Sparse sampling and reconstruction for electron and scanning probe microscope imaging

Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

General Mode Scanning Probe Microscopy

A critical part of SPM measurements is the information transfer from the probe-sample junction to the measurement system. Current information transfer methods heavily compress the information-rich data stream by averaging the data over a time interval, or via heterodyne detection approaches such as lock-in amplifiers and phase-locked loops. As a consequence, highly valuable information at the sub-microsecond time scales or information from frequencies outside the measurement band is lost. We have developed a fundamentally new approach called General Mode (G-mode), where we can capture the complete information stream from the detectors in the microscope. The availability of the complete information allows the microscope operator to analyze the data via information-theory analysis or comprehensive physical models. Furthermore, the complete data stream enables advanced data-driven filtering algorithms, multi-resolution imaging, ultrafast spectroscropic imaging, spatial mapping of multidimensional variability in material properties, etc. Though we applied this approach to scanning probe microscopy, the general philosophy of G-mode can be applied to many other modes of microscopy. G-mode data is captured by completely custom software written in LabVIEW and Matlab. The software generates the waveforms to electrically, thermally, or mechanically excite the SPM probe. It handles real-time communications with the microscope software for operations such as moving the SPM probe position and also controls other instrumentation hardware. The software also controls multiple variants of high-speed data acquisition cards to excite the SPM probe with the excitation waveform and simultaneously measure multiple channels of information from the microscope detectors at sampling rates of 1-100 MHz. The software also saves the raw data to the computer and allows the microscope operator to visualize processed or filtered data during the experiment. The software performs all these features while offering a user-friendly interface.

Somnath, Suhas↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

Cooks, Robert Graham↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bile salt hydrolase probe and method of making and using the same

Probe embodiments for targeting, identifying, and isolating enzymes exhibiting BSH activity as well as devices and kits that use the probes are described herein. Methods of making and using the probes, devices, and kits are also described. In some embodiments, probes, devices, and kits for targeting, identifying, and isolating enzymes in a biological sample are disclosed. In some embodiments, compositions and methods of treatment using the probes, devices, and kits disclosed herein are described.

Wright, Aaron T.↗

Rotating concave eddy current probe

A rotating concave eddy current probe for detecting fatigue cracks hidden from view underneath the head of a raised head fastener, such as a buttonhead-type rivet, used to join together structural skins, such as aluminum aircraft skins. The probe has a recessed concave dimple in its bottom surface that closely conforms to the shape of the raised head. The concave dimple holds the probe in good alignment on top of the rivet while the probe is rotated around the rivet's centerline. One or more magnetic coils are rigidly embedded within the probe's cylindrical body, which is made of a non-conducting material. This design overcomes the inspection impediment associated with widely varying conductivity in fastened joints.

47 OTHER INSTRUMENTATION↗

Arrays of probes for positional sequencing by hybridization

This invention is directed to methods and reagents useful for sequencing nucleic acid targets utilizing sequencing by hybridization technology comprising probes, arrays of probes and methods whereby sequence information is obtained rapidly and efficiently in discrete packages. That information can be used for the detection, identification, purification and complete or partial sequencing of a particular target nucleic acid. When coupled with a ligation step, these methods can be performed under a single set of hybridization conditions. The invention also relates to the replication of probe arrays and methods for making and replicating arrays of probes which are useful for the large scale manufacture of diagnostic aids used to screen biological samples for specific target sequences. Arrays created using PCR technology may comprise probes with 5'- and/or 3'-overhangs.

59 BASIC BIOLOGICAL SCIENCES↗

Science of the Van Allen Probes Science Operations Centers

The Van Allen Probes mission operations materialized through a distributed model in which operational responsibility was divided between the Mission Operations Center (MOC) and separate instrument specific SOCs. The sole MOC handled all aspects of telemetering and receiving tasks as well as certain scientifically relevant ancillary tasks. Each instrument science team developed individual instrument specific SOCs proficient in unique capabilities in support of science data acquisition, data processing, instrument performance, and tools for the instrument team scientists. In parallel activities, project scientists took on the task of providing a significant modeling tool base usable by the instrument science teams and the larger scientific community. With a mission as complex as Van Allen Probes, scientific inquiry occurred due to constant and significant collaboration between the SOCs and in concert with the project science team. Planned cross-instrument coordinated observations resulted in critical discoveries during the seven-year mission. Instrument cross-calibration activities elucidated a more seamless set of data products. Specific topics include post-launch changes and enhancements to the SOCs, discussion of coordination activities between the SOCs, SOC specific analysis software, modeling software provided by the Van Allen Probes project, and a section on lessons learned. One of the most significant lessons learned was the importance of the original decision to implement individual team SOCs providing timely and well-documented instrument data for the NASA Van Allen Probes Mission scientists and the larger magnetospheric and radiation belt scientific community.

47 OTHER INSTRUMENTATION↗

A Comparison of the Use of Radar Images and Neutron Probe Data to Determine the Horizontal Correlation Length of Water Content

Surface-based ground-penetrating radar data were collected at the Hanford Site in Washington, U.S.A. to assess the use of radar reflection images as a means of quantifying the spatial variability of subsurface water content. Available at the selected test site were two sets of water content data derived from neutron probe measurements that had been made to a depth of ~18 m in 32 wells. The comparison of probe-derived water content data, synthetic radar data, and the acquired radar data indicated a good correspondence between the changes in probe-derived water content and the location of reflections in the radar data. Geostatistical analysis was conducted on the two sets of probe-derived water content values and the amplitudes of the reflections in the radar reflection image to determine the horizontal correlation length of water content. The experimental semivariograms for the water content data were fit with a single exponential model with a correlation length of 10 m. The semivariogram for the radar data was fit with a nested structure containing a dominant long-range structure with a correlation length of 14 m, and a smaller-scale structure with a correlation length of 0.3 m. Quantifying the scale triplet – the spacing, extent, and support – for the two forms of measurement provided a framework for comparing and assessing the derived correlation structures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Van Allen Probes observations of electromagnetic ion cyclotron waves triggered by enhanced solar wind dynamic pressure

Magnetospheric compression due to impact of enhanced solar wind dynamic pressure P dyn has long been considered as one of the generation mechanisms of electromagnetic ion cyclotron (EMIC) waves. Here, with the Van Allen Probe-A observations, we identify three EMIC wave events that are triggered by P dyn enhancements under prolonged northward interplanetary magnetic field (IMF) quiet time preconditions. They are in contrast to one another in a few aspects. Event 1 occurs in the middle of continuously increasing P dyn while Van Allen Probe-A is located outside the plasmapause at postmidnight and near the equator (magnetic latitude (MLAT) ~ -3°). Event 2 occurs by a sharp P dyn pulse impact while Van Allen Probe-A is located inside the plasmapause in the dawn sector and rather away from the equator (MLAT ~ 12°). Event 3 is characterized by amplification of a preexisting EMIC wave by a sharp P dyn pulse impact while Van Allen Probe-A is located outside the plasmapause at noon and rather away from the equator (MLAT ~ -15°). These three events represent various situations where EMIC waves can be triggered by P dyn increases. Several common features are also found among the three events. (i) The strongest wave is found just above the He + gyrofrequency. (ii) The waves are nearly linearly polarized with a rather oblique propagation direction (~28° to ~39° on average). (iii) The proton fluxes increase in immediate response to the P dyn impact, most significantly in tens of keV energy, corresponding to the proton resonant energy. (iv) The temperature anisotropy with T ⊥ > T || is seen in the resonant energy for all the events, although its increase by the P dyn impact is not necessarily always significant. Finally, the last two points (iii) and (iv) may imply that in addition to the temperature anisotropy, the increase of the resonant protons must have played a critical role in triggering the EMIC waves by the enhanced P dyn impact.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

dried blood spots↗

Liquid microjunction surface sampling probe fluid dynamics: Characterization and application of an analyte plug formation operational mode

The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) (J. Am. Soc. Mass Spectrom, 2011) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injection plug peak widths were consistent for plug hold times as long as the 8 minute maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Lastly, using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, synthesis, and biological evaluation of 4-(5-dimethylamino-naphthalene-1-sulfon-amido)-3-(4-iodophenyl)butanoic acid as a novel molecular probe for apoptosis imaging

Research highlights: {yields} Annexin V is the gold standard probe for imaging apoptosis. {yields} Unfavorable profiles of Annexin V make it difficult to apply in the clinic. {yields} A novel small-molecular probe DNSBA was designed as an alternative to Annexin V. {yields} DNSBA specifically and selectively detect apoptotic cancer cells at all stages. {yields} DNSBA is a potential SPECT and PET agent when labeled with radioiodine. -- Abstract: Apoptosis (programmed cell death) plays a crucial role in the pathogenesis of many disorders, thus the detection of apoptotic cells can provide the physician with important information to further therapeutic strategies and would substantially advance patient care. A small molecule, 4-(5-dimethylamino-naphthalene-1-sulfonamido)-3-(4-iodo-phenyl)butanoic acid (DNSBA), was designed as a novel probe for imaging apoptosis and synthesized with good yield. The biological characterization demonstrated that DNSBA can be used to specifically and selectively detect apoptotic cancer cells at all stages. DNSBA is also designed as a potential SPECT and PET probe when labeled with radioiodine (I-123, -124, and -131).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

60 APPLIED LIFE SCIENCES↗

Thermalization of the Kerr index of refraction in acetone and methanol using femtosecond pump-probe scattering spectroscopy

Femtosecond time-resolved pump-probe scattering is used to temporally investigate the index thermalization Δn(t) of the molecular motions associated with the Kerr nonlinear index n 2 . This is done using an intense 300 fs 1034 nm pump pulse and temporally probed by a 517 nm and supercontinuum pulse in acetone and methanol. The optically pumped molecular states change the index of refraction and through the processes of Raman and Rayleigh scattering are shown to engage in a 4-step energy relaxation process. Here, the pump first initiates the Kerr effect as well as populate resonant vibrational molecular motions, which act as a “mother” energy state. The electronic component of the Kerr effect is shown to couple with these vibrational modes through the process of Born-Oppenheimer coupling, which can be measured through the Raman scattering of the probe. The “mother” coupled state then decays into “daughter” anharmonic non-resonant states, which then further decay into “granddaughter” and thermal bath states. The population of these states alter the index of refraction in time, Δn(t), and can be measured through the changing in the probe beam’s Rayleigh scattering. This thermalization process takes ~5.5 ps in acetone and ~3.7 ps in methanol. The scattering signals from each Δn(t) thermalization stage in the localized region, (“mother”, to “daughter”, to “granddaughter”, to the bath states, to the ground state), are fitted to theoretical decay equations that show the rise and fall times of the energy decay routes.

47 OTHER INSTRUMENTATION↗

Suppression of probe background signals via B1 field inhomogeneity

A new approach combining a long pulse with the DEPTH sequence (Cory and Ritchey, Journal of Magnetic Resonance, 1988) greatly improves the efficiency for suppressing probe background signals arising from spinning modules. By applying a long initial excitation pulse in the DEPTH sequence, instead of a {pi}/2 pulse, the inhomogeneous B{sub 1} fields outside the coil can dephase the background coherence in the nutation frame. The initial long pulse and the following two consecutive EXORCYCLE {pi} pulses function complementarily and prove most effective in removing background signals from both strong and weak B{sub 1} fields. Experimentally, the length of the long pulse can be optimized around odd multiples of the {pi}/2 pulse, depending on the individual probe design, to preserve signals inside the coil while minimizing those from probe hardware. This method extends the applicability of the DEPTH sequence to probes with small differences in B{sub 1} field strength between the inside and outside of the coil, and can readily combine with well-developed double resonance experiments for quantitative measurement. In general, spin systems with weak internal interactions are required to attain efficient and uniform excitation for powder samples, and the principles to determine the applicability are discussed qualitatively in terms of the relative strength of spin interactions, r.f. power and spinning rate.

47 OTHER INSTRUMENTATION↗

Impacts of Focused Ion Beam Processing on the Fabrication of Nanoscale Functionalized Probes

Herein, we examine the impact of Ga + ion kinetic energy and the target material type on the extent of ion implantation and structural damage in atomic force microscopy probes made of Al 2 O 3 and ZnO manufactured by focused ion beam (FIB) using scanning transmission electron microscopy and energy-dispersive X-ray mapping. Penetration of Ga into the Al 2 O 3 lattice induced structural distortions and amorphization. For ZnO probes, Ga is uniformly dispersed across the surface, resulting in the formation of distinct clusters. Atom probe tomography further validates the Ga distributions in Al 2 O 3 and ZnO nanoprobes. Complementary Monte Carlo simulations with the transport of ions in the matter program indicated that the introduction of Ga + prompts the generation of cation and anion vacancies, an occurrence more pronounced in Al 2 O 3 compared to ZnO. In conclusion, this study not only enriches the knowledge of ion-matter interactions, but also serves as a practical guide for the fabrication of nanoscale functionalized AFM probes.

Al2O3↗