Irradiation Testing of Ultrasonic Transducers
Ultrasonic technologies offer the potential to mea
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Ultrasonic technologies offer the potential to mea
Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the capability, effectiveness, and reliability of ultrasonic testing (UT) as a replacement method for radiographic testing (RT) for inspecting nuclear power plant (NPP) components. A primary objective of this work is to evaluate UT techniques to assess their ability to detect, locate, size, and characterize fabrication flaws in typical NPP weldments. This particular study focused on the evaluation of four carbon steel pipe-to-pipe welds on specimens that ranged in thicknesses from 19.05 mm (0.75 in.) to 27.8 mm (1.094 in.) and were 355.6 mm (14.0 in.) or 406.4 mm (16.0 in.) in diameter. The pipe welds contained both implanted (intentional) fabrication flaws as well as bonus (unintentional) flaws throughout the entire thickness of the weld and the adjacent base material. The fabrication flaws were a combination of planar and volumetric flaw types, including incomplete fusion, incomplete penetration, cracks, porosity, and slag inclusions. The examinations were conducted using phased-array UT (PA UT) techniques applied primarily for detection and length sizing of the flaws. Radiographic examinations were also conducted on the specimens with RT detection and length sizing results being used to establish true state. This paper will discuss the comparison of UT and RT (true state) detection results conducted to date along with a discussion on the technical gaps that need to be addressed before these methods can be used interchangeably for repair and replacement activities for NPP components.
The Pacific Northwest National Laboratory (PNNL) is conducting studies for the U.S. Nuclear Regulatory Commission (NRC) to assess the capability, effectiveness, and reliability of ultrasonic testing (UT) as a replacement method for radiographic testing (RT) for volumetric examination of nuclear power plant (NPP) components. This particular study focused on evaluating the use of UT on carbon steel plate welds. Welding fabrication flaws included a combination of planar and volumetric types, e.g., incomplete fusion, lack of penetration, cracks, porosity, and slag inclusions. The examinations were conducted using phased-array (PA) UT techniques applied primarily for detection and flaw type characterization. This paper will discuss the results of using UT in lieu of RT for detection and classification of fabrication flaws in carbon steel plate welds.
Three ultrasonic instruments were evaluated by the Pacific Northwest National Laboratory (PNNL) to determine their ability to detect critical velocities for solids settling during slurry transfer operation between the Hanford Tank farms and the Waste Treatment and Immobilization Plant (WTP). The evaluation was conducted in a flow loop using prototypic transfer piping and a suite of simulants that encompass a broad range of waste physical and rheological properties that are likely encountered during Hanford tank waste transfer operations. The results from the evaluation are presented in this paper.
Oak Ridge National Laboratory researchers Ayyoub Momen and Viral Patel demonstrate a direct contact ultrasonic clothes dryer under development by ORNL in collaboration with General Electric (GE) Appliances. This novel approach uses high-frequency mechanical vibrations instead of heat to extract moisture as cold mist, dramatically reducing drying time and energy use. Funding for this project was competitively awarded by DOE’s Building Technologies Office in 2014.
In North America, several bat species commonly collide with operating turbines. Though the ultimate driver of collisions is unknown, studies suggest that bats may be attracted to turbines because they often approach and spend extended periods of time (seconds to minutes) interacting with turbine structures. To reduce bat mortality at wind farm operators, seek to reduce mortality rates by reducing the amount of time that bats interact with spinning turbine blades (or exposure). Current approaches to reduce exposure include curtailment, whereby turbine operators stop turbine rotors from spinning during periods when bats are expected to be at the highest risk of collision, and deterrent technologies that seek to discourage bats from entering/ limit the amount of time spent within the rotor swept area. We briefly describe the state of the science on ultrasonic deterrent technology, highlight potential drivers of variable efficacy for bat mortality reduction, and suggest next steps focus on identifying the driver(s) of such variability.
Ultrasonic spot welds were made between sheets of 0.8-mm-thick hot-dip-galvanized mild steel and 1.6-mm-thick AZ31B-H24. Lap-shear strengths of 3.0-4.2 kN were achieved with weld times of 0.3-1.2 s. Failure to achieve strong bonding of joints where the Zn coating was removed from the steel surface indicate that Zn is essential to the bonding mechanism. Microstructure characterization and microchemical analysis indicated temperatures at the AZ31-steel interfaces reached at least 344 C in less than 0.3 s. The elevated temperature conditions promoted annealing of the AZ31-H24 metal and chemical reactions between it and the Zn coating.
This paper gives a brief overview of a new project at LANL in structural damage identification for wind turbines. This project makes use of modeling capabilities and sensing technology to understand realistic blade loading on large turbine blades, with the goal of developing the technology needed to automatically detect early damage. Several structural health monitoring (SHM) techniques using piezoelectric active materials are being investigated for the development of wireless, low power sensors that interrogate sections of the wind turbine blade using Lamb wave propagation data, frequency response functions (FRFs), and time-series analysis methods. The modeling and sensor research will be compared with extensive experimental testing, including wind tunnel experiments, load and fatigue tests, and ultrasonic scans - on small- to mid-scale turbine blades. Furthermore, this study will investigate the effect of local damage on the global response of the blade by monitoring low-frequency response changes.
Knowledge of the elastic properties of partially molten rocks is crucial for understanding low-velocity regions in the interior of the Earth. Models of fluid and solid mixtures have demonstrated that significant decreases in seismic velocity are possible with small amounts of melt, but there is very little available data for testing these models, particularly with both P and S waves for mantle compositions. We report ultrasonic measurements of P and S velocities on a partially molten KLB-1 sample at mantle conditions using a multi-anvil device at a synchrotron facility. The P, S, and bulk sound velocities decrease as melting occurs. We find that the quantity, ∂lnV S /∂lnV B (where V B is the bulk sound velocity) is lower than mechanical models estimate. Instead, our data, as well as previous data in the literature, are consistent with a dynamic melting model in which melting and solidification interact with the stress field of the acoustic wave.
Experimental confirmation of various grain scattering theories exist but there are still outstanding questions concerning the characterization of microstructure using ultrasound. In this study, high purity niobium serves as a model material devoid of extrinsic scattering centers (e.g., voids, precipitates, second phase particles etc.) A range of microstructures were obtained by annealing in ultrahigh vacuum at different temperatures (600–800°C) after routine cold-rolling and recrystallization heat treatment. Ultrasonic attenuation is measured as a function of a frequency for each sample. For the samples with an intermediate grain size (typically ∼50 μm), attenuation follows a power law dependence on frequency with an exponent of n∼1.6, which is close to the prediction, n=2, of classical Stochastic scattering theory. However, quantitative comparison shows that the observed attenuation is higher than predicted by the classical theory. The Stanke-Kino unified grain scattering theory may provide an explanation for the lower frequency dependence than traditional theories predict, though it still under predicts the magnitude of the attenuation. In any event, the resulting empirical relations provide a useful approach for practical grain size measurement with an acceptable level of uncertainty. The effect of a layered microstructure typical of some sheets/plates is discussed.
The NiFe{sub 2}O{sub 4} magnetic nanoparticles synthesized and used to prepare stable water-based magnetic nanofluids of various concentrations by ultrasonically assisted two-step techniques. Thermophysical investigations are made on the nanofluids at different temperatures ranging from 20 to 80 °C. The measurements revealed that the thermal conductivity of nanofluids significantly enhances with an increase in the percentage of nanoparticle volume fraction. The thermal conductivity measurements showed that the maximum enhancement is 32.65% achieved at 1% nanoparticle volume fraction and at 80 °C. Specific heat of nanofluids was decreased with increasing nanoparticle volume fractions, and it augments with increasing temperature. Viscosity measurements showed that nanofluid had a Newtonian behavior at all nanoparticle volume fractions and temperatures considered. The viscosity of the nanofluid increased with increasing nanoparticle concentration and decreasing temperature. Experimental results revealed that the viscosity sensitivity to temperature variation is minor, while it is more sensitive to the variations of nanoparticle volume fraction. The density of nanofluids was increased with increasing nanoparticle volume fractions and decreased with increasing temperature. Lastly, efforts were made to provide a precise correlation to estimate the thermal conductivity, as well as other thermophysical properties at various temperatures and volume fractions of nanoparticles. The comparison between the results and the correlation results showed a good agreement.
The results of the effect of ultrasonic treatment of ZnSe crystals on the structure of the energy spectrum of electronic states of centers with deep levels forming photoelectric and luminescent properties of this compound are presented. It is for the first time proved experimentally that the climb of edge dislocations under the effect of ultrasound leads to regrouping and generation of defects forming deep levels, which manifest themselves in phenomena of photosensitivity and radiative recombination.
In this paper, we report evidence for enhanced elemental interdiffusion during ultrasonic additive manufacturing (UAM) across metal boundaries of copper-aluminum, nickel-gold, and nickel-gold-aluminum. The high solute interdiffusion measured by energy dispersive X-ray spectroscopy line scans is rationalized with calculated vacancy concentrations orders of magnitude larger than thermal equilibrium values. The above estimates are supported by existing knowledge related to defect physics and UAM thermal cycles. The observation of pronounced elemental mixing are evidence for the presence of enhanced non-equilibrium immiscible metal interdiffusion during UAM processing.
Near-surface layers in Zr-18%Nb alloy were modified using ultrasonic impact treatment (UIT). The effects of the UIT processing time on a microstructural formation, omega/alpha precipitations, microhardness and corrosion are analyzed. XRD analysis, TEM and SEM observations and EDX characterization allow establishing the links between the microstructure, microhardness and corrosion behavior of the surface layers formed. At the strain extent up to e ≈ 0.3, structural formation occurs under influence of deformation induced heating, which facilitates omega precipitation in beta phase and mechanically induced oxygen transport and oxide formation. XRD analysis reveals moderate compressive residual stresses (− 160 MPa) and pronounced {110} texture after the UIT process. Generation of dislocations and hindering of their movement by nanoscale omega precipitates manifest themselves as the broadening of diffraction peaks occurred mainly owing to the lattice microstrains, and they provide marked strain hardening. The enhanced anticorrosion properties of Zr-18%Nb alloy in saline solution were concluded to be a result of the formation of a protective oxide film, {110} texture and compressive stresses.
This paper is focused on the effects of the separately applied laser heat treatment (LHT) and ultrasonic impact treatment (UIT) and the combined LHT + UIT process on the wear and friction behaviors of the hardened surface layers of the tool steel AISI D2. In comparison with the initial state, wear losses of the treated specimens after long-term wear tests were decreased by 68, 41, and 77% at the LHT, UIT, and combined LHT + UIT processes, respectively. The Abbott–Firestone bearing curves were used to analyze the material ratio and functional characterization (bearing capacity and oil capacitance) of the studied surface specimens. The wear losses registered after short (15 min) tests correlate well with the changes in experimental surface roughness Ra, and the predictive Rpk, and bearing capacity B{sub C} parameters, respectively, evaluated using the Abbott–Firestone curves and Kragelsky–Kombalov formula. The wear losses after the long-term (45 min) tests are in good correlation with the reciprocal surface microhardness HV and with the W{sub L} and W{sub P} wear parameters, respectively, estimated using Archard–Rabinowicz formula and complex roughness-and-strength approach. The observed HV increase is supported by nanotwins (LHT), by dense dislocation nets (UIT), and by dislocation cells/nanograins fixed with fine carbides (LHT + UIT) formed in the surface layers of the steel.
Ultrasonic additive manufacturing (UAM) is a three-dimensional metal printing technology which uses high-frequency vibrations to scrub and weld together both similar and dissimilar metal foils. There is no melting in the process and no special atmosphere requirements are needed. Consequently, dissimilar metals can be joined with little to no intermetallic compound formation, and large components can be manufactured. These attributes have the potential to transform manufacturing of nuclear reactor core components such as control elements for the High Flux Isotope Reactor at Oak Ridge National Laboratory. These components are hybrid structures consisting of an outer cladding layer in contact with the coolant with neutron-absorbing materials inside, such as neutron poisons for reactor control purposes. UAM systems are built into a computer numerical control (CNC) framework to utilize intermittent subtractive processes. These subtractive processes are used to introduce internal features as the component is being built and for net shaping. The CNC framework is also used for controlling the motion of the welding operation. Lastly, it is demonstrated here that curved components with embedded features can be produced using a five-axis code for the welder for the first time.
Microalgae are a promising feedstock for biofuel production, but difficulties associated with harvesting suspended cultures contribute to the high costs of algal feedstock production. Ultrasonic harvesting has been identified as a potential low-cost technique, but limited data are available on the response of microalgae cells in the presence of an acoustic field. The acoustic radiation force acting on a cell depends upon cell size and the acoustic contrast factor (ACF) of the cell in the media. The ACF depends upon the density and compressibility of the cell and the media. Cell size and ACF were measured for Microchloropsis gaditana, Nannochloropsis oculata, Phaeodactylum tricornutum, and Chlamydomonas reinhardtii. The average ACFs, which were determined by measuring the densities and sound velocities of suspensions containing varying concentrations of cells in growth media, were 0.04 (range = 0.03–0.05) for M. gaditana, 0.02 (range = 0.01–0.04) for N. oculata, 0.05 (range = 0.04–0.07) for P. tricornutum, and 0.05 (range = 0.049–0.053) for C. reinhardtii. The ratio of the acoustic radiation force to the drag force would be highest for C. reinhardtii cells due to their larger effective radius (5.6 μm compared to 1.9–2.7 μm for the other species). The effective ACF of C. reinhardtii was also evaluated by recording the motion of cells in the presence of an acoustic field, using particle tracking velocimetry, and then modeling the recorded motion using COMSOL Multiphysics software. The result (ACF = 0.04) demonstrated agreement with the density/sound velocity meter method. Experiments with starch null sta6 mutant C. reinhardtii cells demonstrated that the effective ACF can transition from positive to zero and eventually become negative as microalgae cells accumulate lipids. Furthermore, the dynamic nature of the ACF represents an opportunity and a challenge for acoustic harvesting of algal cells.
Here, in this work we infer the underlying distribution on pore radius in human cortical bone samples using ultrasonic attenuation data. We first discuss how to formulate polydisperse attenuation models using a probabilistic approach and the Waterman Truell model for scattering attenuation. We then compare the Independent Scattering Approximation and the higher-order Waterman Truell models’ forward predictions for total attenuation in polydisperse samples. Following this, we formulate an inverse problem under the Prohorov Metric Framework coupled with variational regularization to stabilize this inverse problem. We then use experimental attenuation data taken from human cadaver samples and solve inverse problems resulting in nonparametric estimates of the probability density function on pore radius. We compare these estimates to the “true” microstructure of the bone samples determined via microCT imaging. We find that our methodology allows us to reliably estimate the underlying microstructure of the bone from attenuation data.