Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuzzy logic controller versus classical logic controller for residential hybrid solar-wind-storage energy system

Several researches for management of diverse hybrid energy systems and many techniques have been proposed for robustness, savings and environmental purpose. In this work we aim to make a comparative study between two supervision and control techniques: fuzzy and classic logics to manage the hybrid energy system applied for typical housing fed by solar and wind power, with rack of batteries for storage. The system is assisted by the electric grid during energy drop moments. A hydrogen production device is integrated into the system to retrieve surplus energy production from renewable sources for the household purposes, intending the maximum exploitation of these sources over years. The models have been achieved and generated signals for electronic switches command of proposed both techniques are presented and discussed in this paper.

14 SOLAR ENERGY↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance based approaches in standards and regulations for smart ventilation in residential buildings: a summary review

As ventilation systems become more sophisticated (or ‘smart’) standards and regulations are changing to accommodate their use. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or IAQ advantage (or both) and less when it provides a disadvantage. This paper discusses the favorable contexts that exist in many countries, with regulations and standards proposing ‘performance-based approaches’ that both enable and reward smart ventilation. The paper gives an overview of such approaches from five countries. The common thread in all these methods is the use of metrics for the exposure to an indoor generated parameter (usually CO 2 ), and condensation risk. As the result, demand-control ventilation strategies (DCV) are widely and easily available on the market, with more than 20–30 systems available in some countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

A GaN-Based Active Power Decoupling Approach for Enhancing the Efficiency and Reliability of Residential PV Microinverters

It is a common sense that, the reliability of a system is dictated by the life-time of its weakest component. In terms of a single-phase solar photovoltaic (PV) system, including PV panel and the microinverter, the reliability of the system is confined by the electrolytic dc-link capacitor at the input of its microinverter. To enhance the reliability of the system by providing the possibility of employing film capacitors, with higher life-time rather than their electrolytic counterparts, this paper presents a novel modeling, design, and control of a PV-side active power decoupling (APD) approach. Besides, GaN FETs are employed to achieve a superior efficiency and power density of the APD. The proposed methodology is verified through a thorough design, loss modeling, and numerical analysis.

14 SOLAR ENERGY↗