Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Detector systems for ISO's photometer ISOPHOT

One of the four focal plane instruments of the Infrared Space Observatory (ISO) is ISOPHOT, a photopolarimeter for the wavelength region 3 to 200 microns. Each experiment occupies a quadrant of the focal plane. The telescope beam is directed into each experiment by means of a pyramid mirror and by tilting the satellite. The diameter of the unvignetted field of view is 3 arcmin or 7.85 mm in the focal plane (1 mm = 23 arcsec). The temperatures provided are 3 K for cooling the detector systems and 8 K for the experiment structure. Available detectors are described along with the current status of the experiment.

Wolf, J.↗

The chemistry of Saudi Arabian sand: A deposition problem on helicopter turbine airfoils

Recent operations in the Persian Gulf have exposed military helicopter turbines to excessive amounts of ingested sand. Fine particles, less than 10 microns, are able to bypass the particle separators and enter the cooling and combustion systems. The initial sand chemistry varies by location, but is made up of a calcium aluminum silicate glass, SiO2 low quartz (Ca,Mg) CO3 dolomite, CaCO3 calcite, and occasionally CaCl rocksalt. The sand reacts in the hot combustion gases and deposits onto the turbine vanes as CaSO4, glass, and various crystalline silicates. Deposits up to 0.25 in. thick have been collected. Although cooling hole plugging is a considerable problem, excessive corrosion is not commonly observed due to the high melting point of GaSO4.

Smialek, James L.↗

The Chemistry of Saudi Arabian Sand - A Deposition Problem on Helicopter Turbine Airfoils

Operations in the Persian Gulf have exposed military helicopter turbines to excessive amounts of ingested sand. Fine particles, less than 10 microns, are able to bypass the particle separators and enter the cooling and combustion systems. The initial sand chemistry varies by location, but is made up of a calcium aluminum silicate glass, SiO2 low quartz, (Ca,Mg)CO3 dolomite, CaCO3 calcite, and occasionally NaCl rocksalt. The sand reacts in the hot combustion gases and deposits onto the turbine vanes as CaSO4, glass, and various crystalline silicates. Deposits up to 5 mm thick have been collected. Although cooling hole plugging is a considerable problem, excessive corrosion is not commonly observed due to the high melting point of CaSO4.

Smialek, James L.↗

Solar-Energy System for a Commercial Building--Topeka, Kansas

Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.

Source record↗

Shuttle compatible cryogenic liquid storage and supply systems

A detailed introduction is given to a wide variety of orbital cryogenic liquid storage and supply systems required for future vehicles by NASA and DOD. The systems include small cooling applications, large chemical and electrical orbit transfer vehicles and resupply tankers, and all have the common requirements of low-g fluid management for the accomplishment of gas-free liquid expulsion, and efficient thermal control in order to manage heat leak and tank pressure. The present study considers hydrogen, oxygen, methane, argon and helium tanks ranging from 0.6 to 37.4 cu m. Conceptual designs were generated for each tank system, and fluid dynamic, structural and thermal analyses were performed in view of Shuttle requirements.

Eberhardt, R. N.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

NASA needs and trends in cryogenic cooling

Projected NASA needs in spaceborne cryogenic systems and recent results of NASA cryogenic cooling technology efforts in infrared astronomy, X-ray astronomy, gamma ray astronomy, liquid helium and space stations are discussed.

Sherman, A.↗

Analysis of building heating and cooling

Energy Conservation Program (ECP) gives design engineer methodology and easy-to-use computer program for simulating hourly thermal characteristics over full year for individually characterized zones within building. Inexpensive system can be used to develop thermal model of building to aid selection of most suitable and economical heating and cooling system for building

Chai, V. W.↗

Conceptual design and analysis of orbital cryogenic liquid storage and supply systems

A wide variety of orbital cryogenic liquid storage and supply systems are defined in NASA and DOD long-range plans. These systems include small cooling applications, large chemical and electrical orbit transfer vehicles and supply tankers. All have the common requirements of low-g fluid management to accomplish gas-free liquid expulsion and efficient thermal control to manage heat leak and tank pressure. A preliminary design study was performed to evaluate tanks ranging from 0.6 to 37.4 cu m (22 to 1320 cu ft). Liquids of interest were hydrogen, oxygen, methane, argon and helium. Conceptual designs were generated for each tank system and fluid dynamic, thermal and structural analyses were performed for Shuttle compatible operations. Design trades considered the paradox of conservative support structure and minimum thermal input. Orbital performance and weight data were developed, and a technology evaluation was completed.

Eberhardt, R. N.↗

Altitude-Wind-Tunnel Investigation of a 4000-Pound-Thrust Axial-Flow Turbojet Engine. II - Operational Characteristics: Operational Characteristics - II

An investigation was conducted in the Cleveland altitude wind tunnel to determine the operational characteristics of an axial flow-type turbojet engine with a 4000-pound-thrust rating over a range of pressure altitudes from 5,000 to 50,OOO feet, ram pressure ratios from 1.00 to 1.86, and temperatures from 60 deg to -50 deg F. The low-flow (standard) compressor with which the engine was originally equipped was replaced by a high-flow compressor for part of the investigation. The effects of altitude and airspeed on such operating characteristics as operating range, stability of combustion, acceleration, starting, operation of fuel-control systems, and bearing cooling were investigated. With the low-flow compressor, the engine could be operated at full speed without serious burner unbalance at altitudes up to 50,000 feet. Increasing the altitude and airspeed greatly reduced the operable speed range of the engine by raising the minimum operating speed of the engine. In several runs with the high-flow compressor the maximum engine speed was limited to less than 7600 rpm by combustion blow-out, high tail-pipe temperatures, and compressor stall. Acceleration of the engine was relatively slow and the time required for acceleration increased with altitude. At maximum engine speed a sudden reduction in jet-nozzle area resulted in an immediate increase in thrust. The engine started normally and easily below 20,000 feet with each configuration. The use of a high-voltage ignition system made possible starts at a pressure altitude of 40,000 feet; but on these starts the tail-pipe temperatures were very high, a great deal of fuel burned in and behind the tail-pipe, and acceleration was very slow. Operation of the engine was similar with both fuel regulators except that the modified fuel regulator restricted the fuel flow in such a manner that the acceleration above 6000 rpm was very slow. The bearings did not cool properly at high altitudes and high engine speeds with a low-flow compressor, and bearing cooling was even poorer with a high-flow compressor.

Fleming, William A.↗

Automated Cryocooler Monitor and Control System Software

This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

Britchcliffe, Michael J.↗

Sorption cryogenic refrigeration - Status and future

The operation principles of sorption cryogenic refrigeration are discussed. Sorption refrigerators have virtually no wear-related moving parts, have negligible vibration, and offer extremely long life (at least ten years), making it possible to obtain efficient, long life and low vibration cooling to as low as 7 K for cryogenic sensors. The physisorption and chemisorption systems recommended for various cooling ranges down to 7 K are described in detail. For long-life cooling at 4-5 K temperatures, a hybrid chemisorption-mechanical refrigeration system is recommended.

Jones, Jack A.↗

Advanced Film Cooling Rig: Development and Test Results

The Advanced Film Cooling Rig (AFCR) test was a program to develop a thermal imaging camera system to measure the effectiveness of multihole film cooling. This system was used to evaluate low-thermal conductivity ceramic test panels incorporating a wide range of multihole cooling geometries. Tests were conducted with a mainstream flow of 600 F at Mach numbers of 0.37 and 1.57. Coolant flow was controlled to give a blowing parameter variation of up to 2.9. Data reduction techniques are given for camera calibration, rig temperature reflection correction, and deriving surface temperatures from video images. Results are presented in terms of overall and film cooling effectiveness distributions. A one-dimensional analysis of a unit film cooling hole was performed to generate film temperature.

Reilly, R. S.↗

Unsteady, Cooled Turbine Simulation Using a PC-Linux Analysis System

The fist stage of the high-pressure turbine (HPT) of the GE90 engine was simulated with a three-dimensional unsteady Navier-Sokes solver, MSU Turbo, which uses source terms to simulate the cooling flows. In addition to the solver, its pre-processor, GUMBO, and a post-processing and visualization tool, Turbomachinery Visual3 (TV3) were run in a Linux environment to carry out the simulation and analysis. The solver was run both with and without cooling. The introduction of cooling flow on the blade surfaces, case, and hub and its effects on both rotor-vane interaction as well the effects on the blades themselves were the principle motivations for this study. The studies of the cooling flow show the large amount of unsteadiness in the turbine and the corresponding hot streak migration phenomenon. This research on the GE90 turbomachinery has also led to a procedure for running unsteady, cooled turbine analysis on commodity PC's running the Linux operating system.

List, Michael G.↗

Cryogen-Free Ultra-Low Temperature Cooling using a Continuous ADR

The development of a continuous adiabatic demagnetization refrigerator (CADR) has progressed to the point where we have demonstrated a 4-stage system that provides continuous cooling at 50 mK and below, while rejecting heat to a 4.2 K helium bath. Since temperature control and cycling of the ADR is fully automated, the system is simple to operate and stable. Temperature fluctuations of the cold tip are typically less than 10 microKelvin rms (at 100 mK). The ADR s cooling power of 2 1 microwatts at 100 mK is comparable to that of small dilution refrigerators, but because its efficiency is so much higher (50% of Carnot), the peak heat rejection rate is less than 10 mW. This is significant in allowing the ADR to be cooled by relatively low-power cryocoolers. In addition to commercial pulse-tube and Gifford McMahon (GM) coolers, this potentially includes small GM systems that run on 120 V power and do not need water cooling. The present focus is to design and fabricate a small dewar to house the CADR and a cryocooler, in anticipation of making a cryogen-free, low cost CADR commercially available. Performance of the prototype CADR and the complete system will be discussed.

Shirron, Peter↗

Capella: Structure and Abundances

This grant covers the analysis of ASCA spectra of the cool star binary system Capella. This project has also required the analysis of simultaneous EUVE data. The ASCA spectrum of Capella could not be fit with standard models; by imposing models based on strong lines observed with EUVE, a problem wavelength region was identified. Correcting the problem required calculations of atomic collision strengths of higher principal quantum number than had ever been calculated, resulting in a paper in process by Liedahl and Brickhouse. With these new models applied to the ASCA spectrum, better fits were obtained. While solar abundance ratios are generally consistent with the ASCA data, the ratio of Ne/Fe is three to four times lower than solar photospheric values. Whether there is a general First Ionization Potential (FIP) effect or a specific neon anomaly cannot be determined from these data. Detailed discussion has been provided to NASA in the most recent annual report (1997). Two poster presentations have been made regarding modeling requirements. A substantial paper is in the final revision form, following review by six co-authors. The results of this work have wide implications, since the newly calculated emission lines almost certainly contribute to other problems in fitting not only other stellar spectra, but also composite supernova remnants, galaxies, and cooling flow clusters of galaxies. Furthermore, Liedahl and Brickhouse have identified other species for which lines of a similar nature (high principal quantum number) will contribute significant flux. For moderate resolution X-ray spectra, lines left out of the models in relatively isolated bands, will be attributed to continuum flux by spectral fitting engines, causing errors in line-to-continuum ratios. Thus addressing the general theoretical problem is of crucial importance.

Brickhouse, Nancy S.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗