Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A Practical Look at Assumptions and Constraints for Steady State Modeling of sCO2 Brayton Power Cycles

Modeling supercritical CO2 (sCO2) power cycles requires specification of system constraints and component performance metrics such as pressure losses and temperature limitations.? Differing assumptions made by the model designers may lead to significantly different results which are due to the assumptions and not to the underlying thermodynamics which characterize the cycle performance. As leaders in setting standards for techno-economic analyses, NETL and EPRI have collaborated to propose a set of practical modeling assumptions that can serve as a common baseline for both indirect and direct sCO2 power plant studies, allowing for more meaningful cycle comparisons. These include specifications for turbine inlet temperature (high temperature and pressure limitations), compressor inlet temperature and pressure (cooling limitations), heat exchanger effectiveness/temperature differentials and pressure drop, and full- and part-load turbine and compressor efficiencies.

Thimsen, David↗

Practical Challenges and Failure Modes During Fabrication of Haynes 230 Micro-Pin Solar Receivers for High Temperature Supercritical Carbon Dioxide Operation

Printed circuit heat exchangers (PCHX) fabricated from high nickel alloys have shown promise as primary heat exchangers, recuperators, and solar receivers for high temperature and pressure supercritical carbon dioxide power cycles. There are numerous challenges in fabricating these devices including forming channel features, joining via diffusion or transient liquid phase bonding, and brazing/welding of headers. Commercial entities are understandably hesitant to share propriety best practices, and both commercial and non-commercial entities working on these components tend not to publically share failures and mistakes. However, sharing of this information could prevent similar costly errors and further the understanding of the coupled manufacturing, materials and mechanics issues in creating these components. Thus, in this paper, we document the challenges, failures, and mitigation methods uncovered in fabrication of prototype micro-pin based solar thermal receivers constructed of Haynes 230 and fabricated through a combination of photochemical machining (PCM), wire electrical discharge machining (EDM), transient liquid phase (TLP) bonding, vacuum brazing, and gas tungsten arc welding (GTAW). The receiver is designed to absorb concentrated solar fluxes greater than 140 W cm-2, while heating supercritical carbon dioxide from 550 °C to 720 °C at a pressure of 20 MPa to 25 MPa. The prototype receiver consists of a thin (~ 450 µm), Haynes 230 coversheet bonded to a 15 cm × 15 cm Haynes 230 micro-pin plate. The pieces are joined using a TLP bonding process with a nickel-phosphorus interlayer. Prior to bonding, micro-pins with height ~150 µm and diameter 300 µm are fabricated using PCM in the plate, and through slot features are made using wire EDM. Finally, flow headers are joined to the microchannel plate through a combination of vacuum brazing and GTAW. During hydrostatic proof testing, the prototype device failed when the coversheet delaminated from the pin array at a pressure of 290 bar. A failure analysis including scanning electron microscopy (SEM) to view failure sites and energy-dispersive X-ray spectroscopy (EDS) to evaluate elemental analysis of the failed areas was conducted. The failure modes can be broadly categorized as (1) failures potentially relating to reliquification of the transient liquid phase bonds between the micro-pins plate and coversheet during post-processing, (2) failures related to manufacturing defects, and (3) failures attributed to design.

14 SOLAR ENERGY↗

EFCOG Best Practice #65 Engineering Calculations

The purpose of this paper is to present guidance for developing engineering calculations to assure that such technical documents meet the quality requirements of 10 CFR 830 and DOE O 414.1C. More specifically, this paper presents guidance related to the following general topics: Development; Design Input/Assumptions; Documentation/Content; Format; Rigor; Review/Verification; Approval; Revisions. Guidance for this paper was also taken from ASME NQA-1, Quality Assurance Requirements for Nuclear Facility Applications and its predecessor ANSI N45.2.11, Quality Assurance Requirements for the Design of Nuclear Power Plants. These standards clearly point to what can be described as a graded approach. This guidance presented in this paper is intended to apply to safety related structures, systems and components (SSCs) whose reliable performance prevents or mitigates accidents that could cause undue risk to the health and safety of the public. Extension beyond this scope to non-safety related SSCs represents good engineering practice.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Brilliant Execution of Smart Labs: Employing Best Practices to Improve Safety and Reduce Energy for Sustainable Labs: Preprint

Laboratory buildings often dominate the energy use on research campuses, consuming three to four times the energy of a typical office building. In most cases, these facilities are defined as “mission critical,” with excessive energy use as simply an unfortunate truth that cannot be avoided without compromising safety. However, case studies indicate cost savings opportunities of up to 40% in laboratories (compared to standard practices) by employing energy efficient design strategies that also improve the safety of lab spaces (Better Buildings 2018). To help stakeholders implement improvement measures, the Smart Labs Toolkit describes a proven approach to optimizing performance of laboratories and critical control environments in new or existing facilities. The Toolkit outlines distinct phases for building a successful Smart Labs program that include: Plan, Assess, Optimize, and Manage. Each phase has specific tasks, training videos, and resources to educate users, support the efforts of key stakeholders, and maximize benefits for the organization in implementing high-performance labs. The Toolkit also includes case studies from the 17 Better Buildings Smart Labs Accelerator partners, sharing lessons learned and supporting the Smart Labs approach to safe, efficient world class science. This paper reviews the technology choices for implementing Smart Labs ventilation strategies, controls, and other efficiency measures. Better Building Smart Lab Accelerator partners provide case study examples of safety and energy-savings results of using Smart Labs approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction: A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

20 FOSSIL-FUELED POWER PLANTS↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

Best Practices for Selecting an ESCO: ESPC Accelerator

This document details steps and best practices for selecting an energy services company (ESCO), including how to conduct a request for proposals, to execute energy savings performance contracting (ESPC) projects.

EPSC, Energy Savings Performance Contracting, ESCO↗

Measure Utility, Gain Trust: Practical Advice for XAI Researchers

Research into explanation of machine learning models, i.e. explainable AI (XAI), has seen a sympathetic exponential growth alongside deep artificial neural networks throughout the past decade. For historical reasons explanation and trust have been intertwined. However this focus on trust is too narrow, and has led the research community astray from tried and true empirical methods that lead to more defensible scientific knowledge about people and explanations. To address this, we contribute a practical path forward for researchers in the XAI field. We recommend researchers focus on the utility and impact of their explanations instead of trust. We outline five broad use cases where explanations are useful and, for each, we describe pseudo-experiments that rely on objective empirical measurements and falsifiable hypotheses. We believe that this experimental rigor is necessary to contribute to scientific knowledge in the field of XAI.

Davis, Brittany F.↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

2021 ROMANIA TRANSPORT SECURITY TABLE-TOP EXERCISE (TTX) – LESSONS LEARNED AND GOOD PRACTICES

During the period of 15-18 March 2021, the IAEA conducted a national workshop addressing the security of radioactive material in transport. The workshop was jointly hosted by the Romanian regulatory authority and the General Inspectorate of Romanian Gendarmerie. The workshop assisted Romania in improving its capability to evaluate the ability of response forces to counter a malicious act against radioactive material in transport. The event consisted of briefings, exercises, a demonstration of transport security equipment, and a transport security table-top exercise (TTX). The workshop was conducted in a virtual-hybrid format in such a way as to meet the COVID-19 related requirements in compliance with Romania’s guidelines. This paper provides an overview of the workshop’s activities, lessons-learned, and good practices related to the transport security TTX exercises.

Maican, Catalin↗

IEEE P2988: Recommended Practice of Use and Functions of Virtual Synchronous Machines

Power systems are going through a paradigm shift from centralized generation to distributed generation. This brings unprecedented challenges to power systems stability, reliability, and security. Operating power electronic converters as Virtual Synchronous Machines (VSMs) can bring backward compatibility to power systems, unify and harmonize the integration and interaction of future power systems players, and improve power system stability, reliability, and security. This is vital for the large-scale adoption of distributed energy resources, the advancement of sustainability, and the development of a low-carbon economy. This IEEE 2988 Recommended Practice will define the fundamental principles, mandatory functions, and optional functions of a VSM, i.e., a power electronic converter that is operated to behave like conventional synchronous machines. It will not describe or specify power semiconductor devices, hardware topologies, or micro-controllers that are used to build a VSM. This talk will discuss the activities and development plan for IEEE 2988 with the aim to engaging broad stakeholders and widening participation.

Zhong, Qing-Chang↗

Best Practices for Enhancing Performance Contracts with Monitoring-Based Commissioning

Fact sheet highlights best practices for incorporating monitoring-based commissioning (MBCx), a type of energy management information system (EMIS), in performance contracts. It draws from the Federal Energy Management Program (FEMP) report, Enhancing Performance Contracts Using Monitoring-based Commissioning. MBCx is commercially available, yet is underutilized in performance contracts. MBCx can result in significant benefits for both a federal facility and the performance contractor.

EMIS↗

Evaluating the Practicability of Multiphase CFD for BWR Fuel Assembly Analysis

Multiphase computational fluid dynamics (M-CFD) models of a boiling water reactor (BWR) fuel assembly have been generated in the commercial CFD code, STAR-CCM+ Ver.11.04.010-R8. The Eulerian multiphase approach was employed, in combination with a baseline ‘Zero Closure model’ for two-phase flow boiling, applicable to high void fraction regimes. The capability and practicability of MCFD for BWR fuel assembly were evaluated against the international OECD/NRC BWR Full-size Finemesh Bundle Test (BFBT) benchmark data. The benchmark selected, BFBT-4101-61, is a steady-state full power case, with high void fraction conditions. Geometrical modeling and mesh construction of BWR assemblies introduce challenges in generating high quality computational meshes, while retaining a low cell count to allow acceptable runtimes. In order to evaluate the scalability of the CFD code, parallel CFD simulations were carried out with the High Performance Computing (HPC) system of the Idaho National Laboratory. M-CFD results display good agreement with the experimental data for both local void fraction distribution and exit quality. The parallel speedup factor is linearly proportional to the number of processors up to 500 cores, and retains over 92% efficiency with 1000 cores. The execution time of the simulation decreased exponentially with increasing number of processors while the cost of the simulation increased linearly. The proposed baseline closure, in combination with the parallel performance of the STAR-CCM+ code demonstrated promising capabilities for analyzing BWR fuel assemblies.

97 MATHEMATICS AND COMPUTING↗