Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE IDENTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Indirect Observation of an In-Medium {eta}{sup '} Mass Reduction in {radical}(s{sub NN})=200 GeV Au+Au Collisions

PHENIX Collaboration and STAR Collaboration data on the intercept parameter of the two-pion Bose-Einstein correlation functions in {radical}(s{sub NN})=200 GeV Au+Au collisions are analyzed in terms of different models of hadronic multiplicities. To describe this combined PHENIX and STAR data set, an in-medium {eta}{sup '} mass reduction of at least 200 MeV is needed, at the 99.9% confidence level in the considered model class. Such a significant {eta}{sup '} mass modification may indicate the restoration of the U{sub A}(1) symmetry in a hot and dense hadronic matter and the return of the 9th ''prodigal'' Goldstone boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposal for GPD studies at COMPASS

The study of nucleon structure through Generalised Parton Distributions (GPD) is one major part of the future COMPASS-II physics program and can be performed using exclusive reactions like Deeply Virtual Compton Scattering (DVCS) and Meson Production. The high energy of the muon beam allows to measure the x{sub B}-dependence of the t-slope of the DVCS cross section. The use of positive and negative polarised muon beams allows to determine the Beam Charge and Spin Difference of the DVCS cross sections to access the real part of the Compton form factor related to the dominant GPD H. The sensitivity of both measurements is examined and confronted to existing models or global fits of the data. Preliminary beam test data were analyzed and demonstrated the feasibility of the identification of the DVCS reaction using the COMPASS experimental set-up.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics of fast timing MCP-PMTs in magnetic fields

Here, the motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance. MCP-PMTs based on two different designs were tested. The magnetic field tolerance of MCP-PMT based on a design providing independently biased voltages showed a significant improvement (up to 0.7 T) compared to the one utilizing an internal resistor chain design (up to 0.1 T), indicating the importance of individually adjustable voltages. The effects of the rotation angle of the MCP-PMT relative to the magnetic field direction and of the bias voltage between the photocathode and the top MCP were extensively investigated using the MCP-PMT based on the independently biased voltage design. It was found that the signal amplitude of the MCP-PMT exhibits an enhanced performance at a tilt angle of ±8°, due to the 8°bias angle of the MCP pores. Fianlly, the maximum signal amplitude was observed at different bias voltages depending on the magnetic field strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological Source Term Estimation and Isotopic Identification with Parallel Log Domain Particle Filters

This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.

42 ENGINEERING↗

In-situ Determination of the ATLAS Muon Performance

The ATLAS detector allows for the precise and efficient reconstruction of muons. Muon tracks are reconstructed with 97% efficiency with a momentum resolution of approximately 2-3% over most of the kinematic range and better than 10% for transverse momenta up to 1 TeV and |eta|<2.7. We present methods to measure the performance of the muon identification during the operation of the ATLAS detector using muons from Z and J/psi decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Reconstruction and Identification with the ATLAS Detector

Several Standard Model processes contain electrons in the final state. Also, many signatures expected from physics beyond the Standard Model include one or more electrons. This paper describes the electron reconstruction along with some of the identification criteria used in the ATLAS detector. The expected performance at the start-up of the experiment are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron Spectroscopy at CLEO

New measurements of the masses and decay branching fractions of charmonium and bottomonium states using the data collected by the CLEO detector are presented. These include CLEO identification of the singlet states {eta}'{sub c}(2S), h{sub c}(1P), and {eta}{sub b}(1S). Comparison with other experimental measurements and theoretical models is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for and identification of effects of extra spatial dimensions in dilepton and diphoton production at the Large Hadron Collider

Prospects of discovering and identifying effects of extra spatial dimensions in dilepton and diphoton production at the Large Hadron Collider (LHC) are studied. Such effects may be revealed by the characteristic behavior of the invariant-mass distributions of dileptons and diphotons, and their identification can be performed on the basis of an analysis of their angular distributions. The discovery and identification reaches are estimated for the scale parameter M{sub S} of the Kaluza-Klein gravitational towers, which can be determined in experiments devoted to measuring the dilepton and diphoton channels at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy flavor identification using multivariate analysis at H1

We discuss b quark identification in deep inelastic scattering of electron on proton at H1 by applying multivariate analysis method. Separation between heavy and light flavors can be further used to extract proton quark content.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SUSY mass determination using kinematic fits

After the discovery of supersymmetry, the next step will be the identification of the underlying theory, its fundamental parameters, and the masses of SUSY particles. We followed here the approach to reconstruct whole SUSY events with rather similar decay topologies, under the assumption of common intermediate SUSY masses. Each event alone has too many unknowns, namely the unmeasured LSP momenta, as well as the SUSY masses. But an ensemble of such a class of events can be over-constrained, if the decay chains are long enough, i.e. if enough mass constraints are available. We present a new method based on a genetic algorithm to reconstruct such event topologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Reconstruction and Identification in CMS

We present the design strategies and status of the CMS muon reconstruction and identification identification software. Muon reconstruction and identification is accomplished through a variety of complementary algorithms. The CMS muon reconstruction software is based on a Kalman filter technique and reconstructs muons in the standalone muon system, using information from all three types of muon detectors, and links the resulting muon tracks with tracks reconstructed in the silicon tracker. In addition, a muon identification algorithm has been developed which tries to identify muons with high efficiency while maintaining a low probability of misidentification. The muon identification algorithm is complementary by design to the muon reconstruction algorithm that starts track reconstruction in the muon detectors. The identification algorithm accepts reconstructed tracks from the inner tracker and attempts to quantify the muon compatibility for each track using associated calorimeter and muon detector hit information. The performance status is based on detailed detector simulations as well as initial studies using cosmic muon data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CMS RPC SYSTEM OVERVIEW

The Muon System of the CMS experiment at CERN employees three different detector technologies--Drift Tube Chambers (DT) in the barrel part, Cathode Strip Chambers (CSC) in the endcaps and Resistive Plate Chambers (RPC) both in the barrel and the endcaps. TDs and CSCs serve as precise muon trajectory measurement devices. The RPCs are responsible for the bunch crossing identification and for a fast muon transverse momentum measurement. The total number of RPCs is 480 in the barrel and 756 in the endcaps, covering an area of about 3500 square meters. A brief overview of the system will be presented as well as some recent results about the system stability and performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft Classification of Diffractive Interactions at the LHC

Multivariate machine learning techniques provide an alternative to the rapidity gap method for event-by-event identification and classification of diffraction in hadron-hadron collisions. Traditionally, such methods assign each event exclusively to a single class producing classification errors in overlap regions of data space. As an alternative to this so called hard classification approach, we propose estimating posterior probabilities of each diffractive class and using these estimates to weigh event contributions to physical observables. It is shown with a Monte Carlo study that such a soft classification scheme is able to reproduce observables such as multiplicity distributions and relative event rates with a much higher accuracy than hard classification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The reliability of macroscopic identification of lunar coarse fines particles and the petrogenesis of 2-4 mm particles in Apennine Front sample 15243

Particles from the 15243 Apennine Front sample (Station 6) were studied using macroscopic, neutron activation, and petrographic methods. It was found that macroscopic identifications allow for good identification of the particles. It was shown that the Station 6 regolith must consist of a fine-grained, comparatively KREEP-poor material and a coarser component consisting of Apollo 15 KREEP basalts and KREEP-like impact melt fragments.

Ryder, Graham↗

B{sup +} and D{sub s}{sup +} Decay Constants from Belle and Babar

The Belle and Babar experiments have measured the branching fractions for B{sup +}{yields}{tau}{sup +}{nu} and D{sub s}{sup +}{mu}{sup +}{nu} decays. From these measurements one can extract the B{sup +} and D{sub s}{sup +} decay constants, which can be compared to lattice QCD calculations. For the D{sub s}{sup +} decay constant, there is currently a 2.1{sigma} difference between the calculated value and the measured value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The SuperB Experiment

In these proceedings I briefly introduce the project prior to discussing the physics programme of the SuperB high luminosity e{sup +}e{sup -} collider. By measuring the golden matrix SuperB will be able to elucidate and constrain the nature of physics beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Bottom-Up Approach to SUSY Analyses

A new way to perform event generation and analysis in searches for new physics at the LHC is proposed. In particular, a coherent approach to covering the complete SUSY phase space by identifying a small number of eigenmodes each with only a few parameters is presented. By focusing on a systematic understanding of the experimental efficiency space the Bottom-Up Approach allows to maximize the sensitivity in SUSY parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗