Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

w19_nubhlight (Final Report)

The in-spiral and merger of two neutron stars produces several signals observable on Earth. The in-spiral of two compact objects produces gravitational waves - ripples in spacetime - detectable by the LIGO and VIRGO detectors. The two stars will tidally disrupt each other, throwing off material, some of which escapes and some of which forms a disk of hot nuclear matter accreting onto the central remnant. This accretion drives a pair of powerful ultra-relativistic jets of material along the polar axis. These jets are ultimately responsible for producing short gamma-ray bursts, some of the most brilliant and energetic events in the cosmos.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Energy Dependent Fission Product Yields (2nd year Milestone and Deliverables)

Introduction to the project: One of the Laboratory missions is to provide consistent, high-precision fission product; yield data critical for testing fission models and maintaining the safety and security of the nation’s nuclear weapons stockpile. However, high-quality, energy-differential fission product yield data is missing for certain actinides and neutron energies important to constrain the new U.S. Nuclear Data Program evaluation effort; It has been shown that the reactor antineutrino anomaly may be at least partially caused by roughly 20 fission products. The fission product yield data is missing or incomplete for many of these isotopes, thus it is necessary to accurately determine these values to better constrain the anomaly; Aitor Bracho is measuring very short-lived (seconds to minutes) fission product yields of 235 U and 239 Pu using monoenergetic neutron beams at E n = 60 and 560 keV; Aitor Bracho is using a direct approach utilizing a state-of-the-art rabbit transfer system, superior HPGe detector, and digital acquisition systems for fission decay measurements. The goals of this project: lop experimental capabilities and data analysis techniques to carry out the gamma-ray spectra analysis necessary for fission product yield calculation; Provide high-precision and energy-dependent fission product data supporting fission theory, neutrino physics, and applied physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing for coherence and nonstandard neutrino interactions in COHERENT data

We analyze data from the CsI, liquid Ar and Ge detectors of the COHERENT experiment and confirm within 1.5 σ that the measured elastic neutrino-nucleus scattering cross section is proportional to the square of the number of neutrons in the nucleus, as expected for coherent scattering in the standard model. We also show how various degeneracies involving nonstandard neutrino interaction parameters are broken in a combined analysis of the three datasets. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

List Mode Data from the Modular Vehicle Detector System

In 2022 measurements were made with the Modular Vehicle Detectors (MVD) at the National Criticality Experiments Research Center (NCERC), located in the Device Assembly Facility (DAF) on the Nevada National Security Site (NNSS), Nevada. These detectors were supplied by the Naval Information Warfare Center (NIWC) Pacific. The MVDs were connected to an Advanced List Mode Module (ALMM) which records when an MVD detected a neutron. This is a summary of the measurement configurations as well as a list of the list-mode data files from each configuration. In addition to the measurements taken at NCERC additional measurements with the MVDs were taken at Los Alamos National Laboratory (LANL).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

R-Matrix Analysis of the Neutron-Induced Cross Sections on 143 Nd and 147,149 Sm Measured at LANSCE [Slides]

This presentation covers how an established used of R-Matrix codes is being implemented at LANSCE. This presentation displays how there are unique features accessible with detectors at LANSCE that can be used to perform more complete R-Matrix analysis. Additionally discussed is how spin separation is a powerful technique that can be applied in DANCE measurements. Unique method to measure transmission with DICER are discussed. Finally, transmission and capture data are being analyzed in this work. The study can be extended to other channels. The ongoing analysis of the 143 Nd data is presented in this work. The same method is being applied to analyze the 147,149 Sm data. The 143 Nd and 147,149 Sm work started in FY-23 funded by NCSP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactor rate modulation oscillation analysis with two detectors in Double Chooz

A θ 13 oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of θ 13 and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the ${\overline{\nu}}_e$ interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and 9 Li decays. The background-model-independent determination of the mixing angle yields sin 2 (2 θ 13 ) = 0.094 ± 0.017, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on θ 13 to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86%, reducing the 1.43% uncertainty associated to the expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗