Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Fission foil measurements of neutron and proton fluences in the A0015 experiment

Results are given from sets of fission foil detectors (FFD's) (Ta-181, Bi-209, Th-232, U-238) which were included in the A0015 experiment to measure combined proton/neutron fluences. Use has been made of recent FFD high energy proton calibrations for improved accuracy of response. Comparisons of track density measurements have been made with the predictions of environmental modeling based on simple 1-D (slab) geometry. At 1 g/cm(exp 2) (trailing edge) the calculations were approximately 25 percent lower than measurements; at 13 g/cm(exp 2) (Earthside) calculations were more than a factor of 2 lower. A future 3-D modeling of the experiment is needed for a more meaningful comparison. Approximate mission proton doses and neutron dose equivalents were found. At Earthside (13 g/cm(exp 2) the dose was 171 rad and dose equivalent was 82 rem. At the trailing edge (1 g/cm(exp 2) dose was 315 rad and dose equivalent was 33 rem. The proton doses are less than expected from TLD doses by 16 percent and 37 percent, respectively. These differences can be explained by uncertainties in the proton and neutron spectra and in the method used to separate proton and neutron contributions to the measurements.

Frank, A. L.↗

A First Search for Argon-Bound Neutron-Antineutron Oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n ₋ n̄) oscillation. The n ₋ n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n ₋ n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n ₋ n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first search for argon-bound neutron-antineutron oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n – n̄) oscillation. The n – n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n – n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n – n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy spectrum and flux of fast neutrons in the atmosphere

The neutron energy spectrum and flux in the atmosphere at the Pfotzer maximum (about 100 g per cm squared) were measured at geomagnetic latitude 42 deg N, using a system capable of detecting a small flux of fast (5 to 20 MeV) neutrons in a much larger background flux of gamma rays and charged particles. The detector consisted of a cylindrical cell of organic liquid scintillator coupled to a high-resolution two-parameter multiparticle pulse shape discriminator with a two-parameter logarithmic pulse-height analyzer. The spectral parameter for the differential neutron energy spectrum was found to decrease from 4.4 plus or minus 0.8 between 3.5 and 6.0 MeV to 1.5 plus or minus 1.0 in the interval 11 to 20 MeV; a value of 0.36 plus or minus 0.10 neutrons per cm squared was calculated for neutron flux between 3.5 and 10 MeV. The importance of these results for evaluating the role of albedo neutron leakage as a source of the energetic proton flux in the radiation belts is also considered.

Saint Onge, R. N.↗

Nuclear recoil detection with color centers in bulk lithium fluoride

We present initial results on the detection of nuclear recoils in lithium fluoride (LiF) through the fluorescence of color centers created by particle interactions in the crystal lattice. Using light-sheet fluorescence microscopy, we image nuclear recoil tracks from both fast and thermal neutron interactions deep within a cubic-centimeter-scale sample. Automated three-dimensional feature extraction based on machine-learning tools enables the identification and classification of individual events. We observe that the fluorescence response of LiF to gamma irradiation is strongly suppressed, by a factor of 30–50 compared to neutron exposure, demonstrating intrinsic insensitivity to electromagnetic backgrounds. The observed and simulated event characteristics are consistent, including their number, size, and topology. These results establish the feasibility of LiF as a scalable detection medium for rare nuclear-recoil events and constitute a first step toward 10–1000 g scale detectors with single-event sensitivity for applications in reactor-neutrino detection, neutron spectroscopy, and dark matter searches.

Aroujo, G R [University of Zurich]↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved limits on Fierz interference using asymmetry measurements from the Ultracold Neutron Asymmetry (UCNA) experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the β-decay asymmetry parameter, A 0 , for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their β-decay electrons are detected with ≈4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to b n , the Fierz interference term in the neutron β-decay rate. In this work, we determine bn from the energy dependence of A 0 using the data taken during the UCNA 2011–2013 run. In addition, we present the same type of analysis using the earlier 2010 A dataset. Furthermore, motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new b n measurement using the weighted average of our asymmetry dataset fits, to obtain b n = 0.066 ± 0.041 stat ± 0.024 syst which corresponds to a limit of -0.012 < b n < 0.144 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SNAPRed: Reduction of multidimensional neutron time-of-flight diffraction data

SNAP is a neutron time-of-flight diffractometer at the Spallation Neutron Source operated by Oak Ridge National Laboratory. It generates large arrays of neutron detection events that encode the crystalline atomic structure of materials under study. SNAPRed is an application that makes these datasets accessible to end users by orchestrating the process of data reduction while automatically managing the variable neutron instrumentation configuration. It supports arbitrary grouping and masking of individual detector pixels and includes custom-developed data compression approaches to accommodate the large volumes of data generated by the SNAP instrument.

Diffraction↗

Measurement of 0.511-MeV gamma rays with a balloon-borne Ge/Li/ spectrometer

A collimated high-resolution gamma ray spectrometer was flown on a balloon over Palestine, Texas, on June 10, 1974, to obtain measurements of the terrestrial and extraterrestrial 0.511-MeV gamma rays. The spectrometer consists of four 40-cu-cm Ge(Li) crystals operating in the energy range 0.06-10 MeV; this cluster of detectors is surrounded by a CsI(Na) anticoincidence shield. This system is used primarily to allow measurements of the two escape peaks associated with high-energy gamma ray lines. It also allows a measurement of the background component of the 0.511-MeV flux produced by beta(+) decays in materials inside the CsI(Na) shield. It is shown that the measurements of the atmospheric fluxes are consistent with earlier results after allowance is made for an additional component of the background due to beta(+) decays produced by neutron- and proton-initiated interactions with materials in and near the detector. Results of the extraterrestrial flux require an extensive detailed analysis of the time-varying background because of activation buildup and balloon spatial drifts.

Ling, J. C.↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Cosmogenic activation of silicon

In the production of 3 H, 7 Be, and 22 Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons at sea level is (112 ± 24) atoms/( kg day ) for 3 H, (8.1 ± 1.9) atoms/( kg day ) for 7 Be, and (43.0 ± 7.2) atoms/( kg day ) for 22 Na . Complementing these results with the current best estimates of activation cross sections for cosmic-ray particles other than neutrons, we obtain a total sea-level cosmic-ray production rate of (124 ± 25) atoms/(kg day) for 3 H, (9.4 ± 2.0) atoms/( kg day ) for 7 Be, and (49.6 ± 7.4) atoms/( kg day ) for 22 Na. These measurements will help constrain background estimates and determine the maximum time that silicon-based detectors can remain unshielded during detector fabrication before cosmogenic backgrounds impact the sensitivity of next-generation rare-event searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Space to Air High-Altitude Region Adjoint Neutron Transport

Neutrons from an atmospheric nuclear explosion can be detected by sensors in orbit. Current tools for characterizing the neutron energy spectrum assume a known source and use forward transport to recreate the detector response. In realistic scenarios the true source is unknown, making this an inefficient, iterative approach. In contrast, the adjoint approach directly solves for the source spectrum, enabling source reconstruction. The time–energy fluence at the satellite and adjoint transport equation allow a Monte Carlo method to characterize the neutron source’s energy spectrum directly in a new model: the Space to High-Altitude Region Adjoint (SAHARA) model. A new adjoint source event estimator was developed in SAHARA to find feasible solutions to the neutron transport problem given the constraints of the adjoint environment. This work explores SAHARA’s development and performance for mono-energetic and continuous neutron energy sources. In general, the identified spectra were shifted towards energies approximately 5% lower than the true source spectra, but SAHARA was able to capture the correct spectral shapes. Continuous energy sources, including real-world sources Fat Man and Little Boy, resulted in identifiable spectra that could have been produced by the same distribution as the true sources as demonstrated by two-dimensional (2D) Kolmogorov–Smirnov tests.

LaMere, Zachary W.↗

Beta-delayed gamma spectra compilation and analysis following the thermal-neutron induced fission of 235 U, 239,241 Pu

The integral gamma and electron spectra emitted by fission products, also known as delayed gamma and electron spectra, were measured at Oak Ridge National Laboratory in the 1970s for the thermal-neutron induced fission of 235 U and 239,241 Pu. Scintillator detectors were used to measure these spectra, data used later on to obtain decay heat values - that is, the spectra mean values per unit time as function of time - work that was published in the Nuclear Science and Technology journal; the spectral data, however, was only published in laboratory reports. Here, in this work, we analyze the gamma spectra data using modern methods and nuclear databases to reveal the signature of individual fission products as well as to gauge the performance of the ENDF/B-VIII.0 decay data sub-library, concluding about possible future enhancements in predictive capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗