may occur automatically, particularly as islands become large, without requiring precise aiming of the wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation and control of nonlocal chiral currents in graphene superlattices by orbital Hall effect

Graphene-based superlattices offer a unique materials playground to exploit and control a higher number of electronic degrees of freedom, such as charge, spin, or valley for disruptive technologies. Recently, orbital effects, emerging in multivalley band structures lacking inversion symmetry, have been discussed as possible mechanisms for developing . Here, we report nonlocal transport measurements in small gap hBN/graphene/hBN moiré superlattices which reveal very strong magnetic field-induced chiral response which is stable up to sizable temperatures. The measured sign dependence of the nonlocal signal with respect to the magnetic field orientation clearly indicates the manifestation of emerging orbital magnetic moments. The interpretation of experimental data is well supported by numerical simulations, and the reported phenomenon stands as a formidable way of manipulation of the transverse flow of orbital information that could enable the design of orbitronic devices. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The generation of magnetic fields and electric currents in cometary plasma tails

Due to the folding of the interplanetary magnetic field into the tail as a comet sweeps through the interplanetary medium, the magnetic field in the tail can be built up to the order of 100 gammas at a heliocentric distance of about 1 AU. This folding of magnetic flux tubes also results in a cross-tail electric current passing through a neutral sheet. When streams of enhanced plasma density merge with the main tail, cross-tail currents as large as 1 billion A may result. A condition could arise which causes a significant fraction of this current to be discharged through the inner coma, resulting in rapid ionization. The typical time scale for such outbursts of ionization is estimated to be of the order of 10,000 sec, which is in reasonable agreement with observation.

Ip, W.-H.↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic In(0.53)Ga(0. 47)As power converter under blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 sq cm chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. This is the first report of such a multijunction TPV. This is not a traditional tandem cell in which the junctions are stacked vertically. The junctions are each about 1mm long by 1 cm wide and are laterally connected across the 1 sq cm device area. This multijunction design has the potential for lower I(sup 2)R power loss since the smaller PN junction area limits the current to one-eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(sup 2)R loss, analogous to the way power utilities avoid I(sup 2)P loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

Multijunction InGaAs thermophotovoltaic power converter

The experimental performance of a multijunction monolithic lattice-matched 0.74 eV InGaAs thermophotovoltaic (TPV) power converter under 980 C blackbody irradiation is reported. Eight InGaAs PN junctions grown epitaxially on a semi-insulating wafer were monolithically integrated in series to boost the approximately 0.4 V photovoltage per typical InGaAs junction to over 3 volts for the 1 cm(exp 2) chip. This chip was originally designed and characterized for free-space 1.3 micron laser power beaming. The power efficiency of this TPV device is 16% for that part of the blackbody spectrum above the material bandgap. The device is shown to deliver about 1 watt of output power when driven with enough light. This is the first report of such a multijunction TPV device. This is not a traditional tandem cell in which the junctions are stacked vertically. Eight 1 mm long by 1 cm wide junctions are laterally connected across the device area. This multijunction design has the potential for lower I(exp 2)R power loss since the smaller PN junction area limits the current to one eighth that of the equivalent surface area. In essence, the current is traded for voltage to avoid the I(exp 2)R loss, analogous to the way power utilities avoid I(exp 2)R loss in high-tension power lines, by transforming the high current, low voltage generated at a power plant into a high voltage at a low current before transmitting the power over great distances.

Wojtczuk, Steven↗

Certifying Auto-Generated Flight Code

Model-based design and automated code generation are being used increasingly at NASA. Many NASA projects now use MathWorks Simulink and Real-Time Workshop for at least some of their modeling and code development. However, there are substantial obstacles to more widespread adoption of code generators in safety-critical domains. Since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently the generated code still needs to be fully tested and certified. Moreover, the regeneration of code can require complete recertification, which offsets many of the advantages of using a generator. Indeed, manual review of autocode can be more challenging than for hand-written code. Since the direct V&V of code generators is too laborious and complicated due to their complex (and often proprietary) nature, we have developed a generator plug-in to support the certification of the auto-generated code. Specifically, the AutoCert tool supports certification by formally verifying that the generated code is free of different safety violations, by constructing an independently verifiable certificate, and by explaining its analysis in a textual form suitable for code reviews. The generated documentation also contains substantial tracing information, allowing users to trace between model, code, documentation, and V&V artifacts. This enables missions to obtain assurance about the safety and reliability of the code without excessive manual V&V effort and, as a consequence, eases the acceptance of code generators in safety-critical contexts. The generation of explicit certificates and textual reports is particularly well-suited to supporting independent V&V. The primary contribution of this approach is the combination of human-friendly documentation with formal analysis. The key technical idea is to exploit the idiomatic nature of auto-generated code in order to automatically infer logical annotations. The annotation inference algorithm itself is generic, and parametrized with respect to a library of coding patterns that depend on the safety policies and the code generator. The patterns characterize the notions of definitions and uses that are specific to the given safety property. For example, for initialization safety, definitions correspond to variable initializations while uses are statements which read a variable, whereas for array bounds safety, definitions are the array declarations, while uses are statements which access an array variable. The inferred annotations are thus highly dependent on the actual program and the properties being proven. The annotations, themselves, need not be trusted, but are crucial to obtain the automatic formal verification of the safety properties without requiring access to the internals of the code generator. The approach has been applied to both in-house and commercial code generators, but is independent of the particular generator used. It is currently being adapted to flight code generated using MathWorks Real-Time Workshop, an automatic code generator that translates from Simulink/Stateflow models into embedded C code.

Denney, Ewen↗

Aerospace technology development of three types of solid state remote power controllers for 120VDC with current ratings of five, and thirty amperes, one type having current limiting

The first generation of remote power controllers (RPC) developed included: a 5-ampere design (Type 1), capable of limiting maximum overload current to 15 amperes for .1 sec; and 5-ampere noncurrent (Type 2) and 30-ampere noncurrent (Type 3) limiting designs, both with selectable instant trip levels for high-current overload. Each design provides overcurrent protection through an inverse I squared T trip-out function with an automatic reset option and demonstrates step-applied fault capability with a 4000-ampere surge, fast-risetime (low-inductance) power source. They also meet MIL - STD - 461A specification for electromagnetic interference. The second generation RPCs traded off specification compliance for reduction in cost and complexity for the Type 1 and 2 designs and give comparable or improved performance in most areas. The noncurrent limiting RPC proved to be a more economical and feasible method of overload protection for certain load types.

Baker, D. E.↗

Ion-Scale Current Structures in Short Large-Amplitude Magnetic Structures

We investigate electric current structures in Short Large-Amplitude Magnetic Structures (SLAMS) in the terrestrial ion foreshock region observed by the Magnetospheric Multiscale mission. The structures with intense currents (|J|~1 𝜇𝐴/𝑚2) have scale lengths comparable to the local ion inertial length (di). One current structure type is a current sheet due to the magnetic field rotation of the SLAMS, and a subset of these current sheets can exhibit reconnection features including the electron outflow jet and X-line-type magnetic topology. The di-scale current sheet near the edge of a SLAMS propagates much more slowly than the overall SLAMS, suggesting that it may result from compression. The current structures also exist as magnetosonic whistler waves with fci < f < flh, where fci and flh are the ion cyclotron frequency and the lower- hybrid frequency, respectively.The field rotations in the current sheets and whistler waves generate comparable |J| and energy conversion rates. Electron heating is clearly observed in one whistler packet embedded in a larger-scale current sheet of the SLAMS, where the parallel electric field and the curvature drift opposite to the electric field energize electrons. The results give insight about the thin current structure generation and energy conversion at thin current structures in the shock transition region.

Shan Wang↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2022 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2022, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 2,000 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (947 GW) and battery storage (~680 GW) are – by far – the fastest growing resources in the queues; combined they accounted for over 80% of new capacity entering the queues in 2022. Substantial wind (300 GW) capacity is also seeking interconnection, 38% of which is for offshore projects (113 GW). In total, about 1,250 GW of zero-carbon generating capacity is currently seeking transmission access, as is 82 GW of natural gas capacity. Hybrids projects (co-locating multiple generation and/or storage types) comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 457 GW of solar hybrids (primarily solar+battery) and 24 GW of wind hybrids are currently active in the queues; over half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 21% of the projects (and 14% of capacity) seeking connection from 2000 to 2017 have been built as of the end of 2022. Additionally, interconnection wait times are on the rise: The typical duration from connection request to commercial operation increased from <2 years for projects built in 2000-2007 to nearly 4 years for those built in 2018-2022 (with a median of 5 years for projects built in 2022).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solvent-induced electrochemistry at an electrically asymmetric carbon Janus particle

Chemical doping through heteroatom substitution is often used to control the Fermi level of semiconductor materials. Doping also occurs when surface adsorbed molecules modify the Fermi level of low dimensional materials such as carbon nanotubes. A gradient in dopant concentration, and hence the chemical potential, across such a material generates usable electrical current. This opens up the possibility of creating asymmetric catalytic particles capable of generating voltage from a surrounding solvent that imposes such a gradient, enabling electrochemical transformations. In this work, we report that symmetry-broken carbon particles comprised of high surface area single-walled carbon nanotube networks can effectively convert exothermic solvent adsorption into usable electrical potential, turning over electrochemical redox processes in situ with no external power supply. The results from ferrocene oxidation and the selective electro-oxidation of alcohols underscore the potential of solvent powered electrocatalytic particles to extend electrochemical transformation to various environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Photospheric Current Spikes as Possible Predictors of Flares

Flares involve generation of the largest current densities in the solar atmosphere. This suggests the hypothesis that prior to a large (M,X) flare there are related time dependent changes in the photospheric current distribution, and hence in the resistive heating rate in neutral line regions (NLRs). If this is true, these changes might be useful predictors of flares. Evidence supporting this hypothesis is presented. Results from a data driven, near photospheric, 3D magnetohydrodynamic type model suggest the model might be useful for predicting M and X flares several hours to several days in advance. The model takes as input the photospheric magnetic field observed by the Helioseismic & Magnetic Imager (HMI) on the Solar Dynamics Observatory (SDO) satellite. The model computes quantities in every active region (AR) pixel for 14 ARs, with spurious Doppler periods due to SDO orbital motion filtered out of the time series of the magnetic field for each pixel. Spikes in the NLR resistive heating rate Q, appearing as increases by orders of magnitude above background values in the time series of Q are found to occur, and appear to be correlated with the occurrence of M or X flares a few hours to a few days later. The subset of spikes analyzed at the pixel level are found to occur on HMI and granulation scales of 1 arcsec and 12 minutes. Spikes are found in NLRs with and without M or X flares, and outside as well as inside NLRs, but the largest spikes are localized in the NLRs of ARs with M or X flares, and associated with horizontal magnetic field strengths several hG, and vertical magnetic field strengths several orders of magnitude smaller, suggesting that the spikes are associated with current sheets.

Goodman, Michael L.↗