Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Position resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Observation of coupled vortex gyrations by 70-ps-time- and 20-nm-space-resolved full-field magnetic transmission soft x-ray microscopy

We employed time- and space-resolved full-field magnetic transmission soft x-ray microscopy to observe vortex-core gyrations in a pair of dipolar-coupled vortex-state Permalloy (Ni{sub 80}Fe{sub 20}) disks. The 70 ps temporal and 20 nm spatial resolution of the microscope enabled us to simultaneously measure vortex gyrations in both disks and to resolve the phases and amplitudes of both vortex-core positions. We observed their correlation for a specific vortex-state configuration. This work provides a robust and direct method of studying vortex gyrations in dipolar-coupled vortex oscillators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helix Dipole Movement and Conformational Variability Contribute to Allosteric GDP Release in G[alpha] Subunits

Heterotrimeric G proteins (Galphabetagamma) transmit signals from activated G protein-coupled receptors (GPCRs) to downstream effectors through a guanine nucleotide signaling cycle. Numerous studies indicate that the carboxy-terminal alpha5 helix of Galpha subunits participates in Galpha-receptor binding, and previous EPR studies suggest this receptor-mediated interaction induces a rotation and translation of the alpha5 helix of the Galpha subunit [Oldham, W. M., et al. (2006) Nat. Struct. Mol. Biol. 13, 772-777]. On the basis of this result, an engineered disulfide bond was designed to constrain the alpha5 helix of Galpha(i1) into its EPR-measured receptor-associated conformation through the introduction of cysteines at position 56 in the alpha1 helix and position 333 in the alpha5 helix (I56C/Q333C Galpha(i1)). A functional mimetic of the EPR-measured alpha5 helix dipole movement upon receptor association was additionally created by introduction of a positive charge at the amino terminus of this helix, D328R Galpha(i1). Both proteins exhibit a dramatically elevated level of basal nucleotide exchange. The 2.9 A resolution crystal structure of I56C/Q333C Galpha(i1) in complex with GDP-AlF(4)(-) reveals the shift of the alpha5 helix toward the guanine nucleotide binding site that is anticipated by EPR measurements. The structure of the I56C/Q333C Galpha(i1) subunit further revealed altered positions for the switch regions and throughout the Galpha(i1) subunit, accompanied by significantly elevated crystallographic temperature factors. Combined with previous evidence in the literature, the structural analysis supports the critical role of electrostatics of the alpha5 helix dipole and overall conformational variability during nucleotide release.

36 MATERIALS SCIENCE↗

THE KEPLER PIXEL RESPONSE FUNCTION

Kepler seeks to detect sequences of transits of Earth-size exoplanets orbiting solar-like stars. Such transit signals are on the order of 100 ppm. The high photometric precision demanded by Kepler requires detailed knowledge of how the Kepler pixels respond to starlight during a nominal observation. This information is provided by the Kepler pixel response function (PRF), defined as the composite of Kepler's optical point-spread function, integrated spacecraft pointing jitter during a nominal cadence and other systematic effects. To provide sub-pixel resolution, the PRF is represented as a piecewise-continuous polynomial on a sub-pixel mesh. This continuous representation allows the prediction of a star's flux value on any pixel given the star's pixel position. The advantages and difficulties of this polynomial representation are discussed, including characterization of spatial variation in the PRF and the smoothing of discontinuities between sub-pixel polynomial patches. On-orbit super-resolution measurements of the PRF across the Kepler field of view are described. Two uses of the PRF are presented: the selection of pixels for each star that maximizes the photometric signal-to-noise ratio for that star, and PRF-fitted centroids which provide robust and accurate stellar positions on the CCD, primarily used for attitude and plate scale tracking. Good knowledge of the PRF has been a critical component for the successful collection of high-precision photometry by Kepler.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A teleconnection between Atlantic sea surface temperature and eastern and central North Pacific tropical cyclones

The El Niño–Southern Oscillation (ENSO) is a major source of seasonal tropical cyclone (TC) predictability in both local and remote ocean basins. Unusually warm eastern-central equatorial Pacific sea surface temperature (SST) during El Niño tends to enhance eastern and central North Pacific (ECNP) TCs and suppress Atlantic TCs. Here in this paper, we demonstrate that Atlantic SST variability likewise influences remote TC activity in the eastern-central Pacific through a Walker Circulation-type response analogous to the ENSO-Atlantic TC teleconnection, using observations and 27 km resolution tropical channel model (TCM) simulations. Observed and simulated ECNP TC activity is reduced during the positive Atlantic Meridional Mode (AMM), which is characterized by warm northern and cool southern tropical Atlantic SST anomalies, and vice versa during the negative AMM. Large ensembles of TCM simulations indicate that SST variability, rather than internal atmospheric variability, drives extreme ECNP hurricane seasons.

54 ENVIRONMENTAL SCIENCES↗

Evolution of irradiation defects in Ti 2 AlC ceramics during heavy ion irradiation

Here, the evolution of irradiation defects in Ti 2 AlC under Kr ion irradiation at room and elevated temperatures has been investigated. The dependence of defect size and density on the irradiation dose and temperature was characterized by in-situ transmission electron microscopy (TEM) irradiation experiments. At 25-800 °C, interstitial-type dislocation loops with several nanometers in diameter form on the basal plane of Ti 2 AlC mostly with a Burgers vector of 1/2[0 0 0 1], and no voids have been observed. The number density of dislocation loops approaches saturation at a level of about 2 dpa at 800 °C. Ti 2 AlC samples remain crystalline in structure without amorphization or phase transformation. However, the localized disorder of atomic positions on the basal plane of the irradiated Ti 2 AlC was revealed by high-resolution transmission electron microscopy (HRTEM) studies, which increases with irradiation dose while decreases with elevated temperatures.

36 MATERIALS SCIENCE↗

Global and local texture development during initial plastic deformation of cold-pilgered Zircaloy-4 tubing

In this work we present a thorough characterization of the texture development during the initial step of a cold pilgering process of a Zircaloy-4 TREX tube, on which the axial cross section is reduced by 80% over a 40cm length with an overall Q-ratio of 2.34, followed by a recrystallization thermal treatment. Texture across a tapered specimen representing this working zone was characterized by neutron diffraction and high energy synchrotron x-ray diffraction at 28 positions (4 locations along its length and 7 locations across its thickness with 0.3 mm spatial resolution), and on the deformed end after the thermal treatment. Results show that the starting material (TREX tube) presents a texture gradient through its wall thickness, with the c poles aligned to the hoop direction at the outer surface (with radial and hoop Kearns factors: f R =0.36, f H = 0.50), and gradually rotating around the axial direction to become a quasi-radial orientation (~35 o out of the radial direction) at the inner surface ( f R =0.43, f H =0.35). The overall texture becomes more radial due to the cold pilgering, but the texture gradient remains during the whole deformation process, being always more radial at the inner surface, ( f R =0.53, f H =0.37 at 80%) than at the outer surface ( f R =0.41, f H =0.50at 80%). The most remarkable changes in texture produced by the rolling process is a 30 o rotation of the grains around their c-axis, producing a marked increase of the <11 2 ¯ 0> // axial fiber texture at expenses of the original <10 1 ¯ 0> // axial fiber texture observed in the TREX tube. The observed changes in texture during deformation were correctly explained by visco-plastic self-consistent (VPSC) modelling. This was achieved after the inclusion of the basal <a> slip system, which plays a central role to explain the 30 o rotation around the c-axis during deformation. The texture evolution was correctly described after the inclusion of a drag effect to grain rotation due to the interaction with neighbouring grains. The through thickness texture differences are greatly reduced by the recrystallization thermal treatment, with similar Kearns factors at the inner surface ( f R =0.50, f H =0.28) and the outer surface ( f R =0.48, f H =0.39). The predominance of the <10 1 ¯ 0> // axial fiber texture is recovered after recrystallization.

36 MATERIALS SCIENCE↗

Crystal structure and magnetic properties of complex oxides Mg{sub 4-x}Ni{sub x}Nb{sub 2}O{sub 9}, 0{<=}x{<=}4

In the Mg{sub 4-x}Ni{sub x}Nb{sub 2}O{sub 9} (0{<=}x{<=}4) system two ranges of solid solution have been found. One of the solid solutions has a corundum-related structure type (space group P3-barc1); the second one adopts the II-Ni{sub 4}Nb{sub 2}O{sub 9} structure type (space group Pbcn). The unit cell constants and atomic positions have been determined and refined using neutron powder diffraction data. Electron diffraction and high-resolution transmission electron microscopy (HRTEM) from MgNi{sub 3}Nb{sub 2}O{sub 9} crystals identify the presence of planar defects and the intergrowth of several (structurally related) phases. The magnetic susceptibility of Mg{sub 3}NiNb{sub 2}O{sub 9}, measured in the temperature range T=2-300 K, shows no indications of magnetic ordering at low temperatures, while for MgNi{sub 3}Nb{sub 2}O{sub 9} there is a magnetic ordering at temperatures below 45.5 K. - Graphical abstract: HREM image showing planar defects in MgNi{sub 3}Nb{sub 2}O{sub 9} and their schematic representation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio structure determination and Rietveld refinement of Bi{sub 10}Mo{sub 3}O{sub 24} the member n=3 of the Bi{sub 2n+4}Mo{sub n}O{sub 6(n+1)} series

Bi{sub 2}O{sub 3}-MoO{sub 3} system shows a large panoply of phases depending on Bi/Mo ratio, among them, the low temperature phases of the homologous series Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)} with n=3, 4, 5 and 6. They exhibit, alike most of the phases of this system, strong fluorite sub-network. Nevertheless, a multitechnique approach has been followed in order to solve the crystal structure of the n=3 member, i.e. Bi{sub 10}Mo{sub 3}O{sub 24}. From ab initio indexing X-ray powder pattern cell parameters were derived. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2. The matrix relating this cell with the fluorite one is 4 0 1/0 1 0/-1/2 0 3/2 and a cationic localization was derived. HRTEM allowed the cationic Bi and Mo order to be modified and specified, as well as to build up a full structural ab initio model on the basis of crystal chemistry considerations. Simultaneous Rietveld refinement of multipattern X-ray and neutron powder diffraction data taking advantage of the neutron scattering length for O location have been performed. The goodness of the model was ascertained by low reliability factors, weighted R{sub b}=4.97% and R{sub f}=3.21%. This complex Bi{sub 10}Mo{sub 3}O{sub 24} structure, with 5Bi, 2Mo and 13O in different crystallographic positions of the asymmetric unit, shows good agreement between observed and calculated patterns within the data resolution. Moreover, the determination of this structure sets the basis for the crystallographic characterization of the complete family Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)}, whose guidelines are also evidenced in this paper. - Graphical abstract: This work reports on the ab initio determination of Bi{sub 10}Mo{sub 3}O{sub 24} structure, as well as its refinement by using the Rietveld method, from the combination of X-ray and neutron diffraction powder data. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2.

36 MATERIALS SCIENCE↗

Site specific porosity-thermal performance correlations in neutron irradiated U-10Zr fuel

In this work, we present a site-specific three-dimensional analysis of porosity evolution in neutron-irradiated U–10Zr metallic fuel using high-resolution synchrotron X-ray tomography. Focused ion beam cubic lift-outs from four radial positions—fuel center, middle, edge, and fuel-cladding interaction (FCCI) zones—were imaged, reconstructed, and segmented to quantify pore volume, density, morphology, and pore connectivity. Porosity increased modestly from 5.5% at the center to 10.5% at the edge, yet pore number density increased by over two orders of magnitude in the fuel portion near the FCCI interface (from 4.8 x 10 4 to 6.0 x 10 6 pores/mm 3 ). Morphological classification revealed a progression from small spherical pores at the center to equiaxed and tortuous networks at the periphery, with enhanced orientation along the radial direction. Connectivity and permeability analysis reveal that the FCCI region maintains dense, highly interconnected pores despite a moderate volume fraction, enabling rapid fission gas transport and lanthanide migration. Effective thermal conductivity models incorporating sodium logging confirm that these site-specific pore features critically influenced heat transport during reactor irradiation. These findings demonstrate that pore topology—not just porosity fraction—controls thermal performance and thermal pathways in U–10Zr fuels, impacting fuel thermal performance in a reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Adeno-associated virus-2 and its primary cellular receptor-Cryo-EM structure of a heparin complex

Adeno-associated virus serotype 2 (AAV-2) is a leading candidate vector for gene therapy. Cell entry starts with attachment to a primary receptor, Heparan Sulfate Proteoglycan (HSPG) before binding to a co-receptor. Here, cryo-electron microscopy provides direct visualization of the virus-HSPG interactions. Single particle analysis was performed on AAV-2 complexed with a 17 kDa heparin fragment at 8.3 A resolution. Heparin density covers the shoulder of spikes surrounding viral 3-fold symmetry axes. Previously implicated, positively charged residues R{sub 448/585}, R{sub 451/588} and R{sub 350/487} from another subunit cluster at the center of the heparin footprint. The footprint is much more extensive than apparent through mutagenesis, including R{sub 347/484}, K{sub 395/532} and K{sub 390/527} that are more conserved, but whose roles have been controversial. It also includes much of a region proposed as a co-receptor site, because prior studies had not revealed heparin interactions. Heparin density bridges over the viral 3-fold axes, indicating multi-valent attachment to symmetry-related binding sites.

60 APPLIED LIFE SCIENCES↗

TANAMI blazars in the IceCube PeV-neutrino fields

The IceCube Collaboration has announced the discovery of a neutrino flux in excess of the atmospheric background. Owing to the steeply falling atmospheric background spectrum, events at PeV energies most likely have an extraterrestrial origin. We present the multiwavelength properties of the six radio-brightest blazars that are positionally coincident with these events using contemporaneous data of the TANAMI blazar sample, including high-resolution images and spectral energy distributions. Assuming the X-ray to γ-ray emission originates in the photoproduction of pions by accelerated protons, the integrated predicted neutrino luminosity of these sources is high enough to explain the two detected PeV events.

79 ASTRONOMY AND ASTROPHYSICS↗

Pattern recognition techniques to reduce backgrounds in the search for the {sup 136}Xe double beta decay with gaseous TPCs

The observation of the neutrinoless double beta decay may provide essential information on the nature of neutrinos. Among the current experimental approaches, a high pressure gaseous TPC is an attractive option for the search of double beta decay due to its good energy resolution and the detailed topological information of each event. We present in this talk a detailed study of the ionization topology of the {sup 136}Xe double beta decay events in a High Pressure Xenon TPC, as well as that of the typical competing backgrounds. We define some observables based on graph theory concepts to develop automated discrimination algorithms. Our criteria are able to reduce the background level by about three orders of magnitude in the region of interest of the {sup 136}Xe Q{sub ββ} for a signal acceptance of 40%. This result provides a quantitative assessment of the benefit of topological information offered by gaseous TPCs for double beta decay search, and proves that it is a promising feature in view of future experiments in the field. Possible ideas for further improvement in the discrimination algorithms and the dependency of these results with the gas diffusion and readout granularity will be also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of extended magnetic probe set to improve 3D field detection in NSTX-U

Adding toroidal arrays of magnetic probes at the top and bottom of NSTX-U would improve both the detection of the multimodal plasma response to applied magnetic perturbations and the identification of the poloidal structure of unstable plasma modes, as well as contribute to the validation of MHD models, improve the understanding of the plasma response to external fields, and improve the error field correction. In this paper, the linear MHD code MARS-F/K has been used to identify poloidal locations that would improve the capability to measure stationary or near-stationary 3D fields that may result from the plasma response to external sources of non-axisymmetric fields. The study highlighted 6 poloidal positions where new arrays of both poloidal and radial magnetic field sensors would improve the poloidal resolution. Here, the proposed set of new arrays combined with the present ones is shown to be capable of measuring the poloidal structure of perturbations with n ≤ 6 and of detecting the multimodal plasma response. Assessment of the trade-off in the poloidal length of the probes leads to an ideal length between 10 cm and 30 cm. A method to configure the probes of a toroidal array based on the singular value decomposition condition number is proposed, and an ideal solution and a low-cost one are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VLBI DETECTION OF AN ACTIVE GALACTIC NUCLEUS PAIR IN THE BINARY BLACK HOLE CANDIDATE SDSS J1536+0441

We present the first pc-scale radio imaging of the radio-quiet candidate binary black hole system SDSS J1536+0441. The observations were carried out by the European VLBI Network at a frequency of 5 GHz, allowing the imaging of SDSS J1536+0441 with a resolution of {approx}10 mas ({approx}50 pc). Two compact radio cores are detected at the position of the kpc-scale components VLA-A and VLA-B, proving the presence of two compact active nuclei with radio luminosity L{sub R} {approx} 10{sup 40} erg s{sup -1}, thus ruling out the possibility that both radio sources are powered by a 0.1 pc binary black hole. From a comparison with published 8.5 GHz flux densities, we derived an estimate of the radio spectral index of the two pc-scale cores. Both cores have a flat or an inverted spectral index, and at least for the case of VLA-A we can rule out the possibility that synchrotron self-absorption is responsible for the inverted radio spectrum. We suggest that thermal free-free emission from an X-ray-heated disk wind may be powering the radio emission in VLA-A.

79 ASTRONOMY AND ASTROPHYSICS↗

TOTAL MOLECULAR GAS MASSES OF z {approx} 3 LYMAN- BREAK GALAXIES: CO(J = 1 {yields} 0) EMISSION IN MS 1512-cB58 AND THE COSMIC EYE

We report the detection of CO(J = 1 {yields} 0) emission toward the lensed L {sup *} {sub UV} Lyman-break galaxies (LBGs) MS 1512-cB58 (z = 2.73) and the Cosmic Eye (z = 3.07), using the Expanded Very Large Array. The strength of the CO line emission reveals molecular gas reservoirs with masses of (4.6 {+-} 1.1) x 10{sup 8} ({mu}{sub L}/32){sup -1} ({alpha}{sub CO}/0.8) M {sub sun} and (9.3 {+-} 1.6) x 10{sup 8} ({mu}{sub L}/28){sup -1} ({alpha}{sub CO}/0.8) M {sub sun}, respectively. These observations suggest {approx}30%-40% larger gas reservoirs than previously estimated based on CO(J = 3 {yields} 2) observations due to subthermal excitation of the J = 3 line. These observations also suggest gas mass fractions of 0.46 {+-} 0.17 and 0.16 {+-} 0.06. The CO(J = 1 {yields} 0) emission in the Cosmic Eye is slightly resolved on scales of 4.''5 {+-} 1.''5, consistent with previous studies of nebular emission lines. This suggests that the molecular gas is associated with the most intensely star-forming regions seen in the ultraviolet (UV). We do not resolve the CO(J = 1 {yields} 0) emission in cB58 at {approx}2'' resolution, but find that the CO(J = 1 {yields} 0) emission is also consistent with the position of the UV-brightest emission peak. The gas masses, gas fractions, moderate CO line excitation, and star formation efficiencies in these galaxies are consistent with what is found in nearby luminous infrared galaxies. These observations thus currently represent the best constraints on the molecular gas content of 'ordinary' (i.e., {approx}L* {sub UV}) z {approx} 3 star-forming galaxies. Despite comparable star formation rates, the gas properties of these young LBGs seem to be different from the recently identified optical/infrared-selected high-z massive, gas-rich star-forming galaxies, which are more gas-rich and massive, but have lower star formation efficiencies, and presumably trace a different galaxy population.

79 ASTRONOMY AND ASTROPHYSICS↗