Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRACER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Results of Chemical Analyses in Support of Yucca Mountain Studies

Ground water monitoring for the Nye County Early Warning Drilling Program (NCEWDP) was established to monitor underground water sources of the area and to protect communities surrounding the Nevada Test Site (NTS) from potential radionuclide contamination of these water sources. It provides hydrological information pertaining to groundwater flow patterns and recharge issues in the vicinity of Yucca Mountain. The Harry Reid Center for Environmental Studies (HRC) obtained groundwater samples from select NCEWDP wells shown in Figure 1. These samples were analyzed for major cations, major anions, trace elements, rare earth elements, alkalinity, pH and conductivity. These geochemical results can be used to evaluate the degree of interaction between the aquifers sampled, leading to a thorough mapping of the aquifer system. With increased analysis down gradient of the Yucca Mountain area, evaluations can identify viable groundwater flow paths and establish mixing of the groundwater systems. Tracer tests provide insight into groundwater flow characteristics and transport processes of potential contaminants. These tests are important for contaminant migration issues including safe disposal of hazardous and radioactive materials and remediation of potentially released contaminants. At a minimum, two conservative (non-sorbing) tracers with different diffusion coefficients are used for each tracer test. The tracer test performed under this cooperative agreement utilized fluorinated benzoic acids and halides as conservative tracers. The tracers are of differing size and have differing rates of diffusion into the rock. Larger molecules can not enter the pore spaces that are penetrated by the smaller molecules, therefore larger tracers will travel faster through thegroundwater system. Identical responses of the two tracers indicate no appreciable diffusion into pores of the aquifer system tuff. For the Nye County Tracer Tests, the HRC provided chemical analysis for the tracer test being conducted at site 22. Samples were analyzed for multiple tracers throughout the testing period.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the local influence at a tall tower site in nocturnal conditions

The influence of the local terrestrial environment on nocturnal atmospheric CO 2 measurements at a 329-m television transmitter tower (and a component of a CO 2 monitoring network) was estimated in this paper with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released on two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO 2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. Finally, the contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.

54 ENVIRONMENTAL SCIENCES↗

Chemical Tool Peer Review Summary.

Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoir by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NMED Correspondence Related to Notice of Intent for Chromium Project

Two methods of injection using a solution containing 50 kilograms (kg) of tracer are proposed for each well. Half of the tracer (25 kg) may be mixed with 3,000 gallons of potable water and delivered into a scheduled injection stream of treated groundwater as permitted in OP-1835 over a five to seven-hour period. This procedure would then be repeated on a consecutive second day. Alternatively, 5 kg of tracer may be added to each of ten 3,000-gallon tanks for a total of 30,000 gallons of tracer solution that may be injected independently of other injection flow over a period of up to five days. The permittees request that the types and masses of tracers that may be utilized per each injection well remain flexible enough to allow for one or more of the naphthalene sulfonate tracers to be substituted with a different naphthalene sulfonate. This need for flexibility is due to the availability of the tracers and any tracer listed that is designated for a given CrIN well may be interchanged with a tracer that is designated for another CrIN well, pending final NMED approval. The permittees are not allowed to introduce any new tracers and will submit a final work plan prior to each injection for each CrIN well.

54 ENVIRONMENTAL SCIENCES↗

Editorial

To address the need for additional high-resolution urban dispersion data sets, the U.S. Departments of Defense, Energy and Homeland Security joined together to fund the Joint Urban 2003 (JU03) atmospheric dispersion study. This major urban study was conducted from June 28 through July 31, 2003, in Oklahoma City, Oklahoma, with the participation of over 150 scientists and engineers from over 20 U.S. and foreign institutions. Through mid-2006 over 125 papers and presentations have been given on scientific findings and model evaluations based on the field study results. The official JU03 data archive is accessible through the internet by requesting an account at https://ju2003-dpg.dpg.army.mil/. The JU03 study included several integrated scientific components necessary to describe and understand the physical processes governing dispersion within and surrounding an urban area and into and within building environments. These components included characterizing: 1) the urban boundary layer; 2) flows within a street canyon, including the effects of traffic on turbulence; 3) flows within and downwind of the tall-building core; 4) the surface energy balance within an urban area; 5) dispersion of tracer into, out of, and within buildings; and 6) dispersion of tracer throughout the downtown core and out to four kilometers downwind from the release. The scientific elements of the study were accomplished using state-of-the-art meteorological and tracer instruments, including lidars, sodars, radars, sonic anemometers, airplane-based meteorological sensors, fast-response tracer analyzers, and helicopter-based remote tracer detectors. Winds and other meteorological quantities were measured continuously at nearly 100 locations in and around downtown OKC. Tracer was released on 10 days during the experiment period and included both puff and continuous releases. The tracer was sampled using over 200 integrated samplers and 25 fast response analyzers. Vertical measurements of tracer were made by placing samplers on the tops of nearly 20 buildings and by sampling tracer at seven levels on a 90-m crane. The twelve papers in this special issue provide a cross-section of the scientific investigations pursued using JU03 data. Half the papers focus on using observations to characterize winds, turbulence and dispersion in the boundary layer above the city and into a downtown Oklahoma City street canyon (Park Avenue). The remaining papers discuss model evaluations using JU03 data and our improved understanding of processes governing dispersion in urban areas using models and observations. The combination of a dense network of measurements with state-of-the-art instruments allowed for an unparalleled investigation of transport and diffusion in an urban environment. We expect the Joint Urban 2003 data set will be used for many years for model development and validation efforts, and for refining our understanding of flow and dispersion in urban areas including the exchange of contaminants between outdoor and indoor and environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteria for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.

3410 building↗

Validation Data Acquisition in HTTF during PCC Events

A validation experimental campaign was conducted in an Integral Effect Test (IET) facility of High Temperature Gas Reactors (HTGR), the High-Temperature Test Facility (HTTF) at Oregon State University (OSU). The HTTF simulates Depressurized and Pressurized Conduction Cooldowns (DCC and PCC). This campaign required the development of a new laser spectroscopic diagnostic to measure velocity in the challenging conditions of the HTTF: low speed (~1 m/s) gas flows at HTGR prototypical temperature and 1/10th pressure. This was a collaborative effort between co-PIs at The George Washington University (GW), Oregon State University (OSU), and NASA Langley Research Center. The main accomplishments of this project include the record for dynamic range for velocimetry, highest accuracy obtained with this technique, successful deployment in an IET leading to new validation matrix for CFD. These are detailed below and in manuscript appended to this executive summary. For this project, we introduced a new class of laser spectroscopic diagnostics to Thermal-Hydraulics to measure velocity of gases; furthermore, the diagnostic was demonstrated in-situ in an IET during DCC events. In such scenarios, particles used in mainstream techniques, like Particle Image Velocimetry (PIV) are not appropriate as they settle down too rapidly and also contaminate the experimental facility. Molecular tracers stay mixed within the working gas and can seed the flow in a technique called Molecular Tagging Velocimetry (MTV). In MTV a molecular tracer is photo-dissociated by a first (write) laser into radicals or molecules. The pattern created by the write laser is then interrogated with planar laser-induced fluorescence (PLIF), the read pulse(s), which are recorded with a camera. The pattern is probed and matched at two times (interval or probe time, dt), resulting in a time-of-flight velocimetry technique. This project demonstrated a new application range for MTV in gases. MTV has been extensively used for high-speed gas dynamics: molecules do not suffer from inertia associated with particles in regions of high accelerations (such as shock waves). For high-speed flows, the probe time is on the order of 0.1-10 µs. In time-of-flight techniques, the velocity is reconstructed from the recorded displacement, dx, between time interval dt: U = dx/dt. To first order, the resolution of the pattern matching is typically a (fixed) fraction of a pixel; therefore the resolution of the velocity measurement increases with dx and, for a given flow velocity, dt. For the low-speed flows of interest here, this requires long probe time, and therefore finding tracers that are stable for a long time. After an extensive literature survey we identified 6 tracers that would be suitable. We also worked with Spectra Physics to design a custom laser system that is flexible enough to probe these various tracers. The final instrument is made of 4 lasers that are integrated into a compact and movable cart to facilitate the deployment of the instrument off-site. One unique aspect of the laser system is the tunable dye laser (needed to do PLIF of the radicals). By being pumped by two Nd:YAG lasers, this laser is able to provide two pulses with any probe time (dt) for wavelengths between 200 and 900 nm with a linewidth of 3 pm. Accommodating the dual-pulse capability required customizing the pump lasers and the dye laser, making this system unique. Additionally, a custom UV-intensified CCD camera capable of frame-straddling and exposure time as short as 10 ns was acquired. More than two-third of the instrument cost (~$200k) was covered by a cost sharing from the PI’s startup funds. Of the 6 potential tracers identified, two were tested extensively (H2O and N2O) at high-temperature and elevated pressure at GW prior to conducting the tests at OSU. For both tracers, an Ar-F laser (193 nm, 10 ns, 10 mJ/pulse) photo-dissociates trace amounts (0.1 – 5% molar fraction) of the gases into OH and NO. OH is probed at 281.905 nm and NO at 226.186 nm (4-30mJ, 10 ns pulse). NO is very stable in inert environment and we could reconstruct velocities precisely with probe delay times as long at 40 ms, compared to 2 ms for OH, resulting in increased precision. Therefore, for the tests in the HTTF, N2O was selected as the final tracer and its optimal concentration was determined to be 0.5% molar. In the GW laboratory, we obtained a velocity measurement precision of 4 mm/s at conditions mimicking the HTTF tests. We also demonstrated the benefit of molecular tracers over particles and the flexibility of our instrument by continuously measuring velocity from 1000 to 0.1 m/s in a blow down test. This represents a dynamic range on velocity of 80 dB, which is unprecedented for velocimetry! Once the diagnostic was optimized, two two-week campaigns were conducted in the HTTF. This experimental campaign required numerous practical solutions to successfully and rapidly deploy this very sensitive table-top diagnostic in-situ. This was accomplished thanks to very extensive planning from all parties involved in the project. Due to constraints on availability of the HTTF, only adiabatic DCC tests were conducted. Specifically, the velocity was measured at the exit of the hot leg into the Reactor Cavity Simulation Tank (RCST). We were able to record the gas velocity associated with the air ingress for long times (up to one hour). Depending on the initial conditions (density of the gases in the Reactor Pressure Vessel and the RCST) the lock exchange lasted 30-60 s past the valve openings. Large vortices were identified within the shear layer at the interface of the cross flow. These vortices are an indication of shear-driven instability between the counter streams of different density. After the lock-exchange, a small residual flow was still present and its strength decayed exponentially. It finds its source in a buoyancy difference between the gases in both vessels due to the mixing and diffusion of the gases in the cross-over duct and the RPV lower plenum. We did not expect to capture this part of the transient, which would have been less significant (if not negligible) in the presence of a heated core; the precision of our measurement in the HTTF was 6 mm/s, which exceeded our expectations for such a complex test! Using commercial software (Fluent) we simulated the experiment with Computational Fluid Dynamic (CFD) using Reynolds Averaged Navier-Stokes (RANS) turbulence models. We were not able to accurately reproduce the shear layer instability, mixing, and diffusion captured in our experimental data, even with large 3D meshes (>10 M points). We attributed this to the inadequacy of the RANS models for the flow of interest: our experimental Reynolds number was too low and was outside the applicability range of the RANS models. Instead, we should have employed CFD with less modeling, such as Large Eddy (LES) or even Direct Numerical (DNS) simulations. Unfortunately, we did not have the computational resources to do so. Finally, it should be noted that this experimental technique holds great promises for measuring velocity in thermalhydraulics. MTV has an application domain (highlighted in the narrative) that is complimentary to more established (and simpler) techniques, such as PIV. It has attracted the attention of several thermalhydraulics researchers and sponsors to measure velocity in harsh environments. The spectroscopic nature of this technique also enables to expand it to measure temperature and concentration simultaneously to velocity. In lieu of a narrative, 4 detailed journal publications are appended to this executive summary to describe the various development and accomplishments during this project. They include 2 published manuscripts (Experiments in Fluids and Measurement Science and Technology), and two invited contributions following the NURETH-17 conference (Nuclear Science and Technology). Our current Nuclear Engineering and Design draft is not included at this time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effect of wind and currents on gas exchange in an estuarine system

The objectives were to develop a non-volatile tracer to use in gas exchange experiments in laterally unconfined systems and to study applications of deliberate tracers in limnology and oceanography. Progress was made on both fronts but work on the development of the non-volatile tracer proved to be more difficult and labor intensive that anticipated so no field experiments using non-volatile tracers was performed as yet. In the search for a suitable non-volatile tracer for an ocean scale gas exchange experiment a tracer was discovered which does not have the required sensitivity for a large scale experiment, but is very easy to analyze and will be well suited for smaller experiments such as gas exchange determinations on rivers and streams. Sulfur hexafluoride, SF6, was used successfully as a volatile tracer along with tritium as a non-volatile tracer to study gas exchange rates from a primary stream. This is the first gas exchange experiment in which gas exchange rates were determined on a head water stream where significant groundwater input occurs along the reach. In conjunction with SF6, Radon-222 measurements were performed on the groundwater and in the stream. The feasibility of using a combination of SF6 and radon is being studied to determine groundwater inputs and gas exchange of rates in streams with significant groundwater input without using a non-volatile tracer.

Broecker, W. S.↗

RCUT: A Non-Invasive Method for Detection, Location, and Quantification of Radiological Contaminants in Pipes and Ducts - 12514

Radiological Characterization Using Tracers (RCUT) is a minimally invasive method for detection and location of residual radiological contamination in pipes and ducts. The RCUT technology utilizes reactive gaseous tracers that dissociate when exposed to gamma and/or beta radiation emitting from a radiological contaminant in a pipe or duct. Sulfur hexafluoride (SF{sub 6}) was selected as a tracer for this radiological application, because it is a chemically inert gas that is both nonflammable, nontoxic, and breaks down when exposed to gamma radiation. Laboratory tests demonstrated that the tracer pair of SF{sub 6} and O{sub 2} formed SO{sub 2}F{sub 2} when exposed to a gamma or beta radioactive field, which indicated the presence of radiological contamination. Field application of RCUT involves first injecting the reactive tracers into the pipe to fill the pipe being inspected and allowing sufficient time for the tracer to interact with any contaminants present. This is followed by the injection of an inert gas at one end of the pipe to push the reactive tracer at a known or constant flow velocity along the pipe and then out the exit and sampling port at the end of the pipeline where its concentration is measured by a gas chromatograph. If a radiological contaminant is present in the pipe being tested, the presence of SO{sub 2}F{sub 2} will be detected. The time of arrival of the SO{sub 2}F{sub 2} can be used to locate the contaminant. If the pipe is free of radiological contamination, no SO{sub 2}F{sub 2} will be detected. RCUT and PCUT are both effective technologies that can be used to detect contamination within pipelines without the need for mechanical or human inspection. These methods can be used to detect, locate, and/or estimate the volume of a variety of radioactive materials and hazardous chemicals such as chlorinated solvents, petroleum products, and heavy metals. While further optimization is needed for RCUT, the key first step of identification of a tracer compound appropriate for the application of detecting radioactive pipeline contamination through the detection of decomposition products of SF{sub 6} has been demonstrated. Other tracer gases that will also undergo radiolysis will be considered in the future. The next step for the RCUT development process is conducting laboratory scale tests using short pipelines to define analytical requirements, establish performance boundaries, and develop strategies for lower exposure levels. Studies to identify additional analytical techniques using equipment that is more field rugged than a GC/MS would also be beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

15 GEOTHERMAL ENERGY↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

Enhanced Geothermal Systems, EGS Collab, Sanford U↗

Simple Model Representations of Transport in a Complex Fracture and Their Effects on Long-Term Predictions

A complex fracture model for fluid flow and tracer transport was previously developed that incorporates many of the important physical effects of a realistic fracture, including advection through a heterogeneous fracture plane, partitioning of flow into multiple subfractures in the third dimension, and diffusion and sorption into fracture-filling gouge, small altered rock matrix blocks within the fracture zone, and the unaltered semi-infinite rock matrix on both sides of the fracture zone (Tsang and Doughty, 2003). It is common, however, to represent the complex fracture by much simpler models consisting of a single fracture, with a uniform or heterogeneous transmissivity distribution over its plane and bounded on both sides by a homogeneous semi-infinite matrix. Simple-model properties are often inferred from the analysis of short-term (one to a few days) site characterization (SC) tracer-test data. The question addressed in this paper is: How reliable is the temporal upscaling of these simplified models? Are they adequate are for long-term calculations that cover thousands of years? In this study, a particle-tracking approach is used to calculate tracer-test breakthrough curves (BTCs) in a complex fracture model, incorporating all the features described above, for both a short-term SC tracer test and a 10,000-year calculation. The results are considered the 'real-world'. Next, two simple fracture models, one uniform and the other heterogeneous, are introduced. Properties for these simple models are taken either from laboratory data or found by calibration to the short-term SC tracer-test BTCs obtained with the complex fracture model. Then the simple models are used to simulate tracer transport at the long-term time scale. Results show that for the short-term SC tracer test, the BTCs calculated using simple models with laboratory-measured parameters differ significantly from the BTCs obtained with the complex fracture model. By adjusting model properties, the simple models can be calibrated to reproduce the peak arrival time and height of the complex-fracture-model BTCs, but the overall match remains quite poor. Using simple models with short-term SC-calibrated parameters for long-term calculations causes order-of-magnitude errors in tracer BTCs: peak arrival time is 10-100 times too late, and peak height is 50-300 times too small. On the other hand, using simple models with laboratory-measured properties of unfractured rock samples for 10,000-year calculations results in peak arrivals and heights up to a factor of 50 too early and large, respectively. The actual magnitudes of the errors made by using the simple models depend on the parameter values assumed for the complex fracture model, but in general, simple models are not expected to provide reliable long-term predictions. The paper concludes with some suggestions on how to improve long-term prediction calculations.

54 ENVIRONMENTAL SCIENCES↗

An asixymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples

Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an axisymmetric diffusion experiment coupled with tracer profiling may be a promising approach to estimate of diffusion anisotropy of sedimentary rocks.

54 ENVIRONMENTAL SCIENCES↗

Large-Scale Transport into the Arctic: The Roles of the Midlatitude Jet and the Hadley Cell

Transport from the Northern Hemisphere (NH) midlatitudes to the Arctic plays a crucial role in determining the abundance of trace gases and aerosols that are important to Arctic climate via impacts on radiation and chemistry. Here we examine this transport using an idealized tracer with a fixed lifetime and predominantly midlatitude land-based sources in models participating in the Chemistry Climate Model Initiative (CCMI). We show that there is a 25%-45% difference in the Arctic concentrations of this tracer among the models. This spread is correlated with the spread in the location of the Pacific jet, as well as the spread in the location of the Hadley Cell (HC) edge, which varies consistently with jet latitude. Our results suggest that it is likely that the HC-related zonal-mean meridional transport rather than the jet-related eddy mixing is the major contributor to the inter-model spread in the transport of land-based tracers into the Arctic. Specifically, in models with a more northern jet, the HC generally extends further north and the tracer source region is mostly covered by surface southward flow associated with the lower branch of the HC, resulting in less efficient transport poleward to the Arctic. During boreal summer, there are poleward biases in jet location in free-running models, and these models likely underestimate the rate of transport into the Arctic. Models using specified dynamics do not have biases in the jet location, but do have biases in the surface meridional flow, which may result in differences in transport into the Arctic. In addition to the land-based tracer, the midlatitude-to-Arctic transport is further examined by another idealized tracer with zonally uniform sources. With equal sources from both land and ocean, the inter-model spread of this zonally uniform tracer is more related to variations in parameterized convection over oceans rather than variations in HC extent, particularly during boreal winter. This suggests that transport of land-based and oceanic tracers or aerosols towards the Arctic differs in pathways and therefore their corresponding inter-model variabilities result from different physical processes.

chemistry climate models↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

15 GEOTHERMAL ENERGY↗

Single–Well Injection–Drift Test to Estimate Groundwater Velocity

A simple algebraic equation is presented here to estimate the magnitude of groundwater velocity based on data from a single-well injection-drift test thereby eliminating the time-consuming and costly extraction phase. A volume of tracer-amended water was injected by forced-gradient into a single well followed by monitoring of the conservative solute tracers under natural-gradient conditions as their upgradient portions drifted back through the well. The breakthrough curve data from the single well during the drift phase was analyzed to determine the mean travel times of the tracers. The estimated mean upgradient travel distance back through the single well and the mean travel times of the tracers were used in a simple algebraic equation to estimate groundwater velocity. The groundwater velocity based on the single-well injection-drift test was estimated to be approximately 0.64 ft per day. Two transects of observation wells were used to monitor the natural-gradient tracer transport downgradient of the injection well. The one-dimensional, or dual-well, transport of the tracer from the injection well to the nearest downgradient observation well indicated that the groundwater velocity was 0.55 ft per day. The two-dimensional, or multi-well, transport of the center of mass of the tracers indicated that the groundwater velocity was 0.60 ft per day; the dual- and multi-well results were in excellent agreement with those from the single-well and validated the simple algebraic equation. In conclusion, the new single-well method presented here is relatively simple, rapid, and does not require an extraction phase.

54 ENVIRONMENTAL SCIENCES↗

Comparing facility-level methane emission rate estimates at natural gas gathering and boosting stations

Coordinated dual-tracer, aircraft-based, and direct component-level measurements were made at midstream natural gas gathering and boosting stations in the Fayetteville shale (Arkansas, USA). On-site component-level measurements were combined with engineering estimates to generate comprehensive facility-level methane emission rate estimates ('study on-site estimates (SOE)') comparable to tracer and aircraft measurements. Combustion slip (unburned fuel entrained in compressor engine exhaust), which was calculated based on 111 recent measurements of representative compressor engines, accounts for an estimated 75% of cumulative SOEs at gathering stations included in comparisons. Measured methane emissions from regenerator vents on glycol dehydrator units were substantially larger than predicted by modelling software; the contribution of dehydrator regenerator vents to the cumulative SOE would increase from 1% to 10% if based on direct measurements. Concurrent measurements at 14 normally-operating facilities show relative agreement between tracer and SOE, but indicate that tracer measurements estimate lower emissions (regression of tracer to SOE = 0.91 (95% CI = 0.83-0.99), R2 = 0.89). Tracer and SOE 95% confidence intervals overlap at 11/14 facilities. Contemporaneous measurements at six facilities suggest that aircraft measurements estimate higher emissions than SOE. Aircraft and study on-site estimate 95% confidence intervals overlap at 3/6 facilities. The average facility level emission rate (FLER) estimated by tracer measurements in this study is 17-73% higher than a prior national study by Marchese et al.

03 NATURAL GAS↗