Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Explicit Aerosol Correction of OMI Formaldehyde Retrievals

Atmospheric aerosols are significant sources of uncertainty in air mass factor (AMF) calculations for trace gas retrievals using ultraviolet measurements from space. Current trace gas retrievals typically do not consider aerosols explicitly as cloud products partially account for aerosol effects. Here, we propose a new measurement-based approach to correct for aerosols explicitly in the AMF calculation, apply it to Ozone Monitoring Instrument (OMI) formaldehyde (HCHO) retrievals and quantify the aerosol-induced HCHO vertical column density difference for three aerosol types (smoke, dust, and sulfate) during 2006–2007. We use OMI aerosol retrievals for aerosol optical properties and vertical profiles to construct lookup tables of scattering weights as functions of geometry, surface pressure, surface albedo, and aerosol information. The average difference between the National Aeronautics and Space Administration operational OMI HCHO product (not considering aerosols) and the results obtained in this study on a global scale are 27%, 6%, and −0.3% for smoke, dust, and sulfate aerosols, respectively. The region with the largest aerosol effects is East China, where the explicit smoke aerosol correction enhances mean HCHO vertical column densities by 35%, with corrections to individual observations sometimes larger than 100%. The quantified aerosol effects are applicable under clear-sky conditions. This study highlights the need to implement aerosol corrections in the AMF calculation for HCHO retrievals. This is particularly relevant in regions with high levels of pollution where aerosols interfere the most with formaldehyde satellite observations.

Ozone Monitoring Instrument (OMI) formaldehyde (HC↗

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗

Neural Network Atmospheric Correction of Remote Sensing Imagery Over Water Using a Synthetic Dataset

Remote sensing atmospheric correction methods have primarily focused on imagery over land. However, accurate correction over water is important for monitoring and research of aquatic environments. More research in this area is ongoing, though one of the biggest challenges is enough quality data to develop and validate correction methods. This is especially true for neural network (NN) -based models which have shown promise in this area given enough quality data. To address this deficiency of data, we are leveraging a synthetic dataset produced by a model called SWIPE that uses radiative transfer modeling to simulate the atmospheric effects on water-leaving (WL) reflectance to estimate top-of-atmosphere (TOA) reflectance. This allows us to produce almost unlimited pairs of WL reflectance and corresponding TOA reflectance for model training across a variety of atmospheric conditions. We use two approaches for our atmospheric correction model. One uses a conditional variational autoencoder (VAE) to estimate a single WL reflectance value from a single TOA reflectance value. The second is based on a UNET architecture and estimates an array of WL reflectance values from an array of TOA reflectance values. The goal of the second method is to capture atmospheric effects that occur spatially between values within the array as compared to the first method.

deep learning↗

The Spectral Information Based Angular Correction Methodology for Satellite Intercalibration Applications

Satellite inter-calibration often requires collocated observations with minimized discrepancies in sun-view angles, observation times, and sensor characteristics. The collocation criteria directly impact achievable inter-calibration accuracy. Addressing potential angular mismatches in inter-calibration samples is critical but not as fully recognized and addressed as spatial-temporal mismatches in many studies. To achieve high-accuracy corrections for errors due to mismatched sun-view geometry angles, an angular correction algorithm has been developed for the Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission. This algorithm uses spectral correlation relationships to estimate differences in spectral radiances measured at different angles. This methodology can be extended for inter-calibrations between sensors measuring band radiances across a broad spectral region. We demonstrate its application in reducing angular mismatch errors between collocated measurements of multi-spectral imaging sensors, using the inter-calibration between the Moderate Resolution Imaging Spectrometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) as an example. The angular correction allows for more relaxed collocation criteria so that more satellite-based inter-calibration samples can be utilized. Furthermore, implementing the angular correction algorithm improves inter-calibration accuracy in applications where angular mismatch errors have not been explicitly addressed previously.

Wan Wu↗

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi↗

Area detector corrections for high quality synchrotron X-ray structure factor measurements

Correction procedures for obtaining accurate X-ray structure factors from large area detectors are considered, including subpanel effects, over excited pixels and careful intensity corrections. Problems associated with data normalization, the use of a pixel response correction from a glass standard and minimization of systematic errors are also discussed. Data from glassy GeSe{sub 2} and liquid water measured with a Perkin Elmer amorphous-Silicon detector are used to demonstrate the effectiveness of these correction procedures. This requires reduction of systematic errors in the measured intensity to around the 0.1% level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE CALCULATION OF BURNABLE POISON CORRECTION FACTORS FOR PWR FRESH FUEL ACTIVE COLLAR MEASUREMENTS

Verification of commercial low enriched uranium light water reactor fuel takes place at the fuel fabrication facility as part of the overall international nuclear safeguards solution to the civilian use of nuclear technology. The fissile mass per unit length is determined nondestructively by active neutron coincidence counting using a neutron collar. A collar comprises four slabs of high density polyethylene that surround the assembly. Three of the slabs contain {sup 3}He filled proportional counters to detect time correlated fission neutrons induced by an AmLi source placed in the fourth slab. Historically, the response of a particular collar design to a particular fuel assembly type has been established by careful cross-calibration to experimental absolute calibrations. Traceability exists to sources and materials held at Los Alamos National Laboratory for over 35 years. This simple yet powerful approach has ensured consistency of application. Since the 1980's there has been a steady improvement in fuel performance. The trend has been to higher burn up. This requires the use of both higher initial enrichment and greater concentrations of burnable poisons. The original analytical relationships to correct for varying fuel composition are consequently being challenged because the experimental basis for them made use of fuels of lower enrichment and lower poison content than is in use today and is envisioned for use in the near term. Thus a reassessment of the correction factors is needed. Experimental reassessment is expensive and time consuming given the great variation between fuel assemblies in circulation. Fortunately current modeling methods enable relative response functions to be calculated with high accuracy. Hence modeling provides a more convenient and cost effective means to derive correction factors which are fit for purpose with confidence. In this work we use the Monte Carlo code MCNPX with neutron coincidence tallies to calculate the influence of Gd{sub 2}O{sub 3} burnable poison on the measurement of fresh pressurized water reactor fuel. To empirically determine the response function over the range of historical and future use we have considered enrichments up to 5 wt% {sup 235}U/{sup tot}U and Gd weight fractions of up to 10 % Gd/UO{sub 2}. Parameterized correction factors are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method of absorbance correction in a spectroscopic heating value sensor

A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

47 OTHER INSTRUMENTATION↗

Off-Angle Iris Correction Methods

In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

iris recognition↗

Time-dependent phase error correction using digital waveform synthesis

The various technologies presented herein relate to correcting a time-dependent phase error generated as part of the formation of a radar waveform. A waveform can be pre-distorted to facilitate correction of an error induced into the waveform by a downstream operation/component in a radar system. For example, amplifier power droop effect can engender a time-dependent phase error in a waveform as part of a radar signal generating operation. The error can be quantified and an according complimentary distortion can be applied to the waveform to facilitate negation of the error during the subsequent processing of the waveform. A time domain correction can be applied by a phase error correction look up table incorporated into a waveform phase generator.

42 ENGINEERING↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗

Validation of Hadron Mass Correction Schemes in Deep Inelastic Scattering at Low Energy Transfer

One method of describing the quark-gluon of the structure proton relies on factorizing its cross-section into a process-dependent short distance element and an independent long distance element that quantifies the quark and gluon momentum distributions within the proton. This research focuses on validating the kinematic range at which factorization theorems still accurately describe the cross-section, in particular for events that simulate scattering on large momentum quarks, that are sensitive to the details of the color mechanism. In this regime, effects which otherwise scale away at large energies, become non-negligible at low energies. The goal of this research is to assess the viability of an extended version of ?collinear factorization? recently proposed by J. Guerrero and A. Accardi, which includes kinematic corrections at quark level, known as ?hadron mass corrections?, to account for the masses of the quarks and the target. To accomplish this, deep inelastic scattering events are simulated using a realistic model of deep inelastic scattering, in which one may analytically calculate both the structure functions and the quark distribution functions. These simulated experiments are then used to test the viability of the proposed factorization theorem by fitting the quark distributions and comparing these to the analytically calculable ones. It is found that the viability of hadron mass corrections in low energy scattering experiments, such as those at Jefferson Lab, extends beyond the kinematic range suggested by analytic calculations alone, provided that residual higher twist corrections are simultaneously fitted to the data.

Krause, Andrew↗

QCD Corrections in Transversely Polarized Scattering

We discuss two recent calculations of higher-order QeD corrections to scattering of transversely polarized hadrons. A basic concept underlying much of the theoretical description of high-energy hadronic scattering is the factorization theorem, which states that large momentum-transfer reactions may be factorized into long-distance pieces that contain information on the structure of the nucleon in terms of its parton densities, and parts that are short-distance and describe the hard interactions of the partons. Two crucial points are that on the one hand the long-distance contributions are universal, i.e., they are the same in any inelastic reaction under consideration, and that on the other hand the short-distance pieces depend only on the large scales related to the large momentum transfer in the overall reaction and, therefore, may be evaluated using QCD perturbation theory. The lowest order for the latter can generally only serve to give a rough description of the reaction under study. It merely captures the main features, but does not usually provide a quantitative understanding. The first-order ('next-to-leading order' (NLO)) corrections are generally indispensable in order to arrive at a firmer theoretical prediction for hadronic cross sections, and in some cases even an all-order resummation of large perturbative corrections is needed. In the present paper we win discuss two calculations [1, 2] of higher-order QeD corrections to transversely polarized scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The correction of linear lattice gradient errors using an AC dipole

Precise measurement of optics from coherent betatron oscillations driven by ac dipoles have been demonstrated at RHIC and the Tevatron. For RHIC, the observed rms beta-beat is about 10%. Reduction of beta-beating is an essential component of performance optimization at high energy colliders. A scheme of optics correction was developed and tested in the RHIC 2008 run, using ac dipole optics for measurement and a few adjustable trim quadruples for correction. In this scheme, we first calculate the phase response matrix from the. measured phase advance, and then apply singular value decomposition (SVD) algorithm to the phase response matrix to find correction quadruple strengths. We present both simulation and some preliminary experimental results of this correction.

43 PARTICLE ACCELERATORS↗

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more accurate set of dense correspondences results from the feedback-based process, as proven by more accurate pose and structure estimates.

99 GENERAL AND MISCELLANEOUS↗

Global optimization of data quality checks on 2-D and 3-D networks of GPR cross-well tomographic data for automatic correction of unknown well deviations

Significant errors related to poor time zero estimation, well deviation or mislocation of the transmitter (TX) and receiver (RX) stations can render even the most sophisticated modeling and inversion routine useless. Previous examples of methods for the analysis and correction of data errors in geophysical tomography include the works of Maurer and Green (1997), Squires et al. (1992) and Peterson (2001). Here we follow the analysis and techniques of Peterson (2001) for data quality control and error correction. Through our data acquisition and quality control procedures we have very accurate control on the surface locations of wells, the travel distance of both the transmitter and receiver within the boreholes, and the change in apparent zero time. However, we often have poor control on well deviations, either because of economic constraints or the nature of the borehole itself prevented the acquisition of well deviation logs. Also, well deviation logs can sometimes have significant errors. Problems with borehole deviations can be diagnosed prior to inversion of travel-time tomography data sets by plotting the apparent velocity of a straight ray connecting a transmitter (TX) to a receiver (RX) against the take-off angle of the ray. Issues with the time-zero pick or distances between wells appear as symmetric smiles or frown in these QC plots. Well deviation or dipping-strong anisotropy will result in an asymmetric correlation between apparent velocity and take-off angle (Figure 1-B). In addition, when a network of interconnected GPR tomography data is available, one has the additional quality constraint of insuring that there is continuity in velocity between immediately adjacent tomograms. A sudden shift in the mean velocity indicates that either position deviations are present or there is a shift in the pick times. Small errors in well geometry may be effectively treated during inversion by including weighting, or relaxation, parameters into the inversion (e.g. Bautu et al., 2006). In the technique of algebraic reconstruction tomography (ART), which is used herein for the travel time inversion (Peterson et al., 1985), a small relaxation parameter will smooth imaging artifacts caused by data errors at the expense of resolution and contrast (Figure 2). However, large data errors such as unaccounted well deviations cannot be adequately suppressed through inversion weighting schemes. Previously, problems with tomograms were treated manually. However, in large data sets and/or networks of data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Mislocation of the transmitter and receiver stations of GPR cross-well tomography data sets can lead to serious imaging artifacts if not accounted for prior to inversion. Previously, problems with tomograms have been treated manually prior to inversion. In large data sets and/or networks of tomographic data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Our approach is to use cross-well data quality checks and a simplified model of borehole deviation with particle swarm optimization (PSO) to automatically correct for source and receiver locations prior to tomographic inversion. We present a simple model of well deviation, which is designed to minimize potential corruption of actual data trends. We also provide quantitative quality control measures based on minimizing correlations between take-off angle and apparent velocity, and a quality check on the continuity of velocity between adjacent wells. This methodology is shown to be accurate and robust for simple 2-D synthetic test cases. Plus, we demonstrate the method on actual field data where it is compared to deviation logs. This study shows the promise for automatic correction of well deviations in GPR tomographic data. Analysis of synthetic data shows that very precise estimates of well deviation can be made for small deviations, even in the presence of static data errors. However, the analysis of the synthetic data and the application of the method to a large network of field data show that the technique is sensitive to data errors varying between neighboring tomograms.

54 ENVIRONMENTAL SCIENCES↗

Optical analysis for simplified astigmatic correction of non-imaging focusing heliostat

In the previous work, non-imaging focusing heliostat that consists of m x n facet mirrors can carry out continuous astigmatic correction during sun-tracking with the use of only (m + n - 2) controllers. For this paper, a simplified astigmatic correction of non-imaging focusing heliostat is proposed for reducing the number of controllers from (m + n - 2) to only two. Furthermore, a detailed optical analysis of the new proposal has been carried out and the simulated result has shown that the two-controller system can perform comparably well in astigmatic correction with a much simpler and more cost effective design. (author)

14 SOLAR ENERGY↗

Future Climate Projections for South Florida: Improving the Accuracy of Air Temperature and Precipitation Extremes With a Hybrid Statistical Bias Correction Technique

Projecting future climate variables is essential for comprehending the potential impacts on hydroclimatic hazards like floods and droughts. Evaluating these impacts is challenging due to the coarse spatial resolution of global climate models (GCMs); therefore, bias correction is widely used. Here, we applied two statistical methods—standard empirical quantile mapping (EQM) and a hybrid approach, EQM with linear correction (EQM-LIN)—to bias correct precipitation and air temperature simulated by nine GCMs. We used historical observations from 20 weather stations across South Florida to project future climate under three shared socioeconomic pathways (SSPs). Compared to the EQM, the hybrid EQM-LIN method improved R 2 of daily quantiles by up to 30% over the historical period and improved MAE up to 70% in months that contain most extreme values. Projected extreme precipitation at the weather stations showed that, compared to the EQM-LIN, the EQM method underestimates the high quantiles by up to 26% in SSP585. The projected changes in annual maximum precipitation from historical period (1985–2014) to near future (2040–2069) and far future (2070–2100) were between 2% and 16% across the study area. Projected future precipitation suggested a slight decrease during summer but an increase in fall. This, along with rising summer temperatures, suggested that South Florida can experience rapid oscillations from warmer summers and increased flooding in fall under future climate. Additionally, our comparative analyses with globally and nationally downscaled studies showed that such coarse scale studies do not represent the climatic extremes well, particularly for high quantile precipitation.

54 ENVIRONMENTAL SCIENCES↗