Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Efficient Scalable Tomography of Many-Qubit Quantum Processors

Quantum computing has the potential to realize powerful and revolutionary applications. A quantum computer can, in theory, solve certain problems exponentially faster than its classical counterparts. The current state of the art devices, however, are too small and noisy to practically realize this goal. An important tool for the advancement of quantum hardware, called model-based characterization, seeks to learn what types of noise are exhibited in a quantum processor. This technique, however, is notoriously difficult to scale up to even modest numbers of qubit, and has been limited to just 2 qubits until now. In this report, we present a novel method for performing model-based characterization, or tomography, on a many-qubit quantum processor. We consider up to 10 qubits, but the technique is expected to scale to even larger systems.

97 MATHEMATICS AND COMPUTING↗

Quantum process tomography of a Mølmer-Sørensen gate via a global beam

Here, we present a framework for quantum process tomography of two-ion interactions that leverages modulations of the trapping potential and composite pulses from a global laser beam to achieve individual-ion addressing. Tomographic analysis of identity and delay processes reveals dominant error contributions from laser decoherence and slow qubit frequency drift during the tomography experiment. We use this framework on two co-trapped 40 Ca + ions to analyze both an optimized and an overpowered Mølmer–Sørensen gate and to compare the results of this analysis to a less informative Bell-state tomography measurement and to predictions based on a simplified noise model. These results show that the technique is effective for the characterization of two-ion quantum processes and for the extraction of meaningful information about the errors present in the system. The experimental convenience of this method will allow for more widespread use of process tomography for characterizing entangling gates in trapped-ion systems.

quantum computing↗

A state-of-the-art review of experimental and computational studies of granular materials: Properties, advances, challenges, and future directions

Modeling of heterogeneous materials and media is a problem of fundamental importance to a wide class of phenomena and systems, ranging from condensed matter physics, soft materials, and composite media to porous media, biological systems, geosystems, ceramic engineering, pharmaceutical science and even in space discoveries. Among the most important materials are granular systems, which have received intense interest from the engineering, physics, and mathematics communities. In this review paper, the recent developments and new advances in experimental, and computational methods on a variety of scales and physics that extend understanding to a wide range of materials and phenomena are reviewed. Experimental advances include computed neutron and nanometer-scale tomography, magnetic resonance imaging, refractive index matching, digital image correlation, acoustic emission analysis, and the most recent 4D techniques. Furthermore, a tremendous shift has occurred from the continuum scale to micro-scale and developing multiscale approaches. As such, various computational methods, including, constitutive modeling, discrete modeling, and multiscale approaches, have been developed. In conclusion, aside from all these evolutions, more complicated modeling called coupled, or multiphysics, systems representing a simultaneous presence of heat, fluid, chemical variation, and mechanical effect are also explored.

36 MATERIALS SCIENCE↗

Variational approach to quantum state tomography based on maximal entropy formalism

Quantum state tomography is an integral part of quantum computation and offers the starting point for the validation of various quantum devices. One of the central tasks in the field of state tomography is to reconstruct, with high fidelity, the quantum states of a quantum system. From an experiment on a real quantum device, one can obtain the mean measurement values of different operators. With such data as input, in this report we employ the maximal entropy formalism to construct the least biased mixed quantum state that is consistent with the given set of expectation values. Even though, in principle, the reported formalism is quite general and should work for an arbitrary set of observables, in practice we shall demonstrate the efficacy of the algorithm on an informationally complete (IC) set of Hermitian operators. Such a set possesses the advantage of uniquely specifying a single quantum state from which the experimental measurements have been sampled and hence renders the rare opportunity not only to construct a least-biased quantum state but even replicate the exact state prepared experimentally within a preset tolerance. Here, the primary workhorse of the algorithm is reconstructing an energy function which we designate as the effective Hamiltonian of the system, and parameterizing it with Lagrange multipliers, according to the formalism of maximal entropy. These parameters are thereafter optimized variationally so that the reconstructed quantum state of the system converges to the true quantum state within an error threshold. To this end, we employ a parameterized quantum circuit and a hybrid quantum-classical variational algorithm to obtain such a target state, making our recipe easily implementable on a near-term quantum device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Lowering tomography costs in quantum simulation with a symmetry projected operator basis

Measurement in quantum simulations provides a means for extracting meaningful information from a complex quantum state, and for quantum computing, reducing the complexity of measurement will be vital for near-term applications. For most quantum simulations, the targeted state will obey several symmetries inherent to the system Hamiltonian. Here, we obtain an alternative symmetry projected basis of measurement that reduces the number of measurements needed by a constant factor. Our scheme can be implemented at no additional cost on a quantum computer, can be implemented under various measurement or tomography schemes, and is reasonably resilient under noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GLAD-M35: a joint P and S global tomographic model with uncertainty quantification

We present our third and final generation joint P and S global adjoint tomography (GLAD) model, GLAD-M35, and quantify its uncertainty based on a low-rank approximation of the inverse Hessian. Starting from our second-generation model, GLAD-M25, we added 680 new earthquakes to the database for a total of 2160 events. New P-wave categories are included to compensate for the imbalance between P- and S-wave measurements, and we enhanced the window selection algorithm to include more major-arc phases, providing better constraints on the structure of the deep mantle and more than doubling the number of measurement windows to 40 million. Two stages of a Broyden–Fletcher–Goldfarb–Shanno (BFGS) quasi-Newton inversion were performed, each comprising five iterations. With this BFGS update history, we determine the model’s standard deviation and resolution length through randomized singular value decomposition.

58 GEOSCIENCES↗

Development of Automated Atom Probe Tomography capability to study the influence of applied voltage and laser power on the final apparent composition of the analyzed specimen

This study presents the development and implementation of an autonomous Bayesian optimization (BO) framework for controlling and optimizing experimental parameters in Atom Probe Tomography (APT). Using commercial silicon needle samples as a benchmark system, we demonstrate that BO can efficiently navigate the complex parameter space of voltage and laser power to achieve target charge state ratios (specifically Si + /(Si + +Si 2+ )) with minimal experimental evaluations. Our implementation integrates Gaussian Process modeling with the CAMECA atom probe control framework, enabling autonomous adjustment of experimental conditions in real-time. Results show that the algorithm successfully converges to target ratios under different scenarios: maintaining a reference ratio, increasing the ratio (favoring Si 1+ ), and decreasing the ratio (favoring Si 2+ ). The system adapts to specimen evolution during analysis, compensating for changes in apex geometry while maintaining optimization targets. This work establishes a proof of concept for AI-driven optimization in APT, addressing the traditional challenges of manual parameter tuning and paving the way for applications to more complex materials where compositional accuracy is critical.

36 MATERIALS SCIENCE↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Elucidating the Role of Electric Fields in Fe Oxidation via an Environmental Atom Probe

We quantify the effects of intensely applied electric fields on the Fe oxidation mechanism. The specimen are pristine Fe single crystals exposing a variety of surface structures identified by field ion microscopy. These crystals are simultaneously exposed to low pressures of pure oxygen gas, on the order of 10 −7 mbar, while applying intense electric fields on their surface of several tens of volts per nanometer. The local composition of the different surface structures is probed directly and in real time using an Environmental Atom Probe and successfully compared with first principles-based models. We found that rough Fe{244} and Fe{112} facets are more reactive toward oxygen than compact Fe{024} and Fe{011} facets. Results demonstrate that the influence of an electric field on the oxidation kinetics depends on the timescales that are involved as the system evolves toward equilibrium. The initial oxidation kinetics show that strong increases in electric fields facilitate the formation of an oxide. However, as one approaches equilibrium, high field values mitigate this formation. Ultimately, this study elucidates how high externally applied electric fields can be used to dynamically exploit reaction dynamics at the nanoscale towards desired products in a catalytic reaction at mild reaction conditions.

09 BIOMASS FUELS↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pre-conditioned BFGS-based uncertainty quantification in elastic full-waveform inversion

SUMMARY Full-waveform inversion has become an essential technique for mapping geophysical subsurface structures. However, proper uncertainty quantification is often lacking in current applications. In theory, uncertainty quantification is related to the inverse Hessian (or the posterior covariance matrix). Even for common geophysical inverse problems its calculation is beyond the computational and storage capacities of the largest high-performance computing systems. In this study, we amend the Broyden–Fletcher–Goldfarb–Shanno (BFGS) algorithm to perform uncertainty quantification for large-scale applications. For seismic inverse problems, the limited-memory BFGS (L-BFGS) method prevails as the most efficient quasi-Newton method. We aim to augment it further to obtain an approximate inverse Hessian for uncertainty quantification in FWI. To facilitate retrieval of the inverse Hessian, we combine BFGS (essentially a full-history L-BFGS) with randomized singular value decomposition to determine a low-rank approximation of the inverse Hessian. Setting the rank number equal to the number of iterations makes this solution efficient and memory-affordable even for large-scale problems. Furthermore, based on the Gauss–Newton method, we formulate different initial, diagonal Hessian matrices as pre-conditioners for the inverse scheme and compare their performances in elastic FWI applications. We highlight our approach with the elastic Marmousi benchmark model, demonstrating the applicability of pre-conditioned BFGS for large-scale FWI and uncertainty quantification.

58 GEOSCIENCES↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗