Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing↗

Application of Distribution Transformer Thermal Life Models to Electrified Vehicle Charging Loads Using Monte-Carlo Method: Preprint

Concentrated purchasing patterns of plug-in vehicles may result in localized distribution transformer overload scenarios. Prolonged periods of transformer overloading causes service life decrements, and in worst-case scenarios, results in tripped thermal relays and residential service outages. This analysis will review distribution transformer load models developed in the IEC 60076 standard, andapply the model to a neighborhood with plug-in hybrids. Residential distribution transformers are sized such that night-time cooling provides thermal recovery from heavy load conditions during the daytime utility peak. It is expected that PHEVs will primarily be charged at night in a residential setting. If not managed properly, some distribution transformers could become overloaded, leading toa reduction in transformer life expectancy, thus increasing costs to utilities and consumers. A Monte-Carlo scheme simulated each day of the year, evaluating 100 load scenarios as it swept through the following variables: number of vehicle per transformer, transformer size, and charging rate. A general method for determining expected transformer aging rate will be developed, based on the energyneeds of plug-in vehicles loading a residential transformer.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Run Time Improvement Efforts for the Roman Space Telescope Thermal Analysis

"Observatory thermal models for large, complex missions, such as the Wide Field InfraRed Survey Telescope (WFIRST) mission, produce an immense amount of data to be processed. Configuration management of the model throughout the project life cycle has mainly focused on which versions of the subsystem models form the current observatory level configuration. However, the results produced by the model are not nearly as well The Roman Space Telescope (RST), formerly known as the Wide Field InfraRed Survey Telescope, is the next great astrophysics observatory mission to follow the James Webb Space Telescope with a planned launch in 2026. As a large scale, flagship mission for NASA with challenging wave front error stability requirements, a single model approach for both thermal discipline analysis and thermo-optical distortion analysis has been used since the early days of the project. In alleviating the need to maintain two separate models for different analysis types, it imposes run time penalties on the thermal analysis with a large model with significant radiation heat exchange. Throughout the lifecycle of the project, the component models have steadily grown in size, resulting in a continuous growth of the overall observatory model with each update and consequently a considerable increase in the model run time. While ongoing efforts to reduce run time are continuously investigated, previous efforts had primarily focused on timestep size and total simulation time to reach quasi-equilibrium. More recently, studies were performed on the total number of radiation couplings (radks) included in the model, which has a nearly linear impact on run time, but increases exponentially with node count. As standard practice for spacecraft analysis, small radks were excluded from the temperature solution based on the assumption that their interchange/view factors have a negligible impact on heat flow. Four approaches were investigated to reduce the model run time while minimizing the impact on accuracy: (1) the Equivalent Radiation Network node, (2) Progressive Radk Inclusion as solution proceeds, (3) Targeted Radk Filtering for critical/non critical areas, and lastly (4) Representation of culled radks with Backloads. Furthermore, the investigation of model run time also revealed that cold cases took noticeably longer to run than hot cases; the root computational inefficiencies were explored along with the computation penalty of linearization of the external radks and recalculation of temperature dependent linear couplings at each timestep. This paper outlines the details of each of the above approaches and their impact on run time and model accuracy.

Thermal Analysis↗

Pion cross section parametrizations for intermediate energy, nucleus-nucleus collisions

Space radiation and cosmic ray transport codes require simple and accurate models for hadron production in intermediate energy, nucleus-nucleus collisions. Several arithmetic parametrization models for pion production are compared to laboratory frame data. It is found that models based on high energy parametrizations are unable to describe intermediate energy, differential cross section data. However, simple thermal model parametrizations, when appropriately transformed from the center of momentum to the laboratory frame, are able to account for the data. Heavy ion transport codes that require algebraic cross section formulas can therefore use arithmetic parametrizations at high energy, but should use thermal model parametrizations at intermediate energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental characterization and modeling of thermal resistance of electric machine lamination stacks

There is lack of information in the open literature on thermal properties of electric machine lamination stacks such as contact resistance and effective thermal conductivity, yet this information is critical for researchers and engineers in electric machine design and development. The thermal conductivity of electromagnetic steel lamination materials was measured, and the thermal contact resistance between laminations in a stack, as well as factors affecting contact resistance between laminations - such as the contact pressure and surface finish - were investigated. A model was also developed to estimate the through-stack thermal conductivity for materials beyond those that were directly tested in this work. Four lamination materials were investigated, including the commonly-used 26-gauge and 29-gauge M19 materials, the HF10, and Arnon 7 materials. Although this paper focuses on electric machines for automotive applications, the information is potentially applicable to any component utilizing electromagnetic steel laminations.

30 DIRECT ENERGY CONVERSION↗

Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. Furthermore, the results were compared to currently available models for contact resistance, and one model was adapted for prediction of TCR in future motor designs.

30 DIRECT ENERGY CONVERSION↗

Thermal Analysis of Refueling Propellant Systems for PPE

To support the sustainability of Gateway, approach the challenge of sustainable presence beyond low earth orbit, and provide proving grounds for future missions beyond the surface of the moon, refueling capabilities must be incorporated into Gateway. The objective is to replenish propellants into the Power and Propulsion Element (PPE) from the European System Providing Refueling, Infrastructure and Telecommunications (ESPIRIT) through the Habitation and logistics outpost (HALO). PPE refueling will consist of a bipropellant transfer system, as well as a main propellant transfer system. Refueling the Power and Propulsion Element in near rectilinear halo orbit can present various issues, and to thermally maintain the refueling system during this event requires diligent planning and thermal design. Presently, a thermal model exists to analyze the components of the refueling system as the development of PPE continues. The analysis from the thermal model will verify the integrity of the all the components during a refueling event throughout the duration of the mission given various environmental differences. To confidently refuel PPE, thermal analysis, and various tests of the refueling components, must be completed to achieve the desired sustainability of Gateway.

Ethan Sparks↗

Heat Generation versus Heat Dissipation Maps for Batteries (Battery Safety Maps) [SWR-21-27]

NREL's Battery Safety Map (Heat Generation versus Heat Dissipation Maps for Batteries) generates a response surface that is grouped into regions where the battery is deemed safe from the propagation of thermal runaway, those where an engineering solution would render the battery safe, and finally instances where thermal runaway is inevitable. The demarcation for the different regions is provided by specifications or constraints imposed by the end user. NREL's Battery Safety Map is a user-defined subroutine that sweeps through a set of parameters describing the operating conditions and short-circuit scenarios for battery safety simulations. For each run, the electrochemical-thermal model implementing reaction kinetics and gas generation are run to evaluate the amount of heat generated. A thermal model then captures the amount of heat dissipation based on boundary conditions defined (e.g., forced convection, constant temperature at the surface, etc.). Based on the rate of heat transfer and the amount of heat generated, each run is classified into "safe," "mitigation possible," or "unsafe" zones. These categories are defined based on constraints or tolerance specifications provided by the end user.

Santhanagopalan, Shriram↗

Thermal Fault Tolerance Analysis of Carbon Fiber Rope Barrier Systems for Use in the Reusable Solid Rocket Motor ( RSRM) Nozzle Joints

Carbon Fiber Rope (CFR) thermal barrier systems are being considered for use in several RSRM (Reusable Solid Rocket Motor) nozzle joints as a replacement for the current assembly gap close-out process/design. This study provides for development and test verification of analysis methods used for flow-thermal modeling of a CFR thermal barrier subject to fault conditions such as rope combustion gas blow-by and CFR splice failure. Global model development is based on a 1-D (one dimensional) transient volume filling approach where the flow conditions are calculated as a function of internal 'pipe' and porous media 'Darcy' flow correlations. Combustion gas flow rates are calculated for the CFR on a per-linear inch basis and solved simultaneously with a detailed thermal-gas dynamic model of a local region of gas blow by (or splice fault). Effects of gas compressibility, friction and heat transfer are accounted for the model. Computational Fluid Dynamic (CFD) solutions of the fault regions are used to characterize the local flow field, quantify the amount of free jet spreading and assist in the determination of impingement film coefficients on the nozzle housings. Gas to wall heat transfer is simulated by a large thermal finite element grid of the local structure. The employed numerical technique loosely couples the FE (Finite Element) solution with the gas dynamics solution of the faulted region. All free constants that appear in the governing equations are calibrated by hot fire sub-scale test. The calibrated model is used to make flight predictions using motor aft end environments and timelines. Model results indicate that CFR barrier systems provide a near 'vented joint' style of pressurization. Hypothetical fault conditions considered in this study (blow by, splice defect) are relatively benign in terms of overall heating to nozzle metal housing structures.

Clayton, J. Louie↗

Thermal study of interface between the Orbiter cold plate and typical Shuttle spacecraft payload flight electronics

Spacelab provides a set of Freon line plumbing and cold plates for experiment equipments which are located in the Shuttle pallet and which need active thermal control. The reported study deals with the thermal problem of attaching a Command and Data Handling module with various electronic boxes whose combined footprints on the baseplate are much larger than the cold plate. A description of two modules and the cold plate assembly in the pallet is presented and a thermal model description is provided. The method employed in modeling heat pipes-honey-comb matrix is based upon an effective conductance between the heat pipe vapor and the walls of the heat pipe. The considered thermal models and a computer program are used to perform steady-state thermal analyses. The temperature gradients in the large module baseplate attached to the small cold plate are predicted as a function of the interface plate thickness.

Hwangbo, H.↗

Quasi-Determinate Model of Thermal Phenomena in Drilling Laminates

Assessment of thermal phenomena in the drilling of laminates is critical in printed-circuit production. A quasi-determinate model permits calculation of the expected temperature in the cutting zone during the drilling of small mounting sockets and pass-through holes, with consequent decrease in manufacturing waste.

42 ENGINEERING↗

Accuracy and Efficiency of a Coupled Neutronics and Thermal Hydraulics Model

The accuracy requirements for modern nuclear reactor simulation are steadily increasing due to the cost and regulation of relevant experimental facilities. Because of the increase in the cost of experiments and the decrease in the cost of simulation, simulation will play a much larger role in the design and licensing of new nuclear reactors. Fortunately as the work load of simulation increases, there are better physics models, new numerical techniques, and more powerful computer hardware that will enable modern simulation codes to handle this larger workload. This manuscript will discuss a numerical method where the six equations of two-phase flow, the solid conduction equations, and the two equations that describe neutron diffusion and precursor concentration are solved together in a tightly coupled, nonlinear fashion for a simplified model of a nuclear reactor core. This approach has two important advantages. The first advantage is a higher level of accuracy. Because the equations are solved together in a single nonlinear system, the solution is more accurate than the traditional “operator split” approach where the two-phase flow equations are solved first, the heat conduction is solved second and the neutron diffusion is solved third, limiting the temporal accuracy to 1st order because the nonlinear coupling between the physics is handled explicitly. The second advantage of the method described in this manuscript is that the time step control in the fully implicit system can be based on the timescale of the solution rather than a stability-based time step restriction like the material Courant. Results are presented from a simulated control rod movement and a rod ejection that address temporal accuracy for the fully coupled solution and demonstrate how the fastest timescale of the problem can change between the state variables of neutronics, conduction and two-phase flow during the course of a transient.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Photoelastic tests on models of thermal protection system for space shuttle orbiter

The thermal protection system (TPS) of the space shuttle orbiter vehicle, consisting of ceramic tile/adhesive/strain isolator pad/adhesive/aluminum substructure, was modeled photoelasticity. A highly sensitive photoelastic material was used in the models to show the nature of the stress-transfer between the strain isolation pad (SIP) and the ceramic tile through the RTV-adhesive layer. Isochromatic fringe patterns were obtained for models subjected to tension and combined tension and bending. Tests indicated that the load-transfer between the SIP and the photoelastic material occurred at discrete locations causing stress concentrations in the photoelastic material. Stress concentration factors of the order of 1.9 were measured, but as the observed photoelastic response was an integrated effect through the model thickness, the local stress concentration factors at the SIP/tile interface could be even higher.

Prabhakaran, R.↗

The interpretation of hard X-ray polarization measurements in solar flares

The significance of low hard X-ray polarization measurements for non-thermal models is discussed. Such a low polarization result, it is shown, can in fact occur in non-thermal models, and the ways in which the degree of X-ray polarization is correlated with the parameters of these models is discussed.

Leach, J.↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗