Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

TU-CD-304-09: Feasibility Study for Thermoplastic Mask Set Up Monitoring Using Force Sensing Resistor (FSR) Sensor

Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with a head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-T-525: Monitordeep-Inspiratory Breathhold with a Laser Sensor for Radiation Therapy of Left Breast Cancer

Purpose: Radiation therapy (RT) of left sided breast cancers with deep-inspiratory breathhold (DIBH) can reduce the dose to heart. The purpose of this study is to develop and test a new laser-based tool to improve ease of RT delivery using DIBH. Methods: A laser sensor together with breathing monitor device (Anzai Inc., Japan) was used to record the surface breathing motion of phantom/volunteers. The device projects a laser beam to the chestwall and the reflected light creates a focal spot on a light detecting element. The position change of the focal spot correlates with the patient’s breathing motion and is measured through the change of current in the light detecting element. The signal is amplified and displayed on a computer screen, which is used to trigger radiation gating. The laser sensor can be easily mounted to the simulation/treatment couch with a fixing plate and a magnet base, and has a sensitivity range of 10 to 40 cm from the patient. The correlation of breathing signals detected by laser sensor and visionRT is also investigated. Results: It is found that the measured breathing signal from the laser sensor is stable and reproducible and has no noticeable delay. It correlates well with the VisionRT surface imaging system. The DIBH reference level does not change with movement of the couch because the laser sensor and couch move together. Conclusion: The Anzai laser sensor provides a cost-effective way to improve beam gating with DIBH for treating left breast cancer. It can be used alone or together with VisionRT to determine the correct DIBH level during the radiation treatment of left breast cancer with DIBH.

60 APPLIED LIFE SCIENCES↗

xGFabric: Coupling Sensor Networks and HPC Facilities with Private 5G Wireless Networks for Real-Time Digital Agriculture

Advanced scientific applications require coupling distributed sensor networks with centralized high-performance computing facilities. Citrus Under Protective Screening (CUPS) exemplifies this need in digital agriculture, where citrus research facilities are instrumented with numerous sensors monitoring environmental conditions and detecting protective screening damage. CUPS demands access to computational fluid dynamics codes for modeling environmental conditions and guiding real-time interventions like water application or robotic repairs. These computing domains have contrasting properties: sensor networks provide low-performance, limited-capacity, unreliable data access, while high-performance facilities offer enormous computing power through high-latency batch processing. Private 5G networks present novel capabilities addressing this challenge by providing low latency, high throughput, and reliability necessary for near-real-time coupling of edge sensor networks with HPC simulations. This work presents xGFabric, an end-to-end system coupling sensor networks with HPC facilities through Private 5G networks. The prototype connects remote sensors via 5G network slicing to HPC systems, enabling real-time digital agriculture simulation.

Digital Agriculture↗

Application of x-ray tomography to optimization of new NOx/NH3 mixed potential sensors for vehicle on-board emissions control

Mixed potential sensors for the detection of hydrocarbons, NO{sub x}, and NH{sub 3} have been previously developed at Los Alamos National Laboratory (LANL). The LANL sensors have a unique design incorporating dense ceramic-pelletlmetal-wire electrodes and porous electrolytes. The performance of current-biased sensors using an yttria-stabilized zirconia (YSZ) electrolyte and platinum and La{sub 0.8}Sr{sub 0.2}CrO{sub 3} electrodes is reported. X-ray tomography has been applied to non-destructively examine internal structures of these sensors. NO{sub x} and hydrocarbon response of the sensors under various bias conditions is reported, and very little NO{sub x} response hysteresis was observed. The application of a 0.6 {mu}A bias to these sensors shifts the response from a hydrocarbon response to a NO{sub x} response equal for both NO and NO{sub 2} species at approximately 500 {sup o}C in air.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF A SENSOR NETWORK TEST BED FOR ISD MATERIALS AND STRUCUTRAL CONDITION MONITORING

The P Reactor at the Savannah River Site is one of the first reactor facilities in the US DOE complex that has been placed in its end state through in situ decommissioning (ISD). The ISD end state consists of a grout-filled concrete civil structure within the concrete frame of the original building. To evaluate the feasibility and utility of remote sensors to provide verification of ISD system conditions and performance characteristics, an ISD Sensor Network Test Bed has been designed and deployed at the Savannah River National Laboratory. The test bed addresses the DOE-EM Technology Need to develop a remote monitoring system to determine and verify ISD system performance. Commercial off-the-shelf sensors have been installed on concrete blocks taken from walls of the P Reactor Building. Deployment of this low-cost structural monitoring system provides hands-on experience with sensor networks. The initial sensor system consists of: (1) Groutable thermistors for temperature and moisture monitoring; (2) Strain gauges for crack growth monitoring; (3) Tiltmeters for settlement monitoring; and (4) A communication system for data collection. Preliminary baseline data and lessons learned from system design and installation and initial field testing will be utilized for future ISD sensor network development and deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Temperature Multi-Process Sensor Development for a PC-Fired Unit

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of New Optical Sensors for Measurements of Mercury Concentrations, Speciation, and Chemistry

A diode-laser-based ultraviolet absorption sensor for elemental mercury was developed and applied for measurements in a high-temperature flow reactor and in the exhaust stream of a coal-fired combustor. The final version of the sensor incorporates a 375-nm single-mode laser and a 784-nm distributed feedback (DFB) laser. The output of these lasers is sum-frequency mixed in a non-linear beta-barium borate crystal to generate a 254-nm beam. By tuning the frequency of the DFB laser, the ultraviolet beam frequency is tuned across the transition frequency of mercury at 253.7-nm. The tuning range is large enough that an off-resonant baseline was clearly visible on both sides of the Hg transition. Because of this large tuning range, the effects of broadband absorption can be effectively eliminated during data analysis. Broadband absorption is a major concern for lamp-based mercury sensor, and the sample to be monitored must be chemically treated prior to analysis to remove species such as SO{sub 2} that absorb near 253.7 nm. No pretreatment is required when our diode-laser-based sensor is used for elemental mercury measurements. Our laser sensor measurements were compared to measurements from a commercial mercury analyzer (CMA), and were generally in good agreement except that the insitu diode-laser-based sensor measurements tended to give somewhat higher concentrations than the CMA measurements, presumably due to absorption of elemental mercury in the sampling lines needed for the CMA measurements. At Texas A&M University, the homogeneous oxidation of elemental mercury was studied using a high-temperature flow reactor.

01 COAL, LIGNITE, AND PEAT↗

Open Standards for Sensor Information Processing

This document explores sensor standards, sensor data models, and computer sensor software in order to determine the specifications and data representation best suited for analyzing and monitoring computer system health using embedded sensor data. We review IEEE 1451, OGC Sensor Model Language and Transducer Model Language (TML), lm-sensors and Intelligent Platform Management Inititative (IPMI).

97 MATHEMATICS AND COMPUTING↗

A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building.

vertical garden system (VGS)↗

Design of Zeolitic Imidazolate Framework-8-Functionalized Capacitive Micromachined Ultrasound Transducer Gravimetric Sensors for Gas and Hydrocarbon Vapor Detection

A capacitive micromachined ultrasound transducer (CMUT) was engineered and functionalized with zeolitic imidazolate framework-8 (ZIF-8) dispersed in a photoresist AZ1512HS (AZ) matrix to function as a gravimetric gas sensor. The sensor response was recorded in the presence of nitrogen, argon, carbon dioxide, and methane gases as well as water, acetylene, a propane/butane mixture, n-hexane, gasoline, and diesel vapors. The photoresist matrix alone was found to have a negligible response to all the gases and vapors, except for water vapor. No visible difference in sensor response was detected when switching from nitrogen to methane gas. However, a strong shift in the sensor resonance frequency was observed when exposed to higher hydrocarbons, ranging from 1 kHz for acetylene to 7.5 kHz for gasoline. Even longer-chain hydrocarbons, specifically kerosene and more so diesel, had a significantly reduced sensor frequency shift compared with gasoline. Sensors functionalized with a thin film of AZ+ZIF-8 demonstrated higher sensitivity in their response to a hydrocarbon molecular mass than without functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Passive Wireless Temperature Sensor for Harsh Environment Applications

High temperature sensors capable of operating in harsh environments are needed in order to prevent disasters caused by structural or system functional failures due to increasing temperatures. Most existing temperature sensors do not satisfy the needs because they require either physical contact or a battery power supply for signal communication, and furthermore, neither of them can withstand high temperatures nor rotating applications. This paper presents a novel passive wireless temperature sensor, suitable for working in harsh environments for high temperature rotating component monitoring. A completely passive LC resonant telemetry scheme, relying on a frequency variation output, which has been applied successfully in pressure, humidity and chemical measurement, is integrated with a unique high-k temperature sensitive ceramic material, in order to measure the temperatures without contacts, active elements, or power supplies within the sensor. In this paper, the high temperature sensor design and performance analysis are conducted based on mechanical and electrical modeling, in order to maximize the sensing distance, the Q factor and the sensitivity. In the end, the sensor prototype is fabricated and calibrated successfully up to 235ºC, so that the concept of temperature sensing through passive wireless communication is proved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ampoule failure sensor development for semiconductor crystal growth experiments

Currently there are no devices to detect an ampoule failure in semiconductor crystal growth experiments. If an ampoule fails, it will go undetected until the containing cartridge is breached due to chemical degradation. The experiment will then be terminated resulting in a failed experiment and a loss of data. The objective of this research was to develop a reliable failure sensor that would detect a specific liquid or vapor material before the metallic cartridge is degraded and the processing furnace contaminated. The sensor is a chemical fuse made from a metal with which the semiconductor material reacts more rapidly than it does with the containing cartridge. Upon ampoule failure, the sensor is exposed to the vapor or liquid semiconductor and the chemical reaction causes a resistance change in the sensor material. The sensor shows a step change in resistance on the order of megohms when exposed to mercury zinc telluride (HgZnTe), mercury cadmium telluride (HgCdTe), or gallium arsenide (GaAs). This ampoule failure sensor is being tested for possible use on the second United States Microgravity Mission (USML-2) and is the subject of a NASA patent application.

CHEMICAL FUSE↗

High Temperature Dynamic Pressure Measurements Using Silicon Carbide Pressure Sensors

Un-cooled, MEMS-based silicon carbide (SiC) static pressure sensors were used for the first time to measure pressure perturbations at temperatures as high as 600 C during laboratory characterization, and subsequently evaluated in a combustor rig operated under various engine conditions to extract the frequencies that are associated with thermoacoustic instabilities. One SiC sensor was placed directly in the flow stream of the combustor rig while a benchmark commercial water-cooled piezoceramic dynamic pressure transducer was co-located axially but kept some distance away from the hot flow stream. In the combustor rig test, the SiC sensor detected thermoacoustic instabilities across a range of engine operating conditions, amplitude magnitude as low as 0.5 psi at 585 C, in good agreement with the benchmark piezoceramic sensor. The SiC sensor experienced low signal to noise ratio at higher temperature, primarily due to the fact that it was a static sensor with low sensitivity.

Pressure Sensors↗

State of the Industry: UAS Sensor Review

This report is a follow on from HF Designworks’ 2018 report on state of the present and state of the art sensor technologies as they related to Ground Based Detect and Avoid (GBDAA) systems for Unmanned Aircraft Systems (UAS). In this update, HF Designworks again looks to UAS test sites, manufacturers, vendors, and users to identify the latest sensor technologies covering not just GBDAA, but additional UAS sensor types; including airborne. For this latest report, the following sensor types were reviewed, as well as a few that don’t quite fit within the following categories: Electro-Optical / Infrared (EO/IR), LiDAR, RADAR, Radiofrequency (RF) scanner, Acoustic, and Other. From our interviews and research with various organizations and individuals, we found both interesting new technologies as well as improvements to many technologies first reviewed in 2018. Compared with our 2018 findings, many of the new technologies have helped produce sensors that are smaller, lighter, require less power, and have better range and resolution than those discussed in 2018. However, challenges still exist. There is no single currently available and FAA approved sensor suite that can adequately provide complete detect and avoid capabilities to meet the needs of UAS beyond visual line of sight (BVLOS) in the civilian airspace.

unmanned aircraft systems↗