Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Replaceable Sensor System for Bioreactor Monitoring

A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

Mayo, Mike↗

Copilot: Monitoring Embedded Systems

Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

Pike, Lee↗

Flight Demonstration of X-33 Vehicle Health Management System Components on the F/A-18 Systems Research Aircraft

The X-33 reusable launch vehicle demonstrator has identified the need to implement a vehicle health monitoring system that can acquire data that monitors system health and performance. Sanders, a Lockheed Martin Company, has designed and developed a commercial off-the-shelf (COTS)-based open architecture system that implements a number of technologies that have not been previously used in a flight environment. NASA Dryden Flight Research Center and Sanders teamed to demonstrate that the distributed remote health nodes, fiber optic distributed strain sensor, and fiber distributed data interface communications components of the X-33 vehicle health management (VHM) system could be successfully integrated and flown on a NASA F-18 aircraft. This paper briefly describes components of X-33 VHM architecture flown at Dryden and summarizes the integration and flight demonstration of these X-33 VHM components. Finally, it presents early results from the integration and flight efforts.

Schweikhard, Keith A.↗

Flight Demonstration of X-33 Vehicle Health Management System Components on the F/A-18 Systems Research Aircraft

The X-33 reusable launch vehicle demonstrator has identified the need to implement a vehicle health monitoring system that can acquire data that monitors system health and performance. Sanders, a Lockheed Martin Company, has designed and developed a COTS-based open architecture system that implements a number of technologies that have not been previously used in a flight environment. NASA Dryden Flight Research Center and Sanders teamed to demonstrate that the distributed remote health nodes, fiber optic distributed strain sensor, and fiber distributed data interface communications components of the X-33 vehicle health management (VHM) system could be successfully integrated and flown on a NASA F-18 aircraft. This paper briefly describes components of X-33 VHM architecture flown at Dryden and summarizes the integration and flight demonstration of these X-33 VHM components. Finally, it presents early results from the integration and flight efforts.

Schweikhard, Keith A.↗

E Tunnel Wastewater Disposal System Quarterly Monitoring Report Nevada National Security Site, Nevada Water Pollution Control Permit NEV 96021, Second Quarter 2018

This report includes the results of the E Tunnel Wastewater Disposal System (ETDS) inspections and monitoring for April, May and June 2018. Monitoring and sampling activities were performed in accordance with the requirements of Water Pollution Control Permit NEV 96021, Revision 1, effective October 1, 2013.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-76: A Software System to Monitor VMAT Plan Complexity in a Large Radiotherapy Centre

Purpose: To develop a system that analyses and reports the complexity of Volumetric Modulated Arc Therapy (VMAT) plans to aid in the decision making for streamlining patient specific dosimetric quality assurance (QA) tests. Methods: A software system, Delcheck, was developed in-house to calculate VMAT plan and delivery complexity using the treatment delivery file. Delcheck has the functionality to calculate multiple plan complexity metrics including the Li-Xing Modulation Index (LI-MI), multiplicative combination of Leaf Travel and Modulation Complexity Score (LTMCSv), Monitor Units per prescribed dose (MU/D) and the delivery complexity index (MIt) that incorporates the modulation of dose rate, leaf speed and gantry speed. Delcheck includes database functionality to store and compare plan metrics for a specified treatment site. The overall plan and delivery complexity is assessed based on the 95% conformance limit of the complexity metrics as Similar, More or Less complex. The functionality of the software was tested using 42 prostate conventional, 10 prostate SBRT and 15 prostate bed VMAT plans generated for an Elekta linear accelerator. Results: The mean(σ) of LI-MI for conventional, SBRT and prostate bed plans were 1690(486), 3215.4(1294) and 3258(982) respectively. The LTMCSv of the studied categories were 0.334(0.05), 0.325(0.07) and 0.3112(0.09). The MU/D of the studied categories were 2.4(0.4), 2.7(0.7) and 2.5(0.5). The MIt of the studied categories were 21.6(3.4), 18.2(3.0) and 35.9(6.6). The values of the complexity metrics show that LI-MI appeared to resolve the plan complexity better than LTMCSv and MU/D. The MIt value increased as the delivery complexity increased. Conclusion: The developed software was shown to be working as expected. In studied treatment categories Prostate bed plans are more complex in both plan and delivery and SBRT is more complex in plan and less complex in delivery as demonstrated by LI-MI and MIt. This project was funded through a Cancer Council NSW Project Grant (RG14-11)

60 APPLIED LIFE SCIENCES↗

On-line, continuous monitoring in solar cell and fuel cell manufacturing using spectral reflectance imaging

A monitoring system 100 comprising a material transport system 104 providing for the transportation of a substantially planar material 102, 107 through the monitoring zone 103 of the monitoring system 100. The system 100 also includes a line camera 106 positioned to obtain multiple line images across a width of the material 102, 107 as it is transported through the monitoring zone 103. The system 100 further includes an illumination source 108 providing for the illumination of the material 102, 107 transported through the monitoring zone 103 such that light reflected in a direction normal to the substantially planar surface of the material 102, 107 is detected by the line camera 106. A data processing system 110 is also provided in digital communication with the line camera 106. The data processing system 110 is configured to receive data output from the line camera 106 and further configured to calculate and provide substantially contemporaneous information relating to a quality parameter of the material 102, 107. Also disclosed are methods of monitoring a quality parameter of a material.

14 SOLAR ENERGY↗

Melt pool instability detection using coaxial photodiode system validated by in-situ X-ray imaging

A co-axial photodiode monitoring system with high temporal resolution has been integrated into a proven test bench enabling synchronized side-view high speed X-ray imaging of melt pool dynamics and top-view spectral emission characterization of the melt pool. Here, this setup enables direct observation of melt pool phenomena and correlation between the two monitoring systems which can be directly scaled to commercial systems. The work demonstrates a 92% detection rate in keyhole collapse phenomena related to defect generation in SLM. Furthermore, the impact of gas flow on monitoring signals is studied to understand the fundamental importance of gas flow in commercial systems.

36 MATERIALS SCIENCE↗

Information-Driven Inspections

New uranium enrichment capacity is being built worldwide in response to perceived shortfalls in future supply. To meet increasing safeguards responsibilities with limited resources, the nonproliferation community is exploring next-generation concepts to increase the effectiveness and efficiency of safeguards, such as advanced technologies to enable unattended monitoring of nuclear material. These include attribute measurement technologies, data authentication tools, and transmission and security methods. However, there are several conceptual issues with how such data would be used to improve the ability of a safeguards inspectorate such as the International Atomic Energy Agency (IAEA) to reach better safeguards conclusions regarding the activities of a State. The IAEA is pursuing the implementation of information-driven safeguards, whereby all available sources of information are used to make the application of safeguards more effective and efficient. Data from continuous, unattended monitoring systems can be used to optimize on-site inspection scheduling and activities at declared facilities, resulting in fewer, better inspections. Such information-driven inspections are the logical evolution of inspection planning - making use of all available information to enhance scheduled and randomized inspections. Data collection and analysis approaches for unattended monitoring systems can be designed to protect sensitive information while enabling information-driven inspections. A number of such inspections within a predetermined range could reduce inspection frequency while providing an equal or greater level of deterrence against illicit activity, all while meeting operator and technology holder requirements and reducing inspector and operator burden. Three options for using unattended monitoring data to determine an information-driven inspection schedule are to (1) send all unattended monitoring data off-site, which will require advances in data analysis techniques to determine optimal thresholds; (2) have all separate unattended systems send individual go/no-go signals, allowing the inspectorate to know exactly which systems are exceeding their thresholds; and (3) develop a data aggregation system with attribute monitoring algorithms that would send a single go/no-go or other status signal off-site. Since the data in all of these options are used to inform on-site inspections (which will revert to randomized inspections if no thresholds are reached), the thresholds for the unattended systems can be set much closer to declared operating parameters than in current unattended monitoring systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Causal modeling and event-driven simulation for monitoring of continuous systems

We describe extensions to the traditional techniques for anomaly detection, as well as new anomaly detection techniques based on alternate models of what distinguishes normal from abnormal behavior. Some of these techniques are designed to capture anomalies at individual sensors; some detect anomalies across collections of sensors. To assist in reasoning about complex global behaviors, we construct and simulate a causal model of the physical system being monitored. These techniques have been tested on data from the ECLSS of Space Station Freedom (SSF) and are being applied in advanced monitoring prototypes for the SSF External Active Thermal Control System of SSF and the Environmental Emergency and Consumables Management subsystem of the Space Shuttle.

Doyle, Richard↗

Automation-induced monitoring inefficiency: role of display location

Operators can be poor monitors of automation if they are engaged concurrently in other tasks. However, in previous studies of this phenomenon the automated task was always presented in the periphery, away from the primary manual tasks that were centrally displayed. In this study we examined whether centrally locating an automated task would boost monitoring performance during a flight-simulation task consisting of system monitoring, tracking and fuel resource management sub-tasks. Twelve nonpilot subjects were required to perform the tracking and fuel management tasks manually while watching the automated system monitoring task for occasional failures. The automation reliability was constant at 87.5% for six subjects and variable (alternating between 87.5% and 56.25%) for the other six subjects. Each subject completed four 30 min sessions over a period of 2 days. In each automation reliability condition the automation routine was disabled for the last 20 min of the fourth session in order to simulate catastrophic automation failure (0 % reliability). Monitoring for automation failure was inefficient when automation reliability was constant but not when it varied over time, replicating previous results. Furthermore, there was no evidence of resource or speed accuracy trade-off between tasks. Thus, automation-induced failures of monitoring cannot be prevented by centrally locating the automated task.

Automation↗

A review of the developments of radioxenon detectors for nuclear explosion monitoring

Developments in radioxenon monitoring since the implementation of the International Monitoring System are reviewed with emphasis on the most current technologies to improve detector sensitivity and resolution. The nuclear detectors reviewed include combinations of plastic and NaI(Tl) detectors, high purity germanium detectors, silicon detectors, and phoswich detectors. The minimum detectable activity and calibration methods for the various detectors are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Early Warning Techniques

Contemporary approaches to aerospace vehicle system monitoring rely heavily on thresholds that represent a compromise between providing warning early enough to avert a mishap while simultaneously minimizing false alarms. While this reliance on thresholds has been in place for decades and has permeated both cockpits and control rooms, we often find it insufficient when retrospectively analyzing data from an accident. To modernize and enhance flight test safety, we introduce new methods of monitoring for anomalous patterns of interaction rather than for thresholds exceedance. For systems with a well characterized baseline we show how the Inductive Monitoring System (IMS), utilized by NASA in the aftermath of the Columbia accident, might be implemented in real-time to provide earlier warning than currently employed techniques. For systems without such a baseline, we introduce new developments in statistical methods relating to critical slowing down, first applied in medicine and physics, which show promise for adaptation to flight test. Finally, the familiar resource constrained environment leads to a reliance on increased instrumentation that is challenging the limits of the current one-sensor, one-indicator threshold paradigm. Existing methods thus fail to accurately reflect the true complexity of a vehicle rich with interdependent interacting systems. We highlight these concepts in a brief summary of the 2001 Air Transat Flight 236 deadstick landing in the Azores. We then suggest control room and cockpit modifications to better display the information gleaned using these novel monitoring methods.

Javorsek, Dan↗

Enhancing Flight Test Safety with Real-Time Early Warning Techniques

Contemporary approaches to aerospace vehicle system monitoring rely heavily on thresholds that represent a compromise between providing warning early enough to avert a mishap while simultaneously minimizing false alarms. While this reliance on thresholds has been in place for decades and has permeated both cockpits and control rooms, we often find it insufficient when retrospectively analyzing data from an accident. To modernize and enhance flight test safety, we introduce new methods of monitoring for anomalous patterns of interaction rather than for thresholds exceedance. For systems with a well characterized baseline we show how the Inductive Monitoring System (IMS), utilized by NASA in the aftermath of the Columbia accident, might be implemented in real-time to provide earlier warning than currently employed techniques. For systems without such a baseline, we introduce new developments in statistical methods relating to critical slowing down, first applied in medicine and physics, which show promise for adaptation to flight test. Finally, the familiar resource constrained environment leads to a reliance on increased instrumentation that is challenging the limits of the current "one-sensor, one-indicator" threshold paradigm. Existing methods thus fail to accurately reflect the true complexity of a vehicle rich with interdependent interacting systems. We highlight these concepts in a brief summary of the 2001 Air Transat Flight 236 deadstick landing in the Azores. We then suggest control room and cockpit modifications to better display the information gleaned using these novel monitoring methods.

Javorsek, Daniel, II↗

Respiratory motion management in particle therapy

Clinical outcomes of charged particle therapy are very promising. Currently, several dedicated centers that use scanning beam technology are either close to clinical use or under construction. Since scanned beam treatments of targets that move with respiration most likely result in marked local over- and underdosage due to interplay of target motion and dynamic beam application, dedicated motion mitigation techniques have to be employed. To date, the motion mitigation techniques, rescanning, beam gating, and beam tracking, have been proposed and tested in experimental studies. Rescanning relies on repeated irradiations of the target with the number of particles reduced accordingly per scan to statistically average local misdosage. Specific developments to prohibit temporal correlation between beam scanning and target motion will be required to guarantee adequate averaging. For beam gating, residual target motion within gating windows has to be mitigated in order to avoid local misdosage. Possibly the most promising strategy is to increase the overlap of adjacent particle pencil beams laterally as well as longitudinally to effectively reduce the sensitivity against small residual target motion. The most conformal and potentially most precise motion mitigation technique is beam tracking. Individual particle pencil beams have to be adapted laterally as well as longitudinally according to the target motion. Within the next several years, it can be anticipated that rescanning as well as beam gating will be ready for clinical use. For rescanning, treatment planning margins that incorporate the full extent of target motion as well as motion induced density variations in the beam paths will result in reduced target conformity of the applied dose distributions. Due to the limited precision of motion monitoring devices, it seems likely that beam gating will be used initially to mitigate interplay effects only but not to considerably decrease treatment planning margins. Then, in the next step, beam gating, based on more accurate motion monitoring systems, provides the possibility to restore target conformity as well as steep dose gradients due to reduced treatment planning margins. Accurate motion monitoring systems will be required for beam tracking. Even though beam tracking has already been successfully tested experimentally, full clinical implementation requires direct feedback of the actual target position in quasireal time to the treatment control system and can be anticipated to be several more years ahead.

61 RADIATION PROTECTION AND DOSIMETRY↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗