Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Simulate Wind Loading on RUTE SunTracker: Cooperative Research and Development (Final Report)

RUTE produces and delivers efficient, sustainable structural foundation systems for the wind and solar industries, instrumental in the effort to lower the cost of clean electricity and reduce CO2. RUTE's SunTracker is a high-clearance agrivoltaic solar array. The system uses raised cables, providing support with less materials and cost. These cables can provide tracking for increased energy generation and greater revenue, allowing the land beneath to be used for other means simultaneously. RUTE provided data files that NREL will use to perform computational fluid dynamics (CFD) simulations to characterize and predict wind loading on the 6x6 RUTE SunTracker photovoltaic (PV) array. Varying both the panel orientations and wind speeds provides information on how the array can manage a variety of weather conditions. These results, in turn, inform RUTE's design and construction of these arrays.

14 SOLAR ENERGY↗

InGaAs PV Device Development for TPV Power Systems

Indium gallium arsenide (InGaAs) photovoltaic devices have been fabricated with bandgaps ranging from 0.75 eV to 0.60 eV on Indium Phosphide (InP) substrates. Reported efficiencies have been as high as 11.2 percent (AMO) for the lattice matched 0.75 eV devices. The 0.75 eV cell demonstrated 14.8 percent efficiency under a 1500 K blackbody with a projected efficiency of 29.3 percent. The lattice mismatched devices (0.66 and 0.60 eV) demonstrated measured efficiencies of 8 percent and 6 percent respectively under similar conditions. Low long wavelength response and high dark currents are responsible for the poor performance of the mismatched devices. Temperature coefficients have been measured and are presented for all of the bandgaps tested.

Wilt, David M.↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Energy Northwest - Horn Rapids Solar and Storage: An Assessment of Battery Technical Performance

Chartered in 1957 as a joint action agency of the state, Energy Northwest (ENW) is a consortium of 27 public utility districts and municipalities across Washington state. ENW takes advantage of economies of scale and shared services to help utilities run their operations more efficiently and at lower cost, to the benefit of more than 1.5 million customers. ENW develops, owns, and operates a diverse mix of electricity generating resources, including hydro, solar, and wind projects – and the Northwest’s only active nuclear energy facility. These projects provide enough reliable, affordable, and environmentally responsible energy to power more than a million homes each year, and that carbon-free electricity is provided at the cost of generation. The agency continually explores new generation projects to meet its members’ needs. In 2017, as part of the second round of funding from the Washington state Clean Energy Fund, the Washington State Department of Commerce granted up to $3 million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/5.5 MWh lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. The City of Richland will purchase the power from the project and utilize the benefits of the energy storage. The project provides Washington state with its first opportunity to integrate a large-scale solar and storage facility into its clean mix of hydro, nuclear, and wind resources. This first-of-its-kind facility combines solar generation with battery storage and technician training. In 2019, Pacific Northwest National Laboratory (PNNL) worked with ENW to assess the integrated PV and BESS in representative use cases that could benefit the City of Richland. Between March and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (A) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline), and they are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (B) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with ENW. Five use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) transmission charge reduction, 4) Volt-VAR service, and 5) outage mitigation. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help ENW understand the performance of the Horn Rapids BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

FACT, Mega-ROSA, SOLAROSA

The Flexible Array Concentrator Technology (FACT) is a lightweight, high-performance reflective concentrator blanket assembly that can be used on flexible solar array blankets. The FACT concentrator replaces every other row of solar cells on a solar array blanket, significantly reducing the cost of the array. The modular design is highly scalable for the array system designer, and exhibits compact stowage, good off-pointing acceptance, and mass/cost savings. The assembly s relatively low concentration ratio, accompanied by a large radiative area, provides for a low cell operating temperature, and eliminates many of the thermal problems inherent in high-concentration-ratio designs. Unlike other reflector technologies, the FACT concentrator modules function on both z-fold and rolled flexible solar array blankets, as well as rigid array systems. Mega-ROSA (Mega Roll-Out Solar Array) is a new, highly modularized and extremely scalable version of ROSA that provides immense power level range capability from 100 kW to several MW in size. Mega-ROSA will enable extremely high-power spacecraft and SEP-powered missions, including space-tug and largescale planetary science and lunar/asteroid exploration missions. Mega-ROSA's inherent broad power scalability is achieved while retaining ROSA s solar array performance metrics and missionenabling features for lightweight, compact stowage volume and affordability. This innovation will enable future ultra-high-power missions through lowcost (25 to 50% cost savings, depending on PV and blanket technology), lightweight, high specific power (greater than 200 to 400 Watts per kilogram BOL (beginning-of-life) at the wing level depending on PV and blanket technology), compact stowage volume (greater than 50 kilowatts per cubic meter for very large arrays), high reliability, platform simplicity (low failure modes), high deployed strength/stiffness when scaled to huge sizes, and high-voltage operation capability. Mega-ROSA is adaptable to all photovoltaic and concentrator flexible blanket technologies, and can readily accommodate standard multijunction and emerging ultra-lightweight IMM (inverted metamorphic) photovoltaic flexible blanket assemblies, as well as ENTECHs Stretched Lens Array (SLA) and DSSs (Deployable Space Systems) FACT, which allows for cost reduction at the array level.

Spence, Brian↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Model Validation of PV Inverters Under Short-Circuit Conditions: Preprint

Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.

14 SOLAR ENERGY↗

A Practical Irradiance Model for Bifacial PV Modules

A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-ofincidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using ray tracing software.

14 SOLAR ENERGY↗

A Practical Irradiance Model for Bifacial PV Modules

A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using ray tracing software.

14 SOLAR ENERGY↗

Gaps in PV-Coupled Battery Modeling

With the rapid increase in battery attachment rates for PV systems and the continued qualification of storage for the ITC under OBBB, accurately characterizing PV-coupled batteries is becoming increasingly critical for the PV industry. This presentation will explore the key gaps in current best practices for modeling PV-coupled battery storage, including challenges such as battery thermal conditioning, the influence of dispatch strategies on battery value, the limitations of oversimplified degradation and performance models, and the absence of a centralized database containing sufficient battery parameters for accurate modeling. For behind-the-meter applications, we will also address issues like mismatched solar resource and load profiles, as well as uncertainties in future utility rates. Where applicable, we will quantify the impacts of these gaps on the accuracy and uncertainty of modeling efforts and highlight ongoing research aimed at addressing these challenges.

14 SOLAR ENERGY↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

Western Wind and Solar Integration Study

The Western Wind and Solar Integration Study (WWSIS) is one of the largest regional wind and solar integration studies to date. It was initiated in 2007 to examine the operational impact of up to 35% energy penetration of wind, photovoltaics (PV), and concentrating solar power (CSP) on the power system operated by the WestConnect group of utilities in Arizona, Colorado, Nevada, New Mexico, and Wyoming (see study area map). WestConnect also includes utilities in California, but these were not included because California had already completed a renewable energy integration study for the state. This study was set up to answer questions that utilities, public utilities commissions, developers, and regional planning organizations had about renewable energy use in the west: (1) Does geographic diversity of renewable energy resource help mitigate variability; (2) How do local resources compare to out-of-state resources; (3) Can balancing area cooperation help mitigate variability; (4) What is the role and value of energy storage; (5) Should reserve requirements be modified; (6) What is the benefit of forecasting; and (7) How can hydropower help with integration of renewables? The Western Wind and Solar Integration Study is sponsored by the U.S. Department of Energy (DOE) and run by NREL with WestConnect as a partner organization. The study follows DOE's 20% Wind Energy by 2030 report, which did not find any technical barriers to reaching 20% wind energy in the continental United States by 2030. This study and its partner study, the Eastern Wind Integration and Transmission Study, performed a more in-depth operating impact analysis to see if 20% wind energy was feasible from an operational level. In DOE/NREL's analysis, the 20% wind energy target required 25% wind energy in the western interconnection; therefore, this study considered 20% and 30% wind energy to bracket the DOE analysis. Additionally, since solar is rapidly growing in the west, 5% solar was also considered in this study. The goal of the Western Wind and Solar Integration Study is to understand the costs and operating impacts due to the variability and uncertainty of wind, PV, and CSP on the grid. This is mainly an operations study, (rather than a transmission study), although different scenarios model different transmission build-outs to deliver power. Using a detailed power system production simulation model, the study identifies operational impacts and challenges of wind energy penetration up to 30% of annual electricity consumption.

14 SOLAR ENERGY↗

A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell

Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

14 SOLAR ENERGY↗

The Impact of TRMM on Mesoscale Model Simulation of Super Typhoon Paka

Tropical cyclone Paka formed during the first week of December 1997 and underwent three periods of rapid intensification over the following two weeks. During one of these periods, which initiated early on December 10, Paka's Dvorak-measured windspeed increased from 23 to 60 m/s over a 48-hr period. On December 18, during the last rapid deepening episode, Paka became a supertyphoon with a maximum wind speed of about 80 m/s. In this study, the Penn State/NCAR Mesoscale Model (MM5) with improved physics (i.e., cloud microphysics, radiation, land-soil-vegetation-surface processes, and TOGA COARE flux scheme) and a multiple level nesting technique (135, 45 and 15 km horizontal resolution) will be used to simulate supertyphoon Paka. We performed two runs initialized with Goddard Earth Observing System (GEOS) data sets. The first GEOS data set does not incorporate either TRMM (tropical rainfall measuring mission satellite) or SSM/I (sensor microwave imager) observed rainfall fields into the GEOS's assimilation system while the second one does. Preliminary results show that the MM5 simulated surface pressure deepened by more than 25 mb (45 km resolution domain) in the run initialized with the GEOS data set incorporating TRMM and SSM/I derived rainfall, compared to the one initialized without. However, the track and precipitation patterns are quite similar between the runs. In our presentation, we will show the impact of TRMM rainfall upon the MM5 simulation of Paka at various horizontal resolutions. We will also examine the physical processes associated with initial explosive development by comparing MM5 simulated rainfall and latent heat release. In addition, budget (vorticity, PV, momentum and heat) calculations and sensitivity tests will be performed to examine the upper-tropospheric and SST mechanisms responsible for the explosive development of Paka.

Tao, W.-K.↗

Experimental investigation and modeling of a direct-coupled PV/T air collector

Photovoltaic/thermal (PV/T) systems refer to the integration of photovoltaic and solar thermal technologies into one single system, in that both useful heat energy and electricity are produced. The impetus of this paper is to model a direct-coupled PV/T air collector which is designed, built, and tested at a geographic location of Kerman, Iran. In this system, a thin aluminum sheet suspended at the middle of air channel is used to increase the heat exchange surface and consequently improve heat extraction from PV panels. This PV/T system is tested in natural convection and forced convection (with two, four and eight fans operating) and its unsteady results are presented in with and without glass cover cases. A theoretical model is developed and validated against experimental data, where good agreement between the measured values and those calculated by the simulation model were achieved. Comparisons are made between electrical performance of the different modes of operation, and it is concluded that there is an optimum number of fans for achieving maximum electrical efficiency. Also, results show that setting glass cover on photovoltaic panels leads to an increase in thermal efficiency and decrease in electrical efficiency of the system. (author)

14 SOLAR ENERGY↗

Addressing Soiling: From Interface Chemistry to Practicality

Natural soiling has reduced the energy output of photovoltaic (PV) systems since the technology was first used. Projecting even a small average annual soiling loss translates to billions of dollars in annual lost revenue worldwide. Production losses due to soiling can be very high in some locations, substantially increasing the levelized cost of electricity (LCOE) due to lost power production, increased operating and maintenance costs, and/or increased finance cost due to the uncertainty. Furthermore, although soiling has been discussed in the literature for more than 70 years, solutions to many problems are still needed. The National Renewable Energy Laboratory (NREL) is working with the PV industry to develop the tools/knowledge so that the effects of soiling can be predicted for different environmental conditions and cost-effective mitigation can be implemented. For this project, NREL performed a number of research and development tasks/subtasks in the following general areas to 1) predict PV module soiling losses based on environmental factors at a PV installation and from its energy production data, 2) quantitatively measure the adhesion forces to understand the physics enabling soiling, and 3) develop related standards on PV module coatings and artificial soiling. At the inception of the project, the PV industry considered these efforts to be the most important and immediate soiling issues that we could address to have the highest impact on LCOE. These focused efforts have led to outstanding accomplishments that have been communicated and very well received by the community.

14 SOLAR ENERGY↗