Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHEATH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MINI PCNL in a Pediatric Population

We report our initial experience of MINI percutaneous nephrolithotomy (PCNL) in a pediatric population using a miniature nephroscope through a 16F metal access sheath. All pediatric patients who underwent PCNL from August 2007 to September 2010 using a 14F miniature nephroscope through a 16F metal access sheath for renal stone extraction were evaluated. Patients' demographic details, procedural information, and posttreatment outcomes were prospectively documented. A total of 23 MINI PCNLs were performed on 23 kidneys of 12 patients whose ages ranged from 1.6 to 14.6 years. The median stone burden was 3.44 cm{sup 2}, and there were 11 'Staghorn' stones. The procedure was primary via a single puncture in 19 kidneys and secondary using a preexisting nephrostomy tract in 4 kidneys. Access was successful in all primary and two secondary cases, for a total of success rate of 91.3%. Stones were fragmented using a Holmium laser and/or lithoclast, and fragments were irrigated or sequentially removed by various stone grasping devices. The mean procedural X-ray screening time and total stone extraction period were 4.5 and 109.4 min, respectively. The primary stone free rate was 83.6 %, which increased to 90.5 % after treating the residual fragments. Postoperative hydrothorax developed in one patient, which required a chest drain. Symptoms of chest infection and positive urine culture were detected in one and two patients, respectively. Our initial experience supports previous reports that MINI PCNL is safe and effective for the management of renal stones in children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Profunda Anchor Technique for Ipsilateral Antegrade Approach in Endovascular Treatment of Superficial Femoral Artery Ostial Occlusion

Endovascular treatment of the superficial femoral artery (SFA) is challenging in the presence of flush ostial occlusion. One of the main challenges is the availability of access sites for intervention. Contralateral retrograde femoral access followed by cross-over and antegrade intervention while commonly used, may not be feasible in cases of altered iliac anatomy (e.g. kissing iliac stents). Ipsilateral antegrade intervention using common femoral artery (CFA) access in these instances while possible is typically challenging due to inadequate working length of the CFA for interrogation of the SFA ostium, compounded by the lack of sheath stability. The “profunda anchor” technique uses a buddy wire in the profunda femoris artery (PFA) to stabilize the sheath and allow catheter manipulation for antegrade intervention at the level of the SFA ostium. The PFA is further used as a conduit for deployment of closure device to avoid interference with the treated SFA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filters was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restoration of Dehiscent Pancreaticojejunostomy Causing a Major Postoperative Pancreatic Fistula by Reinsertion of a Pancreatic Duct Tube Using the Rendezvous Technique

Introduction: A postoperative clinically relevant pancreatic fistula can cause severe sequelae. We aimed to describe our minimally invasive procedure (rendezvous technique) for the treatment of a pancreatic fistula resulting from pancreaticojejunal anastomosis dehiscence involving a dislodged main pancreatic duct tube. Methods: In our rendezvous technique, a guidewire is advanced into the jejunal lumen from the access site of the drainage tube and is caught by a snare catheter, which is used to replace the dislodged main pancreatic duct tube. Then, the guidewire is passed from the access site of the drainage tube to the site of the dislodged main pancreatic duct tube. A sheath is inserted along the route of the dislodged main pancreatic duct tube and is placed across the pancreaticojejunal anastomosis over the guidewire. Another guidewire is advanced into the main pancreatic duct via the sheath, and a new main pancreatic duct tube is inserted into the main pancreatic duct over the second wire. This technique was performed in two patients with a pancreatic fistula. Results: Our rendezvous technique was successfully performed in a 73-year-old man with an intractable clinically relevant pancreatic fistula and large discharge from the drain and a 74-year-old woman with a pancreatic fistula and fluid collection between the elevated jejunum and remnant pancreas. Discharge from the drain and fluid collection decreased after the procedure. Conclusion: Our rendezvous technique is an effective minimally invasive approach for a pancreatic fistula resulting from pancreaticojejunal anastomosis dehiscence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24

A series of experiments were carried out using the middle energy (dense) plasma focus device PF-24 with deuterium as a working gas under pressure in a range between 2 and 5 mbar for 17 kV of charging voltage. The relationship between these operating deuterium pressures in reference to the total neutron yield (Y{sub n}) was estimated. The 5-phase Lee code was used to simulate the measured discharge current and neutron yield (Y{sub n}) using a phenomenological beam-target neutron generating mechanism, which was incorporated in the model. Comparison of the Y{sub n} versus pressure using fitted model parameters was made at each point of pressure. The good agreement between measured and computed Y{sub n} values was achieved for discharges with lower neutron emission. The measured Y{sub n} (below 2.6 × 10{sup 9} n/discharge—the median value) has been reproducible by the model for 73% of simulated discharges, while above the median value its prediction were incorrect. The kinetic plasma parameters which were measured and computed using the Lee code for different pressures are: the time to a current sheath collapse (t{sub c}), the average axial current sheath velocity (v{sub z}) and the so called velocity factor (RF). Good agreement was found in the whole range of deuterium pressures between the computed and measured results for these kinematic quantities. Presented findings in this work suggest that the character of neutron emission is more complex than it would seem from classical interpretation of neutron production based on a beam-target model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiscale characterization of chemical–mechanical interactions between polymer fibers and cementitious matrix

Together with a series of mechanical tests, the interactions and potential bonding between polymeric fibers and cementitious materials were studied using scanning transmission X-ray microscopy (STXM) and microtomography (lCT). Experimental results showed that these techniques have great potential to characterize the polymer fiber-hydrated cement-paste matrix interface, as well as differentiating the chemistry of the two components of a bi-polymer (hybrid) fiber the polypropylene core and the ethylene acrylic acid copolymer sheath. Similarly, chemical interactions between the hybrid fiber and the cement hydration products were observed, indicating the chemical bonding between the sheath and the hardened cement paste matrix. Microtomography allowed visualization of the performance of the samples, and the distribution and orientation of the two types of fiber in mortar. Beam flexure tests confirmed improved tensile strength of mixes containing hybrid fibers, and expansion bar tests showed similar reductions in expansion for the polypropylene and hybrid fiber mortar bars.

36 MATERIALS SCIENCE↗

Elucidating key reducing species beyond ions in hydrogen plasma smelting reduction of iron ore

Hydrogen plasma smelting reduction (HPSR) of iron ore has attracted significant attention over the past decade due to its high-temperature operation, rapid plasma mediated reduction kinetics, and simpler density-based separation of molten iron product, compared to H2-based solid-state reduction. All of these attributes enable processing of low-grade ores for downstream use in electric-arc furnaces, as virgin iron with low gangue content is required for high quality steel and improved furnace operation. While positive ions exist within the plasma arc, this work demonstrates that near the anodic ore surface, hydrogen radicals and vibrationally excited hydrogen species dominate and their densities correlate well with observed reduction rates. Species concentrations in the transferred plasma arc and at the plasma-ore interface are evaluated using coupled thermal plasma and near-wall non-equilibrium plasma models. The thermal plasma model is validated against experimental voltage data and spectroscopic measurements of plasma temperature and density for varying current inputs. Modeling of the near surface thermochemical non-equilibrium and micrometer scale anode sheath layer reveals, in addition to the expected H + , significant concentrations of ArH + and H$^+_3$ ions, typically not observed in thermal plasmas under thermodynamic equilibrium. Our results show that the inverted sheath structure at the anodic ore surface strongly suppresses reactive positive ion fluxes, while non-equilibrium electron-impact processes generate abundant hydrogen radicals and vibrationally excited species. These findings highlight the critical role of non-equilibrium effects in hydrogen arc-driven iron ore reduction and advance understanding beyond prevailing hypotheses centered on hydrogen ion-driven mechanisms.

08 HYDROGEN↗

Engineering mechanical and thermomechanical performance in additive manufacturing–Compression molded composites through multiplexed extrusion

Traditional extrusion-based additive manufacturing is limited to single material systems, restricting the multifunctional properties of composites. For this work to overcome this limitation, multiplexed additive manufacturing–compression molding (AM-CM) was employed to fabricate multi-material thermoplastic composites with spatially tailored architectures. Neat acrylonitrile butadiene styrene (ABS) and 20 wt% carbon-fiber reinforced ABS (CF-ABS) were co-extruded through a core–sheath nozzle to produce hybrid composites with neat ABS as sheath (30-50 wt%) and CF-ABS as core (50 – 70 wt%). The results show that the hybrid composites have balance of mechanical and thermomechanical performance. The tensile strength and modulus of hybrid composites exhibited a 61–95% and 173–473% increase compared to neat ABS with increases in CF-ABS content whereas the impact resistance improved by 41% compared to CF-ABS at 50 wt% ABS. Additionally, hybrid composites showed significant reduction (54 - 70%) in creep strain at 100 °C compared to neat ABS. These findings demonstrate that multiplexed AM-CM enables tunable structure–property relationships, reducing CF-ABS usage up to 50 wt% while maintaining balanced stiffness, toughness, and creep resistance.

Additive manufacturing↗

Experimental and theoretical study of the restrained shrinkage cracking of early age well cement

The shrinkage cracking occurring in oil & gas well cement material is a major factor that reduces the cement sheath integrity and impairs the durability of an underground well. Shrinkage mainly takes place in the early hydration period of the cement, and the resulting restrained shrinkage cracking can form a leaking network for oil & gas or carbon dioxide stored in an underground reservoir. It is thus important to understand the early age behavior of well cement and the leaking pathway formation in the well. This study describes the application of the digital image correlation (DIC) method as a tool to measure the strain development and crack distributions of well cement in the lab during early phase changes. A theoretical model is presented to calculate the stress distribution built up in the cement sheath during early ages of well cement hydration, which helps to interpret the experimental observations and determine the major factors influencing the cracking sequences. This study presents the whole hydration – drying shrinkage – and cracking mechanism of early age well cement under restrained ring conditions experimentally and theoretically. Finally, the results offer useful insights on the key material and geometric parameters which control the fracture of a well cementing structure.

36 MATERIALS SCIENCE↗

Calculation of two-dimension radial electric field in boundary plasmas by using BOUT++

The steady state radial electric field (Er) is measured by coupling a plasma transport model with the quasi-neutrality constraint and the vorticity equation within the BOUT++ framework. Due to the experimentally measured plasma density and temperature profiles in Alcator C-Mod discharges, the effective radial particle and heat diffusivities are inferred from the set of plasma transport equations. The effective diffusivities are then extended into the scrape-off layer (SOL) to calculate the plasma density, temperature and flow profiles across the separatrix into the SOL with the electrostatic sheath boundary conditions (SBC) applied on the divertor plates. Given these diffusivities, the electric field can be calculated self-consistently across the separatrix from the vorticity equation with SBC coupled to the plasma transport equations. The sheath boundary conditions act to generate a large and positive Er in the SOL, which is consistent with experimental measurements. The effect of magnetic particle drifts is shown to play a significant role on local particle transport and Er by inducing a net particle flow in both the edge and SOL regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical probe diagnostics for the laminar flame quenching distance

A simplified theory, previously developed for the general case of weakly ionized gas flow, is used to predict electrical probe response when the flame is quenched on the probe surface. This theory is based on the planar model of space charge sheaths around the measuring electrode. For the flame quenching case, by assuming that the sheath thickness is comparable with the thermal boundary layer thickness, probe current can be related to flame quenching distance. The theoretical assumptions made to obtain the analytical formulation of probe current were experimentally proved by using direct visualization and high-frequency PIV. The direct visualization method was also used to validate the results of flame quenching distance values obtained with electrical probe. The electrical probe diagnostics have been verified for both head-on and sidewall flame quenching regimes and for stoichiometric methane/air and propane/air mixtures in a pressure range of 0.05-0.6 MPa. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-re-adhering alkali-activated cement composite and its ability to mitigate corrosion of carbon steel in 300 °C hydrothermal environment

Cement-steel interface is a weak point of cement sheath integrity under the environments of high-temperature geothermal wells. This paper presents carbon steel (CS) adherence behaviors of 300 °C-autoclaved alkali-activated Calcium-Aluminate-Cement (CAC)/fly ash F (FAF) (Thermal Shock Resistant Cement, TSRC), granulated blast furnace slag (GBFS)/SiO 2 , and Ordinary Portland Cement (OPC)/SiO 2 blends. The composites’ ability to preserve the bond under the conditions of thermal shock (TS) and strong acid attack (pH 0.6 H 2 SO 4 /brine at 90 °C) as well as their ability to recover the damaged bond and provide steel corrosion protection after additional short-time 5-day curing at 300 °C were evaluated. GBFS/SiO 2 sheath underwent catastrophic failure in the first TS cycle; OPC/SiO 2 lost 78 % and TSRC 51 % of the bond strength in 6 cycles. Only TSRC-CS bond survived 30 days of strong acid exposure; OPC/SiO 2 bond failed after 18 days and GBFS/SiO 2 after 20 days. Addition of micro-glass fibers (MGF) to TSRC further improved its bond strength and CS corrosion protection. Samples of TSRC-CS cured for 30 days at 300 °C before the bond damage recovered 49 % of the damaged bond strength after additional short-time curing. The CS protected by the re-adhered TSRC showed low corrosion rate of 0.13 mm/year (TSRC-MGF), 0.2 mm/year (TSRC) vs. 0.64 mm/year for OPC/SiO 2 protected CS.

15 GEOTHERMAL ENERGY↗

Embedded Sensors in Additively Manufactured Silicon Carbide

Silicon carbide (SiC) components are being considered for a wide range of nuclear applications due to their high-temperature strength retention, low neutron absorption, chemical inertness, and dimensional stability under neutron irradiation. However, machining and joining of SiC components have traditionally limited its application to relatively simple geometries. Recent work has demonstrated additive manufacturing of complex, high-purity, crystalline SiC components using a combination of binder jet printing and densification via chemical vapor infiltration (CVI). The process lends itself to embedding of fuel, absorbers, moderators, and sensors at strategic locations within a component. The latter could allow for enhanced in situ performance monitoring of limiting fuel temperatures, self-shielded neutron flux, and potentially spatially distributed strain within complex SiC components if sensors can be successfully embedded during CVI. This work describes (1) methods for embedding sensors; (2) thermodynamic analyses and material compatibility testing for identifying sensors capable of surviving high temperatures and exposure to hydrogen and hydrogen chloride during CVI; and (3) nuclear applications for embedded sensors, including potential failure modes during fabrication and during reactor operation. Molybdenum-sheathed thermocouples were successfully embedded in a complex SiC component, whereas niobium-sheathed high-temperature irradiation-resistant thermocouples started to drift as soon as the reactant gases were introduced and ultimately failed during CVI due to severe constrained expansion, potentially resulting from niobium hydride formation in the low-temperature region of the CVI system. Optical fibers were successfully embedded in SiC, but further work is needed to protect the fragile fiber leads after their protective coatings are removed during CVI.

thermocouples↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗