Design and Analysis of an Integrated Additively Manufactured Test Article for Plasma-Facing Components

Current plasma-facing components (PFCs) used in helium-cooled divertor modules are complex structures with tungsten tile, steel sleeve components, and cartridges, all assembled in a helium-cooled multiple jet (HEMJ) structure. The goal of this project is to simplify the complex PFC design using additive manufacturing techniques to create a single integrated tungsten test article. Apart from the flexibility this opens up in exploring a wide array of geometries for the article, having a single integrated article significantly reduces the number of joints and parts in the article, thus reducing chances of leaks. A process called electron beam melting has shown to produce very high-density samples and unique geometries, enabling HEMJ or similar designs. To validate and optimize this novel design, the model underwent a series of computational fluid dynamics and finite element analysis simulations to replicate steady-state heat flux in the divertors. The simulations presented in this study consider a steady-state base heat flux of 5 MW/m 2 , with water serving as the coolant. Future research will explore the use of helium as a coolant, simulate edge-localized-mode conditions, and include experimental validation. Since 3D-printed tungsten is anisotropic, the build direction versus build plane of the article are taken into consideration for the test article strength. Because of the high operating temperatures and low ductility of tungsten, thermal creep and brittle fracture are important failure mechanisms to consider. In conclusion, the cap is evaluated with various flow velocities and nozzle diameters, and an optimal design choice is made for which this cap will survive the divertor conditions with a conservative safety margin.

Divertor↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vehicle-Cycle Inventory for Type C School Buses & Intra-City Transit Buses

This report documents the new inventory incorporated into the Research and Development version of Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) 2025 model for the vehicle cycle of Type C school buses and intracity transit buses. The transportation sector contributes significantly to the United States’ energy consumption and resultant emissions (EPA, 2025a). However, public transit plays an important role in mitigating these impacts because it consumes a relatively low amount of energy per passenger (Congressional Budget Office, 2022). Public transit is widely used in the United States; more than 500,000 school buses (EPA, 2025b) and ~75,000 service buses (American Public Transportation Association, 2025) operate in the nation. These are primarily internal combustion engine vehicles (ICEVs) powered by diesel. Original equipment manufacturers (OEMs) are making efforts to electrify U.S. bus fleets by using batteries as a propulsion system to replace internal combustion engines. Electrification can reduce tailpipe emissions, such as particulate matter (with a diameter ≤10 µm [PM 10 ] and with a diameter ≤2.5 µm [PM 2.5 ]) and nitrogen oxides (Jonas et al., 2025; Martinez and Samaras, 2024; EPA, 2025b; Wayne et al., 2009). Hence, any energy and emission impact analysis of public transit must consider both conventional ICEVs and upcoming electric vehicle (EV) options for the school and transit buses that dominate this landscape. To understand the detailed environmental impact profiles of ICEV and EV school and transit buses, it is necessary to conduct a thorough analysis covering both vehicle manufacturing and vehicle use stages. The current literature lacks a detailed vehicle-cycle inventory for school and transit buses, which makes this kind of comparison difficult. To overcome this gap, we developed a comprehensive vehicle-cycle model for school and transit buses in Argonne’s R&D GREET 2025 model. The model is flexible in handling user inputs for key assumptions, such as component weights and material compositions, upstream energy sources for material processing, and vehicle operating parameters, to understand their impacts on energy use and emissions for both school and transit buses. This report is organized as follows: Section 2 provides details on the modeling approach and vehicle specifications (weights and composition of different vehicle components, and vehicle operating parameters) for both school and transit buses. Section 3 provides details on vehicle assembly, disposal, and recycling (ADR) approaches for the two buses. Section 4 includes details about their incorporation into the R&D GREET model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Architects, Engineers, and Contractors - Key to Moving Towards a Zero Carbon Future: Preprint

Many building owners have set energy or carbon goals often citing targets of carbon neutrality in the next 10 to 30 years. Ultimately, these goals need to be translated into actions related to new and existing construction. Designers and contractors are key to designing solutions that meet the energy and carbon goals. As a voluntary program, the Design and Construction Allies (Allies program) was formed to identify barriers for the adoption of zero energy and zero carbon buildings (ZEZC). The goal was to understand why "all" buildings are not designed with ZEZC in mind. Currently the Allies program consists of 25 leading architecture, engineering, and construction firms that are seeking to take actionable steps to deliver buildings with the ZEZC goal. In the first year, the Allies have found numerous barriers and have implemented working groups to address key challenges that can be solved readily Allies. The paper will document program formulation and engagement strategies as well as the identified barriers and related recommendations for the design and construction community to shift towards ZEZC as a normal design and construction outcome. Two major topics rose to the top that the working groups were created to address: (1) providing guidance and knowledge to clients such that they will be active in creating ZEZC, and (2) bringing together knowledge around embodied carbon such that action can be taken to reduce this carbon emission area. Each working group has refined the barriers and created solutions that have been tested by Ally members. This rapid identification of barriers and subsequent creation of deployable solutions shows rapid change can happen.

design allies↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Green LEDs for Solid State Lighting

The development of white LEDs for solid state lighting (SSL) has been driven in recent years by phosphor converted LEDs (pc-LEDs). However, losses (known as Stokes’ losses) between the blue pump LED and phosphor impose a fundamental efficiency limit of ~300 lm/W on pc-LEDs. White light can also be generated from color mixed LEDs (cm-LEDs), which employ red, green, blue, and amber LEDs and have a fundamental efficiency limit of ~400 lm/W. Efficient group III-nitride materials are used for the blue LED, while efficient group III-phosphide materials are used for the red LED component. Currently, the poor efficiency of green and amber LEDs (i.e. the “green gap”) is the primary limitation for cm-LEDs. Relative to nitride-based blue LEDs, green and amber nitride LEDs suffer from lower radiative recombination rates and higher nonradiative recombination rates, which ultimately lead to reduced internal quantum efficiency (IQE). The IQE represents the portion of all electron-hole recombination events that result in a photon. In addition, long-wavelength LEDs have lower electrical efficiency (EE) compared to their blue counterparts. Addressing the green gap, would ultimately enable cm-LEDs that rival or exceed the performance of pc-LEDs. Our project focused on III-nitride materials growth and characterization, device fabrication and testing, and semiconductor physics to understand efficiency limitations of green LEDs and develop solutions to these challenges. Insights gained during our research has led to novel long-wavelength LED designs which will enable efficient solid-state lighting.

30 DIRECT ENERGY CONVERSION↗

Best practice reporting guideline for building stock energy models

Buildings are responsible for 38% of global greenhouse gas (GHG) emissions and, therefore, pathways to reduce their impact are crucial to achieve climate targets. Building stock energy models (BSEMs) have long been used as a tool to assess the current and future energy demand and environmental impact of building stocks. BSEMs have become more and more complex and are often tailored to case-specific datasets, which results in a high degree of heterogeneity among models. This heterogeneity, together with a lack of consistency in the reporting hinders the understanding of these models and, thereby, an accurate interpretation and comparison of results. In this paper we present a reporting guideline in order to improve reporting practices of BSEMs. The guideline was developed by experts as part of the IEA's Annex 70 and builds upon reporting guidelines from other fields. It consists of five topics (Overview, Model Components, Input and Output, Quality Assurance and Additional Information), which are further subdivided into subtopics. We explain which model aspects should be described in each subtopic, and provide illustrative examples on how to apply the guideline. In closing, the reporting guideline is consistent with the model classification framework and online model registry also developed in the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expanding market opportunities: cogeneration strategies for integrated PWR and thermal energy storage systems

We assess the economic viability of nuclear cogeneration by investigating three different modes—fixed dispatch, fully flexible dispatch, and flexible dispatch with minimum heat supply requirements. The analysis focuses on an existing pressurized water reactor (PWR) integrated with thermal energy storage (TES). Heat production costs are estimated under these modes for two U.S. electricity markets: the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania–New Jersey–Maryland Interconnection (PJM). A sensitivity analysis examines profitability at varying heat market prices. Results indicate that fixed heat dispatch inflates heat production costs, often rendering projects economically feasible only at higher heat price levels. Fully-flexible dispatch lowers heat production costs by an average of 43 % compared to fixed dispatch. However, the current 30 % thermal dispatch limit may be insufficient to serve high baseline industrial demands cost‐effectively; higher maximum dispatch rates could enhance project economics. Markets with higher and more volatile electricity prices (e.g., ERCOT) offer greater total energy sales potential (i.e., heat and electricity), but also increase opportunity costs when heat production scheduling restrictions are imposed. In contrast, lower-price, less volatile markets (e.g., PJM) experience smaller impacts from such constraints and provide greater flexibility in accommodating varying cogeneration modes. In conclusion, these findings provide a framework to guide nuclear plant operators in aligning cogeneration strategies with industrial process requirements and electricity market conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Abstract for CRADA between Capture6 CORP and NETL

The National Energy Technology Laboratory (NETL) and Capture6 CORP (Participant) will collaborate to refine Capture6’s transformative air contactor design for optimal direct air capture (DAC) under an awarded project from the Department of Energy’s Direct Air Capture Pre-Commercialization Technology Prize. Current cooling tower designs require exponentially more resources as the concentration of CO 2 in the gas phase decreases, resulting in a low conversion rate of carbonates, a large physical footprint, and high evaporation of water, which consequently limits the energy and water benefits that a DAC process can create. Capture6’s innovative tower design AURA (Absorption Unit Reactor for Ambient air) seeks to improve the mass transfer characteristics of legacy cooling towers and reduces total energy demand by: (1) introducing laminar and turbulent flow to increase mass transfer, (2) generating a solvent gradient to improve CO 2 absorption, (3) leveraging venturi and packed towers to increase the surface for the mass-transfer process, (4) adding charged/cool plates to reduce overall water loss in the system, and (5) utilizing surfactant additives to increase mass transfer. The collaboration will facilitate the deployment of technologies that reduce the total energy required and carbon footprint of solvent-based carbon dioxide removal (CDR) technologies. The anticipated results support NETL’s goal of fostering rapid development and commercialization pathways for technologies that remove CO 2 from the atmosphere.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Zero Energy Ready Manufactured Housing: Subject Matter Expert Technical Assistance Summary

Manufactured homes offer American consumers an affordable option for decent single-family detached housing. For working-class American families in many U.S. markets, manufactured homes are the first step toward home ownership. They now make up 10% of all new homes constructed in the United States, with higher percentages in the south and in rural communities. To help encourage the production of homes that are more durable, healthy, efficient, and disaster resistant, the U.S. Department of Energy is bringing its building science research to the manufactured housing industry through DOE’s Zero Energy Ready Manufactured Home (ZER-MH) program, which provides technical assistance and voluntary guidelines to manufactured home builders. Homes built to these guidelines are better able to handle power outages and less likely to experience moisture issues, offering a better product option for American families. This higher quality is evidenced by energy modeling which shows homes manufactured to these voluntary guidelines will typically use half the energy of manufactured homes built to the current minimum requirements of the U.S. Department of Housing and Urban Development (HUD)’s Manufactured Housing and Construction Safety Standard (MHCSS). These homes can also reduce critical energy demand during the busiest hours of the day, typically late afternoon and early evening in the summer when air conditioning demand is highest and mornings in the winter when furnaces and heaters are heating up. Reducing electricity demand during these peak periods when electricity rates are at their highest reduces costs for American families while freeing up capacity on overburdened energy distribution networks. Builders participating in the DOE ZER-MH program are eligible for a tax incentive via the 45L tax credit, which helps to offset the costs of ZER-MH upgrades, enabling builders to offer these certified homes at no additional cost. Together these factors enable manufactured homes to offer home buyers a housing option that is both affordable to finance and affordable to operate, with lower monthly mortgage payments and lower monthly energy bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Physics Topology Optimization for Dual Flow Heat Exchangers

Current heat exchanger (HX) designs are subjected to strict constraints pertaining to their manufacturability through conventional lengthy and expensive processes consisting of subtractive, forming and brazing processes. Therefore, existing HXs are typically restricted to the classical and rather simple geometries, such as plate-fin or shell-tube geometries, with lower efficiency and larger size. To increase HX efficiencies, novel designs are needed. Recent advances in topology optimization (TO) and additive manufacturing (AM) offer significant flexibility in design and fabrication of complex geometries, with potentially superior thermo-mechanical performance and high-power density. On the other hand, there is no commercially available software tool that addresses the combined coupling of structural, fluid dynamics, and thermal with multiple materials (hot and cold streams, solid, and void space) in TO of HXs. The goal of this project is to develop a multi-physics multi-phase TO approach to enhance the performance of HXs. The optimized design will be additively manufactured and tested in a physical environment to quantify its performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying System Level Impact of Connected and Automated Vehicles in an Urban Corridor

Numerous studies have demonstrated significant energy reduction for an ego vehicle by up to 20% leveraging Vehicle-to-Everything (V2X) technologies [1-4]. Some studies have also analyzed the impact of such vehicles on the energy consumption of other vehicles in a suburban or a highway corridor [5, 6], but the impact in an urban setting has not been studied yet. Southwest Research Institute (SwRI), in collaboration with Continental and Hyundai, is currently working on a Department of Energy funded project that is focused on quantifying the impact of multiple ego vehicles (smart vehicles) on the total energy consumption of the corridor under various traffic conditions, vehicle electrification level, vehicle-to-vehicle (V2V) technology penetration, and the number of smart (ego) vehicles in an urban setting. A six-kilometer-long urban corridor from Columbus, Ohio was modeled and calibrated with real-world data in PTV Vissim traffic microsimulation software. Five forward-looking powertrain models, consisting of two battery electric vehicles (BEVs), a hybrid electric vehicle (HEV), and two internal combustion engine (ICE) powered vehicles, were developed to estimate the energy consumption of vehicles on the corridor. A comprehensive full factorial simulation study was performed. The simulation results indicate that for a traffic mix based on projected new vehicles sales in 2025, a 15% corridor-level energy consumption reduction can be achieved. The paper details the development and validation of the simulation framework, design of experiments conducted, a discussion of challenges faced, and results under various test conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Vehicles, Biofuels, and Transitions in Transportation Energy

The decarbonization of power sources for light duty transportation is moving towards the use of renewable energies, biofuels, and electric vehicles. Currently there are three major light transportation fuels: gasoline (US gasoline is 98% E10), biofuels (E85), and electricity. Currently fuel ethanol in biofuels is obtained principally from corn in the US and sugarcane in Brazil with a small amount from cellulose. The transition to alternative fuels has been occurring since 1980, although light transportation still relies on gasoline. The rise of battery electric vehicles (BEV) is now beginning to offset internal combustion engines (ICE), while recent advances in biotechnology and integrated plant design have enhanced the economic feasibility of cellulosic biofuels. This paper explores the potential role of these fuels in reducing the carbon footprint associated with light transportation. We compare three different cases: Gasoline, E85 and full electric based on the Argonne AFLEET tool to calculate generation of greenhouse gases due to manufacturing and operation of BEV and ICE cars, respectively, in the US assuming an average useful automobile life of 200,000 miles or 12 years. We concluded that significant liquid fuel use (both renewable and non-renewable) will continue for the next 50 years. Here, renewable liquid fuels have an important role to play as the transportation sector transitions from petroleum to other energy sources.

09 BIOMASS FUELS↗