Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

A Convolution Neural Network for Voltage Event Classification at a Photovoltaic Inverter

This paper presents a convolutional neural network (CNN) developed to identify voltage events in photovoltaic (PV) inverters. The CNN is trained on synthetic data generated using the IEEE 13-bus distribution feeder model and evaluated on field measured data collected from Energy Northwest’s Horn Rapids Solar, Storage, and Training (HRSST) facility. The study focuses on two common voltage events: faults and voltage sags. The CNN is configured to analyze voltage and current waveforms from three-phase PV systems, demonstrating excellent accuracy during training. Field data from the HRSST facility is employed to assess its real-world performance, where the CNN achieves perfect identification of faults and voltage sags in a sample of nine events. This work highlights the potential of the proposed method to enhance PV protection schemes, providing a robust foundation for improved voltage event detection and grid reliability.

Cornachione, Matthew A.↗

Options for improving the load matching capability of distributed photovoltaics: Methodology and application to high-latitude data

At high latitudes, domestic electricity demand and insolation are negatively correlated on both an annual and a diurnal basis. With increasing integration of distributed photovoltaics (PV) in low-voltage distribution grids of residential areas, limits to the penetration level are set by voltage rise due to unmatched production and load. In this paper a methodology for determining the impacts of three options for increased load matching is presented and applied to high-latitude data. The studied options are PV array orientation, demand side management (DSM) and electricity storage. Detailed models for domestic electricity demand and PV output are used. An optimisation approach is applied to find an optimal distribution of PV systems on different array orientations and a best-case evaluation of DSM and a storage model are implemented. At high penetration levels, storage is the most efficient option for maximising the solar fraction, but at lower overproduction levels, the impact of DSM is equal or slightly better. An east-west orientation of PV arrays is suggested for high penetration levels, but the effect of the optimised orientation is small. Without an optimised storage operation, the overproduced power is more efficiently reduced by DSM than storage, although this is highly dependent on the applied DSM algorithm. Further research should be focused on the DSM potential and optimal operation of storage. (author)

14 SOLAR ENERGY↗

Potential of Renewable Energy to Reduce the Dependence of the State of Hawaii on Oil

Deriving nearly 90% of its primary energy resources from oil, the State of Hawaii is more dependent on oil than any other U.S. state. The price of electricity in Hawaii is also more than twice the U.S. average. The Energy Policy Act of 2005 directed assessment of the economic implications of Hawaii's oil dependence and the feasibility of using renewable energy to help meet the state's electrical generation and transportation fuel use. This paper is based on the assessments and report prepared in response to that directive.Current total installed electrical capacity for the State of Hawaii is 2,414 MWe, 83% of which is fuel-oil generated, but already including about 170 MWe of renewable capacity. The assessments identified about 2,133 MWe (plus another estimated 2,000 MWe of rooftop PV systems) of potential new renewable energy capacity. Most notable, in addition to the rooftop solar potential, is 750 MWe and 140 MWe of geothermal potential on Hawaii and Maui, respectively, 840 MWe of potential wind capacity, primarily on Lanai and Molokai, and one potential 285 MWe capacity specific solar project (PV or solar thermal) identified on Kauai. Important social, political, and electrical-grid infrastructure challenges would need to be overcome to realize this potential. Among multiple crop and acreage scenarios, biofuels assessment found 360,000 acres in Hawaii zoned for agriculture and appropriate for sugarcane, enough to produce 429 million gallons of ethanol-enough to meet about 64% of current 2005 Hawaiian gasoline use. Tropical oil seed crops-potentially grown on the same land-might meet a substantial portion of current diesel use, but there has been little experience growing such crops in Hawaii. The U.S. Department of Energy and the State of Hawaii initiated in January 2008 a program that seeks to reduce Hawaii's oil dependence and provide 70% of the state's primary energy from clean energy sources by 2030. The Hawaii Clean Energy Initiative (HCEI) activities will be concentrated in two areas: (1) HCEI Working Groups will be formed and made up of private, state, and U.S. government experts in the areas of Transportation and Fuels, Electricity Generation, Energy Delivery and Transmission, and End-Use Efficiency; and (2) Partnership Projects will be undertaken with local and mainland partners that demonstrate and commercialize new technologies and relieve technical barriers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Repair and Resource Scheduling in Unbalanced Distribution Systems Using Neighborhood Search

—This paper proposes an optimization strategy to assist utility operators to recover power distribution systems after large outages. Specifically, a mixed-integer linear programming (MILP) model is developed for co-optimizing crews, resources, and network operations. The MILP model coordinates damage isolation, network reconfiguration, distributed generator re-dispatch, and crew/resource logistics. In addition, a framework for integrating different types of photovoltaic (PV) systems in the restoration process is developed. We consider two different types of crews, namely, line crews for damage repair and tree crews for obstacle removal. We also model the repair resource logistic constraints. Furthermore, a new algorithm is developed for solving the distribution system repair and restoration problem (DSRRP). The algorithm starts by solving DSRRP using an assignmentbased method, then a neighborhood search method is designed to iteratively improve the solution. The proposed method is validated on modified IEEE 123- and 8500-bus distribution test systems.

Outage management↗

Quantifying Soiling Loss Directly From PV Yield

Soiling of photovoltaic (PV) panels is typically quantified through the use of specialized sensors. Here, we describe and validate a method for estimating soiling loss experienced by PV systems directly from system yield without the need for precipitation data. The method, termed the stochastic rate and recovery (SRR) method, automatically detects soiling intervals in a dataset, then stochastically generates a sample of possible soiling profiles based on the observed characteristics of each interval. In this paper, we describe the method, validate it against soiling station measurements, and compare it with other PV-yield-based soiling estimation methods. The broader application of the SRR method will enable the fleet scale assessment of soiling loss to facilitate mitigation planning and risk assessment.

14 SOLAR ENERGY↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

14 SOLAR ENERGY↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez↗

Marrying Quality Assurance with Design Engineering - A Winning Partnership! But, a Cultural Divide

Investors would like to be confident that a PV plant will work as promised before investing large sums of money. Data showing that PV modules can withstand thousands of hours of accelerated testing are a comfort, but are not sufficient to characterize the economic useful life (EUL) of the whole PV system. An inability to be confident of every aspect of the system can motivate less favorable contract terms. In the end, a winning partnership is obtained when a carefully engineered, durable design is married with a robust quality management system and the marriage is extended across all parts of the value chain. However, this marriage is challenging because of the conventional cultural divide between design engineers and quality management specialists. International standards are being developed to facilitate this partnership and include technology-specific requirements in the quality management systems used for component manufacture and system design, construction and operation.

14 SOLAR ENERGY↗

Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

14 SOLAR ENERGY↗

Very High Efficiency Solar Cell Modules

The Very High Efficiency Solar Cell (VHESC) program is developing integrated optical system - PV modules for portable applications that operate at greater than 50% efficiency. We are integrating the optical design with the solar cell design, and have entered previously unoccupied design space. Our approach is driven by proven quantitative models for the solar cell design, the optical design, and the integration of these designs. Optical systems efficiency with an optical efficiency of 93% and solar cell device results under ideal dichroic splitting optics summing to 42.7 {+-} 2.5% are described.

14 SOLAR ENERGY↗

Deep Learning-Based Failure Prognostic Model for PV Inverter Using Field Measurements

Here, this study presents a novel approach for the precise monitoring and prognosis of photovoltaic (PV) inverter status, which is crucial for the proactive maintenance of PV systems. It addresses the gaps in traditional model-based methods, which tend to neglect the overall reliability of inverters, and the limitations of data-driven approaches that largely depend on simulated data. This research presents a robust solution applicable to real-world scenarios. The proposed data-driven model for PV inverter failure prognosis employs actual inverter measurements, integrating various operational and weather-related factors based on domain knowledge. This approach effectively represents inverter stressors and operational status. Utilizing an Enhanced Siamese Convolutional Neural Network (ESCNN), the model merges operational data with domain knowledge features, redefining the prognosis challenge as a classification task. Furthermore, the paper discusses an ESCNN-based real-time inverter failure monitoring method developed on the well-trained model. The proposed models are rigorously trained and tested with real inverter data and a novel filtering method is included to address accidental failures in practical scenarios. The results validate the model's efficacy, and the directions for future research are also outlined.

42 ENGINEERING↗

Photovoltaic Module R&D Considerations for Soiling Mitigation

Photovoltaic (PV) modules work best in the sunniest environments. Unfortunately, often the sunniest places also have substantial amounts of airborne "dust" that deposits on the front surface of the modules and blocks the sunlight; reducing energy output. In fact, natural soiling has reduced the energy output of PV systems since the technology was first used, and viable mitigation strategies have remained elusive ever since. With the ever-increasing deployments around the world, especially in dusty environments, soiling is becoming a billion-dollar problem, worldwide. While substantial work has been done to examine and resolve some of the issues with PV soiling, often mitigation comes down to physically cleaning the modules. However, a more systematic evaluation of the different module properties correlations to soiling mitigation needs to be done. In many instances, the causal connections between module properties and soiling are simply not known. This lack of knowledge results in a substantial increase in time and effort to evaluate and qualify appropriate soiling mitigation protocols based on site specific issues and the intrinsic module properties that are typically not optimized for mitigating soiling in a given environment. Thus, module property protocols and/or standards are needed to more quickly help identify appropriate module and site-specific mitigation.

mitagation↗

Compensation for Distributed Solar. A Survey of Options to Preserve Stakeholder Value

Compensation mechanisms for electricity generation systems installed behind the meter are under scrutiny in several jurisdictions in the United States. Legislators in 29 states introduced bills to amend net metering provisions in 2014, and in 33 states in the 2015 legislative session as of August 20, 2015. Some utilities have also sought to increase the revenue they receive from net-metered customers through rate redesign. The circumstances that have triggered the recent push for change include a growing percentage of net-metered customers, potential effects of distributed generation on cost allocation, decreasing photovoltaic (PV) system costs, the challenges of integrating high levels of solar generation in the distribution network, and increasing pressure on utility business models. This report presents a survey of options to charge and compensate PV customers, as well as options that may preserve utility revenues in scenarios with increased DG. These options could be used as building blocks to create a distributed generation (DG) compensation policy that may preserve the value of the different stakeholders and balance their interests.

14 SOLAR ENERGY↗

Standards development for modules in high temperature micro-environments

Photovoltaic (PV) module qualification standards, IEC 61215 and IEC 61730, were designed to apply to “general open-air climates” and IEC 61730 specifically indicated applicability of ambient air temperature of 40°C. Additionally, these standards provided allowances for so-called “open rack mounted PV modules” without a clear definition of “open-rack.” These implied restrictions and allowances meant that hotter climates or thermally restrictive installation methods may not be covered by these often customer-mandated certification standards. This is particularly salient for the significant growth regions of the Middle East and India that would be expected to operate at significantly higher temperatures. The applicability of these documents raised issues over the definition of “open rack” and the fact that the geographic location is just as important as the mounting configuration in assessing the impact of the micro-environment of a PV module. This work summarizes the scientific background for IEC Technical Specification 63126:2020 ED1, titled “Guidelines for qualifying PV modules components and materials for operation at high temperatures.” This standard was recently published by the IEC and is the first step in a systematic effort to rework these standards to address the question of temperature more directly. Instead of specifying a mounting condition, we specify different suites of tests suitable for a system (PV module, mounting style, and location) defined by the 98th percentile cell temperature. With a defined temperature regime to work from, this allowed us to use existing literature research combined with additional modeling work to determine, which tests would need to be modified. This resulted in suggested changes to material thermal indices, thermal cycling temperatures, hot spot testing, ultraviolet testing, and bypass diode testing among other tests and characteristics described in this study.

14 SOLAR ENERGY↗

Resampling and data augmentation for short-term PV output prediction based on an imbalanced sky images dataset using convolutional neural networks

Integrating photovoltaics (PV) into electricity grids is challenged by potentially large fluctuations in power generation. In recent years, sky image-based PV output prediction using convolutional neural networks (CNNs) has emerged as a promising approach to forecasting fluctuations. A key challenge is imbalanced sky image datasets: because of the geography of solar PV system installations, sky image datasets are often rich in sunny condition data but deficient in cloudy condition data. This imbalance contrasts with the fact that model errors are dominated by cloudy condition performance. In this study, we attempt to remedy this by exploring the enrichment and augmentation of an imbalanced sky images dataset for two PV output prediction tasks: nowcasting (predicting concurrent PV output) and forecasting (predicting 15-minute-ahead future PV output). We empirically examine the efficacy of using different resampling and data augmentation approaches to create a rebalanced dataset for model development. A three-stage greedy search is used to determine the optimal resampling approach, data augmentation techniques and over-sampling rate. The results show that for the nowcast problem, resampling and data augmentation can effectively enhance the model performance, reducing overall root mean squared error (RMSE) by an average of 4%, or a 15 std. (standard deviation) of improvement compared to the variability of the baseline model. In contrast, the treatment RMSE for the forecast problem nearly always overlaps the baseline performance at the ± 2 std. level. The optimal resampling approach expands on the original dataset by over-sampling the minority cloudy data, with the best results from large over-sampling rate (e.g., 4 ~ 6 times over-sampling of cloudy images).

14 SOLAR ENERGY↗