Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Evaluation of Four-Dimensional Computed Tomography-Based Intensity-Modulated and Respiratory-Gated Radiotherapy Techniques for Pancreatic Carcinoma

Purpose: To compare conformal radiotherapy (CRT), intensity-modulated radiotherapy (IMRT), and respiration-gated radiotherapy (RGRT) planning techniques for pancreatic cancer. All target volumes were determined using four-dimensional computed tomography scans (4D CT). Methods and Materials: The pancreatic tumor and enlarged regional lymph nodes were contoured on all 10 phases of a planning 4D CT scan for 10 patients, and the planning target volumes (PTV{sub allphases}) were generated. Three consecutive respiratory phases for RGRT delivery in both inspiration and expiration were identified, and the corresponding PTVs (PTV{sub inspiration} and PTV{sub expiration}) and organ at risk volumes created. Treatment plans using CRT and IMRT, with and without RGRT, were created for each PTV. Results: Compared with the CRT plans, IMRT significantly reduced the mean volume of right kidney exposed to 20 Gy from 27.7% {+-} 17.7% to 16.0% {+-} 18.2% (standard deviation) (p < 0.01), but this was not achieved for the left kidney (11.1% {+-} 14.2% to 5.7% {+-} 6.5%; p = 0.1). The IMRT plans also reduced the mean gastric, hepatic, and small bowel doses (p < 0.01). No additional reductions in the dose to the kidneys or other organs at risk were seen when RGRT plans were combined with either CRT or IMRT, and the findings for RGRT in end-expiration and end-inspiration were similar. Conclusion: 4D CT-based IMRT plans for pancreatic tumors significantly reduced the radiation doses to the right kidney, liver, stomach, and small bowel compared with CRT plans. The additional dosimetric benefits from RGRT appear limited in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Exploratory Study Into the Role of Dynamic Contrast-Enhanced Magnetic Resonance Imaging or Perfusion Computed Tomography for Detection of Intratumoral Hypoxia in Head-and-Neck Cancer

Purpose: Hypoxia in patients with head-and-neck cancer (HNC) is well established and known to cause radiation resistance and treatment failure in the management of HNC. This study examines the role of parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and perfusion computed tomography (CT) as surrogate markers of intratumoral hypoxia, defined by using the exogenous marker of hypoxia pimonidazole and the endogenous marker carbonic anhydrase 9 (CA9). Methods and Materials: Patients with HNC underwent preoperative DCE-MRI, perfusion CT, and pimonidazole infusion. Imaging parameters were correlated with pimonidazole and CA9 staining. The strength of correlations was tested by using a two-tailed Spearman's rank correlation coefficient. Results: Twenty-three regions of interest were analyzed from the 7 patients who completed the DCE-MRI studies. A number of statistically significant correlations were seen between DCE-MRI parameters (volume transfer between blood plasma and extracellular extravascular space [EES], volume of EES, rate constant between EES and blood plasma, time at arrival of contrast inflow, time to peak, average gradient, and time to onset) and areas with a pimonidazole score of 4. In the case of CA9 staining, only a weak correlation was shown with wash-in rate. There were no significant correlations between perfusion CT parameters and pimonidazole staining or CA9 expression. Conclusion: Intratumoral hypoxia in patients with HNC may be predicted by using DCE-MRI; however, perfusion CT requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography Before and After Definitive Radiation Therapy in Patients With Apparently Solitary Plasmacytoma

Purpose: To evaluate the impact of {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) on management of patients with apparently isolated plasmacytoma. Methods and Materials: Twenty-one patients with apparently solitary plasmacytoma who underwent FDG-PET for staging or restaging were identified from a central PET database. They were either candidates for or had received definitive radiation therapy (RT). Results: Seventeen patients had initial staging scans for bone (n = 11) or soft tissue (n = 6) plasmacytomas, and 11 had PET scans after RT. Only 1 of 14 known untreated sites of plasmacytoma was not identified on staging PET (lesion sensitivity = 93%). Three plasmacytomas were excised before PET. Staging PET influenced management in 6 of 17 patients (35%) by showing multiple myeloma (n = 1), discouraging RT after complete resection (n = 1), excluding plasmacytoma at a second site (n = 1), by increasing RT fields (n = 2), or by suggesting sarcoidosis (n = 1). Fifteen of 17 patients with initial staging PET scans received definitive RT. Restaging PET scans after RT showed complete metabolic response in 8 of 11 cases and progressive disease in 2. Two patients with either no response or partial metabolic response had late responses. Staging sestamibi and PET scans were concordant in five of six occasions (one sestamibi scan was false negative). Conclusions: FDG-PET has value for staging and RT planning in plasmacytoma and potentially could have a role in response-assessment after RT. Slow resolution of FDG uptake posttreatment does not necessarily imply an adverse prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative [18F]Fluorodeoxyglucose Positron Emission Tomography Standardized Uptake Value of Neck Lymph Nodes Predicts Neck Cancer Control and Survival Rates in Patients With Oral Cavity Squamous Cell Carcinoma and Pathologically Positive Lymph Nodes

Purpose: Survival in oral cavity squamous cell carcinoma (OSCC) depends heavily on locoregional control. In this prospective study, we sought to investigate whether preoperative maximum standardized uptake value of the neck lymph nodes (SUVnodal-max) may predict prognosis in OSCC patients. Methods and Materials: A total of 120 OSCC patients with pathologically positive lymph nodes were investigated. All subjects underwent a [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET) scan within 2 weeks before radical surgery and neck dissection. All patients were followed up for at least 24 months after surgery or until death. Postoperative adjuvant therapy was performed in the presence of pathologic risk factors. Optimal cutoff values of SUVnodal-max were chosen based on 5-year disease-free survival (DFS), disease-specific survival (DSS), and overall survival (OS). Independent prognosticators were identified by Cox regression analysis. Results: The median follow-up for surviving patients was 41 months. The optimal cutoff value for SUVnodal-max was 5.7. Multivariate analyses identified the following independent predictors of poor outcome: SUVnodal-max {>=}5.7 for the 5-year neck cancer control rate, distant metastatic rate, DFS, DSS, and extracapsular spread (ECS) for the 5-year DSS and OS. Among ECS patients, the presence of a SUVnodal-max {>=}5.7 identified patients with the worst prognosis. Conclusion: A SUVnodal-max of 5.7, either alone or in combination with ECS, is an independent prognosticator for 5-year neck cancer control and survival rates in OSCC patients with pathologically positive lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose From Kilovoltage Cone Beam Computed Tomography in an Image-Guided Radiotherapy Procedure

Purpose: Image-guided radiation therapy has emerged as the new paradigm in radiotherapy. This work is to provide detailed information concerning the additional imaging doses to patients' radiosensitive organs from a kilovoltage cone beam computed tomography (kV CBCT) scan procedure. Methods and Materials: The Vanderbilt-Monte-Carlo-Beam-Calibration (VMCBC; Vanderbilt University, Nashville, TN) algorithm was used to calculate radiation dose to organs resulting from a kV CBCT imaging guidance procedure. Eight patients, including 3 pediatric and 5 adult patients, were investigated. The CBCT scans in both full- and half-fan modes were studied. Results: For a head-and-neck scan in half-fan mode, dose-volume histogram analyses show mean doses of 7 and 8 cGy to the eyes, 5 and 6 cGy to the spinal cord, 5 and 6 cGy to the brain, and 18 and 23 cGy to the cervical vertebrae for an adult and a 29-month-old child, respectively. The dose from a scan in full-fan mode is 10-20% lower than that in half-fan mode. For an abdominal scan, mean doses are 3 and 7 cGy to prostate and 7 and 17 cGy to femoral heads for a large adult patient and a 31-month-old pediatric patient, respectively. Conclusions: Doses to radiosensitive organs can total 300 cGy accrued over an entire treatment course if kV CBCT scans are acquired daily. These findings provide needed data for clinicians to make informed decisions concerning additional imaging doses. The dose to bone is two to four times greater than dose to soft tissue for kV x-rays, which should be considered, especially for pediatric patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performed for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Should Patient Setup in Lung Cancer Be Based on the Primary Tumor? An Analysis of Tumor Coverage and Normal Tissue Dose Using Repeated Positron Emission Tomography/Computed Tomography Imaging

Purpose: Evaluation of the dose distribution for lung cancer patients using a patient setup procedure based on the bony anatomy or the primary tumor. Methods and materials: For 39 patients with non-small-cell lung cancer, the planning fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scan was registered to a repeated FDG-PET/CT scan made in the second week of treatment. Two patient setup methods were analyzed based on the bony anatomy or the primary tumor. The original treatment plan was copied to the repeated scan, and target and normal tissue structures were delineated. Dose distributions were analyzed using dose-volume histograms for the primary tumor, lymph nodes, lungs, and spinal cord. Results: One patient showed decreased dose coverage of the primary tumor caused by progressive disease and required replanning to achieve adequate coverage. For the other patients, the minimum dose to the primary tumor did not significantly deviate from the planned dose: -0.2 {+-} 1.7% (p = 0.71) and -0.1 {+-} 1.7% (p = 0.85) for the bony anatomy setup and the primary tumor setup, respectively. For patients (n = 31) with nodal involvement, 10% showed a decrease in minimum dose larger than 5% for the bony anatomy setup and 13% for the primary tumor setup. The mean lung dose exceeded the maximum allowed 20 Gy in 21% of the patients for the bony anatomy setup and in 13% for the primary tumor setup, whereas for the spinal cord this occurred in 10% and 13% of the patients, respectively. Conclusions: In 10% and 13% of patients with nodal involvement, setup based on bony anatomy or primary tumor, respectively, led to important dose deviations in nodal target volumes. Overdosage of critical structures occurred in 10-20% of the patients. In cases of progressive disease, repeated imaging revealed underdosage of the primary tumor. Development of practical ways for setup procedures based on repeated high-quality imaging of all tumor sites during radiotherapy should therefore be an important research focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Positron Emission Tomography-Staged Clinical N3 Breast Cancer Treated With Neoadjuvant Chemotherapy, Surgery, and Radiotherapy

Purpose: To evaluate the treatment outcome and efficacy of regional lymph node irradiation after neoadjuvant chemotherapy (NCT) and surgery in positron emission tomography (PET)-positive clinical N3 (cN3) breast cancer patients. Methods and Materials: A total of 55 patients with ipsilateral infraclavicular (ICL), internal mammary (IMN), or supraclavicular (SCL) lymph node involvement in the absence of distant metastases, as revealed by an initial PET scan, were retrospectively analyzed. The clinical nodal stage at diagnosis (2002 AJCC) was cN3a in 14 patients (26%), cN3b in 12 patients (22%), and cN3c in 29 patients (53%). All patients were treated with NCT, followed by mastectomy or breast-conserving surgery and subsequent radiotherapy (RT) with curative intent. Results: At the median follow-up of 38 months (range, 9-80 months), 20 patients (36%) had developed treatment failures, including distant metastases either alone or combined with locoregional recurrences that included one ipsilateral breast recurrence (IBR), six regional failures (RF), and one case of combined IBR and RF. Only 3 patients (5.5%) exhibited treatment failure at the initial PET-positive clinical N3 lymph node. The 5-year locoregional relapse-free survival, disease-free survival (DFS), and overall survival rates were 80%, 60%, and 79%, respectively. RT delivered to PET-positive IMN regions in cN3b patients and at higher doses ({>=}55 Gy) to SCL regions in cN3c patients was not associated with improved 5-year IMN/SCL relapse-free survival or DFS. Conclusion: NCT followed by surgery and RT, including the regional lymph nodes, resulted in excellent locoregional control for patients with PET-positive cN3 breast cancer. The primary treatment failure in this group was due to distant metastasis rather than RF. Neither higher-dose RT directed at PET-positive SCL nodes nor coverage of PET-positive IMN nodes was associated with additional gains in locoregional control or DFS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Computed Tomography in the Management of the Neck After Chemoradiotherapy in Patients With Head-and-Neck Cancer

Purpose: The aim of this study was to describe the outcome in patients with head-and neck-squamous cell carcinoma (HNSCC) followed up without neck dissection (ND) after concomitant chemoradiotherapy (CRT) based on computed tomography (CT) response. The second objective was to establish CT characteristics that can predict which patients can safely avoid ND. Methods and Materials: Between 1998 and 2007, 369 patients with node-positive HNSCC were treated with primary CRT at our institution. After a clinical and a radiologic evaluation based on CT done 6 to 8 weeks after CRT, patients were labeled with a complete neck response (CR) or with a partial neck response (PR). Results: The median follow-up was 44 months. The number of patients presenting with N3, N2, or N1 disease were 54 (15%), 268 (72%), and 47 (13%), respectively. After CRT, 263 (71%) patients reached a CR, and 253 of them did not undergo ND. Ninety-six patients reached a PR and underwent ND. Of those, 34 (35%) had residual disease on pathologic evaluation. A regression of the diameter of {>=}80% and a residual largest diameter of 15 mm of nodes had negative pathologic predictive values of 100% and 86%, respectively. The 3-year regional control and survival rates were not different between patients with CR who had no ND and patients with PR followed by ND. Conclusion: Node-positive patients presenting a CR as determined by CT evaluation 6 to 8 weeks after CRT had a low rate of regional recurrence without ND. This study also suggests that lymph node residual size and percentage of regression on CT after CRT may be useful criteria to guide clinical decisions regarding neck surgery. Those results can help diminish the number of ND procedures with negative results and their associated surgical complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Physical Examination and Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography 4-6 Months After Radiotherapy to Assess Residual Head-and-Neck Cancer

Purpose: To retrospectively compare fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and physical examination 4-6 months after radiotherapy for assessing residual head-and-neck cancer (HNC). Methods and Materials: From July 2002 through March 2006, 52 HNC patients underwent definitive radiotherapy or chemoradiotherapy. Categoric assessments of residual tumor by PET/CT and physical examination 4-6 months after therapy were correlated and compared with clinical outcomes. Pretreatment data, including tumor stage and primary site standardized uptake value, were also gathered retrospectively and correlated with clinical outcomes. Median follow-up time was 58 months. Results: Twenty-one patients had either locoregionally 'positive' (17 of 21) or 'equivocal' (4 of 21) PET/CT scans, whereas 31 patients had locoregionally negative scans. Four patients failed treatment and had biopsy-confirmed residual or recurrent local disease. All patients, including patients with locally suspicious scans or examinations who refused biopsies, were followed clinically for a minimum of 29 months after therapy, with no other cases of treatment failure detected during this time. No patient had residual nodal disease after therapy. Sensitivities of PET/CT vs. physical examination for early detection of treatment failure were 100% vs. 50%, whereas the specificities of the two modalities were 64.6% vs. 89.6%, respectively. Higher initial T stage and American Joint Commission on Cancer stage correlated with increased incidence of positive/equivocal PET/CT results and treatment failure. Maximal standardized uptake value was not predictive of any clinical outcome. Conclusions: A negative result on PET/CT obtained 4-6 months after radiotherapy is highly sensitive and correlates with successful locoregional control. Patients with negative scans may reasonably be spared invasive diagnostic procedures, such as biopsy and neck dissection, unless recurrent disease is suspected on clinical grounds. Close follow-up is prudent for HNC patients with abnormal findings on posttherapy PET/CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Positron Emission Tomography With Fluorine-18-Fluorodeoxyglucose in Predicting Treatment Response in Unresectable Hepatocellular Carcinoma Patients Treated With External Beam Radiotherapy

Purpose: To assess the significance of the ratio between standardized uptake values (SUV) of tumor and normal liver tissue obtained from positron emission tomography with fluorine-18-fluorodeoxyglucose (FDG-PET) in predicting the response of hepatocellular carcinoma (HCC) patients treated with external beam radiotherapy (EBRT). Methods and Materials: We retrospectively analyzed 35 HCC patients who were treated with EBRT between January 2004 and June 2007. All patients underwent FDG-PET in which SUV values were obtained from tumor and normal liver tissues and were used to calculate the ratios (SUV{sub Tumor}/SUV{sub Liver}). After FDG-PET, patients received liver treatment including concurrent chemoradiation, transarterial chemoembolization plus RT, or intraarterial chemotherapy plus RT. Using three-dimensional conformal RT, median dose of 45 Gy was delivered in conventional fractions. Patients underwent abdominal/pelvic CT 1 month after RT, and treatment responses were evaluated according to the Response Evaluation Criteria in Solid Tumors criteria. Results: Patients were divided into high-SUV ratio group (n = 20) and low-SUV ratio group (n = 15) according to SUV ratio at a cutoff value of 2.5. Objective responses consisting of either complete response (CR) or partial response (PR) were observed in 16 and 6 patients (46% vs. 17%, p = 0.015), respectively; median survivals after RT were 8 months and 5 months (p = 0.41) for the high-SUV ratio group and the low-SUV ratio group, respectively. Rates of intrahepatic metastases (9% vs. 11%, p = 0.39) and distant metastases (32% vs. 32%, p = 0.27) showed no significant difference between two groups. Conclusions: External beam RT for HCC patients with higher SUV ratios resulted in higher response rates than for patients with lower SUV ratios. Treatment of HCC with higher SUV ratios did not result in increased survival; high rates of intrahepatic and distant metastases in both SUV groups may have affected patient survival. SUV ratios from pre-RT FDG-PET may be beneficial for selecting patients who are likely to respond to EBRT for unresectable HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Clinical Evaluation of a Three-Dimensional Cone-Beam Computed Tomography Estimation Method Using a Deformation Field Map

Purpose: To develop a three-dimensional (3D) cone-beam computed tomography (CBCT) estimation method using a deformation field map, and to evaluate and optimize the efficiency and accuracy of the method for use in the clinical setting. Methods and Materials: We propose a method to estimate patient CBCT images using prior information and a deformation model. Patients' previous CBCT data are used as the prior information, and the new CBCT volume to be estimated is considered as a deformation of the prior image volume. The deformation field map is solved by minimizing deformation energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. This method was implemented in 3D form using hardware acceleration and multi-resolution scheme, and it was evaluated for different scan angles, projection numbers, and scan directions using liver, lung, and prostate cancer patient data. The accuracy of the estimation was evaluated by comparing the organ volume difference and the similarity between estimated CBCT and the CBCT reconstructed from fully sampled projections. Results: Results showed that scan direction and number of projections do not have significant effects on the CBCT estimation accuracy. The total scan angle is the dominant factor affecting the accuracy of the CBCT estimation algorithm. Larger scan angles yield better estimation accuracy than smaller scan angles. Lung cancer patient data showed that the estimation error of the 3D lung tumor volume was reduced from 13.3% to 4.3% when the scan angle was increased from 60 Degree-Sign to 360 Degree-Sign using 57 projections. Conclusions: The proposed estimation method is applicable for 3D DTS, 3D CBCT, four-dimensional CBCT, and four-dimensional DTS image estimation. This method has the potential for significantly reducing the imaging dose and improving the image quality by removing the organ distortion artifacts and streak artifacts shown in images reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Megavoltage Cone Beam Computed Tomography Dose and the Necessity of Reoptimization for Imaging Dose-Integrated Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: Megavoltage cone beam computed tomography (MV-CBCT) dose can be integrated with the patient's prescription. Here, we investigated the effects of imaging dose and the necessity for additional optimization when using intensity-modulated radiotherapy (IMRT) to treat prostate cancer. Methods and Materials: An arc beam mimicking MV-CBCT was generated using XiO (version 4.50; Elekta, Stockholm, Sweden). The monitor units (MU) for dose calculation were determined by conforming the calculated dose to the dose measured using an ionization chamber. IMRT treatment plans of 22 patients with prostate cancer were retrospectively analyzed. Arc beams of 3, 5, 8, and 15 MU were added to the IMRT plans, and the dose covering 95% of the planning target volume (PTV) was normalized to the prescribed dose with (reoptimization) or without optimization (compensation). Results: PTV homogeneity and conformality changed negligibly with MV-CBCT integration. For critical organs, an imaging dose-dependent increase was observed for the mean rectal/bladder dose (D{sub mean}), and reoptimization effectively suppressed the D{sub mean} elevations. The bladder generalized equivalent uniform dose (gEUD) increased with imaging dose, and reoptimization suppressed the gEUD elevation when 5- to 15-MU CBCT were added, although rectal gEUD changed negligibly with any imaging dose. Whereas the dose elevation from the simple addition of the imaging dose uniformly increased rectal and bladder dose, the rectal D{sub mean} increase of compensation plans was due mainly to low-dose volumes. In contrast, bladder high-dose volumes were increased by integrating the CBCT dose, and reoptimization reduced them when 5- to 15-MU CBCT were added. Conclusion: Reoptimization is clearly beneficial for reducing dose to critical organs, elevated by addition of high-MU CBCT, especially for the bladder. For low-MU CBCT aimed at bony structure visualization, compensation is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Organ Motion During Chemoradiotherapy of Rectal Cancer Using Cone-Beam Computed Tomography

Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCT images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion

Purpose: To characterize and quantify multiorgan respiration-induced motion in the abdomen in liver and pancreatic cancer patients. Methods and Materials: Four-dimensional computed tomography scans were acquired for 18 patients treated for abdominal tumors. Contours of multiple abdominal organs were drawn by the radiation oncologist at one respiratory phase; these contours were propagated to other respiratory phases by deformable registration. Three-dimensional organ models were generated from the resulting contours at each phase. Motions of the bounding box and center of mass were extracted and analyzed for the clinical target volume and organs at risk. Results: On average, the center of mass motion for liver clinical target volumes was 9.7 mm (SD 5 mm) in the superior-inferior direction, with a range of 3 to 18 mm; for pancreatic tumors, the average was 5 mm (SD 1 mm) m with a range of 3 to 7 mm. Abdominal organs move in unison, but with varying amplitudes. Gating near exhale (T40-T60) reduces the range of motion by a factor of {approx}10. Conclusion: We have used deformable registration to calculate the trajectories of abdominal organs in four dimensions, based on center of mass and bounding box motion metrics. Our results are compared with previously reported studies. Possible reasons for differences are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy

Purpose: The purpose of the present study was to quantify the concomitant dose received by patients undergoing cone beam computed tomography (CBCT) scanning in different clinical scenarios as a part of image-guided radiotherapy (IGRT) procedures. Methods and Materials: We calculated the three-dimensional concomitant dose received as a result of CBCT scans in 6 patients representing different clinical scenarios: two pelvis, two head and neck, and two chest. We assessed the effect that a daily on-line IGRT strategy would have on the patient dose distribution, assuming 40 CBCT scans throughout the treatment course. The additional dose to the planning target volume margin region was also estimated. Results: In the pelvis, a single CBCT scan delivered a mean dose to the femoral heads of 2-6 cGy and the rectum of 1-2 cGy. An additional dose to the planning target volume was within 1-3 cGy. In the chest, the mean dose to the planning target volume varied from 2.5 to 5 cGy. The lung and spinal cord planning organ at risk volume received {<=}4 cGy and {<=}5 cGy, respectively. In the head and neck, a single CBCT scan delivered a mean dose of 0.3 cGy, with bony structures receiving 0.5-0.8 cGy. The femoral heads received an additional dose of 1.5-2.5 Gy. A reduction of 20-30% in the mean dose to the organs at risk was achieved using bowtie filtration. In the head and neck, the dose to the eyes and brainstem was eliminated by decreasing the craniocaudal field size. Conclusions: The additional dose from on-line IGRT procedures can be clinically relevant. The organ dose can be significantly reduced with the use of appropriate patient-specific settings. The concomitant dose from CBCT should be accounted for and the acquisition settings optimized for optimal IGRT strategies on a patient basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guidance During Head-and-Neck Cancer Radiation Therapy: Analysis of Alignment Trends With In-Room Cone-Beam Computed Tomography Scans

Purpose: On-board cone-beam computed tomography (CBCT) is currently available for alignment of patients with head-and-neck cancer before radiotherapy. However, daily CBCT is time intensive and increases the overall radiation dose. We assessed the feasibility of using the average couch shifts from the first several CBCTs to estimate and correct for the presumed systematic setup error. Methods and Materials: 56 patients with head-and-neck cancer who received daily CBCT before intensity-modulated radiation therapy had recorded shift values in the medial-lateral, superior-inferior, and anterior-posterior dimensions. The average displacements in each direction were calculated for each patient based on the first five or 10 CBCT shifts and were presumed to represent the systematic setup error. The residual error after this correction was determined by subtracting the calculated shifts from the shifts obtained using daily CBCT. Results: The magnitude of the average daily residual three-dimensional (3D) error was 4.8 {+-} 1.4 mm, 3.9 {+-} 1.3 mm, and 3.7 {+-} 1.1 mm for uncorrected, five CBCT corrected, and 10 CBCT corrected protocols, respectively. With no image guidance, 40.8% of fractions would have been >5 mm off target. Using the first five CBCT shifts to correct subsequent fractions, this percentage decreased to 19.0% of all fractions delivered and decreased the percentage of patients with average daily 3D errors >5 mm from 35.7% to 14.3% vs. no image guidance. Using an average of the first 10 CBCT shifts did not significantly improve this outcome. Conclusions: Using the first five CBCT shift measurements as an estimation of the systematic setup error improves daily setup accuracy for a subset of patients with head-and-neck cancer receiving intensity-modulated radiation therapy and primarily benefited those with large 3D correction vectors (>5 mm). Daily CBCT is still necessary until methods are developed that more accurately determine which patients may benefit from alternative imaging strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes, mediastinal lymph nodes, and unsuspected sites of distant metastasis. This information is important in the design of radiotherapy treatment fields and, therefore, we recommend that PET/CT be a component of initial staging for IBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗