Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Theoretical derivation and calibration technique of a hemispherical-tipped, five-hole probe

A technique is presented for the calibration of a hemispherical tipped 0.125 inch diameter 5-hole probe. The derivation of equations from the potential flow over a sphere relating the flow angle and velocity to pressure differentials measured by the probe is presented. The technique for acquiring the calibration data and the technique used to calculate the calibration coefficients are presented. The accuracy of the probe in both the uniform calibration flow field and the nonuniform flow field over a 75 degree swept delta wing is discussed.

Kjelgaard, Scott O.↗

In-flight radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations (pre- and post-season of flight) for a uniform highly reflecting natural dry lake target. For one spectrometer (C), the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. This positive result validates the field and laboratory calibration technique. Results for the other spectrometers (A, B and D) were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.↗

Calibration of the visible and near-infrared channels of the NOAA-9 AVHRR using high-altitude aircraft measurements from August 1985 and October 1986

Visible and near infrared wavelength sensors mounted on operational satellites now in use do not have onboard absolute calibration devices. One means of establishing an in-orbit calibration for a satellite sensor is to make simultaneous measurement of a bright, relatively uniform scene along the satellite view vector from a calibrated instrument on board a high altitude aircraft. Herein, aircraft data were recorded over White Sands, New Mexico at satellite overpass time. Comparison of the coincident aircraft and orbiting satellite data for the visible and near infrared wavelength channels of the NOAA-9 Advanced Very High Resolution Radiometer shows that the calibration of the visible channel was unchanged from prelaunch values, but that the near infrared channel has degraded 6 percent by Aug. 1985. By Oct. 1986 the visible channel had degraded 13 percent and the near infrared channel had degraded 19 percent.

Smith, Gilbert R.↗

Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

Jelinsky, P.↗

Preliminary results from a subsonic high angle-of-attack flush airdata sensing (HI-FADS) system: Design, calibration, and flight test evaluation

A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research flight vehicle. The system is a matrix of 25 pressure orifices in concentric circles on the nose of the vehicle. The orifices determine angles of attack and sideslip, Mach number, and pressure altitude. Pressure was transmitted from the orifices to an electronically scanned pressure module by lines of pneumatic tubing. The HI-FADS system was calibrated and demonstrated using dutch roll flight maneuvers covering large Mach, angle-of-attack, and sideslip ranges. Reference airdata for system calibration were generated by a minimum variance estimation technique blending measurements from two wingtip airdata booms with inertial velocities, aircraft angular rates and attitudes, precision radar tracking, and meteorological analyses. The pressure orifice calibration was based on identifying empirical adjustments to modified Newtonian flow on a hemisphere. Calibration results are presented. Flight test results used all 25 orifices or used a subset of 9 orifices. Under moderate maneuvering conditions, the HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz. Aerodynamic lags in the aircraft flow field caused some performance degradation during heavy maneuvering.

Whitmore, Stephen A.↗

Satellite altimeter calibration techniques

This paper examines calibration techniques which can most effectively satisfy the requirements of future satellites carrying high-accuracy radar altimeters, such as the ESA ERS-1 and the NASA/CNES Topex/Poseidon satellites scheduled for launch during the next five years. The calibration accuracies and the advantages and disadvantages of the four currently proposed calibration techniques for over-water calibration are discussed: (1) a tide gauge on a tower at-sea and a nearby laser, (2) a laser and a tide gauge on an island with an offshore satellite pass and a geoid tie between the satellite ground track and the laser, (3) a tide gauge on a tower at-sea with satellite positioning from multiple lasers and a GPS, and (4) a laser and a tide gauge on a tower at-sea. Error budgets for these techniques, developed on the basis of state-of-the-art tracking systems, were found to have one sigma height uncertainties in the 2.8 to 4.9 cm range.

Kolenkiewicz, R.↗

Nonlinearity corrections in calibration of advanced very high resolution radiometer infrared channels

The IR channels of the AVHRR are calibrated in-flight with data acquired when the AVHRR views space and a warm target on board. This determines the two coefficients of a linear calibration equation. However, in its 11- and 12-micron channels the response of the AVHRR is nonlinear. If not accounted for, the nonlinearity could cause errors as large as 2 C in inferred scene temperatures. Therefore NESDIS computes corrections to the brightness temperatures inferred from the linear calibration. This paper describes how the corrections have been calculated at NESDIS since March 1986 and presents the corrections for the AVHRRs on the NOAA 9, 10, and 11 satellites. The corrections are calculated from results of the prelaunch calibration.

Weinreb, Michael P.↗

Radiance calibration of spherical integrators

Techniques for improving the knowledge of the radiance of large area spherical and hemispherical integrating energy sources have been investigated. Such sources are used to calibrate numerous aircraft and spacecraft remote sensing instruments. Comparisons are made between using a standard source based calibration method and a quantum efficient detector (QED) based calibration method. The uncertainty involved in transferring the calibrated values of the point source standard lamp to the extended source is estimated to be 5 to 10 percent. The use of the QED allows an improvement in the uncertainty to 1 to 2 percent for the measurement of absolute radiance from a spherical integrator source.

Mclean, James T.↗

Calibration of polarimetric radar images using only image parameters and trihedral corner reflector responses

A technique that uses the radar return from natural targets and at least one trihedral corner reflector to calibrate compressed polarimetric radar data is described. Calibration for relative amplitude and phase, absolute amplitude, and system crosstalk is addressed. The crosstalk calibration method does not require any external calibration targets. Because compressed data are used, the transmitting and receiving systems as must be modeled as reciprocal. Even though the inferred transmit and receive matrices are not simply related to the physical systems, the true Stokes maxtrix for each pixel can be determined accurately. The method is illustrated by estimating the crosstalk parameters of the NASA/JPL aircraft for different types of terrain and for two frequencies. For a C-band system, the crosstalk is less than -20 dB for all ranges in the images. The crosstalk of the L-band system is a function of range and may be as poor as -10 dB in the near range, leading to a noticeable distortion of the polarization signatures.

Van Zyl, Jakob J.↗

NOAA-11 AVHRR visible and near-IR inflight calibration

An inflight calibration method for NOAA-11 AVHRR visible and near-infrared bands using desert reflectance is discussed. The results show a decrease in sensor systems response of 22 percent and 32 percent for the visible and near-infrared bands, respectively, relative to the published preflight calibration. The relative accuracy of the present calibration to the calibration of NOAA-9, published elsewhere, is + or - 3 percent. The absolute accuracy is around + or - 6 percent. An approximate correction to the Normalized Difference Vegetation Index ratio suggests that an increase of 0.06 is required.

Holben, B. N.↗

Precise frequency calibration using television video carriers

The availability of inexpensive and quick precise frequency calibration methods is limited. VLF and GPS do offer precise calibration. However, antenna placement, cost of equipment, and calibration time place many restrictions on the user. The USNO maintained line-10 television Time of Coincidence (TOC) of station WTTG, channel 5, Washington, DC requires a frequency stable video carrier. This video carrier, 77.24 MHz is controlled by the same cesium beam standard controlling the TOC of line-10. Excellent frequency comparisons against this video carrier have been accomplished at 95 miles (153 km). With stable propagation and a three foot wire antenna, a part in 10(exp 9) can be determined in a few minutes. Inexpensive field equipment with a synthesized 1 kHz offset from the video carrier offers parts in 10(exp 11) calibrations in a few minutes using an oscilloscope as a phase comparator.

Burkhardt, Edward E.↗

Evaluating the effect of accuracy ratios on the percent of calibrations which are out of tolerance

The standard practice in calibration laboratories across the country, including the Measurement Standards and Calibration Laboratory (MSCL) at the Johnson Space Center, is to use accuracy ratios to determine if instruments are in-tolerance rather than computing the actual uncertainty associated with the instruments. In the past, the accepted practice was to use an accuracy ratio of 10:1, but then state of the art advanced to the point where the 10:1 ratio could no longer be maintained, and the ratio was arbitrarily lowered to 4:1. It is now becoming increasingly difficult to maintain the 4:1 accuracy ratio, and in some cases 1:1 is the best that can be achieved. However, the effect of using these small accuracy ratios on the number of mistakes made in classifying instruments as in or out of tolerance is completely unknown. In order to assess the effect of using accuracy ratios in calibration, a simulation program was written to compute the proportion of instruments determined to be out of tolerance which were actually in, denoted by alpha, and the proportion of instruments determined to be in-tolerance which were actually out, denoted by beta. This was done for accuracy ratios of 1:1 and 10:1, for one to five progressive calibrations, under varying standard and instrument conditions. Selected results are presented and explained.

Navard, Sharon E.↗

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

Calibration and operation of a large space-based optical interferometer

The on-orbit calibration of the optics, structure, and control systems of the CSI Focus Mission Interferometer (FMI) is described. The calibration involves the estimation and propagation of both positional and rotational parameters and the propagation of both positional and rotational parameters at the nanometer/nanoradian level. It is shown that, given a nanometer class metrology system to monitor positional changes of critical optical elements, this calibration procedure should enable the FMI to perform 50 picoradian astrometry. The same Kalman filter that implements the initializing calibration of the interferometer baselines and internal pathlengths will also participate in the astrometric measurements of stellar positions.

Laskin, R. A.↗

Earth Radiation Budget Experiment scanner radiometric calibration results

The Earth Radiation Budget Experiment (ERBE) scanning radiometers are producing measurements of the incoming solar, earth/atmosphere-reflected solar, and earth/atmosphere-emitted radiation fields with measurement precisions and absolute accuracies, approaching 1 percent. ERBE uses thermistor bolometers as the detection elements in the narrow-field-of-view scanning radiometers. The scanning radiometers can sense radiation in the shortwave, longwave, and total broadband spectral regions of 0.2 to 5.0, 5.0 to 50.0, and 0.2 to 50.0 micrometers, respectively. Detailed models of the radiometers' response functions were developed in order to design the most suitable calibration techniques. These models guided the design of in-flight calibration procedures as well as the development and characterization of a vacuum-calibration chamber and the blackbody source which provided the absolute basis upon which the total and longwave radiometers were characterized. The flight calibration instrumentation for the narror-field-of-view scanning radiometers is presented and evaluated.

Lee, Robert B., III↗

In-flight validation and calibration of the spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Through an in-flight calibration experiment at Rogers Dry Lake, California on September 20, 1989, the radiometric and spectral properties of AVIRIS were determined. In-flight spectral channel positions and the spectral response function in 10 regions of the AVIRIS spectral range, taking in all four spectrometers, are shown to agree closely with the corresponding parameters measured in the laboratory. The intraflight stability for the Rogers Dry Lake calibration site is better than 2 percent with the exception of the strong atmospheric water absorptions where the measured radiance is close to zero. This experiment has provided both direct generation of an in-flight spectral and radiometric calibration and validation of the laboratory calibration at the reported level accuracy.

Green, Robert O.↗

Accuracy of the spectral and radiometric laboratory calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The laboratory procedures, algorithms, measurements, and uncertainties associated with generation of the spectral and radiometric calibration of data acquired by AVIRIS are described. AVIRIS is an airborne sensor that obtains high-spatial-resolution image data of the earth in 224 spectral channels in four spectrometers covering the range from 400 to 2450 nm. The spectral calibration of AVIRIS agrees with the in-flight data to within two nanometers, and the absolute radiometric calibration is consistent with the in-flight verification to 10 percent over the spectral range. In-flight radiometric stability as measured by five consecutive passes over the surface calibration site is reported to be between three and five percent.

Chrien, Thomas G.↗

Another Technique For Calibration Of Polarimetric Radar

Inexpensive technique involves four-stage procedure where different aspects of radar system calibrated at each stage. Provides calibration of relative phase, crosstalk, relative amplitude, and absolute amplitude. Only artificial target(s) required is at least one trihedral corner reflector. Advantage of four-step calibration procedure is that one does not have to perform entire procedure if one does not need full calibration.

Van Zyl, Jakob J.↗