Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Selection optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Global interrupt and barrier networks

A system and method for generating global asynchronous signals in a computing structure. Particularly, a global interrupt and barrier network is implemented that implements logic for generating global interrupt and barrier signals for controlling global asynchronous operations performed by processing elements at selected processing nodes of a computing structure in accordance with a processing algorithm; and includes the physical interconnecting of the processing nodes for communicating the global interrupt and barrier signals to the elements via low-latency paths. The global asynchronous signals respectively initiate interrupt and barrier operations at the processing nodes at times selected for optimizing performance of the processing algorithms. In one embodiment, the global interrupt and barrier network is implemented in a scalable, massively parallel supercomputing device structure comprising a plurality of processing nodes interconnected by multiple independent networks, with each node including one or more processing elements for performing computation or communication activity as required when performing parallel algorithm operations. One multiple independent network includes a global tree network for enabling high-speed global tree communications among global tree network nodes or sub-trees thereof. The global interrupt and barrier network may operate in parallel with the global tree network for providing global asynchronous sideband signals.

Blumrich, Matthias A↗

Method for the rapid synthesis of large quantities of metal oxide nanowires at low temperatures

A process for the rapid synthesis of metal oxide nanoparticles at low temperatures and methods which facilitate the fabrication of long metal oxide nanowires. The method is based on treatment of metals with oxygen plasma. Using oxygen plasma at low temperatures allows for rapid growth unlike other synthesis methods where nanomaterials take a long time to grow. Density of neutral oxygen atoms in plasma is a controlling factor for the yield of nanowires. The oxygen atom density window differs for different materials. By selecting the optimal oxygen atom density for various materials the yield can be maximized for nanowire synthesis of the metal.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-I-60: The Correct Selection of Pitch and Rotation Time for Optimal CT Scanning : The Big Misconception

Purpose: To provide correct guidance in the proper selection of pitch and rotation time for optimal CT imaging with multi-slice scanners. Methods: There exists a widespread misconception concerning the role of pitch in patient dose with modern multi-slice scanners, particularly with the use of mA modulation techniques. We investigated the relationship of pitch and rotation time to image quality, dose, and scan duration, with CT scanners from different manufacturers in a way that clarifies this misconception. This source of this misconception may concern the role of pitch in single slice CT scanners. Results: We found that the image noise and dose are generally independent of the selected effective mAs (mA*time/ pitch) with manual mA technique settings and are generally independent of the selected pitch and /or rotation time with automatic mA modulation techniques. However we did find that on certain scanners the use of a pitch just above 0.5 provided images of equal image noise at a lower dose compared to the use of a pitch just below 1.0. Conclusion: The misconception that the use of a lower pitch over-irradiates patients by wasting dose is clearly false. The use of a lower pitch provides images of equal or better image quality at the same patient dose, whether using manual mA or automatic mA modulation techniques. By decreasing the pitch and the rotation times by equal amounts, both helical and patient motion artifacts can be reduced without affecting the exam time. The use of lower helical pitch also allows better scanning of larger patients by allowing a greater scan effective mAs, if the exam time can be extended. The one caution with the use of low pitch is not related to patient dose, but to the length of the scan time if the rotation time is not set short enough. Partial Research funding from GE HealthCare.

60 APPLIED LIFE SCIENCES↗

Linear Regression Model for Predictive Service Provider Selection

The increasing number of satellites in orbit has led to a growing reliance on third-party service providers for data transfer between Earth and space. Traditional approaches to managing satellite communications require human intervention, which becomes more burdensome with the escalating number of satellites. This research addresses the need for an efficient and automated system to optimize service provider selection for NASA space communication. Previous research has utilized human-operated approaches for service provider management. Our study fills a gap by developing a cognitive algorithm that automates and optimizes the selection process based on various parameters, such as data volume, priority, quality of service and cost. This novel solution reduces user burden, facilitates service management, and contributes to the development of cognitive spaceflight missions, ultimately supporting NASA’s research into Cognitive Communications technology. The algorithm design consists of three major steps: modeling data, developing a Link Selection Algorithm (LSA) based on a grading system, and applying machine learning using linear regression. The LSA evaluates providers based on user-defined constraints, considering factors such as delivery time, cost, and quality of service. We define a suitability metric which allows our algorithm to make a recommendation to a user regarding which commercial service providers to select. The addition of Linear Regression predicts the future suitability value. Our main findings demonstrate that the resulting algorithm can autonomously manage connections between satellites and providers, maximizing communication channel efficiency. This research has significant implications, as it not only addresses a pressing issue in satellite communication management but also advances the field of cognitive spaceflight missions.

Linear regression↗

Distributed Space Mission Design for Earth Observation Using Model-Based Performance Evaluation

Distributed Space Missions (DSMs) are gaining momentum in their application to earth observation missions owing to their unique ability to increase observation sampling in multiple dimensions. DSM design is a complex problem with many design variables, multiple objectives determining performance and cost and emergent, often unexpected, behaviors. There are very few open-access tools available to explore the tradespace of variables, minimize cost and maximize performance for pre-defined science goals, and therefore select the most optimal design. This paper presents a software tool that can multiple DSM architectures based on pre-defined design variable ranges and size those architectures in terms of predefined science and cost metrics. The tool will help a user select Pareto optimal DSM designs based on design of experiments techniques. The tool will be applied to some earth observation examples to demonstrate its applicability in making some key decisions between different performance metrics and cost metrics early in the design lifecycle.

Constellation↗

Automatic CT simulation optimization for radiation therapy: A general strategy

Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43–58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. Conclusions: A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target tracking via recursive Bayesian state estimation in cognitive radar networks

To cope with complicated environments and stealthier targets, incorporating intelligence and cognition cycles into target tracking is of great importance in modern sensor network management. With remarkable advances in sensor techniques and deployable platforms, a sensing system has freedom to select a subset of available radars, plan their trajectories, and transmit designed waveforms. In this paper, we propose a general framework for single target tracking in cognitive networks of radars, including consideration of waveform design, path planning, and radar selection, which are separately but not jointly taken into account in existing work. The tracking procedure, built on the theories of dynamic graphical models (DGM) and recursive Bayesian state estimation (RBSE), is formulated as two iterative steps: (i) solving a combinatorial optimization problem to select the optimal subset of radars, waveforms, and locations for the next tracking instant, and (ii) acquiring the recursive Bayesian state estimation to accurately track the target. Further, an illustrative example introduces a specific scenario in 2-D space. Simulation results based on the scenario demonstrate that the proposed framework can accurately track the target under the management of the network of radars.

47 OTHER INSTRUMENTATION↗

Selective recovery of silver from waste low-temperature co-fired ceramic and valorization through silver nanoparticle synthesis

Highlights: • Silver rich LTCC an e-waste has been recycled and valorized. • Selectively, Ag was leached and recovered as nanopowder. • The process can circulate the Ag within the industry in a close loop. • Brings back the material to production stream and address the circular economy. • Can be part of cradle-to-cradle technology and lower the futuristic carbon economy. - Abstract: Considering the value of silver metal and silver nanoparticles, the waste generated during manufacturing of low temperature co-fired ceramic (LTCC) were recycled through the simple yet cost effective process by chemical-metallurgy. Followed by leaching optimization, silver was selectively recovered through precipitation. The precipitated silver chloride was valorized though silver nanoparticle synthesis by a simple one-pot greener synthesis route. Through leaching-precipitation optimization, quantitative selective recovery of silver chloride was achieved, followed by homogeneous pure silver nanoparticle about 100 nm size were synthesized. The reported recycling process is a simple process, versatile, easy to implement, requires minimum facilities and no specialty chemicals, through which semiconductor manufacturing industry can treat the waste generated during manufacturing of LTCC and reutilize the valorized silver nanoparticles in manufacturing in a close loop process. Our reported process can address issues like; (i) waste disposal, as well as value-added silver recovery, (ii) brings back the material to production stream and address the circular economy, and (iii) can be part of lower the futuristic carbon economy and cradle-to-cradle technology management, simultaneously.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of optimization to predict the effect of selected parameters on commuter aircraft performance

The relationships between field length and cruise speed and aircraft direct operating cost were determined. A gradient optimizing computer program was developed to minimize direct operating cost (DOC) as a function of airplane geometry. In this way, the best airplane operating under one set of constraints can be compared with the best operating under another. A constant 30-passenger fuselage and rubberized engines based on the General Electric CT-7 were used as a baseline. All aircraft had to have a 600 nautical mile maximum range and were designed to FAR part 25 structural integrity and climb gradient regulations. Direct operating cost was minimized for a typical design mission of 150 nautical miles. For purposes of C sub L sub max calculation, all aircraft had double-slotted flaps but with no Fowler action.

Wells, V. L.↗

Selection of a Pair of Experiments to Optimally Reduce Uncertainty in Targeted Nuclear Data

We propose a novel process to select a pair of differential and integral experiments that best reduce uncertainties in targeted 239 ⁢Pu nuclear data while compressing the current nuclear data pipeline from 20 to 3 years. 239⁢ Pu nuclear data are poorly understood for neutrons in the intermediate energy range due to sparsity and uncertainty in historical experiments. New experiments targeting this range will enable better understanding of these nuclear data, but choosing the ideal experiments to conduct is challenging. Beginning with a prior distribution represented by samples of nuclear data generated from theory, generalized least squares adjustments are made to incorporate data from historical experiments. To quantify potential uncertainty reduction obtainable from a pair of candidate experiments, we compute the D-optimality criterion of the posterior covariance of intermediate energy range nuclear data compared to the equivalent covariance after additional adjustment to the pair of candidate experiments. Repeating the process for each of many candidate pairs facilitates the final selection. Results support 63⁢ Cu total cross section measurements for differential experiments and alumina and alumina/graphite configurations for integral experiments. This analysis enables choosing differential and integral experiments to be executed concurrently while shortening decision times relative to the current nuclear data pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multidisciplinary Optimization of a Transport Aircraft Wing using Particle Swarm Optimization

The purpose of this paper is to demonstrate the application of particle swarm optimization to a realistic multidisciplinary optimization test problem. The paper's new contributions to multidisciplinary optimization is the application of a new algorithm for dealing with the unique challenges associated with multidisciplinary optimization problems, and recommendations as to the utility of the algorithm in future multidisciplinary optimization applications. The selected example is a bi-level optimization problem that demonstrates severe numerical noise and has a combination of continuous and truly discrete design variables. The use of traditional gradient-based optimization algorithms is thus not practical. The numerical results presented indicate that the particle swarm optimization algorithm is able to reliably find the optimum design for the problem presented here. The algorithm is capable of dealing with the unique challenges posed by multidisciplinary optimization as well as the numerical noise and truly discrete variables present in the current example problem.

Sobieszczanski-Sobieski, Jaroslaw↗

Launch Vehicle Propulsion Parameter Design Multiple Selection Criteria

The optimization tool described herein addresses and emphasizes the use of computer tools to model a system and focuses on a concept development approach for a liquid hydrogen/liquid oxygen single-stage-to-orbit system, but more particularly the development of the optimized system using new techniques. This methodology uses new and innovative tools to run Monte Carlo simulations, genetic algorithm solvers, and statistical models in order to optimize a design concept. The concept launch vehicle and propulsion system were modeled and optimized to determine the best design for weight and cost by varying design and technology parameters. Uncertainty levels were applied using Monte Carlo Simulations and the model output was compared to the National Aeronautics and Space Administration Space Shuttle Main Engine. Several key conclusions are summarized here for the model results. First, the Gross Liftoff Weight and Dry Weight were 67% higher for the design case for minimization of Design, Development, Test and Evaluation cost when compared to the weights determined by the minimization of Gross Liftoff Weight case. In turn, the Design, Development, Test and Evaluation cost was 53% higher for optimized Gross Liftoff Weight case when compared to the cost determined by case for minimization of Design, Development, Test and Evaluation cost. Therefore, a 53% increase in Design, Development, Test and Evaluation cost results in a 67% reduction in Gross Liftoff Weight. Secondly, the tool outputs define the sensitivity of propulsion parameters, technology and cost factors and how these parameters differ when cost and weight are optimized separately. A key finding was that for a Space Shuttle Main Engine thrust level the oxidizer/fuel ratio of 6.6 resulted in the lowest Gross Liftoff Weight rather than at 5.2 for the maximum specific impulse, demonstrating the relationships between specific impulse, engine weight, tank volume and tank weight. Lastly, the optimum chamber pressure for Gross Liftoff Weight minimization was 2713 pounds per square inch as compared to 3162 for the Design, Development, Test and Evaluation cost optimization case. This chamber pressure range is close to 3000 pounds per square inch for the Space Shuttle Main Engine.

Shelton, Joey Dewayne↗

Achieving High Selectivity for Alkyne Hydrogenation at High Conversions with Compositionally Optimized PdAu Nanoparticle Catalysts in Raspberry Colloid-Templated SiO 2

Improving the selectivity for catalytic hydrogenation of alkynes is a key step in upgrading feedstocks for olefin polymerization. Herein, dilute Pd x Au 1-x alloy nanoparticles embedded in raspberry colloidtemplated silica (x = 0.02, 0.04, and 0.09) are demonstrated to be highly active and selective for the gas-phase hydrogenation of 1-hexyne, exhibiting higher selectivity than pure Pd at high conversion. The conversion of 1-hexyne remains high even for the very low amounts of Pd in Pd 0.02 Au 0.98 . These catalysts are highly resistant to sintering—addressing a long-standing challenge in the use of Au-based catalysts. Clear evidence is presented that the addition of the second hydrogen to the halfhydrogenated intermediate is the rate-limiting step, and that the stability of the half-hydrogenated intermediate of the alkyne is higher than the half-hydrogenated alkene which explains the high selectivity even at high conversions. Moreover, of the three compositions investigated, optimum selectivity and activity is observed for the nanoparticles containing 4% Pd. The apparent activation energy for production of 1-hexene from 1-hexyne is measured to be 38 kJ mol -1 for the Pd 0.04 Au 0.96 catalysts, which is ~14 kJ mol -1 lower than for pure Pd. The hydrogenation is completely, but reversibly, suppressed by adding CO to the reactant mixture, indicating that the Pd centers are the active sites for reaction. The method of templating used in preparation of the catalysts is highly customizable and versatile. As a result, this study demonstrates that the composition of the nanoparticles as defined by the dilution ratio of Pd in Au and by the method used to make the supported catalyst are important tunable parameters that can be used to optimize activity and selectivity of bimetallic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Intelligent System for Automatic Selection of DC-DC Converter Topology with Optimal Design

In this paper, we present an intelligent system that has the capabilities of automatically selecting topology classes and optimizing circuit parameters of DC-DC power converters for a given design specification. The system, Machine-Learning-enhanced Automated Circuit Configuration and Evaluation of Power Converters (ML-ACCEPT), uses a hybrid of machine learning technologies, decision tree inference, reinforcement learning and deep neural networks. The system gives high accurate recommendations of design topology classes and computationally efficient results in optimizing power efficiencies in power converter design.

Xue, Lincoln↗

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Communication Topology Determination and Sensor Selection for Independent Airspace Surveillance

The paper presents an approach to sensors selection and network topology determination for independent airspace surveillance with maximum outcome and minimum cost using ground based distributed sensing, computing and communication network infrastructure. The selection criteria includes minimum estimation error, maximum airspace coverage, minimum communication time and power consumption while guaranteeing the system observability and providing in-time quality information to a monitoring observer. The developed algorithm uses multi-objective optimization strategy taking into account trade-offs between conflicting objectives and relaxations for in time implementation. It is implemented utilizing graph theoretic tools. The approach is validated in a desktop simulation environment using synthetic sensors data generated for a simulated multi-vehicle flight scenario in the selected regional airspace.

Distributed sensing↗

SolOpt: A Novel Approach to Solar Rooftop Optimization

Traditionally Photovoltaic Technology (PV) and Solar Hot Water Technology (SHW) have been designed with separate design tools, making it difficult to determine the appropriate mix of PV and SHW. A new tool developed at the National Renewable Energy Laboratory changes how the analysis is conducted through an integrated approach based on the life cycle cost effectiveness of each system. With 10 inputs someone with only basic knowledge of the building can simulate energy production from PV and SHW, and predict the optimal sizes of the systems. The user can select from four optimization criteria currently available: Greenhouse Gas Reduction, Net-Present Value, Renewable Energy Production, and Discounted Payback Period. SolOpt provides unique analysis capabilities that aren't currently available in any other software programs. Validation results with industry accepted tools for both SHW and PV are presented.

14 SOLAR ENERGY↗