Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

01 COAL, LIGNITE, AND PEAT↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗

Geomechanical modeling of distributed fiber-optic sensor measurements

Fiber-optic-based distributed acoustic sensors (DAS) are a new technology that can be deployed in a well and are continuously interrogated during operations. These sensors calculate the strain (or strain rate) at all points along the fiber and have been used extensively to monitor hydraulic stimulations. The data from these sensors indicate that they are sensitive to high-frequency signals associated with microseismicity and low-frequency signals associated with fracture growth. We have developed a set of idealized models to simulate these signals and to identify interpretation methods that may be used to estimate fracture location, geometry, and extent. We use a multiphysics code that includes rock physics, fluid flow, and elastic-wave propagation to generate synthetic DAS measurements from a set of simple models that mimic hydraulic fracturing. We then relate the signals observed in the synthetic DAS to specific features in the model such as fracture height, width, and aperture. Our results demonstrate that the synthetic DAS measurements may be used to determine field DAS measurements and to optimize the design of future sensor deployments for sensitivity to fracture attributes.

03 NATURAL GAS↗

Optical stress sensor based on electro-optic compensation for photoelastic birefringence in a single crystal

An optical stress sensor is proposed by using a single crystal with both electro-optic and photoelastic effects. Different from previous crystal-based stress sensors, the proposed sensor is based on electro-optic compensation for stress-induced birefringence and does not need an additional quarter-wave plate or modulator, because the stress-sensing element is simultaneously used as an electro-optic compensator. Candidate sensing materials include electro-optic crystals of the 3 m symmetry group and all glass with large Kerr coefficients. A primary experiment has demonstrated that the stress-induced birefringence in lithium niobate crystal can be compensated by its electro-optic birefringence. The proposed stress sensor is compact and low cost, and it is possible to achieve closed-loop stress measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor Fish Characterization of Fish Passage Conditions through John Day Dam Spillbay 20 with a Modified Flow Deflector

Fish passage conditions over a modified deflector in Spillbay 20 at John Day Dam were evaluated by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers (USACE), Portland District, using Sensor Fish devices. The objectives of the study were to describe and compare passage exposure conditions at two spill discharges, 2.4 and 4.0 thousand cubic feet per second (kcfs), identifying potential fish injury regions within the routes, and to evaluate a low-tailwater condition at the 2.4-kcfs discharge. The study was performed in April 2010 concurrent with HI-Z balloon-tag studies by Normandeau Associates, Inc. Sensor Fish data were analyzed to estimate 1) exposure conditions, particularly exposure to severe collision and shear events; 2) differences in passage conditions between treatments; and 3) relationships to live-fish injury and mortality data estimates. Nearly all Sensor Fish significant events were classified as collisions; the most severe occurred at the gate, on the spillbay chute, or at the deflector transition. Collisions in the gate region were observed only during the 2.4-kcfs discharge, when the tainter gate was open 1.2 ft. One shear event was observed during the evaluation, occurring at the deflector transition during passage at the 2.4-kcfs discharge at low tailwater. Flow quality, computed using the Sensor Fish turbulence index, was best for passage at the low-flow low-tailwater condition as well. The worst flow quality was observed for the 4.0-kcfs test condition. Contrasting the passage exposure conditions, the 2.4-kcfs low-tailwater treatment would be most deleterious to fish survival and well-being.

54 ENVIRONMENTAL SCIENCES↗

PVT-NG Sensor Final Report

This document is a final report for the polyvinyl toluene (PVT) neutron-gamma (PVT-NG) project, which was sponsored by the Domestic Nuclear Detection Office (DNDO). The PVT-NG sensor uses PVT detectors for both gamma and neutron detection. The sensor exhibits excellent spectral resolution and gain stabilization, which are features that are beneficial for detection of both gamma-ray and neutron sources. In fact, the ability to perform isotope identification based on spectra that were measured by the PVT-NG sensor was demonstrated. As described in a previous report, the neutron sensitivity of the first version of the prototype was about 25% less than the DNDO requirement of 2.5 cps/ng for bare 252 Cf. This document describes design modifications that were expected to improve the neutron sensitivity by about 50% relative to the PVT-NG prototype. However, the project was terminated before execution of the design modifications after portal vendors demonstrated other technologies that enable neutron detection without the use of 3 He. Nevertheless, the PVT-NG sensor development demonstrated several performance goals that may be useful in future portal designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multipurpose Acoustic Sensor for Downhole Fluid Monitoring

The projects objectives and purpose are to: (1) development a multipurpose acoustic sensor for downhole fluid monitoring in Enhanced Geothermal Systems (EGS) reservoirs over typical ranges of pressures and temperatures and demonstrate its capabilities and performance for different EGS systems; (2) determine in real-time and in a single sensor package several parameters - temperature, pressure, fluid flow and fluid properties; (3) needed in nearly every phase of an EGS project, including Testing of Injection and Production Wells, Reservoir Validation, Inter-well Connectivity, Reservoir Scale Up and Reservoir Sustainability. (4) Current sensors are limited to operating at lower temperatures, but the need is for logging at high temperatures. The present project deals with the development of a novel acoustic-based sensor that can work at temperatures up to 374 °C, in inhospitable environments.

15 GEOTHERMAL ENERGY↗

Use of Occupancy Sensors in LED Parking Lot and Garage Applications: Early Experiences

Occupancy sensor systems are gaining traction as an effective technological approach to reducing energy use in exterior commercial lighting applications. Done correctly, occupancy sensors can substantially enhance the savings from an already efficient lighting system. However, this technology is confronted by several potential challenges and pitfalls that can leave a significant amount of the prospective savings on the table. This report describes anecdotal experiences from field installations of occupancy sensor controlled light-emitting diode (LED) lighting at two parking structures and two parking lots. The relative levels of success at these installations reflect a marked range of potential outcomes: from an additional 76% in energy savings to virtually no additional savings. Several issues that influenced savings were encountered in these early stage installations and are detailed in the report. Ultimately, care must be taken in the design, selection, and commissioning of a sensor-controlled lighting installation, else the only guaranteed result may be its cost.

LED lighting↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian Optimal Sensor Augmentation Via Estimated Mutual Information

We consider the problem of designing a sensor network to most efficiently locate the source of a seismic event. The left panel of Figure 1 shows 982 possible sensor locations in a region of interest. The objective is to infer the unknown location of an earthquake, indicated by the gold dot for illustration purposes. Assume that three sensors have already been placed for data collection. Travel times of the P-wave from the source to the three sensors are observed and used to infer the unknown source location via a Bayesian statistical model described subsequently. The right panel of Figure 1 shows samples from the resulting posterior distribution for source location along with a posterior estimate of this location.

47 OTHER INSTRUMENTATION↗

Doped Lanthanum Chromite-refractory Based Composites Sensors for High Temperature Monitoring in Harsh Environments Systems

In order to test and monitor the operational stability and conditions of various energy, and manufacturing systems and their components, development of accurate sensors capable of operating at temperatures in excess of 1000 °C in various environments for long durations is required. In addition, many of these harsh-environment systems do not permit sensors to be directly inserted, so these sensors need to be embedded into thermal protective materials. In this work were developed high-temperature embedded thermocouples composed of various doped lanthanum chromites-refractory based composites synthesized by a mixed-oxide route and directly embedded into a Al2O3 based refractory. The electrical properties were specifically manipulated by altering the level of percolation of the conductive phase within the refractory constituent. Chemical stability of sensors was determined by phase development analysis by X-ray diffraction and X-ray photoelectron spectroscopy; Seebeck coefficients were determined by thermoelectric voltages measurements at temperature up to 1400 oC.

Perovskite LaCrO3, High-temperature conductivity, ↗

Embedded High-Temperature Sensors: Enhancing Thermoelectrical Performance with Refractory Composites Gradient Layers

To monitor the stability of various energy and manufacturing systems, sensors capable of operating at temperatures exceeding 1000 °C in diverse environments for extended durations are essential. However, under harsh conditions, degradation of sensing materials is a concern that can be controlled by embedding the sensors into refractory oxides. Doped-LaCrO3 based composites are excellent candidates for high-temperature sensing applications due to their good thermoelectrical properties. However, chemical reactivity between the conductive phase and the refractory oxides can decrease the performance of the sensors. In this work, it was devised gradient-type protective layers safeguarding conductive phases within embedded thermocouples, which were fabricated and characterized by X-Ray Diffraction for phase development analysis, Scanning Electron Microscopy and Energy-dispersive X-ray spectroscopy for microstructure and cationic interdiffusion kinetics, long-term thermoelectric testing was completed up to 1400 °C. The enhanced performance of these novel sensors addresses a critical limitation, rendering them viable for long-term high-temperature applications.

20 FOSSIL-FUELED POWER PLANTS↗

Integration of sensors through additive manufacturing leading to increased efficiencies of gas turbines for power generation and propulsion

To realize the full capability of additively manufactured components in complex energy systems, it is imperative to minimize early component failures during development phases and during operation. Traditional field feedback timelines and offline inspection protocols significantly reduce the design-manufacturing iteration times. To address this specific question, the project developed and demonstrated a method for the integration of sensors into complex components through additive manufacturing. The team used gas turbine engines as a platform, which meets the need of both power generation and propulsion and offer opportunities for cost reductions and efficiency increases. The innovation of this intelligent integration of sensors into complex components uniquely customized to address questions of integrity and durability for additively manufactured components. With real-time sensing data from additively manufactured components, turbine manufacturers will realize higher efficiencies, reduced component failures, and a 30-50% acceleration in product deployment of high efficiency gas turbine components due to a faster reduction in component risk assessment under actual operating conditions. This is a transformative shift towards a data-driven design and qualification of additively manufactured gas turbine components. To directly integrate sensors into additively manufactured components with all the complexities of actual hardware, powder bed fusion (direct metal laser sintering) and laser metal deposition technologies was developed. Validation took take place in two university laboratories both of which contain actual engine hardware and closely simulate a gas turbine prior to demonstrating the technology in a turbine development test. Indeed, two major technologies from this research cold impact turbine systems in the near future: (1) higher efficiency materials and designs enabled by additive manufacturing with 50% faster design to manufacturing cycle time, to enable faster time-to-market targets; and (2) integration of sensors into additively manufactured components enabling broad health and condition based prognostics for faster component and engine risk reduction.

33 ADVANCED PROPULSION SYSTEMS↗

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

An Overview of Emerging Nuclear Sensor Technologies: Challenges, Advancements and Applications

Nuclear sensors are essential for detecting and measuring nuclear radiation in various applications, including nuclear power plants, medical imaging, and environmental monitoring. Traditional nuclear sensors have served these fields for decades, but recent advancements in emerging sensor technologies offer novel improvements in accuracy, sensitivity, and reliability. This review presents an up-to-date overview of recent progress in the advancements of nuclear sensor technologies, their diverse applications, challenges in implementation, and opportunities for future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗