Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORMANCE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Polyamide desalination membrane characterization and surface modification to enhance fouling resistance.

The market for polyamide desalination membranes is expected to continue to grow during the coming decades. Purification of alternative water sources will also be necessary to meet growing water demands. Purification of produced water, a byproduct of oil and gas production, is of interest due to its dual potential to provide water for beneficial use as well as to reduce wastewater disposal costs. However, current polyamide membranes are prone to fouling, which decreases water flux and shortens membrane lifetime. This research explored surface modification using poly(ethylene glycol) diglycidyl ether (PEGDE) to improve the fouling resistance of commercial polyamide membranes. Characterization of commercial polyamide membrane performance was a necessary first step before undertaking surface modification studies. Membrane performance was found to be sensitive to crossflow testing conditions. Concentration polarization and feed pH strongly influenced NaCl rejection, and the use of continuous feed filtration led to higher water flux and lower NaCl rejection than was observed for similar tests performed using unfiltered feed. Two commercial polyamide membranes, including one reverse osmosis and one nanofiltration membrane, were modified by grafting PEGDE to their surfaces. Two different PEG molecular weights (200 and 1000) and treatment concentrations (1% (w/w) and 15% (w/w)) were studied. Water flux decreased and NaCl rejection increased with PEGDE graft density ({micro}g/cm{sup 2}), although the largest changes were observed for low PEGDE graft densities. Surface properties including hydrophilicity, roughness and charge were minimally affected by surface modification. The fouling resistance of modified and unmodified membranes was compared in crossflow filtration studies using model foulant solutions consisting of either a charged surfactant or an oil in water emulsion containing n-decane and a charged surfactant. Several PEGDE-modified membranes demonstrated improved fouling resistance compared to unmodified membranes of similar initial water flux, possibly due to steric hindrance imparted by the PEG chains. Fouling resistance was higher for membranes modified with higher molecular weight PEG. Fouling was more extensive for feeds containing the cationic surfactant, potentially due to electrostatic attraction with the negatively charged membranes. However, fouling was also observed in the presence of the anionic surfactant, indicating hydrodynamic forces are also responsible for fouling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A mechanical property and stress corrosion evaluation of Custom 455 stainless steel alloy

The mechanical and stress corrosion properties are presented of vacuum melted Custom 455 stainless steel alloy bar (1.0-inch diameter) and sheet (0.083-inch thick) material aged at 950 F, 1000 F, and 1050 F. Low temperature mechanical properties were determined at temperatures of 80 F, 0 F, -100 F, and -200 F. For all three aging treatments, the ultimate tensile and 0.2 percent offset yield strengths increased with decreasing test temperatures while the elongation held fairly constant down to -100 F and decreased at -200 F. Reduction in Area decreased moderately with decreasing temperature for the longitudinal round (0.250-inch diameter) specimens. Notched tensile strength and charpy V-notched impact strength decreased with decreasing test temperature. For all three aging treatments, no failures were observed in the unstressed specimens or the specimens stressed to 50, 75, and 100 percent of their yield strengths for 180 days of alternate immersion testing in a 3.5 percent NaCl solution. As indicated by the results of tensile tests performed after alternate immersion testing, the mechanical properties of Custom 455 alloy were not affected by stress or exposure under the conditions of the evaluation.

Montano, J. W.↗

Air-liquid solar collector for solar heating, combined heating and cooling, and hot water subsystems

A collection of quarterly reports consisting of the installation and layout design of the air collector system for commercial applications, completion of the preliminary design review, detailed design efforts, and preparation of the verification test plan are given. Performance specifications and performance testing of a prototype model of a two manifold, 144 tube air collector array is presented.

Source record↗

Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

Source record↗

AMPA experimental communications systems

The program was conducted to demonstrate the satellite communication advantages of Adaptive Phased Array Technology. A laboratory based experiment was designed and implemented to demonstrate a low earth orbit satellite communications system. Using a 32 element, L-band phased array augmented with 4 sets of weights (2 for reception and 2 for transmission) a high speed digital processing system and operating against multiple user terminals and interferers, the AMPA system demonstrated: communications with austere user terminals, frequency reuse, communications in the face of interference, and geolocation. The program and experiment objectives are described, the system hardware and software/firmware are defined, and the test performed and the resultant test data are presented.

Beckerman, D.↗

Task Board Tests Manipulator Performance

Task board constructed to facilitate time-and-motion studies for remote manipulators. Apparatus equipped with holes, objects of various shapes to be grasped and sensors with switches to indicate contact. Useful in industrial robots programmed to assemble parts.

Hill, J. W.↗

Preparation, characterization, physical testing and performance of flurocarbon membranes and separators

The direct fluorination method of converting carefully selected hydrocarbon substrates to fluorinated membranes was successfully applied to produce promising, novel membranes for electrochemical devices. A family of polymer blends was identified which permits wide latitude in the concentration of both crosslinks and carboxyl groups in hydrocarbon membranes. The membranes of paragraph two were successfully fluorinated.

Lagow, R. J.↗

Preparation, characterization, physical testing and performance of fluorocarbon membranes and separators

The direct fluorination method of converting carefully selected hydrocarbon substrates to fluorinated membranes was successfully applied to produce promising, novel membranes for electrochemical devices. A family of polymer blends was identified which permits wide latitude in the concentration of both crosslinks and carboxyl groups in hydrocarbon membranes. These membranes were successfully fluorinated and are potentially competitive with commercial membranes in performance, and potentially much cheaper in price.

Lagow, R. J.↗

Simulator Tests Controller Performance

Compact servosystem applies simulated dynamic loads, enabling realistic appraisal of motor and its control system without inconvenience of attaching real load. System simulates moments of inertia, rotational vibrations, changing load torques, and other characteristics of large or complex loads, without loads themselves and without awkwardness (and inaccuracy) of gravity-compensating devices used with such loads.

Lembeck, M. F.↗

Duty cycle testing and performance evaluation of the SM-229 teleoperator

The first known experimental studies and analyses of teleoperator performance for specific duty cycles are discussed. The results are presented in two distinct areas as position usage patterns, and as three-dimensional power grids. The position usage patterns are a valuable means to assess the available motion range. The power grids are a unique concept for evaluating joint performance. Final conclusions contain recommendations to upgrade the teleoperator for optimum performance.

Stoughton, Robert S.↗

Kapton wire arc track testing: Per test procedure KWATT BB01

The results are presented of Kapton wire arc tracking tests performed at NASA-Johnson in 1990 using test procedure KWATT BB01. The tests were performed to gather data for use in assessing the safety of the Space Shuttle Orbiter wiring which is predominantly Kapton insulated.

Source record↗

System Testing and Performance Characterization of the LITE Laser Transmitter Module at NASA

The Laser Transmitter Module (LTM) is a three-color Q-switched flashlamp pumped Nd:YAG laser. The original design concept was to package commercially available optics and flashlamp electronics for spaceflight with a power consumption goal of 2200 W and a weight goal of 600 lbs. The optical output was to exceed 200 mJ of IR, 400 mJ of green, and 150 mJ of UV per pulse at 10 Hz. The new space qualified laser exceeds the optical output requirements by 188 percent, 50 percent, and 13 percent in the UR, green, and UV respectively. This output needs only 1500 W at a weight of only 500 lbs. The LTM was delivered to the NASA Langley Research Center in December 1991. Optical characterization is now being completed.

Cimolino, Marc C.↗