Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Fractal analysis of collision cascades in pulsed-ion-beam-irradiated solids [Collision cascade densities in ion pulsed ion irradiated solids { a fractal approach]

The buildup of radiation damage in ion-irradiated crystals often depends on the spatial distribution of atomic displacements within collision cascades. Although collision cascades have previously been described as fractals, the correlation of their fractal parameters with experimental observations of radiation damage buildup remains elusive. Here, we use a pulsed-ion-beam method to study defect interaction dynamics in 3C-SiC irradiated at 100 °C with ions of different masses. These data, together with results of previous studies of SiC and Si, are analyzed with a model of radiation damage formation which accounts for the fractal nature of collision cascades. Our emphasis is on the extraction of the effective defect diffusion length from pulsed beam measurements. Results show that, for both Si and SiC, collision cascades are mass fractals with fractal dimensions in the range of ~1–2, depending on ion mass, energy, and the depth from the sample surface. Within our fractal model, the effective defect diffusion length is ~10 nm for SiC and ~20 nm for Si, and it decreases with increasing cascade density. These results demonstrate a general method by which the fractal nature of collision cascades can be used to explain experimental observations and predict material’s response to radiation.

36 MATERIALS SCIENCE↗

Efimov Trimer Formation via Ultracold Four-Body Recombination

We discuss the collisional formation of Efimov trimers via ultracold four-body recombination. In particular, we consider the reaction A+A+A+B{yields}A{sub 3}+B with A and B ultracold atoms. We obtain expressions for the four-body recombination rate up to an overall constant and show that it reflects the three-body Efimov physics either as a function of collision energy or as a function of the two-body s-wave scattering length between A atoms. In addition, we briefly discuss issues important for experimentally observing this interesting and unexplored process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

Microstructure of the multiple-filamentation zone formed by femtosecond laser radiation in a solid dielectric

The regularities of multiple filamentation of gigawatt femtosecond laser pulses in a solid dielectric (optical glass) have been considered. The fine spatial structure of the plasma region that is formed under glass photoionisation and accompanies the formation of light filaments is analysed experimentally and by means of numerical simulation. The dependence of the number, position, and extension of individual 'generations' of plasma channels on the laser pulse energy has been investigated for the first time. It is found that the distribution of the number of plasma channels over the length of a dielectric sample has a maximum, the position of which correlates well with the position of the nonlinear focus of the light beam as a whole; at the same time, the average channel length decreases with increasing pulse power, whereas the number of successive channel 'generations', on the contrary, increases. (interaction of laser radiation with matter. laser plasma)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomaly in Dependence of Radiation-induced Vacancy Accumulation on Grain Size

According to conventional steady-state rate theory predictions of displacement damage evolution in irradiated materials, the accumulation of vacancies decreases as grain size decreases. Using atomistic simulations, the authors report a transient anomaly in the dependence of radiation produced vacancy accumulation on grain size. Contrary to the conventional wisdom, the accumulation of vacancies can be higher in smaller grains than in larger grains during a transient stage. The anomaly is a result of competition between two atomic-level processes: grain boundary absorption and bulk recombination of point defects, each of which has characteristic length and time scales. A simple metal copper is used as the prototype of face-centered cubic material and electron radiation is the source of non-cascade defect production, both choices aiming at clarity for identifying physical mechanisms.

36 MATERIALS SCIENCE↗

Research on optimization of cooling structure of LED element (The 2nd report)

This report shows a design guideline on the parts dimension of LED light bulb for heat transfer. LED light bulb is popular owing to the high efficiency and long life. However, LED element is a point heat source. Therefore, LED light bulb has some problems about heat transfer when it is used for lighting. It sometimes causes deterioration by the raise of local temperature, resulting in lowering of efficiency and shorter life. Thus the thermal analysis focused on the number of element, all parts thickness, length, and radiant heat was studied, as systematic report on the points has not been found. In this report, heat radiation was taken into account in the thermal analysis in addition to natural heat convection. Furthermore the temperature of a heat sink model for LED light bulb was measured with thermocouples and thermo-viewer to verify the calculation. The emissivity of aluminum used for the calculation was 0.4. As the result of analysis, it was found that the maximum temperature was mainly influenced by ring length, ring diameter and disk thickness as a design guideline. Concretely, longer length, larger diameter and thicker disk gave lower temperature of LED element. The temperatures of the best and worst model were around 70 °C and 120 °C respectively in the above condition. The temperatures calculated were consistent with those in experiment.

42 ENGINEERING↗

Oscillator strengths and radiative rates for transitions in neutral sulfur

We present accurate oscillator strengths and radiative rates for 2173 E1 transitions among the 120 levels belonging to 3s{sup 2}3p{sup 4}, 3s3p{sup 5}, and 3s{sup 2}3p{sup 3}({sup 4}S{sup o},{sup 2}D{sup o},{sup 2}P{sup o})nl configurations where nl=4s,5s,6s,4p,5p,6p,3d,4d,4f,5f. A configuration interaction approach is employed through the standard CIV3 program. The 114 LS states included in the present calculation generate 250 fine-structure levels belonging to the above configurations below 100,000 cm{sup -1}. However, results of only 120 fine-structure levels are presented due to the absence of experimental energy values for the remaining levels. Tabulations of oscillator strengths and radiative rates, and their comparison with other calculations, are presented in the first two tables. In a separate table the oscillator strengths and transition probabilities, in length and velocity gauges, are presented for 2173 E1 transitions, and are arranged in ascending order of wavelength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Length-scale Effects in Cascade Damage Production in Iron

Molecular dynamics simulations provide an atomistic description of the processes that control primary radiation damage formation in atomic displacement cascades. An extensive database of simulations describing cascade damage production in single crystal iron has been compiled using a modified version of the interatomic potential developed by Finnis and Sinclair. This same potential has been used to investigate primary damage formation in nanocrystalline iron in order to have a direct comparison with the single crystal results. A statistically significant number of simulations were carried out at cascade energies of 10 keV and 20 keV and temperatures of 100 and 600K to make this comparison. The results demonstrate a significant influence of nearby grain boundaries as a sink for mobile defects during the cascade cooling phase. This alters the residual primary damage that survives the cascade event. Compared to single crystal, substantially fewer interstitials survive in the nanograined iron, while the number of surviving vacancies is similar or slightly greater than the single crystal result. The fraction of the surviving interstitials contained in clusters is also reduced. The asymmetry in the survival of the two types of point defects is likely to alter damage accumulation at longer times.

36 MATERIALS SCIENCE↗

Structural analysis of Li-intercalated hexagonal boron nitride

A structural investigation of Li-intercalated hexagonal boron nitride (Li-h-BNIC) was performed by synchrotron powder X-ray diffraction analysis and transmission electron microscopy. The host BN framework of Li-h-BNIC was expanded by Li-intercalation. The intralayer B-N bond length was increased by 2.48(1)% and the interlayer distance was expanded by 12.86(1)%. No superlattice structure of intercalated Li was observed. - Graphical abstract: XRD pattern fitting of the sample and schematic view of host h-BN lattice. Highlights: Black-Right-Pointing-Pointer Li-intercalated h-BN was investigated by synchrotron radiation powder XRD. Black-Right-Pointing-Pointer Lattice parameter of host h-BN lattice was increased by intercalation. Black-Right-Pointing-Pointer Increase ratio of B-N bond length was considerably larger than those of Li GICs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fuel Fabrication Specification Impact Analysis for NBSR LEU Conversion

As part of a national initiative to enhance nuclear security and reduce proliferation risks, significant efforts have been undertaken by the National Nuclear Security Administration Material Management and Minimization Office of Reactor Conversion Program to convert U.S. high performance research reactors (USHPRRs) from the use of highly enriched uranium (HEU) to low-enriched uranium (LEU), including the National Bureau of Standards Reactor (NBSR). The current plan is to procure LEU fuel assemblies from commercial fabricators according to fuel specifications tailored for each USHPRR. The analysis conducted at Brookhaven National Laboratory was part of an effort to identify the sources of uncertainty in the fuel specifications that may impact the performance of the NBSR core after its conversion and, in particular, to assess the range of acceptable tolerance limits from the perspective of core safety and reactor performance. Using the stochastic neutronics code MCNP 6.2, the variations in important NBSR neutronics characteristics were analyzed as a function of the specification parameters independently and in combination. The important NBSR specification parameters analyzed were the fuel isotopic composition, the amount of impurity content in cladding, the fuel plate thickness, and the fuel element 235U mass loading. The range of variation of each specification parameter was based on the technical specification limit or available as-fabricated assay data and uncertainties. The NBSR neutronics characteristics selected for analysis were the reactor reactivity characteristics at equilibrium and the equilibrium fuel cycle length. Results show that with variations in the fabrication parameters of the as-fabricated U-10Mo fuel within the specification limitations, the excess reactivity of the NBSR LEU core remains well below the 15% Δk/k technical specification limit, and the shutdown margin is always significantly greater than the required 0.68% Δk/k. This ensures that the NBSR can be operated safely and reliably shut down for all analyzed cases within the specified fabrication limits after the LEU conversion. In the prototypic case, the fuel cycle length was 1.5 days longer than the targeted 38.5 days. In a credible worst-case scenario, where all low-reactivity parameters were combined, the fuel cycle length was reduced to 35.5 days, which is still considered manageable for reactor operations. Variations in cycle length are primarily driven by changes in 235U loading, with other parameters having secondary effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-E-BRE-06: High-Dose Microbeam Radiation Induces Different Responses in Tumor Microenvironment Compared to Conventional Seamless Radiation in Window Chamber Tumor Models

Purpose: Microbeam radiation therapy and GRID therapy are different forms of Spatially-Fractioned Radiation Therapy (SFRT) that is fundamentally different from the conventional seamless and temporally fractionated radiation therapy. SFRT is characterized by a ultra-high dose (10s –100s Gy) dose single treatment with drastic inhomogeneity pattern of given spatial frequencies. Preclinical and limited clinical studies have shown that the SFRT treatments may offer significant improvements in reducing treatment toxicity, especially for those patients who have not benefited from the state-of-the-art radiation therapy approaches. This preliminary study aims to elucidate the underlying working mechanisms of SFRT, which currently remains poorly understood. Methods: A genetically engineered 4T1 murine mammary carcinoma cell line and nude mice skin fold window chamber were used. A nanotechnology-based 160kV x-ray irradiator delivered 50Gy (entrance dose) single treatments of microbeam or seamless radiation. Animals were in 3 groups: mock, seamless radiation, and 300μm microbeam radiation. The windows were imaged using a hyperspectral system to capture total hemoglobin/saturation, GFP fluorescence emission, RFP fluorescence emission, and vessel density at 9 time points up to 7 days post radiation. Results: We found unique physiologic changes in different tumor/normal tissue regions and differential effects between seamless and microbeam treatments. They include 1) compared to microbeam and mock radiation seamless radiation damaged more microvasculature in tumor-surrounding normal tissue, 2) a pronounced angiogenic effect was observed with vascular proliferation in the microbeam irradiated portion of the tumor days post treatment (no such effect observed in seamless and mock groups), and 3) a notable change in tumor vascular orientation was observed where vessels initially oriented parallel to the beam length were replaced by vessels running perpendicular to the irradiation portion of the tumor. Conclusion: Our preliminary study indicated that microbeam radiation modified tumor microenvironment in ways significantly different than of the conventional seamless radiation.

60 APPLIED LIFE SCIENCES↗

Calculation of Coherent Synchrotron Radiation Impedance Using the Mode Expansion Method

We study an impedance due to coherent synchrotron radiation (CSR) generated by a short bunch of charged particles passing through a dipole magnet of finite length in a vacuum chamber of a given cross section. In our method we decompose the electromagnetic field of the beam over the eigenmodes of the toroidal chamber and derive a system of equations for the expansion coefficients in the series. The general method is further specialized for a toroidal vacuum chamber of a rectangular cross section where the eigenmodes can be computed analytically. We also develop a computer code that calculates the CSR impedance for a toroid of rectangular cross section. Numerical results obtained with the code are presented in the paper.

43 PARTICLE ACCELERATORS↗

On the reproducibility of protein crystal structures: five atomic resolution structures of trypsin

Details of five very high-resolution accurate structures of bovine trypsin are compared in the context of the reproducibility of models obtained from crystals grown under identical conditions. Structural studies of proteins usually rely on a model obtained from one crystal. By investigating the details of this model, crystallographers seek to obtain insight into the function of the macromolecule. It is therefore important to know which details of a protein structure are reproducible or to what extent they might differ. To address this question, the high-resolution structures of five crystals of bovine trypsin obtained under analogous conditions were compared. Global parameters and structural details were investigated. All of the models were of similar quality and the pairwise merged intensities had large correlation coefficients. The C{sup α} and backbone atoms of the structures superposed very well. The occupancy of ligands in regions of low thermal motion was reproducible, whereas solvent molecules containing heavier atoms (such as sulfur) or those located on the surface could differ significantly. The coordination lengths of the calcium ion were conserved. A large proportion of the multiple conformations refined to similar occupancies and the residues adopted similar orientations. More than three quarters of the water-molecule sites were conserved within 0.5 Å and more than one third were conserved within 0.1 Å. An investigation of the protonation states of histidine residues and carboxylate moieties was consistent for all of the models. Radiation-damage effects to disulfide bridges were observed for the same residues and to similar extents. Main-chain bond lengths and angles averaged to similar values and were in agreement with the Engh and Huber targets. Other features, such as peptide flips and the double conformation of the inhibitor molecule, were also reproducible in all of the trypsin structures. Therefore, many details are similar in models obtained from different crystals. However, several features of residues or ligands located in flexible parts of the macromolecule may vary significantly, such as side-chain orientations and the occupancies of certain fragments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A compact high-resolution X-ray ion mobility spectrometer

For the ionization of gaseous samples, most ion mobility spectrometers employ radioactive ionization sources, e.g., containing {sup 63}Ni or {sup 3}H. Besides legal restrictions, radioactive materials have the disadvantage of a constant radiation with predetermined intensity. In this work, we replaced the {sup 3}H source of our previously described high-resolution ion mobility spectrometer with 75 mm drift tube length with a commercially available X-ray source. It is shown that the current configuration maintains the resolving power of R = 100 which was reported for the original setup containing a {sup 3}H source. The main advantage of an X-ray source is that the intensity of the radiation can be adjusted by varying its operating parameters, i.e., filament current and acceleration voltage. At the expense of reduced resolving power, the sensitivity of the setup can be increased by increasing the activity of the source. Therefore, the performance of the setup can be adjusted to the specific requirements of any application. To investigate the relation between operating parameters of the X-Ray source and the performance of the ion mobility spectrometer, parametric studies of filament current and acceleration voltage are performed and the influence on resolving power, peak height, and noise is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slowing down of spin glass correlation length growth: Simulations meet experiments

The growth of the spin glass correlation length has been measured as a function of the waiting time $t_ w$ on a single crystal of CuMn (6 at. %), reaching values $ξ ~ 150$ nm, larger than any other glassy correlation length measured to date. We find an aging rate $d ln $t_w/d ln $ξ$ larger than found in previous measurements, which evinces a dynamic slowing down as $ξ$ grows. Our measured aging rate is compared with simulation results by the Janus Collaboration. After critical effects are taken into account, we find excellent agreement with the Janus data.

36 MATERIALS SCIENCE↗

FLUCTUATIONS IN THE IONIZING BACKGROUND DURING AND AFTER HELIUM REIONIZATION

The radiation background above the ionization edge of He II varies strongly during and after helium reionization, because the attenuation length of such photons is relatively short ({approx}<40Mpc) and because the ionizing sources (quasars) are rare. Here we construct analytic and Monte Carlo models to examine these fluctuations, including, for the first time, those during the reionization era itself. In agreement with detailed numerical simulations, our analytic model for the post-reionization universe predicts order-of-magnitude fluctuations in the He II ionization rate GAMMA. Observations of the hardness ratio He II/H I show somewhat larger fluctuations, which may be due to more complicated radiative transfer effects. During reionization, the fluctuations are even stronger. In contrast to hydrogen reionization, our model predicts that regions with strong He II Lyalpha forest transmission should be reasonably common even during the beginning stages of reionization, because of strong illumination from nearby bright quasars. Partly because of this, the mean ionizing background does not evolve strongly during and after helium reionization; it is roughly proportional to the filling fraction of He III regions. On the other hand, regions full of He II and also 'fossil'-ionized regions that contain no (or few) active sources appear as strong intergalactic absorbers. Their presence exaggerates the evolution of the hardness ratio, making it evolve more strongly than naively expected during the reionization era.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of the cherenkov telescope array to the detection of intergalactic magnetic fields

Very high energy (VHE; energy E ≳ 100 GeV) γ-rays originating from extragalactic sources undergo pair production with low-energy photons of background radiation fields. These pairs can inverse-Compton-scatter background photons, initiating an electromagnetic cascade. The spatial and temporal structure of this secondary γ-ray signal is altered as the e{sup +}e{sup −} pairs are deflected in an intergalactic magnetic field (IGMF). We investigate how VHE observations with the future Cherenkov Telescope Array, with its high angular resolution and broad energy range, can potentially probe the IGMF. We identify promising sources and simulate γ-ray spectra over a wide range of values of the IGMF strength and coherence length using the publicly available ELMAG Monte Carlo code. Combining simulated observations in a joint likelihood approach, we find that current limits on the IGMF can be significantly improved. The projected sensitivity depends strongly on the time a source has been γ-ray active and on the emitted maximum γ-ray energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Compaction in optical fibres and fibre Bragg gratings under nuclear reactor high neutron and gamma fluence

In the framework of the development by CEA and SCK.CEN of a Fabry Perot Sensor (FPS) able to measure dimensional changes in Material Testing Reactor (MTR), the first goal of the SAKE 1 (Smirnof extention - Additional Key-tests on Elongation of glass fibres) irradiation was to measure the linear compaction of single mode fibres under high fast neutron fluence. Indeed, the compaction of the fibre which forms one side of the Fabry Perot cavity, may in particular cause a noticeable measurement error. An accurate quantification of this effect is then required to predict the radiation-induced drift and optimize the sensor design. To achieve this, an innovative approach was used. Approximately seventy uncoated fibre tips (length: 30 to 50 mm) have been prepared from several different fibre samples and were installed in the SCK.CEN BR2 reactor (Mol Belgium). After 22 days of irradiation a total fast (E > 1 MeV) fluence of 3 to 5x10{sup 19} n{sub fast}/cm{sup 2}, depending on the sample location, was accumulated. The temperature during irradiation was 291 deg. C, which is not far from the condition of the intended FPS use. A precise measurement of each fibre tip length was made before the irradiation and compared to the post irradiation measurement highlighting a decrease of the fibres' length corresponding to about 0.25% of linear compaction. The amplitude of the changes is independent of the capsule, which could mean that the compaction effect saturates even at the lowest considered fluence. In the prospect of performing distributed temperature measurement in MTR, several fibre Bragg gratings written using a femtosecond laser have been also irradiated. All the gratings were written in radiation hardened fibres, and underwent an additional treatment with a procedure enhancing their resistance to ionizing radiations. A special mounting made it possible to test the reflection and the transmission of the gratings on fibre samples cut down to 30 to 50 mm. The comparison of measurements made before and after the irradiation, at the same temperature, allowed us to measure the loss in reflectivity as well as the Bragg wavelength drift. The results are quite promising for some of the investigated gratings. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗