Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Heat resistant nontoxic laminate

Light-weight low-cost laminate used to replace epoxy compound panels is suitable for auto, railcar, and aircraft structural parts. Physical and thermal tests show panels made from formulation have better insulative properties, and burn cleaner with less toxic gas generation than panels made with conventional materials.

Kourtides, D. A.↗

High temperature strain gage evaluation

The structural thermal test of an advanced ramjet missile section required strain measurements as high as 922 K (1200 F). Since there is relatively little experience in the use of strain gages above the 700-755 K (800-900 F) level, a program was initiated to select and evaluate the best available gage. Candidate gages suitable for measurements up to 922 K (1200 F) were selected. This involved the determination of their operating characteristics, availability, cost, installation aspects, etc. The evaluation involved the following tests: strain as a function of load at room temperature and apparent strain as a function of temperature.

Gonzalez, J. I.↗

Porous tooling process for manufacture of graphite/polyimide composites

A porous tooling system was selected for the processing of Graphite/PMR-15 Polyimide laminates in thickness up to 3.2 mm. (0.125 inch). This tool system must have a reasonable strength, permeability dimensional stability, and thermal conductivity to accomplish curing at 600 F and 200 psi and 200 psi autoclave temperature and pressure. A permeability measuring apparatus was constructed and permeability vs. casting water level determined to produce tools at three different permeability levels. On these tools, laminates of 5, 11, and 22 plies (.027, .060, and 0.121 inch) were produced and evaluated by ultrasonic, mechanical, and thermal tests to determine the effect of the tool permeability on the cured laminates. All tools produced acceptable laminates at 5 and 11 plies but only the highest permeability produced acceptable clear ultrasonic C-Scans. Recommendations are made for future investigations of design geometry, and strengthening techniques for porous ceramic tooling.

Smiser, L. W.↗

Photovoltaic module bypass diode encapsulation

The design and processing techniques necessary to incorporate bypass diodes within the module encapsulant are presented. The Semicon PN junction diode cells were selected. Diode junction to heat spreader thermal resistance measurements, performed on a variety of mounted diode chip types and sizes, have yielded values which are consistently below 1 deg C per watt, but show some instability when thermally cycled over the temperature range from -40 to 150 deg C. Three representative experimental modules, each incorporating integral bypass diode/heat spreader assemblies of various sizes, were designed. Thermal testing of these modules enabled the formulation of a recommended heat spreader plate sizing relationship. The production cost of three encapsulated bypass diode/heat spreader assemblies were compared with similarly rated externally mounted packaged diodes. It is concluded that, when proper designed and installed, these bypass diode devices will improve the overall reliability of a terrestrial array over a 20 year design lifetime.

Shepard, N. J., Jr.↗

Particulate contaminant relocation during shuttle ascent

The dislodgement, venting, and redeposition of particles on a surface in the shuttle bay by the vibroacoustic, gravitational, and aerodynamic forces present during shuttle ascent have been investigated. The particles of different sizes which are displaced, vented, and redistributed have been calculated; and an estimate of the increased number of particles on certain surfaces and the decrease on others has been indicated. The average sizes, velocities, and length of time for certain particles to leave the bay following initial shuttle doors opening and thermal tests have been calculated based on indirect data obtained during several shuttle flights. Suggestions for future measurements and observations to characterize the particulate environment and the techniques to limit the in-orbit particulate contamination of surfaces and environment have been offered.

Scialdone, J. J.↗

Redistribution of particulates in shuttle bay during launch

The dislodgement, venting, and redeposition of particles on a surface in the shuttle bay by the vibroacoustic, gravitational, and aerodynamic forces present during shuttle ascent were investigated. The particles of different sizes which are displaced, vented, and redistributed were calculated. An estimate of the increased number of particles on certain surfaces and the decrease on others is indicated. The average sizes, velocities, and length of time for certain particles to leave the bay following initial shuttle doors opening and thermal tests were calculated based on indirect data obtained during several shuttle flights.

Scialdone, John J.↗

Integration of symbolic and algorithmic hardware and software for the automation of space station subsystems

Traditional expert systems, such as diagnostic and training systems, interact with users only through a keyboard and screen, and are usually symbolic in nature. Expert systems that require access to data bases, complex simulations and real-time instrumentation have both symbolic as well as algorithmic computing needs. These needs could both be met using a general purpose workstation running both symbolic and algorithmic code, or separate, specialized computers networked together. The latter approach was chosen to implement TEXSYS, the thermal expert system, developed by NASA Ames Research Center in conjunction with Johnson Space Center to demonstrate the ability of an expert system to autonomously monitor the thermal control system of the space station. TEXSYS has been implemented on a Symbolics workstation, and will be linked to a microVAX computer that will control a thermal test bed. This paper will explore the integration options, and present several possible solutions.

Gregg, Hugh↗

Integration of symbolic and algorithmic hardware and software for the automation of space station subsystems

Expert systems that require access to data bases, complex simulations and real time instrumentation have both symbolic as well as algorithmic computing needs. These needs could both be met using a general computing workstation running both symbolic and algorithmic code, or separate, specialized computers networked together. The later approach was chosen to implement TEXSYS, the thermal expert system, developed to demonstrate the ability of an expert system to autonomously control the thermal control system of the space station. TEXSYS has been implemented on a Symbolics workstation, and will be linked to a microVAX computer that will control a thermal test bed. Integration options are explored and several possible solutions are presented.

Gregg, Hugh↗

Integration of symbolic and algorithmic hardware and software for the automation of space station subsystems

Expert systems that require access to data bases, complex simulations and real time instrumentation have both symbolic and algorithmic needs. Both of these needs could be met using a general purpose workstation running both symbolic and algorithmic codes, or separate, specialized computers networked together. The later approach was chosen to implement TEXSYS, the thermal expert system, developed by the NASA Ames Research Center in conjunction with the Johnson Space Center to demonstrate the ability of an expert system to autonomously monitor the thermal control system of the space station. TEXSYS has been implemented on a Symbolics workstation, and will be linked to a microVAX computer that will control a thermal test bed. The integration options and several possible solutions are presented.

Gregg, Hugh↗

Particulate contaminant relocation during shuttle ascent

The dislodgement, venting, and redeposition of particles on a surface in the shuttle bay by the vibroacoustic, gravitational, and aerodynamic forces present during shuttle ascent have been investigated. The particles of different sizes which are displaced, vented, and redistributed have been calculated; and an estimate of the increased number of particles on certain surfaces and the decrease on others has been indicated. The average sizes, velocities, and length of time for certain particles to leave the bay following initial shuttle doors opening and thermal tests have been calculated based on indirect data obtained during several shuttle flights. Suggestions for future measurements and observations to characterize the particulate environment and the techniques to limit the in-orbit particulate contamination of surfaces and environment have been offered.

Scialdone, John J.↗

Carousel deployment mechanism for coilable lattice truss

The development of a mechanism for instrumentation and solar-array deployment is discussed. One part of the technology consists of a smart motor which can operate in either an analog mode to provide high speed and torque, or in the stepper mode to provide accurate positioning. The second technology consists of a coilable lattice mast which is deployed and rotated about its axis with a common drive system. A review of the design and function of the system is presented. Structural and thermal test data are included.

Warden, Robert M.↗

Boundary estimation problems arising in thermal tomography

Problems on the identification of two-dimensional spatial domains arising in the detection and characterization of structural flaws in materials are considered. For a thermal diffusion system with external boundary input, observations of the temperature on the surface are used in a output least squares approach. Parameter estimation techniques based on the method of mappings are discussed and approximation schemes are developed based on a finite element Galerkin approach. Theoretical convergence results for computational techniques are given and the results are applied to experimental data for the identification of flaws in the thermal testing of materials.

Banks, H. T.↗

20 kHz, 25 kVA node power transformer

The electrical and mechanical design information and the electrical and thermal testing performed on the 440-208-V rms, 20-kHz, 25-kVa prototype node transformer are summarized. The calculated efficiency of the node transformer is 99.3 percent based on core loss and copper loss test data, and its maximum calculated load regulation is 0.7 percent. The node transformer has a weight of 19.7 lb and has a power density of 0.8 lb/kW. The hot-spot temperature rise is estimated to be 33 C above the cold plate mounting base. This proof-of-concept transformer design is a viable candidate for the space station Freedom application.

Hussey, S.↗

Determination of the durability of the fiberoptics in rocket engine environments

The results of a testing program in which selected optical fibers were exposed to extreme environments representative of those experienced on rocket engines are discussed. Included in the experiment are cold-bend testing, a moisture embrittlement test, a thermal cycling test, temperature extremes testing, vibration testing, and shock testing. Two of the fibers selected, the titanium-carbide-coated and the aluminum-jacketed silica samples succeeded in passing all the tests without a failure.

Delcher, R.↗

Monolith catalysts for closed-cycle carbon dioxide lasers

The objective was to explore ways of making a monolithic form of catalyst for CO2 lasers. The approach chosen was to pelletize the catalyst material, Au/MnO2 powder, and epoxy the pellets to stainless steel sheets as structural supports. The CO oxidation reaction over Au/MnO2 powder was found to be first overall, and the reaction rate constant at room temperature was 4.4 +/- 0.3 cc/(g x sec). The activation energy was 5.7 kcal/mol. The BET surface area of the pellets was found to vary from 125 to 140 sq m/g between different batches of catalyst. Pellets epoxied to stainless steel strips showed no sign of fracture or dusting when subjected to thermal tests. Pellets can be dropped onto hard surfaces with chipping of edges but no breakage of the pellets. Mechanical strength tests performed on the pellets showed that the crush strength is roughly one-fourth of the pelletizing force. The apparent activity and activation energy over the pellets were found to be less than over the powdered form of the catalyst. The lower apparent activity and activation energy of the pellets are due to the fact that the internal surface area of a pellet is not exposed to the reactant concentration present in the flowing gas as a result of intrapellet diffusion resistance. Effectiveness factors varied from 0.44, for pellets having thickness of 2 mm and attached with epoxy to a stainless steel strip. The epoxy and the stainless steel strip were found to simply block off one of the circular faces of the pellets. The epoxy did not penetrate the pellets and block the active sites. The values of the effective diffusivities were estimated to be between 2.3 x 10(exp -3) and 4.9 x 10(exp -3) sq cm/s. With measurements performed on one powder sample and one pellet configuration, reasonable accurate predictions can be made of conversions that would be obtained with other pellet thickness and configurations.

Herz, Richard K.↗

Structural design and analysis for an ultra low CTE optical bench for the Hubble Space Telescope corrective optics

The stringent stability requirements of the Corrective Optics Space Telescope Axial Replacement (COSTAR) necessitates a Deployable Optical Bench (DOB) with both a low CTE and high resonant frequency. The DOB design consists of a monocoque thin shell structure which marries metallic machined parts with graphite epoxy formed structure. Structural analysis of the DOB has been integrated into the laminate design and optimization process. Also, the structural analytical results are compared with vibration and thermal test data to assess the reliability of the analysis.

Neam, Douglas C.↗

Durability testing of the AJ10-221 490 N high performance (321 sec Isp) engine

The durability of the 490 N AJ10-221 engine is characterized on the basis of data from 93 tests and a total firing life of 6.3 hr. For the three Ir/Re chambers tested, no limiting conditions were encountered in the 43,379 sec and 229 test thermal cycles. A wide range of off nominal operating conditions was successfully demonstrated.

Jassowski, D. M.↗