Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Technology Solutions Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction

Fire-resistance rated (or area separation) wall assemblies present a great difficulty in air sealing/compartmentalization, particularly in townhouse construction. To address this challenge, Building Science Corporation partnered with builder K. Hovnanian Homes to determine whether taping exterior sheathing details improves air sealing in townhouse and multifamily construction, and to better understand air leakage pathways.

air leakage↗

In aqua vivo EPID dosimetry

Purpose: At the Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the original back-projection dose-reconstruction algorithm uses water-based scatter-correction kernels and therefore does not account for tissue inhomogeneities accurately. The aim of this study was to test a new method, in aqua vivo EPID dosimetry, for fast dose verification of lung cancer irradiations during actual patient treatment. Methods: The key feature of our method is the dose reconstruction in the patient from EPID images, obtained during the actual treatment, whereby the images have been converted to a situation as if the patient consisted entirely of water; hence, the method is termed in aqua vivo. This is done by multiplying the measured in vivo EPID image with the ratio of two digitally reconstructed transmission images for the unit-density and inhomogeneous tissue situation. For dose verification, a comparison is made with the calculated dose distribution with the inhomogeneity correction switched off. IMRT treatment verification is performed for each beam in 2D using a 2D {gamma} evaluation, while for the verification of volumetric-modulated arc therapy (VMAT) treatments in 3D a 3D {gamma} evaluation is applied using the same parameters (3%, 3 mm). The method was tested using two inhomogeneous phantoms simulating a tumor in lung and measuring its sensitivity for patient positioning errors. Subsequently five IMRT and five VMAT clinical lung cancer treatments were investigated, using both the conventional back-projection algorithm and the in aqua vivo method. The verification results of the in aqua vivo method were statistically analyzed for 751 lung cancer patients treated with IMRT and 50 lung cancer patients treated with VMAT. Results: The improvements by applying the in aqua vivo approach are considerable. The percentage of {gamma} values {<=}1 increased on average from 66.2% to 93.1% and from 43.6% to 97.5% for the IMRT and VMAT cases, respectively. The corresponding mean {gamma} value decreased from 0.99 to 0.43 for the IMRT cases and from 1.71 to 0.40 for the VMAT cases, which is similar to the accepted clinical values for the verification of IMRT treatments of prostate, rectum, and head-and-neck cancers. The deviation between the reconstructed and planned dose at the isocenter diminished on average from 5.3% to 0.5% for the VMAT patients and was almost the same, within 1%, for the IMRT cases. The in aqua vivo verification results for IMRT and VMAT treatments of a large group of patients had a mean {gamma} of approximately 0.5, a percentage of {gamma} values {<=}1 larger than 89%, and a difference of the isocenter dose value less than 1%. Conclusions: With the in aqua vivo approach for the verification of lung cancer treatments (IMRT and VMAT), we can achieve results with the same accuracy as obtained during in vivo EPID dosimetry of sites without large inhomogeneities.

61 RADIATION PROTECTION AND DOSIMETRY↗

SLUG-STOCHASTICALLY LIGHTING UP GALAXIES. I. METHODS AND VALIDATING TESTS

The effects of stochasticity on the luminosities of stellar populations are an often neglected but crucial element for understanding populations in the low-mass or the low star formation rate regime. To address this issue, we present SLUG, a new code to 'Stochastically Light Up Galaxies'. SLUG synthesizes stellar populations using a Monte Carlo technique that properly treats stochastic sampling including the effects of clustering, the stellar initial mass function, star formation history, stellar evolution, and cluster disruption. This code produces many useful outputs, including (1) catalogs of star clusters and their properties such as their stellar initial mass distributions and their photometric properties in a variety of filters, (2) two dimensional histograms of color-magnitude diagrams of every star in the simulation, and (3) the photometric properties of field stars and the integrated photometry of the entire simulated galaxy. After presenting the SLUG algorithm in detail, we validate the code through comparisons with STARBURST99 in the well-sampled regime, and with observed photometry of Milky Way clusters. Finally, we demonstrate SLUG's capabilities by presenting outputs in the stochastic regime. SLUG is publicly distributed through the Web site http://sites.google.com/site/runslug/.

79 ASTRONOMY AND ASTROPHYSICS↗

Chapter 8 - Testing and Evaluation Methods for Protection Systems

In this chapter, we aim to present different approaches used formally and informally for the evaluation of protection devices and schemes. This chapter starts with presenting background on generalization of protection device components, followed by the resources necessary to evaluate the protection system. Further, this chapter presents the different approaches used in protection evaluation with their advantages and disadvantages. Finally, this chapter closes by presenting background on technology readiness level metrics. Technology readiness level metric is borrowed from the space industry for the purpose of comparing the maturity of the different protection technologies and using the appropriate evaluation methods from the list presented here.

power systems↗

Infrared imaging diagnostics for intense pulsed electron beam

Infrared imaging diagnostic method for two-dimensional calorimetric diagnostics has been developed for intense pulsed electron beam (IPEB). By using a 100-μm-thick tungsten film as the infrared heat sink for IPEB, the emitting uniformity of the electron source can be analyzed to evaluate the efficiency and stability of the diode system. Two-dimensional axisymmetric finite element method heat transfer simulation, combined with Monte Carlo calculation, was performed for error estimation and optimization of the method. The test of the method was finished with IPEB generated by explosive emission electron diode with pulse duration (FWHM) of 80 ns, electron energy up to 450 keV, and a total beam current of over 1 kA. The results showed that it is possible to measure the cross-sectional energy density distribution of IPEB with energy sensitivity of 0.1 J/cm{sup 2} and spatial resolution of 1 mm. The technical details, such as irradiation protection of bremsstrahlung γ photons and the functional extensibility of the method were discussed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Hilbert space on a budget: Novel benchmark set and performance metric for testing electronic structure methods in the regime of strong correlation

This work explores the ability of classical electronic structure methods to efficiently represent (compress) the information content of full configuration interaction (FCI) wave functions. We introduce a benchmark set of four hydrogen model systems of different dimensionalities and distinctive electronic structures: a 1D chain, a 1D ring, a 2D triangular lattice, and a 3D close-packed pyramid. To assess the ability of a computational method to produce accurate and compact wave functions, we introduce the accuracy volume, a metric that measures the number of variational parameters necessary to achieve a target energy error. Using this metric and the hydrogen models, we examine the performance of three classical deterministic methods: (i) selected configuration interaction (sCI) realized both via an a posteriori (ap-sCI) and variational selection of the most important determinants, (ii) an a posteriori singular value decomposition (SVD) of the FCI tensor (SVD-FCI), and (iii) the matrix product state representation obtained via the density matrix renormalization group (DMRG). We find that the DMRG generally gives the most efficient wave function representation for all systems, particularly in the 1D chain with a localized basis. For the 2D and 3D systems, all methods (except DMRG) perform best with a delocalized basis, and the efficiency of sCI and SVD-FCI is closer to that of DMRG. For larger analogs of the models, the DMRG consistently requires the fewest parameters but still scales exponentially in 2D and 3D systems, and the performance of SVD-FCI is essentially equivalent to that of ap-sCI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A REFINED QSO SELECTION METHOD USING DIAGNOSTICS TESTS: 663 QSO CANDIDATES IN THE LARGE MAGELLANIC CLOUD

We present 663 QSO candidates in the Large Magellanic Cloud (LMC) selected using multiple diagnostics. We started with a set of 2566 QSO candidates selected using the methodology presented in our previous work based on time variability of the MACHO LMC light curves. We then obtained additional information for the candidates by crossmatching them with the Spitzer SAGE, the Two Micron All Sky Survey, the Chandra, the XMM, and an LMC UBVI catalog. Using this information, we specified six diagnostic features based on mid-IR colors, photometric redshifts using spectral energy distribution template fitting, and X-ray luminosities in order to further discriminate high-confidence QSO candidates in the absence of spectra information. We then trained a one-class Support Vector Machine model using the diagnostics features of the confirmed 58 MACHO QSOs. We applied the trained model to the original candidates and finally selected 663 high-confidence QSO candidates. Furthermore, we crossmatched these 663 QSO candidates with the newly confirmed 151 QSOs and 275 non-QSOs in the LMC fields. On the basis of the counterpart analysis, we found that the false positive rate is less than 1%.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods and stability tests associated with the sterile neutrino search using improved high-energy ν μ event reconstruction in IceCube

We provide supporting details for the search for a 3 + 1 sterile neutrino using data collected over 10.7 years at the IceCube Neutrino Observatory. The analysis uses atmospheric muon-flavored neutrinos from 0.5 to 100 TeV that traverse Earth to reach the IceCube detector and finds a best-fit point at sin 2 ( 2 θ 24 ) = 0.16 and Δ m 41 2 = 3.5 eV 2 with a goodness-of-fit p value of 12% and consistency with the null hypothesis of no oscillations to sterile neutrinos with a p value of 3.1%. Several improvements were made over past analyses, which are reviewed in this article, including upgrades to the reconstruction and the study of sources of systematic uncertainty. We provide details of the fit quality and discuss stability tests that split the data for separate samples, comparing results. We find that the fits are consistent between split datasets. Published by the American Physical Society 2024

Abbasi, R.↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-271: Direct Measurement of Tenth Value Layer Thicknesses for High Density Concretes with a Clinical Machine

Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFF on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

43 PARTICLE ACCELERATORS↗

Comparison of Statistical Methods for Detector Testing Programs

A typical goal for any detector testing program is to ascertain not only the performance of the detector systems under test, but also the confidence that systems accepted using that testing program’s acceptance criteria will exceed a minimum acceptable performance (which is usually expressed as the minimum acceptable success probability, p). A similar problem often arises in statistics, where we would like to ascertain the fraction, p, of a population of items that possess a property that may take one of two possible values. Typically, the problem is approached by drawing a fixed sample of size n, with the number of items out of n that possess the desired property, x, being termed successes. The sample mean gives an estimate of the population mean p ≈ x/n, although usually it is desirable to accompany such an estimate with a statement concerning the range within which p may fall and the confidence associated with that range. Procedures for establishing such ranges and confidence limits are described in detail by Clopper, Brown, and Agresti for two-sided symmetric confidence intervals.

97 MATHEMATICS AND COMPUTING↗

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving and testing machine learning methods for benchmarking soil carbon dynamics representation of land surface models

Representation of soil organic carbon (SOC) dynamics in Earth system models (ESMs) is a key source of uncertainty in predicting carbon climate feedbacks. The magnitude of this uncertainty can be reduced by accurate representation of environmental controllers of SOC stocks in ESMs. In this study, we used data of environmental factors, field SOC observations, ESM projections and machine learning approaches to identify dominant environmental controllers of SOC stocks and derive functional relationships between environmental factors and SOC stocks. Our derived functional relationships predicted SOC stocks with similar accuracy as the machine learning approach. We used the derived relationships to benchmark the coupled model intercomparison project phase six ESM representation of SOC stocks. We found divergent environmental control representation in ESMs in comparison to field observations. Representation of SOC in ESMs can be improved by including additional environmental factors and representing their functional relationships with SOC consistent with observations.

54 ENVIRONMENTAL SCIENCES↗

Experimental Demonstration of Alkalinity Concentration Swing for Direct Air Capture of CO 2

This work constitutes the first lab-scale experimental demonstration of the alkalinity concentration swing (ACS) for direct air capture (DAC) of CO 2 . ACS can be implemented by taking a dilute alkaline solution that has contacted ambient air, and then concentrating it using commercially available desalination technologies. The more concentrated solution has a higher partial pressure of CO 2 relative to the initial solution, allowing the CO 2 to be separated and stored. The ACS approach is based on simple thermodynamics but had never been verified experimentally in terms of extracting CO 2 from air until now. We tested two distinct methods for concentrating the alkaline liquid: reverse osmosis (RO) and capacitive deionization (CDI). We found that to complete the DAC cycle in feasible operating conditions, a bicarbonate-enrichment step needed to be introduced, which selects on bicarbonate ions over carbonate ions. Two approaches for CO 2 extraction to measure the CO 2 yield per amount of water processed by the ACS method were tested. The energy required per amount of CO 2 captured was quantified. We further applied an energy model to study how operating the ACS cycle under different conditions would affect energy requirements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical and Performance-Based Evaluation Alternatives to Full-Scope, High-Fidelity Testbeds

One consequence the design and operational differences of advanced reactors is that integrated system validation (ISV) using full-scope, high-fidelity testbed might not be cost-justified or practical. The absence of traditional ISV may pose an issue for the conduct of safety evaluations since it may leave regulators without the information derived from this performance-based testing. The purpose of this research is to identify analytical and performance-based test and evaluation methods that are alternatives to full-scope, high-fidelity testbeds that have traditionally been used for ISV. We developed a method to test validation based on a multi-stage validation (MSV) framework. MSV is an approach to meeting validation objectives through incremental, successive validation activities beginning in the early stages of the design process and continuing through the later stages. MSV doesn't rely solely on late stage validation, rather it accommodates the use of a broad spectrum of analytical and performance-based information and a diversity of testbeds. In addition, MSV embraces the use of information from other types of evaluations and analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Apparatus and method for fatigue testing of a material specimen in a high-pressure fluid environment

The invention provides fatigue testing of a material specimen while the specimen is disposed in a high pressure fluid environment. A specimen is placed between receivers in an end cap of a vessel and a piston that is moveable within the vessel. Pressurized fluid is provided to compression and tension chambers defined between the piston and the vessel. When the pressure in the compression chamber is greater than the pressure in the tension chamber, the specimen is subjected to a compression force. When the pressure in the tension chamber is greater than the pressure in the compression chamber, the specimen is subjected to a tension force. While the specimen is subjected to either force, it is also surrounded by the pressurized fluid in the tension chamber. In some examples, the specimen is surrounded by hydrogen.

36 MATERIALS SCIENCE↗