Effect of particle size on thermodynamics and lithium ion transport in electrodes made of Ti 2 Nb 2 O 9 microparticles or nanoparticles

This study compares the charging mechanisms, thermodynamics, lithium ion transport, and operando isothermal calorimetry in lithium-ion battery electrodes made of Ti 2 Nb 2 O 9 microparticles or nanoparticles synthesized by solid-state or sol-gel methods, respectively. First, electrochemical testing showed that electrodes made of Ti 2 Nb 2 O 9 nanoparticles exhibited larger specific capacity, smaller polarization, and better capacity retention at large currents than those made of Ti 2 Nb 2 O 9 microparticles. Furthermore, potentiometric entropy measurements revealed that electrodes made of either Ti 2 Nb 2 O 9 microparticles or nanoparticles showed similar thermodynamics behavior governed by lithium intercalation in solid solution, as confirmed by in situ XRD measurements. However, electrodes made of Ti 2 Nb 2 O 9 nanoparticles featured smaller overpotential and faster lithium ion transport than those made of Ti 2 Nb 2 O 9 microparticles. In fact, operando isothermal calorimetry revealed smaller instantaneous and time-averaged irreversible heat generation rates at electrodes made of Ti 2 Nb 2 O 9 nanoparticles, highlighting their smaller resistive losses and larger electrical conductivity. Finally, the measured total heat generation over a charging/discharging cycle matched the measured net electrical energy loss. Overall, Ti 2 Nb 2 O 9 nanoparticles synthesized by the novel sol-gel method displayed excellent cycling performance and reduced heat generation as a fast-charging lithium-ion battery anode material. These features present major advantages for actual battery systems including larger energy and power densities, simpler thermal management, and enhanced safety.

25 ENERGY STORAGE↗

A finite micro-rotation material point method for micropolar solid and fluid dynamics with three-dimensional evolving contacts and free surfaces

This paper introduces an explicit material point method designed specifically for simulating the micropolar continuum dynamics in the finite deformation and finite microrotation regime. The material point method enables us to simulate large deformation problems while circumventing the potential mesh distortion without remeshing. To eliminate rotational motion damping and loss of angular momentum during the projection, we introduce the mapping for microinertia and angular momentum between particles and grids through the affine particle-in-cell approach. The microrotation and the curvature at each particle are updated through zero-order forward integration of the microgyration and its spatial gradient. We show that the microinertia and the angular momentum are conserved during the projections between particles and grids in our formulation. We verify the formulation and implementation by comparing with the analytical dispersion relation of micropolar waves under the small strain and small microrotation, as well as the analytical soliton solution for solids undergoing large deformation and large microrotation. Additionally we also demonstrate the capacity of the proposed computational framework to handle a wide spectrum of simulations that exhibit size effects in the geometrical nonlinear regime through three representative numerical examples, i.e., a cantilever beam torsion problem, a fragment-impact penetration problem, and a micropolar fluid discharging problem.

42 ENGINEERING↗

Distributed Trajectory Flexibility Preservation for Traffic Complexity Mitigation

The growing demand for air travel is increasing the need for mitigation of air traffic congestion and complexity problems, which are already at high levels. At the same time new information and automation technologies are enabling the distribution of tasks and decisions from the service providers to the users of the air traffic system, with potential capacity and cost benefits. This distribution of tasks and decisions raises the concern that independent user actions will decrease the predictability and increase the complexity of the traffic system, hence inhibiting and possibly reversing any potential benefits. In answer to this concern, the authors propose the introduction of decision-making metrics for preserving user trajectory flexibility. The hypothesis is that such metrics will make user actions naturally mitigate traffic complexity. In this paper, the impact of using these metrics on traffic complexity is investigated. The scenarios analyzed include aircraft in en route airspace with each aircraft meeting a required time of arrival in a one-hour time horizon while mitigating the risk of loss of separation with the other aircraft, thus preserving its trajectory flexibility. The experiments showed promising results in that the individual trajectory flexibility preservation induced self-separation and self-organization effects in the overall traffic situation. The effects were quantified using traffic complexity metrics based on Lyapunov exponents and traffic proximity.

Idris, Husni↗

Analysis of Trajectory Flexibility Preservation Impact on Traffic Complexity

The growing demand for air travel is increasing the need for mitigation of air traffic congestion and complexity problems, which are already at high levels. At the same time new information and automation technologies are enabling the distribution of tasks and decisions from the service providers to the users of the air traffic system, with potential capacity and cost benefits. This distribution of tasks and decisions raises the concern that independent user actions will decrease the predictability and increase the complexity of the traffic system, hence inhibiting and possibly reversing any potential benefits. In answer to this concern, the authors proposed the introduction of decision-making metrics for preserving user trajectory flexibility. The hypothesis is that such metrics will make user actions naturally mitigate traffic complexity. In this paper, the impact of using these metrics on traffic complexity is investigated. The scenarios analyzed include aircraft in en route airspace with each aircraft meeting a required time of arrival in a one-hour time horizon while mitigating the risk of loss of separation with the other aircraft, thus preserving its trajectory flexibility. The experiments showed promising results in that the individual trajectory flexibility preservation induced self-separation and self-organization effects in the overall traffic situation. The effects were quantified using traffic complexity metrics, namely dynamic density indicators, which indicated that using the flexibility metrics reduced aircraft density and the potential of loss of separation.

Idris, Husni↗

Stabilizing Reversible Oxygen Redox Chemistry in Layered Oxides for Sodium‐Ion Batteries

Abstract Triggering oxygen‐related activity is demonstrated as a promising strategy to effectively boost energy density of layered cathodes for sodium‐ion batteries. However, irreversible lattice oxygen loss will induce detrimental structure distortion, resulting in voltage decay and cycle degradation. Herein, a layered structure P2‐type Na 0.66 Li 0.22 Ru 0.78 O 2 cathode is designed, delivering reversible oxygen‐related and Ru‐based redox chemistry simultaneously. Benefiting from the combination of strong Ru 4d‐O 2p covalency and stable Li location within the transition metal layer, reversible anionic/cationic redox chemistry is achieved successfully, which is proved by systematic bulk/surface analysis by in/ex situ spectroscopy (operando Raman and hard X‐ray absorption spectroscopy, etc.). Moreover, the robust structure and reversible phase transition evolution revealed by operando X‐ray diffraction further establish a high degree reversible (de)intercalation processes (≈150 mAh g −1 , reversible capacity) and long‐term cycling (average capacity drop of 0.018%, 500 cycles).

Cao, Xin↗

Degradation Diagnostics from the Subsurface of Lithium-Ion Battery Electrodes

Despite the long-established rocking-chair theory of lithium-ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe + PFIB)-based characterization technique to probe the cross-sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in-depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Here, through the quantitative analysis of the transition-metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB-based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high-sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity-fade observed in most LIBs.

25 ENERGY STORAGE↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Role of Cations in the Cation-Driven Assembly Process and their Effect on the Charge Storage Properties of Bilayered Vanadium Oxide and Reduced Graphene Oxide Heterostructures in Alkali Ion Systems

Exfoliated δ-Li x V 2 O 5 ·nH 2 O (ex-LVO) and reduced graphene oxide (rGO) heterostructures were constructed using different assembling cations (i.e., Li⁺, Na⁺, and K⁺ ions). The ex-LVO and rGO nanoflakes were stacked together using a concentrated chloride solution of each assembling cation and vacuum annealed at 200 °C to form three distinct two-dimensional (2D) layered architectures. X-ray diffraction and thermogravimetric analysis confirmed that the assembling ions can control the interlayer spacing of the bilayered vanadium oxide (BVO) phase as well as impact the crystallographic water content, which in turn affects the electrochemical performance. Scanning electron microscopy, scanning transmission electron microscopy (STEM), electron energy-loss spectroscopy (EELS), and X-ray photoelectron spectroscopy confirmed that a 2D heterointerface formed between LVO and rGO and that the cations used to assemble the heterostructure are trapped in the interlayer BVO region. High-resolution STEM imaging also showed the rGO dispersion throughout the LVO layers. Moreover, STEM-EELS identified a V 2 O 3 phase that forms along the rGO interface and can stabilize the materials during cycling. A charge storage mechanism analysis, combined with the galvanostatic intermittent titration technique, found that increased interlayer spacings of the BVO phase and using the assembling cations to define intercalation sites for identical charge-carrying ions lead to improved ion diffusion and increased capacities during cycling. Therefore, the Li⁺ and Na⁺ ion assembled heterostructures showed improved charge-carrying ion diffusion and charge storage capacities in each of their respective charge storage systems (i.e., Li-ion and Na-ion half-cells). In total, the cation used for heterostructure assembly can modify the final material structure and tailor the ion diffusion and charge storage capacity to tune its properties for the desired electrochemical system using a variety of 2D materials.

25 ENERGY STORAGE↗

Mixed Cationic and Anionic Redox in Ni and Co Free Chalcogen-Based Cathode Chemistry for Li-Ion Batteries

Mixed cationic and anionic redox cathode chemistry is emerging as conventional cationic-redox of transition metal based layered oxides are reaching their theoretical capacity limit. However, these anionic redox in transition metal oxide-based cathodes attained by taking excess lithium has resulted in stability issues due to weak metal - oxygen ligand covalency. Here, we present an alternative approach of improving metal - ligand covalency by introducing less electronegative chalcogen ligand (sulfur) in the cathode structural framework where the metal dband penetration into ligand p-band thereby utilizing reversible mixed anionic and cationic redox chemistry. Through this design strategy, we report possibility of developing a new family of layered cathode materials when partially filled d orbital redox couples like Fe 2+/3+ are introduced in the Li-ion conducting phase (Li 2 SnS 3 ). Further, the electron energy loss spectroscopy (EELS) and X-ray absorption near-edge structure (XANES) analysis are used to qualitatively identify the charge contributors at the metal and ligand sites during Li + extraction. The detailed high-resolution transmission electron microscopy (HR-TEM) and high annular dark field-scanning transmission electron microscopy (HAADF-STEM) investigation reveal the multi redox induced structural modifications and its surface amorphization with nanopore formation during cycling. Findings from this study will shed light on designing Ni and Co free chalcogen cathodes and various functional materials in the chalcogen based dual anionic and cationic redox cathode avenue.

25 ENERGY STORAGE↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced space propulsion thruster research

Experiments showed that stray magnetic fields can adversely affect the capacity of a hollow cathode neutralizer to couple to an ion beam. Magnetic field strength at the neutralizer cathode orifice is a crucial factor influencing the coupling voltage. The effects of electrostatic accelerator grid aperture diameters on the ion current extraction capabilities were examined experimentally to describe the divergence, deflection, and current extraction capabilities of grids with the screen and accelerator apertures displaced relative to one another. Experiments performed in orificed, mercury hollow cathodes support the model of field enhanced thermionic electron mission from cathode inserts. Tests supported the validity of a thermal model of the cathode insert. A theoretical justification of a Saha equation model relating cathode plasma properties is presented. Experiments suggest that ion loss rates to discharge chamber walls can be controlled. A series of new discharge chamber magnetic field configurations were generated in the flexible magnetic field thruster and their effect on performance was examined. A technique used in the thruster to measure ion currents to discharge chamber walls is described. Using these ion currents the fraction of ions produced that are extracted from the discharge chamber and the energy cost of plasma ions are computed.

Wilbur, P. J.↗

Halting Oxygen Evolution to Achieve Long Cycle Life in Sodium Layered Cathodes

Oxygen redox chemistries at high voltage have materialized as a revolutionary paradigm for cathodes with high-energy density; however, they are plagued by the challenges of labile oxygen loss and rapid degradations upon cycling, even after concerted endeavors from the research community. Here we propose a multi-concentration stratagem propelled by entropy reinforcement to enhance the electronic structure disorder (ESD) at high desodiation states for impeding undesired oxygen mobility and ensuring controlled oxygen activity, elucidated by density functional theory calculations. The increased disorder strengthens the reversible electrochemistry of lattice oxygen redox, leading to effectively suppressed P−O structural evolution and highly stable localized TMO 6 octahedral environments, as demonstrated by soft/hard X-ray absorption spectroscopy. Furthermore, through a comparative analysis of sodium-layered cathodes with different configuration entropy, we reveal that a high-entropy state induced by cationic disordering has the capacity to perturb cationic redox boundaries, significantly restraining the formation of detrimental O′3 phases. As a consequence, the high-voltage cycling stability has been greatly upgraded, up to 4.4 V versus Na + /Na, with an impressive 90.1 % capacity retention at 1 C over 100 cycles and 76.1 % capacity retention at 2 C over 300 cycles. In conclusion, the resilient oxygen redox, enabled through the control of ESD, broadens the horizons for entropy engineering and lays the foundation for advancements in high-energy, long-cycling, and safe batteries.

25 ENERGY STORAGE↗

Impacts of feeding three strains of microalgae alone or in combination on growth performance, protein metabolism, and meat quality of broiler chickens

Variations in nutrient compositions, especially amino acid (AA) profiles, among microalgal species may enable a superior feeding outcome from a combined than singular supplementation in poultry diets. Therefore, a feeding trial was conducted to compare the effects of three strains of microalgal biomass supplemented alone or in combination to replace 5 % (starter) and 10 % (grower) soybean meal (on weight-to-weight basis) on growth performance, protein metabolism, and meat quality of broiler chickens. Day-old Cornish Cross male chicks (total = 180) were divided into 5 groups (6 cages/treatment, 6 birds/cage) and fed a corn-soybean meal basal diet (BD), BD + H117 (Chlorella sp., H117), BD + C985 (Tetraselmis sp., C985), BD + Nannochloropsis oceanica (NO), and BD + H117 + C985 + NO (Combination). Feeding any of the microalgae diets did not alter growth performance nor meat quality including texture, pH, color, and water holding capacity of breast and thigh meats. However, the breast weight percentages were decreased (P < 0.05) by feeding the C985, NO, and Combination diets. Compared with the BD, the 4 microalgal diets led to higher (P < 0.05) plasma uric acid and protein concentrations at weeks 3 and (or) 6. The mRNA levels of MAFbx, MURF1, FOXO1, and calpastatin in the breast and thigh muscles were altered by the microalgal diets but not those of genes associated with other quality traits. In conclusion, replacing 5 % or 10 % soybean meal with three sources of microalgae in broiler diets decreased breast weights percentage but not absolute weight. Furthermore, feeding chickens with the combination of three microalgae did not restore the breast loss and induced different expressions of genes related to muscle hypertrophy or atrophy.

59 BASIC BIOLOGICAL SCIENCES↗

Seamless Hybrid-integrated Interconnect NEtwork (SHINE)

Large-scale date centers are becoming increasingly limited by the capacity of interconnects due to the rapid increasing power consumption and bandwidth demands driven by the rigorous down scaling of CMOS critical dimensions in according with the Moore’s Law. As a result of the continuing bandwidth scaling, optical interconnects based on parallel optics, where data are simultaneously transmitted along more than one lane, have becoming a preferred interconnected solution over copper cables. To building an efficient optical interconnect system, optical coupling between different elements, such as optical fibers, photonics chips, is a critical step, which is challenging due to the mode mismatch of varies optical ports. In this project, we proposed and demonstrated an optical interfacing scheme, which provided a light coupling approach with low energy loss, broadband operation, high alignment tolerance and compatible with scalable fabrication and testing. Here, the mode transformation is achieved by a total internal reflection from a chip integrated microscale freefrom surface. Due to the enormous light wavefront manipulating ability associated with the gigantic design space, the freeform couplers platform is universally applicable to a wide range of optical coupling scenarios, such as the interfacing between a waveguide to a fiber, another waveguide, surface normal device, or free space.

42 ENGINEERING↗

Opposed Jet Burner Extinction Limits: Simple Mixed Hydrocarbon Scramjet Fuels vs Air

Opposed Jet Burner tools have been used extensively by the authors to measure Flame Strength (FS) of laminar non-premixed H2 air and simple hydrocarbon (HC) air counterflow diffusion flames at 1-atm. FS represents a strain-induced extinction limit based on air jet velocity. This paper follows AIAA-2006-5223, and provides new HC air FSs for global testing of chemical kinetics, and for characterizing idealized flameholding potentials during early scramjet-like combustion. Previous FS data included six HCs, pure and N2-diluted; and three HC-diluted H2 fuels, where FS decayed very nonlinearly as HC was added to H2, due to H-atom scavenging. This study presents FSs on mixtures of (candidate surrogate) HCs, some with very high FS ethylene. Included are four binary gaseous systems at 300 K, and a hot ternary system at approx. 600 K. The binaries are methane + ethylene, ethane + ethylene, methane + ethane, and methane + propylene. The first three also form two ternary systems. The hot ternary includes both 10.8 and 21.3 mole % vaporized n-heptane and full ranges of methane + ethylene. Normalized FS data provide accurate means of (1) validating, globally, chemical kinetics for extinction of non-premixed flames, and (2) estimating (scaling by HC) the loss of incipient flameholding in scramjet combustors. The n-heptane is part of a proposed baseline simulant (10 mole % with 30% methane + 60% ethylene) that mimics the ignition of endothermically cracked JP-7 like kerosene fuel, as suggested by Colket and Spadaccini in 2001 in their shock tube Scramjet Fuels Autoignition Study. Presently, we use FS to gauge idealized flameholding, and define HC surrogates. First, FS was characterized for hot nheptane + methane + ethylene; then a hot 36 mole % methane + 64% ethylene surrogate was defined that mimics FS of the baseline simulant system. A similar hot ethane + ethylene surrogate can also be defined, but it has lower vapor pressure at 300 K, and thus exhibits reduced gaseous capacity. The new FS results refine our earlier idealized reactivity scale that shows wide ranging (50 x) diameter-normalized FSs for various HCs. These range from JP-10 and methane to H2 air, which produces an exceptionally strong flame that agrees within approx. 1% of recent 2-D numerically simulations. Finally, we continue advocating the FS approach as more direct and fundamental, for assessing idealized scramjet flameholding potentials, than measurements of unstrained laminar burning velocity or blowout in a Perfectly Stirred Reactor.

Pellett, Gerald L.↗

Multi-modal characterization methods of solid-electrolyte interphase in silicon-graphite composite electrodes

Composite silicon-graphite (Si-Gr) anodes can improve battery energy density, due to Si's high gravimetric capacity, while mitigating mechanical degradation of the anode and solid-electrolyte interphase (SEI) caused by Si volumetric expansion. Optimizing these anodes is challenging, in part due to difficulty characterizing the SEI structure and composition. In this work, we present multi-modal characterization of the SEI on composite Si-Gr anodes to relate SEI chemical composition and structure to functional properties. Discrepancies in elemental concentrations from X-ray photoelectron spectroscopy, Auger electron spectroscopy, and energy-dispersive X-ray spectroscopy (EDS) are attributed to varying information depth and lateral resolution of the individual probes. However, by combining quantitative composition information with spatially resolved element mapping from scanning transmission electron microscopy, EDS, and electron energy loss spectroscopy, a holistic picture of the SEI emerges. We observe the bilayer SEI structure and a direct correlation between elemental Li and F, suggesting that most Li in the SEI exists as lithium fluoride (LiF). Further, LiF concentration is directly proportional to the maximum SEI resistivity, as determined by scanning spreading resistance microscopy. Lastly, there is an inverse relationship between lithium carbonate and LiF concentration in the SEI, providing insight into the detailed chemistry of SEI formation and evolution.

25 ENERGY STORAGE↗

An Analytical Investigation of the Heat Losses from a U.S. Navy K-Type Airship

The heat losses from the envelope surface of a U.S. Navy K-type airship are evaluated to determine if the use of heat is a feasible means of preventing ice and snow accumulations on lighter-than-air craft during flight and when moored uncovered. Consideration is given to heat losses in clear air (no liquid water present in the atmosphere) and in probable conditions of icing and snow. The results of the analysis indicate that the amount of heat required in flight to raise the surface temperature of the entire envelope to the extent considered adequate for ice protection, based on experience with tests of heavier-than-air craft, is very large. Existing types of heating equipment which could be used to supply this quantity of heat would probably be too bulky and heavy to provide a practical flight installation. The heat requirements to provide protection for the nose and stern regions in assumed mild to moderate icing conditions appear to be within the range of the capacity of current types of heating equipment suitable for flight use. The amount of heat necessary to prevent snow accumulations on the upper surface of the airship envelope when moored uncovered under all conditions appear to be excessive for the heating equipment presently available for flight use, but could possibly be achieved with auxiliary ground heating equipment.

Hillendahl, Wesley H.↗

Role of skin blood flow and sweating rate in exercise thermoregulation after bed rest

Two potential mechanisms, reduced skin blood flow (SBF) and sweating rate (SR), may be responsible for elevated intestinal temperature (T(in)) during exercise after bed rest and spaceflight. Seven men underwent 13 days of 6 degrees head-down bed rest. Pre- and post-bed rest, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-bed rest supine peak exercise capacity) in a thermoneutral room. After bed rest, T(in) was elevated at rest (+0.31 +/- 0.12 degrees C) and at the end of exercise (+0.33 +/- 0.07 degrees C). Percent increase in SBF during exercise was less after bed rest (211 +/- 53 vs. 96 +/- 31%; P < or = 0.05), SBF/T(in) threshold was greater (37.09 +/- 0.16 vs. 37.33 +/- 0.13 degrees C; P < or = 0.05), and slope of SBF/T(in) tended to be reduced (536 +/- 184 vs. 201 +/- 46%/ degrees C; P = 0.08). SR/T(in) threshold was delayed (37.06 +/- 0.11 vs. 37.34 +/- 0.06 degrees C; P < or = 0.05), but the slope of SR/T(in) (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg x min-1 x cm-2 x degrees C-1) and total sweat loss (0.42 +/- 0.06 vs. 0.44 +/- 0.08 kg) were not changed. The higher resting and exercise T(in) and delayed onset of SBF and SR suggest a centrally mediated elevation in the thermoregulatory set point during bed rest exposure.