Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UTILITY INTERCONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

500+ Million Years of Volcanism in Australe

The roughly circular collection of mare deposits in the "Mare Australe" region (38.9°S, 93°E) is ~900 km in diameter. The maria erupted into post-basin impact craters but are generally disconnected from each other. The distribution of maria could reflect what might have been the early stages of other basin filling mare eruptions, but which are preserved in Australe and some farside locations [1-3]. Topographic data fail to indicate a 900-km basin, but gravity and topographic data suggest a 600-km basin in the northern part of Australe [6]. The relationship between the basin and the wider-spread mare deposits is unclear, particularly outside the basin. We utilized images, gravity, topography, and composition to investigate the timing of volcanism in "Mare Australe" to interpret the evolution of magmatism in Australe and how it might relate to other mare sources. Humboldt crater (~3.6 Ga) makes an excellent stratigraphic marker that can be traced across much of the deposits and serves as a stratigraphic calibration for absolute model ages (AMAs) derived from crater size-frequency distributions (CSFDs). We found a range of AMAs from ~3.3 to 3.8 Ga in north Australe, similar to previous studies [4], and there is also evidence for multiple deposits of older cryptomaria. The age range, however, is narrower than for maria in other basins (e.g., Imbrium and South Pole-Aitken [4-5]), suggesting different magmatism in Australe. Most of the mare deposits are >3.5 Ga; younger deposits are co-located in the north basin. The basin may have provided additional pathways for rising magma to the surface over time. We also found evidence of a several interconnected deposits within the north basin. Other, smaller deposits, however, clearly show distinct age differences between units within a single topographic depression (e.g., Lyot crater) and likely represent discrete eruptions. Additionally, there are no floor fractured craters other than Humboldt [6], suggesting that magma generally did not stall out near the surface, also consistent with gravity and (lack of) magnetic anomalies (in contrast to Marius Hills and South Pole-Aitken basin [7-8]).

Julie Dawn Stopar↗

Analysis of Drought Impacts on Electricity Production in the Western and Texas Interconnections of the United States

Electricity generation relies heavily on water resources and their availability. To examine the interdependence of energy and water in the electricity context, the impacts of a severe drought to assess the risk posed by drought to electricity generation within the western and Texas interconnections has been examined. The historical drought patterns in the western United States were analyzed, and the risk posed by drought to electricity generation within the region was evaluated. The results of this effort will be used to develop scenarios for medium- and long-term transmission modeling and planning efforts by the Western Electricity Coordination Council (WECC) and the Electric Reliability Council of Texas (ERCOT). The study was performed in response to a request developed by the Western Governors Association in conjunction with the transmission modeling teams at the participating interconnections. It is part of a U.S. Department of Energy-sponsored, national laboratory-led research effort to develop tools related to the interdependency of energy and water as part of a larger interconnection-wide transmission planning project funded under the American Recovery and Reinvestment Act. This study accomplished three main objectives. It provided a thorough literature review of recent studies of drought and the potential implications for electricity generation. It analyzed historical drought patterns in the western United States and used the results to develop three design drought scenarios. Finally, it quantified the risk to electricity generation for each of eight basins for each of the three drought scenarios and considered the implications for transmission planning. Literature on drought impacts on electricity generation describes a number of examples where hydroelectric generation capacity has been limited because of drought but only a few examples of impact on thermoelectric generation. In all documented cases, shortfalls of generation were met by purchasing power from the market, albeit at higher prices. However, sufficient excess generation and transmission must be available for this strategy to work. Although power purchase was the most commonly discussed drought mitigation strategy, a total of 12 response strategies were identified in the literature, falling into four main categories: electricity supply, electricity demand response, alternative water supplies, and water demand response. Three hydrological drought scenarios were developed based on a literature review and historical data analysis. The literature review helped to identify key drought parameters and data on drought frequency and severity. Historical hydrological drought data were analyzed for the western United States to identify potential drought correlations and estimate drought parameters. The first scenario was a West-wide drought occurring in 1977; it represented a severe drought in five of the eight basins in the study area. A second drought scenario was artificially defined by selecting the conditions from the 10th-percentile drought year for each individual basin; this drought was defined in this way to allow more consistent analysis of risk to electricity generation in each basin. The final scenario was based upon the current low-flow hydro modeling scenario defined by WECC, which uses conditions from the year 2001. These scenarios were then used to quantify the risk to electricity generation in each basin. The risk calculations represent a first-order estimate of the maximum amount of electricity generation that might be lost from both hydroelectric and thermoelectric sources under a worst-case scenario. Even with the conservative methodology used, the majority of basins showed a limited amount of risk under most scenarios. The level of risk in these basins is likely to be amenable to mitigation by known strategies, combined with existing reserve generation and transmission capacity. However, the risks to the Pacific Northwest and Texas Basins require further study. The Pacific Northwest is vulnerable because of its heavy reliance on hydroelectric generation. Texas, conversely, is vulnerable because of its heavy dependence on thermoelectric generation, which relies on surface water for cooling, along with the fact that this basin seems to experience more severe drought events on average. Further modeling analysis will be performed in conjunction with the modeling teams at the participating interconnections (WECC and ERCOT) to explore the transmission implications of the drought scenarios in more detail. Given the first-order nature of this analysis, more detailed study of the potential impacts of drought on electricity generation is recommended. Future analyses should attempt to model the potential impacts of drought at the power-plant level, including potential mitigation strategies; include the effects of drought duration; understand the impacts of climate change; and consider economic impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PV Cyber Security Research (Final Report)

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid support functions which can drastically influence power quality, voltage, and bulk system frequency. This project was split into two phases. The first provided a survey and roadmap of the cybersecurity for the solar industry. The second investigated multiple PV cybersecurity research and development (R&D) concepts identified in the first phase. In the first year, the team created a roadmap for improving cybersecurity for distributed solar energy resources. This roadmap was intended to provide direction for the nation over the next five years and focused on the intersection of industry and government and recommends activities in four related areas: stakeholder engagement, cyber security research and development, standards development, and industry best practices. At the same time, the team produced a primer for DER vendors, aggregators, and grid operators to establish a common taxonomy and describe basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. This material was motivated by the need to assist the broader PV industry with cybersecurity resilience and describe the state-of-the-art for securing DER communications. Lastly, an adversary-based assessment of multiple PV devices was completed at the Distributed Energy Technologies Laboratory at Sandia National Laboratories to determine the status of industry cybersecurity practices. The team found multiple deficiencies in the security features of the assessed devices. In the second year, a set of recommendations was created for DER communication protocols— especially with respect to the state-of-the-art requirements in IEEE 2030.5. Additionally, several cybersecurity R&D technologies related to communications-enabled photovoltaic systems were studied to harden DER communication networks. Specifically, the team investigated (a) using software defined networking to create a moving target defense system for DER communications, and (b) engineering controls that prevent misprogramming or adversary action on DER devices/networks by disallowing setpoints that will generate unstable power system operations.

14 SOLAR ENERGY↗

NASA’s Space Sustainability Strategy: An Overview and a Conceptual Framework for Implementation

Space sustainability is crucial for the continuation of humanity's exploration and utilization of space. NASA recognizes the imperative of maintaining a sustainable space operating environment to safeguard the future of space activities. On April 9, 2024, NASA released its first part of an integrated Space Sustainability Strategy focused on the domain of earth orbit, with future volumes to address impacts of space operations on earth itself; cislunar space, including the Lagrange points and the lunar surface; and deep space, including other celestial bodies. This commitment extends to ensuring the safety of astronauts conducting operations in Low Earth Orbit (LEO), as well as enabling missions to the Moon and Mars. Moreover, sustainable space practices are essential for the uninterrupted operation of NASA's robotic science missions, which monitor Earth's changes and probe the mysteries of the universe. The strategy sets out a set of goals, the first of which is to establish a framework for assessing space sustainability at NASA, addressing the absence of a universally accepted framework with key metrics that promotes understanding of how metrics are interconnected. This framework will provide a basis for evaluating the sustainability of orbital activities, with metrics informed by input from the domestic and international space community. Objectives under this goal include defining key parameters affecting space sustainability, determining tolerable levels of risk, and annually publishing NASA's effect on space sustainability, including compliance with orbital debris mitigation standards. The subsequent goals build upon this foundation, identifying effective actions for enhancing space sustainability, incentivizing adoption of these actions through technology development and policy changes, and ensuring coordination with the global space community. An organizational change within NASA is also proposed to facilitate day-to-day coordination and accountability for space sustainability efforts. By pursuing these goals, NASA aims to strengthen the technical foundations of and continue to set an example for sustainable space operations. Regular evaluation of NASA mission performance in context with meeting sustainability objectives will ensure alignment with evolving challenges in the space operating environment.

Matt Forsbacka↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating Residual Solids Volume In Underground Storage Tanks

The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large-Scale Wind Integration Studies in the United States: Preliminary Results

The National Renewable Energy Laboratory, under the sponsorship of the U.S. Department of Energy, is managing two large-scale wind integration studies. The Western Wind and Solar Integration Study (WWSIS) covers the footprint of WestConnect, a group of transmission owners that covers most of Colorado, New Mexico, Arizona, Nevada, and Wyoming. The Eastern Wind Integration and Transmission Study (EWITS) covers a large part of the Eastern Interconnection, and leverages a large-scale transmission study known as the Joint Coordinated System Plan (JCSP). Both studies analyze the impact of 20-30% wind energy penetration within the study footprint based on energy. This paper discusses key results that have emerged so far from each study, focusing primarily on simulation results based on hourly production simulations. Results from both studies show that high wind penetrations can be successfully integrated into the power system, but depend on sufficient transmission and significant changes in operations.

17 WIND ENERGY↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Expandable LED array interconnect

A light emitting device that can function as an array element in an expandable array of such devices. The light emitting device comprises a substrate that has a top surface and a plurality of edges. Input and output terminals are mounted to the top surface of the substrate. Both terminals comprise a plurality of contact pads disposed proximate to the edges of the substrate, allowing for easy access to both terminals from multiple edges of the substrate. A lighting element is mounted to the top surface of the substrate. The lighting element is connected between the input and output terminals. The contact pads provide multiple access points to the terminals which allow for greater flexibility in design when the devices are used as array elements in an expandable array.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Specific Grain Boundary Resistivity Measurements in Thin Film Copper Bicrystals

A technique to estimate the specific grain boundary resistivity contribution in Cu lines using nanoscale four-probe STM measurements across thin film bamboo grain boundaries is presented. FIB milling of evaporated copper films was utilized to create Cu lines of various widths (400-4 microns). BSE and OIM microscopy was used to characterize the microstructure and texture of annealed Cu films containing these lines. Preliminary measurements using a fixed probe spacing with the four-probe STM technique indicated the sensitivity of the technique to detect variations in resistances along the length of the line though conversion to resistivities resulted in abnormally high values likely caused by material redeposition and/or Ga ion impregnation during FIB milling.

36 MATERIALS SCIENCE↗

An ancient Chinese wisdom for metabolic engineering: Yin-Yang

In ancient Chinese philosophy, Yin-Yang describes two contrary forces that are interconnected and interdependent. This concept also holds true in microbial cell factories, where Yin represents energy metabolism in the form of ATP, and Yang represents carbon metabolism. Current biotechnology can effectively edit the microbial genome or introduce novel enzymes to redirect carbon fluxes. On the other hand, microbial metabolism loses significant free energy as heat when converting sugar into ATP; while maintenance energy expenditures further aggravate ATP shortage. The limitation of cell “powerhouse” prevents hosts from achieving high carbon yields and rates. Via an Escherichia coli flux balance analysis model, we further demonstrate the penalty of ATP cost on biofuel synthesis. To ensure cell powerhouse being sufficient in microbial cell factories, we propose five principles: 1. Take advantage of native pathways for product synthesis. 2. Pursue biosynthesis relying only on pathways or genetic parts without significant ATP burden. 3. Combine microbial production with chemical conversions (semi-biosynthesis) to reduce biosynthesis steps. 4. Create “minimal cells” or use non-model microbial hosts with higher energy fitness. 5. Develop a photosynthesis chassis that can utilize light energy and cheap carbon feedstocks. Meanwhile, metabolic flux analysis can be used to quantify both carbon and energy metabolisms. The fluxomics results are essential to evaluate the industrial potential of laboratory strains, avoiding false starts and dead ends during metabolic engineering

59 BASIC BIOLOGICAL SCIENCES↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Prototype and Codesign of Nascent Flexible Wave Energy Converter Concepts

Prevailing mainstream ocean wave energy converter (WEC) archetypes are often relatively large monolithic rigid bodies with singular means of power take-off (e.g., relative motion between rigid bodies) and solo prime mover mechanisms (e.g. a rotary generator, a hydraulic piston). These mainstream WEC archetypes have existed for decades with some having histories spanning more than a century of significant investments and interests. As an alternative to the domain of mainstream WEC archetypes is the domain of distributed embedded energy converter technologies (also known as DEEC-Tec). Use of DEEC-Tec to create WECs - often called flexWECs - is a nascent domain of research and development that centers itself upon the interconnection of many relatively small energy converters - very small energy transducers - that interconnect and combine to create a much larger, overall, energy converting structure. The DEEC-Tec domain enables promising possibilities such as: direct in situ ocean wave energy harvesting and conversion throughout the volume of an entire flexWEC; inherent broad-banded ocean wave energy capture and conversion arising from near semi-continuous structural degrees of freedom; an innate absence of focusing and concentrating of ocean wave energy into a single prime mover and/or transmission system; and built-in implicit redundancy. As such, the DEEC-Tec domain could revolutionize how we conceptualize ocean wave energy conversion - both in terms of ocean wave energy converter design and what we view as viable environments and circumstances for ocean wave energy conversion. The research and development opportunities for the DEEC-Tec domain, therefore, are vast compared to the prevailing mainstream ocean wave energy converter domain. Correspondingly, there are ample opportunities to invest time and money into the DEEC-Tec domain with an aim to enable a paradigm shift in how ocean waves can be utilized as a more viable form of renewable energy. To that end, two seedling efforts have been enacted providing a very cursory investigation into the DEEC-Tec domain: (1) a preliminary simple fabrication/prototyping effort and (2) a preliminary co-design effort. The prototype seedling centers upon the design of a fabrication and evaluation rig for individual DEEC-Tec transducers; e.g., dielectric elastomer generators. The co-design seedling centers upon the analysis of those methods suitable for DEEC-Tec, ocean wave energy conversion, and fluid-structure interaction co-design efforts.

50 EE - Wind and Water Power Program - Water (EE-4↗

Explainable AI for Multivariate Time Series Pattern Exploration: Latent Space Visual Analytics With Temporal Fusion Transformer and Variational Autoencoders in Power Grid Event Diagnosis

Detecting and analyzing complex patterns in multivariate time-series data is crucial for decision-making in urban and environmental system operations. However, challenges arise from the high dimensionality, intricate complexity, and interconnected nature of complex patterns, which hinder the understanding of their underlying physical processes. Existing AI methods often face limitations in interpretability, computational efficiency, and scalability, reducing their applicability in real-world scenarios. This paper proposes a novel visual analytics framework that integrates two generative AI models, Temporal Fusion Transformer (TFT) and Variational Autoencoders (VAEs), to reduce complex patterns into lower-dimensional latent spaces and visualize them in 2D using dimensionality reduction techniques such as PCA, t-SNE, and UMAP with DBSCAN. These visualizations, presented through coordinated and interactive views and tailored glyphs, enable intuitive exploration of complex multivariate temporal patterns, identifying patterns’ similarities and uncover their potential correlations for a better interpretability of the AI outputs. The framework is demonstrated through a case study on power grid signal data, where it identifies multi-label grid event signatures, including faults and anomalies with diverse root causes. Additionally, novel metrics and visualizations are introduced to validate the models and assess the performance, efficiency, and consistency of latent maps generated by VAE, which have been utilized in prior studies for latent space cartography and used as a benchmark in this study, and the emerging TFT architecture under various configurations. These analyses provide actionable insights for model parameter tuning and reliability improvements. Comparative results highlight that TFT achieves shorter run times and superior scalability to diverse time-series data shapes compared to VAE. This work advances fault diagnosis in multivariate time series, fostering explainable AI to support critical system operations.

Explainable AI↗

REopt: A Platform for Energy System Integration and Optimization: Preprint

REopt is NREL's energy planning platform offering concurrent, multi-technology integration and optimization capabilities to help clients meet their cost savings and energy performance goals. The REopt platform provides techno-economic decision-support analysis throughout the energy planning process, from agency-level screening and macro planning to project development to energy asset operation. REopt employs an integrated approach to optimizing a site?s energy costs by considering electricity and thermal consumption, resource availability, complex tariff structures including time-of-use, demand and sell-back rates, incentives, net-metering, and interconnection limits. Formulated as a mixed integer linear program, REopt recommends an optimally-sized mix of conventional and renewable energy, and energy storage technologies; estimates the net present value associated with implementing those technologies; and provides the cost-optimal dispatch strategy for operating them at maximum economic efficiency. The REopt platform can be customized to address a variety of energy optimization scenarios including policy, microgrid, and operational energy applications. This paper presents the REopt techno-economic model along with two examples of recently completed analysis projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗