At least 991 records · Page 55

Backscattering enhancement with a finite beam width for millimeter - wavelength weather radars

Backscattering enhancement from random hydrometeors should increase as wavelengths of radars reach millimeter regions. For 95 GHz radars, the reflectivity of backscattering is expected to increase by 2 dB, due to multiple scattering including backscattering enhancement, for water droplets of diameter of 1 mm with a density of 5×103 m−3. Previous theoretical studies of backscattering enhancement considered infinitely extending plane waves. In this paper, we expand the theory to spherical waves with a Gaussian antenna pattern, including depolarizing effects. While the differences from the plane wave results are not great when the optical thickness is small, as the latter increases the differences become significant, and essentially depend on the ratio of radar footprint radius to the mean free path of hydrometeors. In this regime, for a radar footprint that is smaller than the mean free path, the backscattering-enhancement reflectivity corresponding to spherical waves is significantly less pronounced than in the case of the plane wave theory. Hence this reduction factor must be taken into account when analyzing radar reflectivity factors for use in remote sensing applications.

Im, Eastwood↗

Large format long-wavelength infrared narrow-band, multi-band, and broad-band QWIP focal plane arrays

A 640x512 pixel, long-wavelength cutoff, narrow-band quantum well infrared photodetector focal pllay array, a four-band QWIP FPA in 4-16 um spectral region, and a broad-band QWIP FPA having 15.4 mum cutoff have been demonstrated. In this paper we discuss the detector designs, dark currents, quantum efficiencies, responsivities, detectivities, noise equivalent differential temperatures, the effect of FPA nonuniformity on performance, and the operabilities of these QWIP FPAs.

Mumolo, J. M.↗

Very Long Wavelength Intersubband Infrared Hot Electron Transistor

We have demonstrated the first very long wavelength (16 micrometer) infrared hot electron transistor (IHET). This device utilizes a bound to continuum quantum well infrared photodetector (QWIP) as a photosensitive emitter, a wide quantum well as a base, and a thick Al_xGa_(1-x)As barrier between the base and the collector as an energy discriminating filter. This energy filter blocks the lower energy electrons, which drain through the base while higher energy photo electrons pass to the collector. Therefore, the detectivity of the device at the collector is much higher than the detectivity at the emitter.

Park, J.S.↗

640 X 512 pixel long-wavelength infrared narrowband, multiband, and broadband QWIP focal plane arrays

A 640 512 pixel, long-wavelength cutoff, narrowband(delta lambda/lambda ~ 10%) quantum-well infrared photodetector(QWIP) focal plane array (FPA), a four-band QWIP FPA in the 4??m spectral region, and a broadband (delta lambda/lambda ~ 42%)QWIP FPA having a 15.4 m cutoff have been demonstrated. In this paper, we discuss the electrical and optical characterization of these FPAs, and their performance. In addition, we discuss the development of a very sensitive (NEDT ~ 10.6 mK) 640 X 512 pixel thermal imaging camera having a 9 lambda m cutoff.

broadband↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

Improvements to the Search for Cosmic Dawn Using the Long Wavelength Array

We present recent improvements to the search for the global Cosmic Dawn signature using the Long Wavelength Array station located on the Sevilleta National Wildlife Refuge in New Mexico, USA (LWA{SV). These improvements are both in the methodology of the experiment and the hardware of the station. An improved observing strategy along with more sophisticated temperature calibration and foreground modelling schemes have led to improved residual RMS limits. A large improvement over previous work using LWA{SV is the use of a novel achromatic beamforming technique which has been developed for LWA{SV. We present results from an observing campaign which contains 29 days of observations between March 10th, 2021 and April 10th 2021. The reported residual RMS limits are 6 times above the amplitude of the potential signal reported by the Experiment to Detect the Global EoR Signature (EDGES) collaboration.

Christopher Dilullo↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Surface Biology and Geology (SBG) Visible to Short Wavelength Infrared (VSWIR) Wide Swath Instrument Concept

The 2017 Decadal Survey: Thriving on Our Changing Planet, A Decadal Strategy for Earth Observation from Space has called new observations including global coverage Visible to Short Wavelength Infrared (VSWIR) Wide Swath (WS) imaging spectroscopy measurements as part of the Surface Biology and Geology (SBG) Designated Observable. The SBG VSWIR-WS along with the companion SBG Thermal Infrared (TIR) imager is an important element of NASA’s larger Earth System Observatory (ESO).

Walch, Marc↗

Mapping Cloud Microphysical Properties to Triple-Wavelength Airborne Lidar Measurements in Winter Storms: Results from the IMPACTS Field Campaign

Ice production and growth inmixed-phase cloudsgive a complicated picture of the radiative and mass characteristics due to the heterogeneity of particle shapes and sizes. Collocated airborne lidar and microphysics datasets from a recent winter storm field study are used to evaluate the effect of ice and liquid hydrometeors,observed in situ,on the multiple-wavelength backscatter coefficientvalues measured by the NASA Cloud Physics Lidarover the course of three winter deployments in the Midwestand Northeast United States.

Joseph A. Finlon↗

Heterodyne arrays at submillimeter wavelengths

Heterodyne receivers, which down-convert radio frequency (RF) signals to intermediate frequency (IF) signals - preserving the amplitude and phase information of the incoming radiation, are generally the detector of choice for high resolution spectroscopic studies in astrophysics and planetary remote sensing.

submillimeter wavelength↗

Future of heterodyne receivers at submillimeter wavelengths

In this review paper we examine these issues very carefully and describe the novel receivers being designed to make heterodyne instruments more competitive. It will be shown that heterodyne instruments will still have significant roles to play in the near future.

heterodyne↗

Multi-Anode Frequency Triplers at Sub-Millimeter Wavelengths

We report on the design methodology of fix-tuned split-block waveguide balanced frequency triplers working at 300,600 and 900 GHz. They feature four to six GaAs Schottky planar diodes in a balanced configuration. A 6-anode 300 GHz tripler, a 6-anode 560 GHz tripler and a 4-anode 900 GHz tripler will be fabricated with JPL membrane technology in order to minimize dielectric loading and ensure accurate thickness of the substrate. A 4-anode 600 GHz tripler was fabricated with JPL substrateless technology that delivers 0.8-1.6mW in the 540-640 GHz band at room temperature. When cooled to l2OK this tripler delivers 2-4mW from 540 to 640 GHz.

Schottky diodes↗