Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Recent Activities at Tokai Tandem Accelerator

Recent activities at the JAEA-Tokai tandem accelerator facility are presented. The terminal voltage of the tandem accelerator reached 19.1 MV by replacing acceleration tubes. The multi-charged positive-ion injector was installed in the terminal of the tandem accelerator, supplying high-current noble-gas ions. A superconducting cavity for low-velocity ions was developed. Radioactive nuclear beams of {sup 8,9}Li and fission products, produced by the tandem accelerator and separated by the ISOL, were supplied with experiment. Recent results of nuclear physics experiments are reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Analysis of the Off-Normal Conditions of the SPIDER Accelerator

In the context of the development of the 1 MV neutral beam injector for the ITER tokamak, the study on beam formation and acceleration has considerable importance. This effort includes the ion source and accelerator SPIDER (Source for Production of Ions of Deuterium Extracted from an Rf plasma) ion source, planned to be built in Padova, and designed to extract and accelerate a 355 A/m{sup 2} current of H{sup -}(or 285 A/m{sup 2} D{sup -}) up to 100 kV. Exhaustive simulations were already carried out during the accelerator optimization leading to the present design. However, as it is expected that the accelerator shall operate also in case of pre-programmed or undesired off-normal conditions, the investigation of a large set of off-normal scenarios is necessary. These analyses will also be useful for the evaluation of the real performances of the machine, and should help in interpreting experimental results, or in identifying dangerous operating conditions.The present contribution offers an overview of the results obtained during the investigation of these off-normal conditions, by means of different modeling tools and codes. The results, showed a good flexibility of the device in different operating conditions. Where the consequences of the abnormalities appeared to be problematic further analysis were addressed.

43 PARTICLE ACCELERATORS↗

Optimized laser pulse profile for efficient radiation pressure acceleration of ions

The radiation pressure acceleration regime of laser ion acceleration requires high intensity laser pulses to function efficiently. Moreover the foil should be opaque for incident radiation during the interaction to ensure maximum momentum transfer from the pulse to the foil, which requires proper matching of the target to the laser pulse. However, in the ultrarela-tivistic regime, this leads to large acceleration distances, over which the high laser intensity for a Gaussian laser pulse must be maintained. It is shown that proper tailoring of the laser pulse profile can significantly reduce the acceleration distance, leading to a compact laser ion accelerator, requiring less energy to operate.

43 PARTICLE ACCELERATORS↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Terawatt attosecond x-ray source driven by a plasma accelerator

Plasma accelerators can generate ultra-high-brightness electron beams that open the door to light sources with a smaller physical footprint and properties un-achievable with conventional accelerator technology. In this paper, we show that electron beams from Plasma WakeField Accelerators can generate few-cycle coherent tunable soft x-ray pulses with TW peak power and a duration of tens of attoseconds, an order of magnitude more powerful, shorter, and with better stability than state-of-the-art X-ray Free Electron Lasers (XFELs). Such a light source would significantly enhance the ability to experimentally investigate electron dynamics on ultrafast timescales, having a broad-ranging impact across multiple scientific fields. Rather than starting from noise as in typical XFELs, the x-ray emission in this approach is driven by coherent radiation from a pre-bunched, high peak current electron beam of attosecond duration. This relaxes the restrictive tolerances that have hindered progress toward utilizing plasma accelerators as coherent x-ray drivers thus far, presenting a new paradigm for advanced accelerator light source applications.

43 PARTICLE ACCELERATORS↗

Growth of emittance in laser-plasma electron acceleration in guiding structures

We study angular characteristics, such as emittance and fraction of electrons emitted into a prescribed solid angle, for electron bunches that are accelerated in wake fields generated in various guiding structures – capillary waveguides and plasma channels, in which intense laser pulses propagate. The investigation is performed at various injection energies, which simulate input conditions to different cascades of a multistage electron accelerator. It is shown that, in contrast to the limitations issuing from the requirement of trapping and accelerating a substantial part of bunch electrons, the condition of maintaining the low emittance of the bunch, needed for successful transfer of the accelerated bunch to the entry of the next acceleration cascade or other device, imposes much more strict limitations on the accuracy of focusing of laser radiation to the guiding structure. (paper)

43 PARTICLE ACCELERATORS↗

Single Shot Characterization of High Transformer Ratio Wakefields in Nonlinear Plasma Acceleration

We report that plasma wakefields can enable very high accelerating gradients for frontier high energy particle accelerators, in excess of 10 GeV/m. To overcome limits on single stage acceleration, specially shaped drive beams can be used in both linear and nonlinear plasma wakefield accelerators (PWFA), to increase the transformer ratio, implying that the drive beam deceleration is minimized relative to acceleration obtained in the wake. In this Letter, we report the results of a nonlinear PWFA, high transformer ratio experiment using high-charge, longitudinally asymmetric drive beams in a plasma cell. An emittance exchange process is used to generate variable drive current profiles, in conjunction with a long (multiple plasma wavelength) witness beam. The witness beam is energy modulated by the wakefield, yielding a response that contains detailed spectral information in a single-shot measurement. Using these methods, we generate a variety of beam profiles and characterize the wakefields, directly observing transformer ratios up to R=7.8. Lastly, a spectrally based reconstruction technique, validated by 3D particle-in-cell simulations, is introduced to obtain the drive beam current profile from the decelerating wake data.

43 PARTICLE ACCELERATORS↗

Dense Plasma Focus Z-pinches for High Gradient Particle Acceleration

The final Z-pinch stage of a Dense Plasma Focus (DPF) could be used as a simple, compact, and potentially rugged plasma-based high-gradient accelerator with fields at the 100 MV/m level. In this paper we review previously published experimental beam data that indicate the feasibility of such an DPF-based accelerator, qualitatively discuss the physical acceleration processes in terms of the induced voltages, and as a starting point examine the DPF acceleration potential by numerically applying a self-consistent DPF system model that includes the induced voltage from both macroscopic and instability driven plasma dynamics. Applications to the remote detection of high explosives and a multi-staged acceleration concept are briefly discussed.

43 PARTICLE ACCELERATORS↗

Electrical Engineering in Los Alamos Neutron Science Center Accelerator

The field of electrical engineering plays a significant role in particle accelerator design and operations. Los Alamos National Laboratories LANSCE facility utilizes the electrical energy concepts of power distribution, plasma generation, radio frequency energy, electrostatic acceleration, signals and diagnostics. The culmination of these fields produces a machine of incredible potential with uses such as isotope production, neutron spallation, neutron imaging and particle analysis. The key isotope produced in LANSCE isotope production facility is Strontium-82 which is utilized for medical uses such as cancer treatment and positron emission tomography also known as PET scans. Neutron spallation is one of the very few methods used to produce neutrons for scientific research the other methods are natural decay of transuranic elements from nuclear reactors. Accelerator produce neutrons by accelerating charged particles into neutron dense elements such as tungsten imparting a neutral particle with kinetic energy, this has the benefit of producing a large number of neutrons as well as minimizing the waste generated. Utilizing the accelerator scientist can gain an understanding of how various particles behave and interact with matter to better understand the natural laws of physics and the universe around us.

43 PARTICLE ACCELERATORS↗

Staging For Wakefield Acceleration Experiment Hardware Development: Fast Kicker and High Power RF Delay Section

This project pursues demonstration of the complete staging of high gradient wakefield acceleration at Argonne Wakefield Accelerator (AWA) facility, which is well aligned with the core mission of AWA and the roadmap laid out for the dielectric wakefield accelerator technology toward future linear colliders. During the project, we have successfully demonstrated the feasibility of the staged short pulse TBA (C. Jing, et al, Nucl. Instrum. Meth. A., 898, 72-76, 2018). We have successfully performed the first over 100MW dielectric power extractor. As the last task, one of the key elements for the drive beam distribution system, the fast kicker, has been built and successfully demonstrated this year too. The staging technology demonstrated in this project is crucial for the 500MeV Demonstrator that is planned at AWA in the next five years. The plan is to use two staged meter long dielectric disk accelerators to achieve 500MeV energy gain within ~10 meter long experimental space. While this SBIR project is closed, we plan to continue to investigate the dielectric accelerator technologies under Euclid's general scientific and commercial interests.

43 PARTICLE ACCELERATORS↗

Toward a physics design for NDCX-II, an ion accelerator for warm dense matter and HIF target physics studies

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL), a collaborationof LBNL, LLNL, and PPPL, has achieved 60-fold pulse compression of ion beams on the Neutralized Drift Compression eXperiment (NDCX) at LBNL. In NDCX, a ramped voltage pulse from an induction cell imparts a velocity"tilt" to the beam; the beam's tail then catches up with its head in a plasma environment that provides neutralization. The HIFS-VNL's mission is to carry out studies of Warm Dense Matter (WDM) physics using ion beams as the energy source; an emerging thrust is basic target physics for heavy ion-driven Inertial Fusion Energy (IFE). These goals require an improved platform, labeled NDCX-II. Development of NDCX-II at modest cost was recently enabled by the availability of induction cells and associated hardware from the decommissioned Advanced Test Accelerator (ATA) facility at LLNL. Our initial physics design concept accelerates a ~;;30 nC pulse of Li+ ions to ~;;3 MeV, then compresses it to ~;;1 ns while focusing it onto a mm-scale spot. It uses the ATA cells themselves (with waveforms shaped by passive circuits) to impart the final velocity tilt; smart pulsers provide small corrections. The ATA accelerated electrons; acceleration of non-relativistic ions involves more complex beam dynamics both transversely and longitudinally. We are using analysis, an interactive one-dimensional kinetic simulation model, and multidimensional Warp-code simulations to develop the NDCX-II accelerator section. Both LSP and Warp codes are being applied to the beam dynamics in the neutralized drift and final focus regions, and the plasma injection process. The status of this effort is described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H-mode accelerating structures with PMQ focusing for low-beta ion beams

We are developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. Such IH-PMQ accelerating structures following a short RFQ can be used in the front end of ion linacs or in stand-alone applications, e.g. a compact deuteron-beam accelerator up to the energy of several MeV. Results of combined 3-D modeling for a full IH-PMQ accelerator tank - electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis - are presented. The accelerating field profile in the tank is tuned to provide the best beam propagation using coupled iterations of electromagnetic and beam-dynamics modeling. A cold model of the IH-PMQ tank is being manufactured.

43 PARTICLE ACCELERATORS↗

Linear accelerator design study with direct plasma injection scheme for warm dense matter

Warm Dense Matter (WDM) is a challenging science field, which is related to heavy ion inertial fusion and planetary science. It is difficult to expect the behavior because the state with high density and low temperature is completely different from ideal condition. The well-defined WDM generation is required to understand it. Moderate energy ion beams ({approx} MeV/u) slightly above Bragg peak is an advantageous method for WDM because of the uniform energy deposition. Direct Plasma Injection Scheme (DPIS) with a Interdigital H-mode (IH) accelerator has a potential for the beam parameter. We show feasible parameters of the IH accelerator for WDM. WDM physics is a challenging science and is strongly related to Heavy Ion Fusion science. WDM formation by Direct Plasma Injection Scheme (DPIS) with IH accelerator, which is a compact system, is proposed. Feasible parameters for IH accelerator are shown for WDM state. These represents that DPIS with IH accelerator can access a different parameter region of WDM.

43 PARTICLE ACCELERATORS↗

Toward a physics design for NDCX II, an ion accelerator for warm dense matter and HIF target physics studies

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL), a collaboration of LBNL, LLNL, and PPPL, has achieved 60-fold pulse compression of ion beams on the Neutralized Drift Compression eXperiment (NDCX) at LBNL. In NDCX, a ramped voltage pulse from an induction cell imparts a velocity 'tilt' to the beam; the beam's tail then catches up with its head in a plasma environment that provides neutralization. The HIFS-VNL's mission is to carry out studies of warm dense matter (WDM) physics using ion beams as the energy source; an emerging thrust is basic target physics for heavy ion-driven inertial fusion energy (IFE). These goals require an improved platform, labeled NDCX-II. Development of NDCX-II at modest cost was recently enabled by the availability of induction cells and associated hardware from the decommissioned advanced test accelerator (ATA) facility at LLNL. Our initial physics design concept accelerates an {approx} 30 nC pulse of Li{sup +} ions to {approx} 3 MeV, then compresses it to {approx} 1 ns while focusing it onto a mm-scale spot. It uses the ATA cells themselves (with waveforms shaped by passive circuits) to impart the final velocity tilt; smart pulsers provide small corrections. The ATA accelerated electrons; acceleration of non-relativistic ions involves more complex beam dynamics both transversely and longitudinally. We are using an interactive one-dimensional kinetic simulation model and multidimensional Warp-code simulations to develop the NDCX-II accelerator section. Both LSP and Warp codes are being applied to the beam dynamics in the neutralized drift and final focus regions, and the plasma injection process. The status of this effort is described.

43 PARTICLE ACCELERATORS↗

A facility for accelerator research and education at Fermilab

Fermilab is currently constructing the 'SRF Test Accelerator at the New Muon Lab' (NML). NML consists of a photo-emitted RF electron gun, followed by a bunch compressor, low energy test beamlines, SCRF accelerating structures, and high energy test beamlines. The initial primary purpose of NML will be to test superconducting RF accelerating modules for the ILC and for Fermilab's 'Project X' - a proposal for a high intensity proton source. The unique capability of NML will be to test these modules under conditions of high intensity electron beams with ILC-like beam parameters. In addition NML incorporates a photoinjector which offers significant tunability and especially the possibility to generate a bright electron beam with brightness comparable to state-of-the-art accelerators. This opens the exciting possibility of also using NML for fundamental beams research and tests of new concepts in beam manipulations and acceleration, instrumentation, and the applications of beams.

43 PARTICLE ACCELERATORS↗

Design and Principles of Linear Accelerators and Colliders." in Particle Physics Reference Library, pp. 295-336. Springer, Cham, 2020.

Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.

Seeman, John↗

Initial Results of Catheter-Directed Ultrasound-Accelerated Thrombolysis for Thromboembolic Obstructions of the Aortofemoral Arteries: A Feasibility Study

Purpose: This article reports the 30-day technical and clinical outcome of ultrasound (US)-accelerated thrombolysis in patients with aortofemoral arterial thromboembolic obstructions. Methods: A prospective cohort study was conducted from December 2008 to December 2009 of patients who were treated with US-accelerated thrombolysis for thromboembolic obstructions of aortofemoral arteries or bypasses. Urokinase was infused in a dosage of 100,000 IU per hour. Twice daily, a control angiography was performed. Thirty-day follow-up consisted of duplex scanning, combined with magnetic resonance angiography. Results: The study included 21 consecutive patients (20 men; median age, 66 (range, 52-80) years) with 24% artery versus 76% bypass occlusions. Median duration of symptoms was 11 (range, 7-140) days. Median occlusion length was 32 (range, 6-80) cm. In 20 patients (95%), an US-accelerated thrombolysis catheter could be successfully placed. In one patient, placement of an US-accelerated thrombolysis catheter was technically not feasible, and therefore a standard catheter was placed. Median thrombolysis time was 26.5 (range, 8.5-72) hours. Complete thrombolysis (>95% lysis of thrombus) was achieved in 20 patients; in 9 patients within 24 hours. Median ankle-brachial index (ABI) increased from 0.28 (range, 0-0.85) to 0.91 (range, 0.58-1.35). One patient had a thromboembolic complication and needed surgical intervention. No hemorrhagic complications, and no deaths occurred. At 30-day follow-up, 17 of 21 patients (81%) had a patent artery or bypass. Conclusions: This feasibility study showed a high technical success rate of US-accelerated thrombolysis for aortofemoral arterial obstructions. US-accelerated thrombolysis led to complete lysis within 24 hours in almost half of patients, with a low 30-day major complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗