Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Non-Invasive Assessment of Susceptibility to Ventricular Arrhythmias During Simulated Microgravity

The Cardiovascular Alterations Team is currently conducting studies to determine what alterations in hemodynamic regulation result from sixteen days of simulated microgravity exposure in normal human subjects. In this project we make additional measurements on these same study subjects in order to determine whether there is an increase in susceptibility to ventricular arrhythmias resulting from simulated microgravity exposure. Numerous anecdotal and documented reports from the past 30 years suggest that the incidence of ventricular arrhythmias among astronauts is increased during space flight. For example, documented runs of ventricular tachycardia have been recorded from crew members of Skylab and Mir, there was much attention given by the lay press to Mir Commander Vasily Tslbliyev's complaints of heart rhythm irregularities in July of 1997, and cardiovascular mechanisms may have been causal in the recent death of an experimental primate shortly after return from space. In 1986, a Mir cosmonaut, Alexander Laveikin, was brought home and replaced with an alternate cosmonaut as a result of cardiac dysrhythmias that began during extravehicular activity. Furthermore, at a joint NASA/NSBRI workshop held in January 1998, cardiac arrhythmias were identified as the highest priority cardiovascular risk to a human Mars mission. Despite the evidence for the risk of a potentially lethal arrhythmia resulting from microgravity exposure, the effects of space flight and the associated physiologic stresses on cardiac conduction processes are not known, and an increase in cardiac susceptibility to arrhythmias has never been quantified. In this project, we are determining whether simulated space flight increases the risk of developing life-threatening heart rhythm disturbances such as sustained ventricular tachycardia (defined as ventricular tachycardia lasting at least 30 seconds or resulting in hemodynamic collapse) and ventricular fibrillation. We are obtaining measures of cardiac susceptibility to ventricular arrhythmias in subjects exposed to simulated space flight in the Human Studies Core protocol being conducted by the Cardiovascular Alterations Team, which involves sixteen days .of bed rest. In particular, we are applying a powerful new non-invasive technology, developed in Professor Cohen's laboratory at MIT for the quantitative assessment of the risk of life-threatening ventricular arrhythmias. This technology involves the measurement of microvolt levels of T wave alternans (TWA) during exercise stress, and was recently granted approval by the Food and Drug Administration to be used for the clinical evaluation of patients suspected to be at risk of ventricular arrhythmias. In addition, we are obtaining 24 hour Holter monitoring (to detect non-sustained ventricular tachycardia and to assess heart rate variability). We are also conducting protocols to obtain these same measures on a monthly basis for up to four months in subjects in the Bone Demineralization/calcium Metaboloism Team's long term bed rest study.

Cohen, Richard J.↗

Novel Approach to Quantification of Telomere Length with Direct Nanopore Sequencing and PCR Amplification

The ends of human chromosomes contain telomeres, or tandem arrays of repeating DNA sequences capped by multiple associated proteins that protect chromosomal ends from degradation. Telomeres function to preserve genomic stability by preventing natural chromosomal ends from being recognized as broken DNA double-strand breaks and triggering inappropriate DNA damage responses. Mounting evidence shows telomere length is an inherited trait that decreases with cellular division and normal aging. In addition, telomere length also appears to be influenced by other factors such as cellular oxidative stress, radiation and mechanical unloading of tissues as in microgravity. To measure these potential effects of the space environment on telomere lengths and cellular aging and regenerative potential we developed a novel telomere measurement approach based on nanopore sequencing of PCR amplified bar-coded chromosome termini. Specifically, telomeres can be directly enriched using barcode sequences ligated to the end of a free end- repaired telomere using the WetLab-2 facility SmartCycler on ISS. Prior to the ligation and amplification protocol a proteinase K digestion of capping proteins followed by a single 95-degree C heat denaturation of the protease is included. After digestion and bar-code ligation, PCR amplification will initiate with the ligated barcoded sequence, suppressing amplification of intra-genomic fragments and resulting in long read barcoded telomere amplicons including the nanopore motor protein sequences. Purified PCR amplicons are then used for nanopore sequencing library generation by simple addition of motor proteins and sequencing library is loaded into the MinION nanopore DNA-sequencer. Amplicon sequence reads from the nanopore device can be base-called quickly on ISS due to barcoding ligation and subsequent PCR amplification enhancing the telomere sequence resolution. If successfully implemented on ISS this technique will provide a novel means of measuring regenerative ability of somatic stem cells in astronauts, and of determining whether spaceflight in microgravity alters their telomere lengths and causes premature cellular aging.

Ma, Kristin R.↗

Field-Dependent Magnetic Domain Behavior in van der Waals Fe 3 GeTe 2

Two-dimensional magnetic van der Waals (vdW) materials can show a variety of topological nontrivial spin textures, such as Bloch- or Néel-type stripe, skyrmion, or bubble domains under certain external stimuli. It is critical to understand the magnetic domain behavior in vdW materials in order to control their size and density in response to external stimuli, such as electric and magnetic fields. In this study, we examine the magnetic field dependence of topologically non-trivial magnetization spin textures in vdW Fe 3 GeTe 2 . Néel-type stripe domains and skyrmions are formed depending on the magnetic field-cooling protocol used during in situ Lorentz transmission electron microscopy (LTEM) experiments. Use of quantitative reconstruction of magnetic induction maps and micromagnetic simulations allow for the understanding of the LTEM results of Néel-type stripe domains as well as skyrmions. In addition, the deformation of skyrmion contrast is observed as a result of the introduction of an in-plane magnetic field. We demonstrate the stability of the stripe domains and skyrmions in response to an externally applied magnetic field due to an energy barrier for domain wall annihilation. Our results establish an understanding of the energy landscape that governs the behavior of the topologically non-trivial spin textures in vdW materials which can be harnessed for spintronic applications.

36 MATERIALS SCIENCE↗

Molecular modeling and simulation of Raney Nickel: From alloy precursor to the final porous catalyst

Raney Nickel is a nanostructured catalyst which is used in a variety of industrial processes. It has a characteristic porous, amorphous structure. Since the structure of both the precursor alloy and the active form of Raney Nickel is determining the catalytic activity and performance, it is crucial to use realistic porous structures for simulating the catalytic reaction. The simulation protocol for the formation of porous Raney Nickel is shown in this study. The structures are then characterized in-silico by means of typical characteristics such as the pore size, pore size distribution, density, free volume and free surface. In addition to this, the influence of the Aluminum content in the final form of the catalyst after pore formation is investigated. Furthermore, the cell size of the unit cell was doubled in x, y, and z directions to elucidate the influence of the impact of the cell size on the pore size.

alloy↗

Phase I Trial Using Proteasome Inhibitor Bortezomib and Concurrent Temozolomide and Radiotherapy for Central Nervous System Malignancies

Purpose: To evaluate the toxicity and response rate of bortezomib with concurrent radiotherapy and temozolomide in the treatment of patients with central nervous system malignancies. Patients and Methods: This open-label, dose-escalation, Phase I clinical study evaluated the safety of three dose levels of intravenously administered bortezomib (0.7, 1.0, and 1.3 mg/m{sup 2}/dose) on Days 1, 4, 8, and 11 of a 21-day cycle, in addition to concurrent radiotherapy and temozolomide at a daily dose of 75 mg/m{sup 2} starting on Day 1. The primary endpoint was dose-limiting toxicity, defined as any Grade 4-5 toxicity or Grade 3 toxicity directly attributable to protocol treatment, requiring hospitalization and/or radiotherapy interruption. The secondary endpoints included feasibility, non-dose-limiting toxicity, and treatment response. Results: A total of 27 patients were enrolled, 23 of whom had high-grade glioma (10 recurrent and 13 newly diagnosed). No dose-limiting toxicities were noted in any dose group, including the highest (1.3 mg/m{sup 2}/dose). The most frequent toxicities were Grade 1 and 2 stomatitis, erythema, and alopecia. All 27 patients were evaluable for response. At a median follow-up of 15.0 months, 9 patients were still alive, with a median survival of 17.4 months for all patients and 15.0 months for patients with high-grade glioma. Conclusion: Bortezomib administered at its typical 'systemic' dose (1.3 mg/m{sup 2}) is well tolerated and safe combined with temozolomide and radiotherapy when used in the treatment of central nervous system malignancies. A Phase II study to characterize efficacy is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervix Motion in 50 Cervical Cancer Patients Assessed by Daily Cone Beam Computed Tomographic Imaging of a New Type of Marker

Purpose: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. Methods and Materials: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss. In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. Results: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and −3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and −1.3/4.5/3.6 mm. Conclusions: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Devising novel methods for the controlled synthesis with morphology and size control of scintillator materials

Nanoscale scintillators represent an important class of materials underlying the functioning of high resolution, high ‘light yield’ radiation detection equipment, applicable for medicine in addition to security and environmental monitoring. This current study has focused on the controlled synthesis of Cs 2 ZnX 4 (X = Cl, Br) not only due to its very fast and promising radioluminescence decay time but also because no reliable synthesis protocols have been reported for producing nanoscale motifs of this material, to date. Solution-based methods can be used to synthesize products, possessing different, discrete morphologies with the ability to dictate particle size and shape. Specifically, we have demonstrated that a hot injection technique can be used to fabricate nanoscale rods and plates. Using this method, we systematically studied the effect of varying reaction variables, such as (i) reaction temperature, (ii) surfactants, and (iii) reaction time. As synthesized nanorods of Cs 2 ZnCl 4 possessed lengths of 101.3 ± 24.4 nm with widths of 17.3 ± 4.5 nm, whereas Cs 2 ZnBr 4 , created under identical conditions, were characterized by lengths of 206 ± 50 nm and widths of 26.7 ± 12.6 nm. Ligand-assisted re-precipitation (LARP) was used to produce the corresponding micron-sized particles. Under these conditions, we successfully synthesized spindles and spherical particles of Cs 2 ZnCl 4 with sizes of 1.58 ± 0.16 μm and 1.03 ± 0.34 μm, respectively, whereas plates of Cs 2 ZnBr 4 were prepared with average sizes of 0.76 ± 0.21 μm. High resolution synchrotron mapping, using the hard X-ray nanoprobe at NSLS II, was used to confirm the expected spatial distribution of Cs, Zn, and Cl within the as-produced crystals. Nanorods of Cs 2 ZnCl 4 and Cs 2 ZnBr 4 were subsequently tested for scintillation light yield and decay times. Preliminary results showed that Cs 2 ZnCl 4 maintained a light yield of 100–300 photons per MeV with a fast decay component of 2.6 ns. Finally, the Cs 2 ZnBr 4 analogue did not give rise to any perceptible scintillation emission.

36 MATERIALS SCIENCE↗

Bennett-Brassard 1984 quantum key distribution using conjugate homodyne detection

Optical homodyne detection has been widely used in continuous-variable (CV) quantum information processing for measuring field quadrature. In this paper we explore the possibility of operating a conjugate homodyne detection system in “photon counting” mode to implement discrete-variable (DV) quantum key distribution (QKD). A conjugate homodyne detection system, which consists of a beam splitter followed by two optical homodyne detectors, can simultaneously measure a pair of conjugate quadratures X and P of the incoming quantum state. In classical electrodynamics, X 2 + P 2 is proportional to the energy (the photon number) of the input light. In quantum optics, X and P do not commute and thus the above photon-number measurement is intrinsically noisy. This implies that a blind application of standard security proofs of QKD could result in pessimistic performance. We overcome this obstacle by taking advantage of two special features of the proposed detection scheme. First, the fundamental detection noise associated with vacuum fluctuations cannot be manipulated by an external adversary. Second, the ability to reconstruct the photon number distribution at the receiver's end can place additional constraints on possible attacks from the adversary. As an example, we study the security of the BB84 QKD using conjugate homodyne detection and evaluate its performance through numerical simulations. This study may open the door to a family of QKD protocols, complementary to the well-established DV-QKD based on single-photon detection and CV-QKD based on coherent detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Federal Facility Agreement and Consent Order: Nevada National Security Site Use Restriction Management Plan with ROTC 1

This Use Restriction Management Plan (URMP) provides the information needed to create, modify, and manage use restrictions (URs) for sites on the Nevada National Security Site (NNSS), and sites accessed through the NNSS main gate, that were closed using the corrective action alternative (CAA) of closure in place under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). (Note: This pertains to those FFACO sites not managed by the U.S. Department of Energy [DOE], Legacy Management.) The closure in place alternative is used for sites closed with residual contamination at levels requiring corrective action as determined using the FFACO process. The URs contain and control all requirements for long-term monitoring. This URMP also serves as the single repository of the URs implemented under the FFACO that identify use restricted areas and contain the current requirements for inspections, maintenance, and monitoring of the UR. The requirements in these URs replace all requirements listed in previous documentation. This consolidates post-closure monitoring requirements into a single source that ensures completeness and consistency of UR requirements and information. Standardized UR forms were developed to clearly document post-closure requirements that are consistent with current protocols and to ensure consistent information is contained in the URs. Standard notification, summary, and site controls statements were developed for all URs with provisions to insert site-specific options in the text. Current protocols for Industrial Sites and Soils URs are defined in this document and in the Soils Risk-Based Corrective Action (RBCA) Evaluation Process (DOE/EMNV, 2018). The standardized UR forms that have been approved to date are listed in Appendix A. Additional UR forms will be added once the review and approval process has been completed.

54 ENVIRONMENTAL SCIENCES↗

Acceleration Measurement and Characterization in Support of the USMP-4 Payloads

One common characteristic of the USMP-4 experiments is that various effects of gravity make it difficult, if not impossible, to achieve usable results when performing the experiments on Earth's surface. Therefore, the investigators took advantage of the microgravity environment afforded by being in low-Earth orbit to perform their research. Interpretation of the experiment results both during the mission and upon post-mission analyses of data and samples required an understanding of the microgravity environment in which the experiments were conducted. To achieve that understanding, data were collected using the Orbital Acceleration Research Experiment (OARE) and two Space Acceleration Measurement Systems (SAMS). Data from those systems, combined with an assessment of mission and experiment activities, were used to characterize the microgravity environment that existed on Columbia during the mission. The text herein gives details about some characteristics of the environment that were noted during the mission and during post-mission data analysis. The disturbances studied include the Ku-band antenna 17 Hz dither; the effect of changing the Orbiter attitude deadband limits; the effects of different bicycle ergometer configurations; and the effect of IDGE (Isothermal Dendritic Growth Experiment) experiment fans and SAMS computer hard drives. Additional information about the microgravity environment is provided. Supplementary data plots representing the environment throughout the majority of the mission are available at the Uniform Resource Locator (URL). Data files for both SAMS and OARE are accessible via anonymous file transfer protocol from the file server.

Rogers, M. J. B.↗

Comparison of Radon Results in 4- Versus 6-Plex Townhouse Units

In this work, to determine whether there were any significant differences in radon frequency between 4-unit (4-plex) and 6- unit (6-plex) multifamily buildings, an analysis was performed on three different populations of townhouses: one located within an Environmental Protection Agency (EPA) Radon Zone 1 site (Population A) and two others, both located in an EPA Radon Zone 3 site (Populations B and C). Within their respective population grouping, all units were two stories, identical in construction and floor plan, and were constructed by the same contractor over a 1- to 2-year period. In addition, each unit had its own separate, ducted forced-air heat pump. Long-term radon testing was performed using alpha track detectors (ATDs) for a period of 180 days. All detectors were placed in accordance with EPA residential sampling protocols (EPA 402-R-92-003) along the centerline of each unit. Followup testing (short-term, 7-day electret) was performed in all units in which the ATD test results were ≥4 pCi/L, and all elevated results were confirmed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Custom-designed heat treatment simultaneously resolves multiple challenges facing 3D-printed single-crystal superalloys

Single-crystal Ni-based superalloys are currently the material of choice for turbine blade applications, especially with the emerging additive manufacturing (AM) that facilitates the manufacture/repair of these single crystals. This promising AM route, however, comes with a dilemma: in the fusion and heat affected zones after e-beam or laser induced melting, one needs a solutionizing annealing to relieve the residual stresses and homogenize the chemical/microstructure. The super-solvus solutionizing temperature is usually adopted from the protocol for the cast superalloys, which almost always causes recrystallization and stray grain growth, resulting in a polycrystalline microstructure and degrading the high-temperature mechanical performance. Here, in this paper, we demonstrate a custom-designed post-printing heat treatment to replace the conventional super-solvus one. The recovery and relatively low temperature diminish the driving force for recrystallization and the movement of stray grain boundaries, without suffocating the chemical/microstructural homogenization thanks to the narrow dendrite width and short element segregation distance. The optimal duration of the heat treatment is proposed to achieve atomic-diffusion mediated chemical homogenization while limiting γ'-particle coarsening in the interdendritic regions. Our strategy makes it practically feasible to resolve several bottleneck problems with one processing/treatment, removing a seemingly formidable obstacle to effective additive manufacturing of superalloy single crystal products.

36 MATERIALS SCIENCE↗

Lifetime and Degradation Study of Poly(Methyl Methacrylate) via a Data-Driven Study Protocol Approach

We report to optimize and extend the service life of polymeric materials in outdoor environments, a domain knowledge-based and data-driven approach was utilized to quantitatively investigate the temporal evolution of degradation modes, mechanisms, and rates under various stepwise accelerated exposure conditions. Six formulations of poly(methyl methacrylate) (PMMA) with different combinations of stabilizing additives, including one unstabilized formulation, were exposed in three accelerated weathering conditions. Degradation was dependent on wavelength as samples in UV light at 340 nm (UVA) exposure showed the most yellowing. The unstabilized PMMA formulation showed much higher yellowness index values (59.5) than stabilized PMMA formulations (2–12). Urbach edge analysis shows a shift toward longer wavelength from 285 to 500 nm with increasing exposure time and an increased absorbance around 400 nm of visible region as the unstabilized samples increase in yellowing. The degradation mechanisms of PMMA were tracked using induced absorbance to dose at specific wavelengths that correspond to known degradation mechanisms. The degradation pathway of PMMA was modeled in a framework using network structural equation modeling (netSEM). netSEM showed changes in degradation pathway as PMMA transition stages of degradation.

36 MATERIALS SCIENCE↗

Anisotropic superconductivity of niobium based on its response to nonmagnetic disorder

Niobium is one of the most studied superconductors, both theoretically and experimentally. It is tremendously important for applications, and it has the highest superconducting transition temperature, T c = 9.32 K, of all pure metals. In addition to power applications in alloys, pure niobium is used for sensitive magnetosensing, radio-frequency cavities, and, more recently, as circuit metallization layers in superconducting qubits. A detailed understanding of its electronic and superconducting structure, especially its normal and superconducting state anisotropies, is crucial for mitigating the loss of quantum coherence in such devices. Recently, a microscopic theory of the anisotropic properties of niobium with the disorder was put forward. To verify theoretical predictions, we studied the effect of disorder produced by 3.5 MeV proton irradiation of thin Nb films grown by the same team and using the same protocols as those used in transmon qubits. By measuring the superconducting transition temperature and upper critical fields, we show a clear suppression of T c by potential (nonmagnetic) scattering, which is directly related to the anisotropic order parameter. Here, we obtain a very close quantitative agreement between the theory and the experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Do Intermediate Radiation Doses Contribute to Late Rectal Toxicity? An Analysis of Data From Radiation Therapy Oncology Group Protocol 94-06

Purpose: To investigate whether the volumes of rectum exposed to intermediate doses, from 30 to 50 Gy, contribute to the risk of Grade {>=}2 late rectal toxicity among patients with prostate cancer receiving radiotherapy. Methods and Materials: Data from 1009 patients treated on Radiation Therapy Oncology Group protocol 94-06 were analyzed using three approaches. First, the contribution of intermediate doses to a previously published fit of the Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model was determined. Next, the extent to which intermediate doses provide additional risk information, after taking the LKB model into account, was investigated. Third, the proportion of rectum receiving doses higher than a threshold, VDose, was computed for doses ranging from 5 to 85 Gy, and a multivariate Cox proportional hazards model was used to determine which of these parameters were significantly associated with time to Grade {>=}2 late rectal toxicity. Results: Doses <60 Gy had no detectable impact on the fit of the LKB model, as expected on the basis of the small estimate of the volume parameter (n = 0.077). Furthermore, there was no detectable difference in late rectal toxicity among cohorts with similar risk estimates from the LKB model but with different volumes of rectum exposed to intermediate doses. The multivariate Cox proportional hazards model selected V75 as the only value of VDose significantly associated with late rectal toxicity. Conclusions: There is no evidence from these data that intermediate doses influence the risk of Grade {>=}2 late rectal toxicity. Instead, the critical doses for this endpoint seem to be {>=}75 Gy. It is hypothesized that cases of Grade {>=}2 late rectal toxicity occurring among patients with V75 less than approximately 12% may be due to a 'background' level of risk, likely due mainly to biological factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C–IBI: Targeting cumulative coordination within an iterative protocol to derive coarse-grained models of (multi-component) complex fluids

We present a coarse-graining strategy that we test for aqueous mixtures. The method uses pair-wise cumulative coordination as a target function within an iterative Boltzmann inversion (IBI) like protocol. We name this method coordination iterative Boltzmann inversion (C–IBI). While the underlying coarse-grained model is still structure based and, thus, preserves pair-wise solution structure, our method also reproduces solvation thermodynamics of binary and/or ternary mixtures. In addition, we observe much faster convergence within C–IBI compared to IBI. To validate the robustness, we apply C–IBI to study test cases of solvation thermodynamics of aqueous urea and a triglycine solvation in aqueous urea.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-48: Automated Quality Assurance for XML Controlled Linacs

Purpose: To automate routine imaging QA procedures so that complying with TG 142 and TG 179 can be efficient and reliable. Methods: Two QA tests for a True Beam Linac were automatized. A Winston Lutz test as described by Lutz et al{sup 1} using the Winston Lutz test kit from BrainLab, Germany and a CBCT Image Quality test as described in TG 179 using the EMMA phantom, Siemens Medical Physics, Germany were performed in our True Beam. For each QA procedure tested, a 3 step paradigm was used. First, the data was automatically acquired using True Beam Developer Mode and XML scripting. Second, the data acquired in the first step was automatically processed using in-home grown Matlab GUIs. Third, Machine Learning algorithms were used to automatically classify the processed data and reports generated. Results: The Winston Luzt test could be performed by an experienced medical physicist in 29.0 ± 8.0 min. The same test, if automated using our paradigm, could be performed in 3.0 ± 0.1 min. In the same lieu, time could be substantially saved for image quality tests. In this case, the amount of time saved will depend on the phantoms used and the initial localization method. Additionally, machine learning algorithms could automatically identify the roots of the problems if any and possibly help reduce machine down time. Conclusion: Modern linear accelerators are equipped with advanced 2D and 3D imaging that are used for patient alignment substantially improving IGRT protocols. However, this extra complexity exponentially increases the number of QA tests needed. Using the new paradigm described above, not only bare minimum but best practice QA programs could be implemented with the same manpower. This work is supported by Varian, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Rheological diagnostic tools for state transitions

Thermodynamic or kinetic state transitions of six polymeric systems were probed using rheology in isothermal and nonisothermal isochronal experiments. The polymeric systems were representative of three different types of transitions: Gelation, macrophase separation, and order-disorder transitions. A phenomenological dimensionless parameter termed the relative elasticity, R, was found to be particularly sensitive to these transitions and was finitely bound by the viscous limit and the elastic limit with values of zero and one, respectively. In addition, the (time or temperature) derivative of R and tan δ (with δ being the phase angle) proved to be more sensitive to transitions as compared to the respective pure values. When compared to other methods found in literature, these new phenomenological protocols are found to be robust while providing a convenient and precise means of detecting transitions. Hence, they may complement existing methods, whereas they are beneficial to industrial or other systems exhibiting multiple transitions due to their high sensitivity.

42 ENGINEERING↗