Triboionization: a Novel Ionization Method by Peeling of Cohesive Substances for Mass Spectrometry

A novel ionization/sampling method termed triboionization was developed. Triboionization is an ionization method that only uses cohesive substances, such as food wrap or sticky tape, and does not require an electrode, electric power supply, heat source, light source, radiation, or gas, unlike most other conventional ambient ionization methods. In this study, the sample compound attached to adhesive tape or plastic wrap was quickly peeled off at a distance of approximately 2 cm from the atmospheric interface of a mass spectrometer. All of the five types of food wrap and 13 types of adhesive tape tested successfully ionized caffeine. Nine out of ten model compounds were detected as the corresponding molecular ions in the positive or negative mode by this ionizing contrivance using an oriented polypropylene adhesive tape. The detected molecular ions were typically protonated molecules or sodium adducts in the positive mode or deprotonated molecules in the negative mode. The elemental compositions of the observed ions were confirmed within 5 ppm by high-resolution mass spectrometry. The triboionization phenomenon was considered to depend on physical and electronic events caused by peeling off a cohesive substance. Triboionization is able to provide a compact ion source using only mechanical mechanisms. Additionally, triboionization allows sticky tape to be used as a convenient sampling device for surface analysis. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Microfluidic Cell for Studying the Precrystallization Stage Structure of Protein Solutions by Small-Angle X-Ray Scattering

A microfluidic cell has been developed for studying the structure of protein solutions using small-angle X-ray scattering. The use of prefabricated elements, which provide a small sample volume, allows one to adjust the microfluidic cell parameters to specific problems. Tests of lysozyme solutions were performed on a laboratory diffractometer AMUR-K (Institute of Crystallography, Russian Academy of Sciences), BM29 beamline (ESRF, Grenoble), and “DICSY” beamline of the Kurchatov synchrotron radiation source (National Research Centre “Kurchatov Institute”). Experiments showed that, when a 60-μm-thick quartz glass of special purity grade is applied as an X-ray-transparent window, the intrinsic level of cell background scattering in the range of measured angles is lower than that for quartz capillaries, due to which the measurement accuracy can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron Infrared Confocal Microspectroscopic Spatial Resolution or a Customized Synchrotron/focal Plane Array System Enhances Chemical Imaging of Biological Tissue or Cells

Spectroscopy and spatially resolved chemical imaging of biological materials using an infrared microscope is greatly enhanced with confocal image plane masking to 5-6 {mu} with a third generation microspectrometer and illumination with a synchrotron radiation source compared to globar illuminated and array detection or singly masked system. Steps toward this instrumental achievement are illustrated with spectra and images of biological tissue sections, including single cells, brain, aorta, and grain specimens. A recent, customized synchrotron infrared microspectrometer installation enables focal plane array detection to achieve both rapid and high definition chemical imaging. Localization of the ester carbonyl population in single modified starch granules was used to provide direct comparison of the two advanced imaging capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unexpected photoreactivation of Vibrio harveyi bacteria living in ionization environment

Bacteria undergoing environmental effects is extremely interesting for structural, mechanistic, and evolutionary implications. Luminescent bacteria that have evolved in a specific ambient have developed particular responses and their behavior can give us new suggestions on the task and production of luciferina proteins. To analyze the UV interaction under controlled laboratory conditions, we used photoluminescent bacterial strains belonging to a new species evolutionarily close to Vibrio harveyi sampled from a coastal cave with a high radon content that generates ionizing radiation. The survival of the bacterial strains was analyzed, in the light and in the dark, following a variety of genotoxic treatments including UV radiation exposure. The strains were irradiated by a germicide lamp. The results demonstrated that most of the strains exhibited a low rate of survival after the UV exposure. After irradiation by visible light following the UV exposure, all strains showed a high capability of photoreactivation when grown. This capability was quite unexpected because these bacteria were sampled from a dark ambient without UV radiation. This leads us to hypothesize that the photoreactivation in these bacteria might have been evolved to repair DNA lesions also induced by different radiation sources other than UV (e.g., x-ray) and that the luminescent bacteria might use their own light emission to carry out the photoreactivation. The high capability of photoreactivation of these bacteria was also justified by the results of deconvolution. The deconvolution was applied to the emission spectra and it was able to show evidence of different light peaks. The presence of the visible peak could control the photolysis enzyme.

60 APPLIED LIFE SCIENCES↗

Organ and effective dose rate coefficients for submersion exposure in occupational settings

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.

61 RADIATION PROTECTION AND DOSIMETRY↗

Outcomes of WPEC SG47 on "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation"

The Working Party on International Nuclear Data Evaluation Co-operation Subgroup 47 (WPECSG47) entitled "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation" was organised from 2019 and 2022 with the objectives to promote more systematic and wider use of shielding benchmark experiments in nuclear data (ND) and transport code validation and development, to provide feedback on the Shielding Integral Benchmark Archive and Database (SINBAD), and to promote its further development in coordination with the Expert Group on Physics of Reactor Systems (EGPRS). Altogether 9 meetings, the large majority (8) held remotely, were organised during the past 3 years to discuss the experience on the use of SINBAD, evaluation of new benchmarks and improvements to be contributed to the database which was severely neglected and lacking maintenance over the past ← 10+ years. Several proposals for new or updated benchmark evaluation were presented and discussed, such as FNG copper, LLNL pulsed spheres, CIAE iron sphere, KFK 1977 gamma measurements, Rez Fe sphere, ASPIS, ORNL Oxygen broomstick, TIARA and others. Complementing the database with new features was also discussed, for example providing the nuclear data sensitivity profiles more systematically would facilitate and better guide the use of data. Information on the geometry, (radiation source) and materials available in CAD format is expected to allow an easier and less error prone reference for computational model preparation and a potential input to CAD based workflows. Inputs for various transport codes and other benchmark data from participants have been shared via the NEA GitLab which could hopefully in the future evolve and form a bases for critically checked and validated benchmark data. Future development of SINBAD will be monitored by EGPRS and the newly created SINBAD Task Force.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗

Indus-2 X-ray lithography beamline for X-ray optics and material science applications

X-ray lithography is an ideal technique by which high aspect ratio and high spatial resolution micro/nano structures are fabricated using X-rays from synchrotron radiation source. The technique has been used for fabricating optics (X-ray, visible and infrared), sensors and actuators, fluidics and photonics. A beamline for X-ray lithography is operational on Indus-2. The beamline offers wide lithographic window from 1-40keV photon energy and wide beam for producing microstructures in polymers upto size ∼100mm × 100mm. X-ray exposures are possible in air, vacuum and He gas environment. The air based exposures enables the X-ray irradiation of resist for lithography and also irradiation of biological and liquid samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluate an impact of incident alpha particle and gamma ray on human blood components: A comparison study

An impact of alpha and gamma irradiation on human blood components have been evaluated and compared for healthy blood samples (male and females). Irradiation dose and time of irradiation calibrated and considered as a main comparison factors. Density of blood components measured for each in vitro irradiation before and after irradiation for males and females. Survey radiation dosimeter (Inspector Exp) and nuclear track detectors type CR-39 used to evaluate exposure dose rate and incident density of alpha particles, respectively. Experiment results verified that the irradiation of blood makes ionizing of blood components, either alpha or gamma irradiation dose, and the impacts of ionizing radiation were relativity for WBC, RBC, and PLT. Limited irradiation doses of 1-5 μSv/hr considered as a low radiation dose of alpha and gamma radiation sources ({sup 226}Ra, and {sup 137}Cs). Density of alpha particles accumulated on the blood surface was 34 (alpha particle/cm{sup 2}) for selected dose of incident alpha particle. Optimum value of irradiation dose and time of irradiation were 5 μSv/hr and 4 second for males and females. On the other hands, the values of irradiation dose and time of irradiation were 2.1 μSv/hr and 2 second for males and females for gamma irradiation. Thus, present results demonstrated that densities of RBC and WBC cells are capable of inducing reproduction in vitro for both type of irradiation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Nuclear Material Hold-up Measurement

Facilities that process special nuclear material (SNM) generally have a variety of equipment, shielding, and nearby radiation sources, which can pose challenges when performing nondestructive analysis (NDA) within the facility, as shown in Figure 1. In this figure, the left image features two individuals performing a holdup measurement of a large duct at a posting, utilizing a detector probe attached to a yardstick to reduce some aspect of the measurement uncertainty. Note that the distance to the holdup within the pipe from the posting cannot be accounted for. The right image similarly features several individuals guiding a holdup measurement of a ducting pipe several meters overhead, by attaching a detector probe to a long handle and lining that up with a posting on the outside of the pipe. SNM processing begets SNM holdup, and this difficulty with accurate NDA can result in unaccounted accumulation of SNM holdup within a process or area. Normal SNM processing operations can accumulate holdup within filters, pumps, pipes, ducts, other equipment, and facility support systems, as demonstrated by Figure 2. It is important for deactivation and decommissioning (D&D) gloveboxes and their ancillary equipment, material accountability, criticality safety, facility operations, waste management, radiation safety, and security to accurately characterize the location, composition, and quantity of this holdup to minimize these associated risks and potential diversion pathways. Current NDA techniques for assay of holdup are expensive, time consuming, and have high uncertainty.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural investigations of interfaces in Fe{sub 90}Sc{sub 10} nanoglasses using high-energy x-ray diffraction

High-resolution diffraction experiments of Fe{sub 90}Sc{sub 10} nanoglasses and rapidly quenched metallic glasses as reference materials have been performed using high-energy x-rays with a wavelength of 0.21 Angst from a synchrotron radiation source. Nanoglasses are amorphous alloys with a significant fraction of interfaces on the nanometer scale. The short- and intermediate-range orders of a nanoglass are different from the well known amorphous materials produced by rapid quenching from the melt. These structural modifications have significant influence on the physical properties. In this paper, the short- and intermediate-range orders of the nanoglass Fe{sub 90}Sc{sub 10} and the reference metallic glass Fe{sub 90}Sc{sub 10} alloy prepared by rapid quenching are discussed.

36 MATERIALS SCIENCE↗

Simultaneous measurements of X-ray reflectivity and grazing incidence fluorescence at BL-16 beamline of Indus-2

A new multipurpose x-ray reflectometer station has been developed and augmented at the microfocus beamline (BL-16) of Indus-2 synchrotron radiation source to facilitate synchronous measurements of specular x-ray reflectivity and grazing incidence x-ray fluorescence emission from thin layered structures. The design and various salient features of the x-ray reflectometer are discussed. The performance of the reflectometer has been evaluated by analyzing several thin layered structures having different surface interface properties. The results reveal in-depth information for precise determination of surface and interface properties of thin layered materials demonstrating the immense potential of the combined measurements of x-ray reflectivity and grazing incidence fluorescence on a single reflectometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography

Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined dose profiles are in agreement with reference measurements. An inherent drawback of the scintillator is the nonlinear light output for high stopping-power radiation due to the quenching effect. It impacts the depth dose curves measured with the dosimeter. For single Bragg peak distributions this leads to a peak to plateau ratio of 2.8 instead of 4.5 for the reference ionization chamber measurement. Furthermore, the transmission of the clinical bremsstrahlung beams through the scintillator leads to the saturation of one camera, making dose reconstructions in that case presently not feasible.Conclusions: It is shown that distributions of scintillation light generated by proton or electron beams can be reconstructed by the dosimetry system within minutes. The quenching apparent for proton irradiation, and the yet not precisely determined position dependency of the imaging scale, require further investigation and corrections. Upgrading the prototype with larger or inorganic scintillators would increase the detectable proton and electron energy range. The presented results show that the determination of 3D dose distributions using scintillator blocks and optical tomography is a promising dosimetry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bipolar charging of dust particles under ultraviolet radiation

The photoemission charging of dust particles under ultraviolet radiation from a xenon lamp has been investigated. The velocities of yttrium dust particles with a work function of 3.3 eV and their charges have been determined experimentally; the latter are about 400-500 and about 100 elementary charges per micron of radius for the positively and negatively charged fractions, respectively. The dust particle charging and the dust cloud evolution in a photoemission cell after exposure to an ultraviolet radiation source under the applied voltage have been simulated numerically. The photoemission charging of dust particles has been calculated on the basis of nonlocal and local charging models. Only unipolar particle charging is shown to take place in a system of polydisperse dust particles with the same photoemission efficiency. It has been established that bipolar charging is possible in the case of monodisperse particles with different quantum efficiencies. Polydispersity in this case facilitates the appearance of oppositely charged particles in a photoemission plasma.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The LLNL rabbit: determination of trace element levels in polyethylene

Rabbit facilities are systems that pneumatically transport a sample carrier (known as a rabbit) to and from a radiation source. However, trace impurities in the polyethylene (PE) rabbit may interfere with measurements of short-lived isotopes. Activated impurities with short half-lives as 28 Al interfere with the fission product γ-ray, therefore the rabbit cannot be measured immediately. Neutron activation analysis was performed on various PE samples obtained from different manufacturers and the highest quality PE was used to fabricate a high-purity PE rabbit. Here, the impurities identified in the PE study were 27 Al, 48 Ca, 37 Cl, 50 Cr, 65 Cu, 127 I, 26 Mg, 55 Mn, and 30 Si.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Néel walls between tailored parallel-stripe domains in IrMn/CoFe exchange bias layers

Tailored parallel-stripe magnetic domains with antiparallel magnetizations in adjacent domains along the long stripe axis have been fabricated in an IrMn/CoFe Exchange Bias thin film system by 10 keV He{sup +}-ion bombardment induced magnetic patterning. Domain walls between these domains are of Néel type and asymmetric as they separate domains of different anisotropies. X-ray magnetic circular dichroism asymmetry images were obtained by x-ray photoelectron emission microscopy at the Co/Fe L{sub 3} edges at the synchrotron radiation source BESSY II. They revealed Néel-wall tail widths of 1 μm in agreement with the results of a model that was modified in order to describe such walls. Similarly obtained domain core widths show a discrepancy to values estimated from the model, but could be explained by experimental broadening. The rotation senses in adjacent walls were determined, yielding unwinding domain walls with non-interacting walls in this layer system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation of titanium carbonitride film by laser treatment: Structural and transport properties

In-plane and Out-of-plane Grazing incidence X-ray diffraction is used to characterize the preferred orientation present in the titanium carbonitride films using ADXRD beamline at INDUS 2 synchrotron radiation source. GIXRD shows the formation of mixture of FCCTiC{sub x}N{sub (1-x)} films for different values of x along with the solid solution. From the in-plane and out-of-plane XRD measurements, we have observed that a specific texture along the c-axis of Ti has been formed during the laser treatment process. Due to the diffusion of C and N into Ti, the resistance of the specimen has been decreases with respect to the resistance of pure Ti sheet. The formed phases are stable and there is no structural relaxation has been observed during annealing process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗