Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Probing drift velocity dispersion in MAPbI 3 photovoltaic cells with nonlinear photocurrent spectroscopy

Conventional time-of-flight (TOF) measurements yield charge carrier mobilities in photovoltaic cells with time resolution limited by the RC time constant of the device, which is on the order of 0.1–1 µs for the systems targeted in the present work. We have recently developed an alternate TOF method, termed nonlinear photocurrent spectroscopy (NLPC), in which carrier drift velocities are determined with picosecond time resolution by applying a pair of laser pulses to a device with an experimentally controlled delay time. In this technique, carriers photoexcited by the first laser pulse are “probed” by way of recombination processes involving carriers associated with the second laser pulse. Here, we report NLPC measurements conducted with a simplified experimental apparatus in which synchronized 40 ps diode lasers enable delay times up to 100 µs at 5 kHz repetition rates. Carrier mobilities of ∼0.025 cm 2 /V/s are determined for MAPbI 3 photovoltaic cells with active layer thicknesses of 240 and 460 nm using this instrument. Here, our experiments and model calculations suggest that the nonlinear response of the photocurrent weakens as the carrier densities photoexcited by the first laser pulse trap and broaden while traversing the active layer of a device. Based on this aspect of the signal generation mechanism, experiments conducted with co-propagating and counter-propagating laser beam geometries are leveraged to determine a 60 nm length scale of drift velocity dispersion in MAPbI 3 films. Contributions from localized states induced by thermal fluctuations are consistent with drift velocity dispersion on this length scale.

14 SOLAR ENERGY↗

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of plasmon relaxation mechanisms using nonadiabatic molecular dynamics

Hot carriers generated from the decay of plasmon excitation can be harvested to drive a wide range of physical or chemical processes. However, their generation efficiency is limited by the concomitant phonon-induced relaxation processes by which the energy in excited carriers is transformed into heat. However, simulations of dynamics of nanoscale clusters are challenging due to the computational complexity involved. Here, in this paper, we adopt our newly developed Trajectory Surface Hopping (TSH) nonadiabatic molecular dynamics algorithm to simulate plasmon relaxation in Au 20 clusters, taking the atomistic details into account. The electronic properties are treated within the Linear Response Time-Dependent Tight-binding Density Functional Theory (LR-TDDFTB) framework. The relaxation of plasmon due to coupling to phonon modes in Au 20 beyond the Born–Oppenheimer approximation is described by the TSH algorithm. The numerically efficient LR-TDDFTB method allows us to address a dense manifold of excited states to ensure the inclusion of plasmon excitation. Starting from the photoexcited plasmon states in Au 20 cluster, we find that the time constant for relaxation from plasmon excited states to the lowest excited states is about 2.7 ps, mainly resulting from a stepwise decay process caused by low-frequency phonons of the Au 20 cluster. Furthermore, our simulations show that the lifetime of the phonon-induced plasmon dephasing process is ~10.4 fs and that such a swift process can be attributed to the strong nonadiabatic effect in small clusters. Our simulations demonstrate a detailed description of the dynamic processes in nanoclusters, including plasmon excitation, hot carrier generation from plasmon excitation dephasing, and the subsequent phonon-induced relaxation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Electronic heat generation in semiconductors: Non-equilibrium excitation and evolution of zone-edge phonons via electron–phonon scattering in photo-excited germanium

We investigate experimentally and using first-principles theory the generation of phonons and the relaxation of carriers on picosecond timescales across the Brillouin zone of photo-excited Ge by inter-valley electron–phonon scattering. The phonons generated are typical of those generated in semiconductor devices, contributing to the accumulation of heat within the material. We simulate the time-evolution of phonon populations, based on first-principles band structure and electron–phonon and phonon–phonon matrix elements, and compare them to data from time-resolved x-ray diffuse scattering experiments, performed at the Linac Coherent Light Source x-ray free-electron laser facility, following photo-excitation by a 50 fs near-infrared optical pulse. We show that the intensity of the non-thermal x-ray diffuse scattering signal, which is observed to grow substantially near the L-point of the Brillouin zone over 3–5 ps, is due to phonons generated by scattering of carriers between the Δ and L valleys. These phonons have low group velocities, resulting in a heat bottleneck. With the inclusion of phonon decay through 3-phonon processes, the simulations also account for other non-thermal features observed in the x-ray diffuse scattering intensity, which are due to anharmonic phonon–phonon scattering of the phonons initially generated by electron–phonon scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Proton acceleration in an overdense hydrogen plasma by intense CO 2 laser pulses with nonlinear propagation effects in the underdense pre-plasma

We report on proton acceleration from intense CO 2 laser-irradiated hydrogen plasmas at near-critical densities, with the density gradient steepened by Nd:YAG laser ablation-driven hydrodynamic shocks. While the experimental results, such as the quasi-monoenergetic proton spectra and their scaling with respect to the laser energy, are generally in agreement with the simulations, certain laser shots produced significantly higher proton energies than anticipated during the experiment. The increased proton energy may be linked to nonlinear propagation effects in the steepened plasma density ramp before the critical surface, including relativistic self-focusing and, for the case of temporally-structured laser pulses observed in the experiment, focusing of the trailing pulse through the plasma channel formed by the leading pulse 25 ps ahead. The occurrence of channel focusing in the underdense hydrogen plasma is supported by a subsequent pump-probe experiment with a dark-field imaging technique, where the formation of ion channels was observed after the passage of an intense CO 2 laser pulse

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Picosecond magneto-optic thermometry measurements of nanoscale thermal transport in AlN thin films

The thermal conductivity Λ of wide bandgap semiconductor thin films, such as AlN, affects the performance of high-frequency devices, power devices, and optoelectronics. However, accurate measurements of Λ in thin films with sub-micrometer thicknesses and Λ > 100 W m -1 K -1 is challenging. Widely used pump/probe metrologies, such as time–domain thermoreflectance (TDTR) and frequency–domain thermoreflectance, lack the spatiotemporal resolution necessary to accurately quantify thermal properties of sub-micrometer thin films with high Λ. In this work, we use a combination of magneto-optic thermometry and TiN interfacial layers to significantly enhance the spatiotemporal resolution of pump/probe thermal transport measurements. We use our approach to measure Λ of 100, 400, and 1000 nm AlN thin films. We coat AlN thin films with a ferromagnetic thin-film transducer with the geometry of (1 nm-Pt/0.4 nm-Co) x3 /(2 nm-TiN). This PtCo/TiN transducer has a fast thermal response time of <50 ps, which allows us to differentiate between the thermal response of the transducer, AlN thin film, and substrate. For the 100, 400, and 1000 nm thick AlN films, we determine Λ to be 200 ± 80, 165 ± 35, and 300 ± 70 W m -1 K -1 , respectively. We conclude with an uncertainty analysis that quantifies the errors associated with pump/probe measurements of thermal conductivity, as a function of transducer type, thin-film thermal conductivity, and thin-film thickness. Time resolved magneto-optic Kerr effect experiments can measure films that are three to five times thinner than is possible with standard pump/probe metrologies, such as TDTR. This advance in metrology will enable better characterization of nanoscale heat transfer in high thermal conductivity material systems like wide bandgap semiconductor heterostructures and devices.

36 MATERIALS SCIENCE↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

Probing C–I bond fission in the UV photochemistry of 2-iodothiophene with core-to-valence transient absorption spectroscopy

The UV photochemistry of small heteroaromatic molecules serves as a testbed for understanding fundamental photo-induced chemical transformations in moderately complex compounds, including isomerization, ring-opening, and molecular dissociation. Here, a combined experimental-theoretical study of 268 nm UV light-induced dynamics in 2-iodothiophene (C 4 H 3 IS) is performed. The dynamics are experimentally monitored with a femtosecond extreme ultraviolet (XUV) probe that measures iodine N-edge 4d core-to-valence transitions. Experiments are complemented by density functional theory calculations of both the pump-pulse induced valence excitations and the XUV probe-induced core-to-valence transitions. Possible intramolecular relaxation dynamics are investigated by ab initio molecular dynamics simulations. Furthermore, gradual absorption changes up to ~0.5 to 1 ps after excitation are observed for both the parent molecular species and emerging iodine fragments, with the latter appearing with a characteristic rise time of 160 ± 30 fs. Comparison of spectral intensities and energies with the calculations identifies an iodine dissociation pathway initiated by a predominant π → π* excitation. In contrast, initial excitation to a nearby n ⟂ → σ* state appears unlikely based on a significantly smaller oscillator strength and the absence of any corresponding XUV absorption signatures. Excitation to the π → π* state is followed by contraction of the C–I bond, enabling a nonadiabatic transition to a dissociative π→σ C-I * state. For the subsequent fragmentation, a relatively narrow bond-length region along the C–I stretch coordinate between 230 and 280 pm is identified, where the transition between the parent molecule and the thienyl radical + iodine atom products becomes prominent in the XUV spectrum due to rapid localization of two singly occupied molecular orbitals on the two fragments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanorod length-dependent photodriven H2 production in 1D CdS–Pt heterostructures

Colloidal quantum confined semiconductor-metal heterostructures are promising candidates for solar energy conversion because their light absorbing semiconductor and catalytic components can be independently tuned and optimized. Although the light-to-hydrogen efficiencies of such systems have shown interesting dependences on the morphologies of the semiconductor and metal domains, the mechanisms of such dependences are poorly understood. Here, we use Pt tipped 0D CdS quantum dots (with ∼4.6 nm diameter) and 1D CdS nanorods (of ∼13.8, 27.8, 66.6, and 88.9 nm average rod lengths) as a model system to study the distance-dependence of charge separation and charge recombination times and their impacts on photo-driven H2 production. The H2 generation quantum efficiency increases from 0.2% ± 0.0% in quantum dots to 28.9% ± 0.4% at a rod length of 28 nm and shows negligible changes at longer rod lengths. The half-life time of electron transfer from CdS to Pt increases monotonically with rod length, from 0.7 ± 0.1 in quantum dots to 170.2 ± 29.5 ps in the longest rods, corresponding to a slight decrease in electron transfer quantum efficiency from 92% to 81%. The amplitude-weighted average lifetime of charge recombination of the electron in Pt with the hole in CdS increases from 4.7 ± 0.4 µs in quantum dots to 149 ± 34 µs in 28 nm nanorods, and the lifetime does not increase further in longer rods, resembling the trend in the observed H2 generation quantum efficiency. Our result suggests that the competition of the charge recombination process with the hole removal by the sacrificial electron donor plays a dominant role in the observed nanorod length dependent overall light driven H2 generation quantum efficiency.

Chemistry↗