Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Strong intracellular signal inactivation produces sharper and more robust signaling from cell membrane to nucleus

For a chemical signal to propagate across a cell, it must navigate a tortuous environment involving a variety of organelle barriers. In this work we study mathematical models for a basic chemical signal, the arrival times at the nuclear membrane of proteins that are activated at the cell membrane and diffuse throughout the cytosol. Organelle surfaces within human B cells are reconstructed from soft X-ray tomographic images, and modeled as reflecting barriers to the molecules’ diffusion. We show that signal inactivation sharpens signals, reducing variability in the arrival time at the nuclear membrane. Inactivation can also compensate for an observed slowdown in signal propagation induced by the presence of organelle barriers, leading to arrival times at the nuclear membrane that are comparable to models in which the cytosol is treated as an open, empty region. In the limit of strong signal inactivation this is achieved by filtering out molecules that traverse non-geodesic paths.

59 BASIC BIOLOGICAL SCIENCES↗

Simulation of Detecting Damage in Composite Stiffened Panel Using Lamb Waves

Lamb wave damage detection in a composite stiffened panel is simulated by performing explicit transient dynamic finite element analyses and using signal imaging techniques. This virtual test process does not need to use real structures, actuators/sensors, or laboratory equipment. Quasi-isotropic laminates are used for the stiffened panels. Two types of damage are studied. One type is a damage in the skin bay and the other type is a debond between the stiffener flange and the skin. Innovative approaches for identifying the damage location and imaging the damage were developed. The damage location is identified by finding the intersection of the damage locus and the path of the time reversal wave packet re-emitted from the sensor nodes. The damage locus is a circle that envelops the potential damage locations. Its center is at the actuator location and its radius is computed by multiplying the group velocity by the time of flight to damage. To create a damage image for estimating the size of damage, a group of nodes in the neighborhood of the damage location is identified for applying an image condition. The image condition, computed at a finite element node, is the zero-lag cross-correlation (ZLCC) of the time-reversed incident wave signal and the time reversal wave signal from the sensor nodes. This damage imaging process is computationally efficient since only the ZLCC values of a small amount of nodes in the neighborhood of the identified damage location are computed instead of those of the full model.

Wang, John T.↗

Denoising Seismic Waveforms Using a Wavelet-Transform-Based Machine-Learning Method

Seismic waveform data recorded at stations can be thought of as a superposition of the signal from a source of interest and noise from other sources. Frequency‐based filtering methods for waveform denoising do not result in desired outcomes when the targeted signal and noise occupy similar frequency bands. Recently, denoising techniques based on deep‐learning convolutional neural networks (CNNs), in which a recorded waveform is decomposed into signal and noise components, have led to improved results. These CNN methods, which use short‐time Fourier transform representations of the time series, provide signal and noise masks for the input waveform. These masks are used to create denoised signal and designaled noise waveforms, respectively. However, advancements in the field of image denoising have shown the benefits of incorporating discrete wavelet transforms (DWTs) into CNN architectures to create multilevel wavelet CNN (MWCNN) models. The MWCNN model preserves the details of the input due to the good time–frequency localization of the DWT. In this report we use a data set of over 382,000 constructed seismograms recorded by the University of Utah Seismograph Stations network to compare the performance of CNN and MWCNN‐based denoising models. Evaluation of both models on constructed test data shows that the MWCNN model outperforms the CNN model in the ability to recover the ground‐truth signal component in terms of both waveform similarity and preservation of amplitude information. Model evaluation of real‐world data shows that both the CNN and MWCNN models outperform standard band‐pass filtering (BPF; average improvement in signal‐to‐noise ratio of 9.6 and 19.7 dB, respectively, with respect to BPF). Evaluation of continuous data suggests the MWCNN denoiser can improve both signal detection capabilities and phase arrival time estimates.

58 GEOSCIENCES↗

Effectiveness of an Expert System for Astronaut Assistance on a Sleep Experiment

Principal Investigator-in-a-Box ([PI]) is an expert system designed to train and assist astronauts with the performance of an experiment outside their field of expertise, particularly when contact with the Principal Investigators on the ground is limited or impossible. In the current case, [PI] was designed to assist with the calibration and troubleshooting procedures of the Neurolab Sleep and Respiration Experiment during the pre-sleep period of no ground contact. It displays physiological signals in real time during the pre-sleep instrumentation period, and alerts the astronauts when a poor signal quality is detected. Results of the first study indicated a beneficial effect of [PI] and training in reducing anomaly detection time and the number of undetected anomalies. For the in-flight performance, excluding the saturated signals, the expert system had an 84.2% detection accuracy, and the questionnaires filled out by the astronauts showed positive crew reactions to the expert system.

Heher, Dennis↗

Optimal Traffic Signal Control Using Priority Metric Based on Real-Time Measured Traffic Information

Optimizing traffic control systems at traffic intersections can reduce network-wide fuel consumption as well as improve traffic flow. While traffic signals have conventionally been controlled based on predetermined schedules, various adaptive control systems have been developed recently using advanced sensors such as cameras, radars, and LiDARs. By utilizing rich traffic information enabled by the advanced sensors, more efficient or optimal traffic signal control is possible in response to varying traffic conditions. This paper proposes an optimal traffic signal control method to minimize network-wide fuel consumption utilizing real-time traffic information provided by advanced sensors. This new method employs a priority metric calculated by a weighted sum of various factors, including the total number of vehicles, total vehicle speed, vehicle waiting time, and road preference. Genetic Algorithm (GA) is used as a global optimization method to determine the optimal weights in the priority metric. In order to evaluate the effectiveness of the proposed method, a traffic simulation model is developed in a high-fidelity traffic simulation environment called SUMO, based on a real-world traffic network. The traffic flow within this model is simulated using actual measured traffic data from the traffic network, enabling a comprehensive assessment of the novel optimal traffic signal control method in realistic conditions. The simulation results show that the proposed priority metric-based real-time traffic signal control algorithm can significantly reduce network-wide fuel consumption compared to the conventional fixed-time control and coordinated actuated control methods that are currently used in the modeled network. Additionally, incorporating truck priority in the priority metric leads to further improvements in fuel consumption reduction.

47 OTHER INSTRUMENTATION↗

Time-Gated Raman Spectroscopy (Intern Final Report)

Time-gated Raman spectroscopy is a powerful tool for rapid non-destructive analysis of chemical compounds, particularly when combined with other investigative methods. Time-gating the signal obtained from a sample during Raman spectroscopy allows for the removal of background emission and black body radiation, improving clarity and accuracy of scans. The main objectives of this project were to prove the lab’s time-gated Raman spectroscopy system works as proof of concept and to make select improvements to the in-house LabVIEW software used to run the time-gated system. This time-gated system will be added to the CTK’s TAP reactors in the future, but this is out of the scope of this internship project. This research is important, as understanding the mechanisms behind catalysts leads to designing better systems/materials and the perfection of catalysts, and energy-efficient chemical manufacturing is key when designing a greener future. The research for this project was done with samples at both ambient conditions in sample holders and at operando conditions (i.e., high temperature, unsteady-state) inside a small-volume chemical reactor. Numerous spectro-kinetic scans of the catalysts were obtained, but the advanced dynamics of these systems are still being interpreted. There is data that demonstrates that the time-gated system is correctly rejecting emission from samples, and one can observe real-time changes in the signal from the sample, due to coking or changes induced by redox chemistry. Chemical manufacturers and the planet are the main beneficiaries of catalysis research, as better catalysts will reduce carbon emissions.

36 MATERIALS SCIENCE↗

Real-Time, High-Frequency QRS Electrocardiograph

An electronic system that performs real-time analysis of the low-amplitude, high-frequency, ordinarily invisible components of the QRS portion of an electrocardiographic signal in real time has been developed. Whereas the signals readily visible on a conventional electrocardiogram (ECG) have amplitudes of the order of a millivolt and are characterized by frequencies <100 Hz, the ordinarily invisible components have amplitudes in the microvolt range and are characterized by frequencies from about 150 to about 250 Hz. Deviations of these high-frequency components from a normal pattern can be indicative of myocardial ischemia or myocardial infarction

Schlegel, Todd T.↗

Determining Orientations of Optical Transition Dipole Moments Using Ultrafast X-ray Scattering

Here, identification of the initially prepared, optically active state remains a challenging problem in many studies of ultrafast photoinduced processes. We show that the initially excited electronic state can be determined using the anisotropic component of ultrafast time-resolved X-ray scattering signals. The concept is demonstrated using the time-dependent X-ray scattering of N -methyl morpholine in the gas phase upon excitation by a 200 nm linearly polarized optical pulse. Analysis of the angular dependence of the scattering signal near time zero renders the orientation of the transition dipole moment in the molecular frame and identifies the initially excited state as the 3pz Rydberg state, thus bypassing the need for further experimental studies to determine the starting point of the photoinduced dynamics and clarifying inconsistent computational results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical simulation of a signal for a scheme of an atomic spin gyroscope with optical detection

An operation scheme of an atomic spin gyroscope with optical detection is described, in which two noble gas isotopes, {sup 129} Xe and {sup 131} Xe, are used as carriers of the spin of an atomic nucleus. Based on this scheme, we construct a theoretical model of the dynamics of the spin polarisation of an alkali metal and the magnetisation of a noble gas under conditions of spin-exchange interaction and optical pumping. This model allows one to simulate the pumping and signal readout in the gyroscope scheme. The time dependences of this signal are plotted, the analysis of which shows that the signal has a sophisticated complex structure. Thus, the problem arises of demodulating this signal based on the improvement of demodulation methods and algorithms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of the Crab Pulsar above 25 GeV with the MAGIC Telescope

The 17 m diameter Cherenkov telescope MAGIC, located on the Canary Island of La Palma, has the lowest trigger threshold among operating Cherenkov telescopes; this makes it a very promising tool for the detection of the pulsed gamma-ray ({gamma}-ray) emission from ground. Recently, a new analog summation trigger concept, which allows reducing the threshold even further, has been designed and implemented. The analog signals of patches in the camera, comprising 18 pixels each, are summed up in the analog mode. In order to prevent triggers from photomultiplier (PMT) afterpulses, the individual pixel signals are clipped at a preset amplitude level and then added up. The average FWHM of the time duration of signals induced by cosmic rays is 2.6 ns. This allows one to keep the coincidence time window very small and thus to strongly suppress accidental triggers. In the usual digital trigger designs, the signal should be above a certain threshold from each individual pixel to contribute to the trigger. In the summation trigger all low amplitude signals in a given patch in the camera are summed up and fully contribute to the trigger.The new trigger concept provides a low cost trigger for Cherenkov telescopes and it is very effective and stable. This trigger system for the MAGIC telescope was installed in October 2007 and was successfully used in the detection of the Crab Pulsar above 25 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-frequency analysis of non-stationary fusion plasma signals using an improved Hilbert-Huang transform

An improved Hilbert-Huang transform method is developed to the time-frequency analysis of non-stationary signals in tokamak plasmas. Maximal overlap discrete wavelet packet transform rather than wavelet packet transform is proposed as a preprocessor to decompose a signal into various narrow-band components. Then, a correlation coefficient based selection method is utilized to eliminate the irrelevant intrinsic mode functions obtained from empirical mode decomposition of those narrow-band components. Subsequently, a time varying vector autoregressive moving average model instead of Hilbert spectral analysis is performed to compute the Hilbert spectrum, i.e., a three-dimensional time-frequency distribution of the signal. The feasibility and effectiveness of the improved Hilbert-Huang transform method is demonstrated by analyzing a non-stationary simulated signal and actual experimental signals in fusion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separating Cloud and Drizzle Signals in Radar Doppler Spectra Using a Parametric Time Domain Method

The ability to separate cloud and drizzle returns in active remote sensing observations is important for understanding the microphysics of clouds and precipitation. Yet, robust separations remain challenging in radar remote sensing. Prior methods for cloud and drizzle separation for radar observations use the properties of the Doppler spectra such as skewness. However, these methods have challenges when the drizzle becomes dominant in the observation volume. This paper presents a parametric time domain method (PTDM) that separates cloud and drizzle using the Doppler spectra measurements without assuming any prior properties of cloud and drizzle. The advantage of PTDM is that it can estimate the signal properties in the time domain and can obtain the cloud and drizzle estimates simultaneously. Based on our radar signal simulations, the uncertainty in estimated power and velocity from PTDM are within 2 dB and 0.02 m s -1 , respectively. We have also evaluated the PTDM algorithm using observations from the Atmospheric Radiation Measurement (ARM) Program W-band cloud radar in the Clouds, Aerosols, and Precipitation in the Marine Boundary Layer (CAP-MBL) campaign at the Azores in 2009–10. Two cases corresponding to light and moderate drizzling conditions are considered for the study. The statistics of the estimates obtained show that the PTDM method performs well in separating the cloud and drizzle returns. Finally, the estimated cloud and drizzle reflectivity from PTDM were used to retrieve their corresponding microphysical properties, showing that the retrieved liquid water path agrees to 25 g m -2 with the benchmark microwave method.

Engineering↗

Search for a 2-quasiparticle high-K isomer in {sup 256}Rf

The energies of 2-quasiparticle (2-qp) states in heavy shell-stabilized nuclei provide information on the single-particle states that are responsible for the stability of superheavy nuclei. We have calculated the energies of 2-qp states in {sup 256}Rf, which suggest that a long-lived, low-energy 8{sup -} isomer should exist. A search was conducted for this isomer through a calorimetric conversion electron signal, sandwiched in time between implantation of a {sup 256}Rf nucleus and its fission decay, all within the same pixel of a double-sided Si strip detector. A 17(5)-{mu}s isomer was identified. However, its low population, {approx}5(2)% that of the ground state instead of the expected {approx}30%, suggests that it is more likely a 4-qp isomer. Possible reasons for the absence of an electromagnetic signature of a 2-qp isomer decay are discussed. These include the favored possibility that the isomer decays by fission, with a half-life indistinguishably close to that of the ground state. Another possibility, that there is no 2-qp isomer at all, would imply an abrupt termination of axially symmetric deformed shapes at Z=104, which describes nuclei with Z=92-103 very well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

All optical sampling by slanted light interrogation for cross-correlated encoded recording (slicer)

Single-shot transient optical signals are recorded in a time regime of picoseconds to nanosecond. An auxiliary pump beam is crossed through the signal to sample a diagonal ‘slice’ of space-time, analogous to a rolling shutter. The slice is then imaged onto an ordinary camera, where the recorded spatial trace is a direct representation of the time content of the signal. The pump samples the signal by optically exciting carriers that modify the refractive index in a conventional semiconductor wafer. Through use of birefringent retarders surrounding the wafer, the integrating response of the rapidly excited but persistent carriers is differentiated by probing with two polarization-encoded time-staggered signal replicas that are recombined to interfere destructively.

42 ENGINEERING↗

Time reversal of continuous-wave, monochromatic signals in elastic media

Experimental observations of spatial focusing of continuous-wave, steady-state elastic waves in a reverberant elastic cavity using time reversal are reported here. Spatially localized focusing is achieved when multiple channels are employed, while a single channel does not yield such focusing. The amplitude of the energy at the focal location increases as the square of the number of channels used, while the amplitude elsewhere in the medium increases proportionally with the number of channels used. The observation is important in the context of imaging in solid laboratory samples as well as problems involving continuous-wave signals in Earth.

58 GEOSCIENCES↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Heterodyne Interferometer with a Phase Modulated Source

The present invention relates to a heterodyne interferometer system with a pre-processing of the target signal to isolate and remove self-interference signals using a known phase modulation of the carrier signal's frequency. Where self- interference signals do not include a time delay inherent in the target signal that travels to the target reflector, by selecting a modulation frequency tuned to the time delay and then filtering the resultant signal the target beam can be isolated and the self-interference signal can be effectively removed The system includes a modulation unit to apply a phase modulation to the carrier signal, and a mixing unit that demodulates the target signal at the modulation frequency to isolate the target beam.

Serge Dubovitsky↗