Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Controlling T c of Iridium films using interfacial proximity effects

High precision calorimetry using superconducting transition edge sensors requires the use of superconducting films with a suitable T c , depending on the application. To advance high-precision macrocalorimetry, we require low-T c films that are easy to fabricate. A simple and effective way to suppress T c of superconducting Iridium through the proximity effect is demonstrated by using Ir/Pt bilayers as well as Au/Ir/Au trilayers. While Ir/Au films fabricated by applying heat to the substrate during Ir deposition have been used in the past for superconducting sensors, we present results of T c suppression on Iridium by deposition at room temperature in Au/Ir/Au trilayers and Ir/Pt bilayers in the range of $\sim$20-100~mK. Measurements of the relative impedance between the Ir/Pt bilayers and Au/Ir/Au trilayers fabricated show factor of $\sim$10 higher values in the Ir/Pt case. These new films could play a key role in the development of scalable superconducting transition edge sensors that require low-T c films to minimize heat capacity and maximize energy resolution, while keeping high-yield fabrication methods.

Hennings-Yeomans, R↗

Printed Flexible Sensors for NASA Applications

As human spaceflight pushes beyond Low Earth Orbit (LEO), resupply of consumables becomes a significant challenge. One solution to this problem is In-Space Manufacturing (ISM), the capability to perform on-demand manufacturing and repair of consumables in an in-space environment. ISM offers significant flexibility to missions as it allows for a high degree of tailorability and reduction in launch mass. Leveraging advancements in fabrication, repair and recycling, ISM provides a highly sustainable and affordable solution to Exploration mission operations and logistics. In this talk, advances in printed electronics and sensors, ranging from nanomaterial ink development and hands-free fabrication methodologies to devices will be presented. Applications presented will include sensors for crew health monitoring, structural health monitoring and power generation.

sensors↗

Apparatus analysis and preliminary design of low gravity porous solids experiment for STS Orbiter mid-deck

The apparatus analysis laboratory equipment design and fabrication and the preliminary design of the Combustion of Porous Solids Experiment for operation in the mid-deck area of the Shuttle are described. The apparatus analysis indicated that the mid-deck region of the STS was a feasible region of the Shuttle for operation. A sixteen tube concept was developed with tubes of 75 cm length and up to 5.6 cm accommodated. The experiment is viewed by IR sensors and a 16 mm camera. Laboratory equipment was designed and fabricated to test the parible injection, mixing and venting concepts. This equipment was delivered to NASA/LeRC. A preliminary design was made for the experiment based upon the apparatus analysis. The design incorporated results from the Phase ""O'' Safety Review. This design utilizes a closed tube concept in which the particles are stored, injected and burned with no coupling to the Shuttle environment. Drawings of the major components and an assembly are given. The electronics are described for the experiment. An equipment list is presented and an experiment weight estimate is determined. The mission operation requirements are outlined.

Fleeter, R. D.↗

Variable Sampling Mapping

The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.

Smith, Jeffrey, S.↗

Radiation hardness of three-dimensional polycrystalline diamond detectors

The three-dimensional concept in particle detection is based on the fabrication of columnar electrodes perpendicular to the surface of a solid state radiation sensor. It permits to improve the radiation resistance characteristics of a material by lowering the necessary bias voltage and shortening the charge carrier path inside the material. If applied to a long-recognized exceptionally radiation-hard material like diamond, this concept promises to pave the way to the realization of detectors of unprecedented performances. We fabricated conventional and three-dimensional polycrystalline diamond detectors, and tested them before and after neutron damage up to 1.2 ×10{sup 16 }cm{sup −2}, 1 MeV-equivalent neutron fluence. We found that the signal collected by the three-dimensional detectors is up to three times higher than that of the conventional planar ones, at the highest neutron damage ever experimented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indium phosphide-based monolithically integrated PIN waveguide photodiode readout for resonant cantilever sensors

An integrated photodiode displacement readout scheme for a microelectromechanical cantilever waveguide resonator sensing platform is presented. III-V semiconductors are used to enable the monolithic integration of passive waveguides with active optical components. This work builds upon previously demonstrated results by measuring the displacement of cantilever waveguide resonators with on-chip waveguide PIN photodiodes. The on-chip integration of the readout provides an additional 70% improvement in mass sensitivity compared to off-chip photodetector designs due to measurement stability and minimized coupling loss. In addition to increased measurement stability, reduced packaging complexity is achieved due to the simplicity of the readout design. We have fabricated cantilever waveguides with integrated photodetectors and experimentally characterized these cantilever sensors with monolithically integrated PIN photodiodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-Sensing, Stretchable, Active Circuit Arrays: Liquid Metal Paste as a Combination Interconnect and Strain Sensor

Stretchable electrical interconnects and substrate materials are increasingly used to create flexible and con-formable electronic systems for soft robotics, smart textiles, and wearable devices. Wires fabricated using composite or liquid conductive inks encapsulated in silicone enable high strain and are mechanically robust. The resistance of these inter-connects increases with strain, which can present challenges for power delivery and signaling among electronic components. However, this effect can be used directly to estimate strain within a stretchable circuit without the need for additional sensor components. In this work, we present an approach for fabricating fully-stretchable, multi-layer active circuit arrays in silicone using liquid metal paste interconnects, in which power and data wires are re-purposed as strain sensors to estimate substrate deformation. As a proof-of-principle, we demonstrate a 3×3 active circuit array that self-senses relative voltage supply at each node to estimate deformation and consumes less than 10 mA per node. Each node is digitally addressable and performs both analog measurement and digital conversion. All interconnects are fabricated using liquid metal paste, and power, data, and sensing are performed over a shared, four-wire interface in this multi-layer stretchable printed circuit board.

99 GENERAL AND MISCELLANEOUS↗

Slow-Light Mid-IR Silicon Photonic Chips for NO 2 and CH 4 Gas Detection

A compact, chip-scale mid-infrared gas sensor is demonstrated, leveraging a two-dimensional photonic crystal waveguide (PCW) fabricated on a silicon-on-insulator (SOI) platform. The PCW comprises a hexagonal lattice with lattice constant a = 860 nm and hole radius r = 0.22a, incorporating a central line defect of reduced-radius holes (r s = 0.7r) to induce slow-light propagation near the photonic band edge with a group index of approximately 73, thereby enhancing light-matter interaction. The sensor operates at fundamental absorption wavelengths of 3.42 μm for nitrogen dioxide (NO 2 ) and 3.40 μm for methane (CH 4 ), utilizing the strongest molecular vibrational transitions for maximum sensitivity. Experimental validation was conducted using dynamically diluted gas mixtures generated by mass flow controllers, with signal acquisition performed by a liquid nitrogen-cooled InSb detector. For NO 2 , the sensor exhibited excellent linear response over 5–25 ppm (part per million) with coefficient of determination R 2 = 0.9934, achieving a detection limit of 210 ppb (part per billion)─representing the first reported silicon photonic-based NO 2 detection. For CH 4 , exposure to 25 ppm resulted in a 6.4% decrease in transmitted intensity, demonstrating multigas sensing capability. The CMOS-compatible fabrication process and compact 3 mm device footprint establish this SOI-PCW platform as a scalable, low-power solution for integrated mid-infrared gas sensing, with significant potential for environmental monitoring and industrial safety applications.

Crystals↗

Development of Field-Controlled Smart Optic Materials (ScN, AlN) with Rare Earth Dopants

The purpose of this investigation is to develop the fundamental materials and fabrication technology for field-controlled spectrally active optics that are essential for industry, NASA, and DOD applications such as: membrane optics, filters for LIDARs, windows for sensors, telescopes, spectroscopes, cameras, flat-panel displays, etc. ScN and AlN thin films were fabricated on c-axis Sapphire (0001) or quartz substrate with the RF and DC magnetron sputtering. The crystal structure of AlN in fcc (rocksalt) and hcp (wurtzite) were controlled. Advanced electrical characterizations were performed, including I-V and Hall Effect Measurement. ScN film has a free carrier density of 5.8 x 10(exp 20)/per cubic centimeter and a conductivity of 1.1 x 10(exp 3) per centimeter. The background ntype conductivity of as-grown ScN has enough free electrons that can readily interact with the photons. The high density of free electrons and relatively low mobility indicate that these films contain a high level of shallow donors as well as deep levels. Also, the UV-Vis spectrum of ScN and AlN thin films with rare earth elements (Er or Ho) were measured at room temperature. Their optical band gaps were estimated to be about 2.33eV and 2.24eV, respectively, which are obviously smaller than that of undoped thin film ScN (2.4eV). The red-shifted absorption onset gives direct evidence for the decrease of band gap (Eg) and the energy broadening of valence band states are attributable to the doping. As the doped elements enter the ScN crystal lattices, the localized band edge states form at the doped sites with a reduction of Eg. Using a variable angle spectroscopic ellipsometer, the decrease in refractive index with applied field is observed with a smaller shift in absorption coefficient.

Kim, Hyun-Jung↗

Combustion synthesis of LaFeO{sub 3} sensing nanomaterial

Since industrial revolution, human activities drive towards unsustainable global economy due to the overexploitation of natural resources and the unacceptable emissions of pollution and greenhouse gases. In order to address that issue, engineering research has been focusing on gas sensors development for monitoring gas emissions and controlling the combustion process sustainability. Semiconductors metal oxides sensors are attractive technology because they require simple design and fabrication, involving high accessibility, small size and low cost. Perovskite oxides are the most promising sensing materials because sensitivity, selectivity, stability and speed-response can be modulated and optimized by changing the chemical composition. One of the most convenient synthesis process of perovskite is the citrate-nitrate auto-combustion method, in which nitrate is the oxidizing agent and citrate is the fuel and the chelating argent in the same time. Since the sensibility of perovskite oxides depends on the defective crystallographic structure and the nanomorphology, the experimental was designed in order to study the dependence of powder properties on the synthesis conditions, such as the solution acidity and the relative amount of metals, nitrates and citric acid. Crystalline structure was studied in depth for defining the effects of synthesis conditions on size, morphology and crystallographic structure of nanopowders of LaFeO{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Fabrication and characterization of pristine and annealed Ga doped ZnO thin films using sputtering

ZnO is a wide-band gap, transparent, polar semiconductor with unparalleled optoelectronic, piezoelectric, thermal and transport properties, which make it the material of choice for a wide range of applications such as blue/UV optoelectronics, energy conversion, transparent electronics, spintronic, plasmonic and sensor devices. We report, three sets of Ga doped Zinc Oxide (GZO) were fabricated in different sputtering power (100 watt, 200 watt and 300 watt). Thereafter films were annealed in nitrogen ambient for 30 minutes at 400° C. From the optical absorption spectroscopy it was found that pristine films are showing a 75% transmittance in the visible region of light and it increases after the annealing. However, for 300 W grown sample opposite trend has been achieved for the post annealed sample. X-ray diffraction pattern of all the pristine and annealed films showed a preferable growth orientation at (002) phase. Some other weak peaks were also appeared in different angle which indicates that films are polycrystalline in nature. XRD data also reveals that crystallite size increases with sputtering power up to 200 W and thereafter it decreases with the deposition power. It also noted that the crystallite size of the annealed film increases with compare to the non annealed films. At room temperature an enhancement in electrical properties of Ga doped ZnO thin films was noted for the annealed ZnO films except for the film deposited at 300 watt. More significantly, it was found that annealed thin films showed the resistivity in the range of 10{sup −3} ∼ 10{sup −4} ohm-cm. Such a high optical transmittance and conducting zinc-oxide thin film can be used as a window layer in solar cell.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced electronic sensors

A micro-structured device that can improve sensitivity and signal-to-noise for electronic sensor materials is embedded in electrically resistive materials. The technology includes a three-dimensional embedded electrode structure and fabrication methods for making the device for electronic sensing in bulk resistive materials. Embedded electrode structures address issues in conventional sensors by allowing independent control of sensitive material thickness, area, electric field intensity, and field direction.

Doty, Fred Patrick↗

Hybrid Piezoelectric/Fiber-Optic Sensor Sheets

Hybrid piezoelectric/fiber-optic (HyPFO) sensor sheets are undergoing development. They are intended for use in nondestructive evaluation and long-term monitoring of the integrity of diverse structures, including aerospace, aeronautical, automotive, and large stationary ones. It is anticipated that the further development and subsequent commercialization of the HyPFO sensor systems will lead to economic benefits in the form of increased safety, reduction of life-cycle costs through real-time structural monitoring, increased structural reliability, reduction of maintenance costs, and increased readiness for service. The concept of a HyPFO sensor sheet is a generalization of the concept of a SMART Layer(TradeMark), which is a patented device that comprises a thin dielectric film containing an embedded network of distributed piezoelectric actuator/sensors. Such a device can be mounted on the surface of a metallic structure or embedded inside a composite-material structure during fabrication of the structure. There is has been substantial interest in incorporating sensors other than piezoelectric ones into SMART Layer(TradeMark) networks: in particular, because of the popularity of the use of fiber-optic sensors for monitoring the "health" of structures in recent years, it was decided to incorporate fiber-optic sensors, giving rise to the concept of HyPFO devices.

Lin, Mark↗

Progress towards developing neutron tolerant magnetostrictive and piezoelectric transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗